SINGLE SEAL
PIPING PLAN 2 PIPING PLAN 11 PIPING PLAN 12 PIPING PLAN 13 PIPING PLAN 14
Pump Jacket Discharge Recirculation Discharge Recirculation with Strainer Suction Recirculation Suction and Discharge Recirculation (Vertical)
SP50
FLOW GUARDIAN
n U
se with single seal or double n Use with single seal or double seal n Use with single seal n Vents air and prevents dry run n Vents air and prevents dry run
PUMP seal to control seal chamber
DISCHARGE PUMP n Increases circulation PUMP n Cools seal n Prevents clogging n Use with single seal or double seal
AWC 14K temperature DISCHARGE DISCHARGE
RESTRICTION n Increases pressure in seal chamber n Increases pressure in seal chamber n Lowers pressure in seal chamber n Prevents clogging
(THROAT) BUSHING n Maintains or elevates box
(OPTIONAL) – Throat bushing optional
HEAT TRANSFER temperature to prevent product n Clean fluids only n Cools seal n Cools seal
FLUID OUT
solidification with polymers, – Solids can erode seal n Clean fluids only
n Reduces seal generated heat n Promotes flow
resins, tars – Solids can erode seal
n An orifice can be used to reduce
– Solids can clog seal when n Use caution with low vapor n Reduces seal generated heat
SEAL CHAMBER JACKET
n Lowers seal chamber temperature flow and pressure
AWC 14K bushing is used pressure liquids
in hot environments RESTRICTION AWC 14K
IN-LINE
n Use caution with low vapor
(THROAT) BUSHING RESTRICTION
PUMP (OPTIONAL) (THROAT) BUSHING STRAINER n An orifice can be used to reduce pressure liquids
SUCTION n Common heat transfer fluids: ORIFICE or
FITTING Y-STRAINER flow and pressure
– Water (OPTIONAL) (OPTIONAL) PUMP PUMP
PIPING PLAN 21 PIPING PLAN 23 PIPING PLAN 32 PIPING PLAN 33H PIPING PLAN 33S
Cooled Discharge Recirculation Cooled Seal Recirculation Clean Flush SpiralTrac™ Version D Type I SpiralTrac™ Version F Type S
SP50 SP50
SHELL SIDE VENT
HEAT EXCHANGER COOLANT n Use with a single seal HEAT EXCHANGER n Usewith a single seal and FLOW GUARDIAN n Use with a single seal n Use with a single seal FLOW GUARDIAN n Use with a single seal
OUT
COOLANT OUT TUBE SIDE VENT pump mechanism n Removes solids
n Cools hot, volatile fluids CLEAN FLUSH n Provides clean fluid to seal n Removes solids CLEAN FLUSH
15 Psi (1 bar)
n Minimizes heat exchanger size 15 Psi (1 bar)
ABOVE MAX SEAL n Seal runs in clean fluid
COOLANT
n Cools seal ABOVE MAX SEAL n Prevents clogging n Seal runs in clean fluid CHAMBER PRESSURE
IN and coolant water usage CHAMBER PRESSURE
INTEGRAL
PUMPING VANES
SpiralTrac is a trademark of EnviroSeal Engineering Products Limited. SpiralTrac is a trademark of EnviroSeal Engineering Products Limited.
DOUBLE SEAL
PIPING PLAN 52 PIPING PLAN 53A Circulation with PIPING PLAN 53B Closed Loop with PIPING PLAN 53C PIPING PLAN 53P Circulation with PIPING PLAN 54DM Circulation with
Circulation with External Buffer Fluid Tank Pressurized External Barrier Fluid Tank Heat Exchanger and Accumulator Heat Exchanger and Piston Accumulator Pressurized External Barrier Fluid Tank Pressurized External Barrier Fluid Source and
Flow Guardian™ DP50
VENT TO COLLECTION
n Use with a double seal OPTIONAL
EXTERNAL
PRESSURE
CHECK n Use with a double seal CHARGE n Use with double seals PRESSURE PRESSURE n Optional thermocouple CHECK n Maintains constant pressure and n Use with a double seal
OPTIONAL VALVE CONNECTION SWITCH VALVE ROTOMETER DP50
n Low pressure buffer fluid,
SOURCE RELIEF
liquid supply to the double seal FLOW GUARDIAN
FILL
FILL n Pressurize barrier fluid ACCUMULATOR n Optional thermocouple VALVE n No foaming n Pressurize barrier fluid
0,7 bar g (10 psig) minimum FLUID PRESSURE 1 – 2 bar g (15 – 30 psig) PISTON MAKE-UP FLUID PRESSURE n External water pressure is set at 1 – 2 bar g (15 – 30 psig)
LEVEL
CHECK PRESSURE LEVEL PRESSURE GAUGE n No foaming ACCUMULATOR VENT PRESSURE n Heat is removed by BARRIER FLUD PRESSURE GAUGE
SWITCH
VALVE GAUGE
n Buffer fluid should be clean,
SWITCH REGULATOR VENT over maximum seal CHECK PRESSURE PRESSURE
VALVE GAUGE REGULATOR 2 bar g (30 psig) over maximum over maximum seal
VENT
(OPTIONAL) VALVE SWITCH GAUGE HEAT an air-cooled or VENT
(OPTIONAL)
BUFFER FLUID TANK chamber pressure EXCHANGER n Heat is removed by HEAT seal chamber pressure chamber pressure
BUFFER FLUID TANK compatible and lubricating PRODUCT PRESSURE EXCHANGER water-cooled heat TO
QUENCH GAS
PRESSURE PRESSURE
SWITCH GAUGE
GAS n Venting of the seal chamber may
n Cleans atmospheric side of seal faces FLOWMETER
FILTERS 2μ
be required prior to start-up
FLOW
n Common quench fluids: PUMP SWITCH
– steam
– water
DISCHARGE
FLUSH PRESSURE
n Use Nitrogen, Carbon Dioxide or
Compressed Air 442 ™ AND 442C ™
SPLIT
(OPTIONAL) MONITORING ISOLATION CHECK
PUMP – nitrogen (OPTIONAL) VALVE VALVE n Zero emmissions and leakage
SUCTION
to atmosphere
MECHANICAL 1810
SEALS HEAVY-DUTY
MODULAR
170 SLURRY SINGLE SEAL
PUMP
SUCTION
DRAIN OUT
4400 GAS SEAL SINGLE SEAL
IN GLAND
CONTROL SYSTEM
chesterton.com