Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ISO A0 841mm x 1189mm

KEY PLAN

B01
Last Plotted: 2/27/2017 10:29:30 AM

6m
Copyright: MASDAR. All rights reserved. Except as permitted by

R7
m
1

R7

m
the Copyright, Designs and Patents Act 1998 no part of this
document may be reproduced, stored, transmitted or distributed
in any form or by any means, whether electronic, mechanical, by
A photocopy, recording or otherwise, without the prior written
permission of a director. Except where otherwise expressly

BS-09 (RAMP)
1500 10000 1180 agreed in writing MASDAR shall have no responsibility or liability

2m
for any loss (direct, consequential or otherwise) which may arise
E1
from reliance on or use of this document or the information
10 UP

contained in it.

GENERAL NOTES:

FL+5.00
UP
1. THIS DRAWING IS THE PROPERTY OF AECOM AND MUST NOT BE
RETAINED, COPIED OR USED WITHOUT THE LEAD CONSULTANT'S
FL+5.00 AUTHORITY.
2. ALL DIMENSION SHOWN ARE IN mm. UNLESS OTHERWISE NOTED.
3. DO NOT SCALE OFF THIS DRAWING. CHECK ALL DIMENSIONS ON
S TOR E-2
SITE AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES BEFORE
R 0009

PROCEEDING WITH THE WORK.


ESCAPE
C OR R IDOR
R 0044 4. THESE DRAWINGS SHOULD BE READ IN CONJUNCTION WITH
OTHER RELEVANT ARCHITECTURAL, ID, STRUCTURAL, MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
C ORE-E
C OR E-F
SPECIFICATIONS.
S ERV ICE RM-1 S ERV ICE RM-2
R 0042
R 0043
GL-1 GL-2

UP
5. FOR EXTERNAL LANDSCAPE DETAILS, REFER TO THE
GOODS
L IFT LOBBY
R 0011
GOODS
L IFT LOBBY
R 0019 LANDSCAPING PACKAGE
6. FOR ALL FOH INTERIOR WORKS, REFER TO ID PACAKGE
S TOR E-4
R 0013
FM PA NTRY
R 00 13A

FEMALE R 0038
FEMALE
L OCK ERS
R 0039
MALE
L OCK ERS
R 0040
MALE
7.THE LOCATIONS & SIZE OF THE MECHANICAL EQUIPMENTS &
R 0014
S HOWERS S HOWERS

EQUIPMENT PLINTH ARE SHOWN FOR INDICATIVE PURPOSES ONLY.

B AC K OF H OUSE
R 0012

B05 S ERV ICE YARD


R 0018
8.FOR ADDITIONAL INFORMATION ON MEP FIXTURES & EQUIPMENTS,
SEE RELATED MEP DRAWINGS.

B06
C OR R IDOR
R 0012

H FIX ED E QPMT.
FOU N D ATION
9.FOR EXACT LOCATIONS OF FLOOR DRAINS, TRENCH DRAINS, RAIN
S TOR E-1
R 0020
AHU
R 0021 WATER PIPE, SUMP PIT ETC REFER TO MEP DRAWINGS.
S MD B ROOM

R 0045
10.ACCESS HATCH OPENINGS FOR MEP SHAFTS: CONTRACTOR TO
ALLOW FOR ACCESS HATCH OPENINGS FOR SHAFTS AS PER MEP
FIX ED E QPMT.
FOU N D ATION

D OC K MA NAGER

DESIGN REQUIREMENTS.THE SIZES AND LOCATIONS NEED TO BE

DRAWINGS)
(REFER TO MEP
JET FAN
WAS TE R OOM R 0025
R 0024
E LEC T.RM U PS RM.
R 0022 R 0023

R7
E XTE RNAL

COORDINATED IN SHOP DRAWINGS.


E XTE RNAL
S TAIR CASE S TAIR CASE
R 0027 R 0026

m m
M AIN SE RVICE
R7 11. +4.93m NADD IS +/- 0.00LVL
P ROVIDE R RM.
R 0033

FIX ED E QPMT.
FOU N D ATION
FIX ED E QPMT. WASTE
FOU N D ATION R 0029 FIX ED E QPMT.
FOU N D ATION

FIX ED E QPMT.
M AIN S ERVICE

FOU N D ATION
TANK AND E LECT.MLV P ROVISION FOR GEN ER ATOR INTAKE
FIX ED E QPMT. P UMP ROOMS S TOR E-3 R OOM TEN ANT
R OOM A CCESS
FOU N D ATION R 0028 R 0032 R 0034 GEN ER ATOR
TANK AND R 0036 R 0037
R 0035

FIX ED E QPMT.
S ECU RITY

FOU N D ATION
P UMP ROOMS
R 0030 C ON TR OL R M.
FIX ED E QPMT R 0031
FOU N D ATION

6m
MCC FIX ED E QPMT

DRAWINGS)
1200

(REFER TO MEP
JET FAN
FIX ED E QPMT FOU N D ATION
R OOM
FOU N D ATION FIX ED E QPMT. FIX ED E QPMT.
R 0041
FOU N D ATION FOU N D ATION

2m
E6 E5

B02
1158

FL+5.00

FL+5.00
PRT ROUTE 20m

VENTILATION
OPENING ABOVE FOR
1 IB-L2

IB-L1
IB-L2
IB-L1
45°

45°

45°

IB-L2
VENTILATION
ABOVE FOR
OPENINGS

IB-L1
SC-L1

SC-L1

SC-L1

SC-L1
NEW EXIT SIGNAGE

(REFER TO MEP DRAWINGS)


JET FAN
(REFER TO MEP DRAWINGS)
JET FAN

IB-L1
SC-L1

IB
-L
IB

2
-L
SC-L1

SC-L1

1
SC-L1

SC-L1
SC-L1 IB-L1
chargingunit
CU
SC-L1
SC-L1

SC-L1

EXISTING SIGNAGE TO BE RELOCATED

IB
-L
IB

2
-L
1
SC-L1
SC-L1

SC-L1
SC-L1
10

SC-L1
SC-L1

SC-L1
SC-L1

SC-L1 SC-L1
SC-L1

SC-L1

SC-L1

SC-
SC-
SC-L1

L4
L1
SC-L1

NOT IN SCOPE
SC-L1
SC-L1

SC-L1

SC-L1
SC-L1

WT

SC-L1

SC-L1
SC-L1

SC-L1
SC-L1
SC-L1

SC-L1 SC-L1 SC-L1


SC-L1

PRT ROUTE
SC-L1
SC-L1

SC-L1

SC-L1
SC-L4
SC-L1
IB-L1 IB-L1

EXISTING PRT
STATION
SC-L1
SC-L1

SC-L1

SC-L1

(REFER TO MEP DRAWINGS)


JET FAN
SC-L1

SC-L1

SC-L1
SP.02 SC-L1 SC-L1
SC-L1

SC-L1

SC-L4

SC-L1

SC-L1
SC-L1
FL+5.00

SC-L4
SC-L1

SC-L1

SC-L1
SC-L1

SC-L1
SC-L1
SC-L1

SC-L1

SC-L1
SC-L1

SC-L1 SC-L1
SC-L1
SC-L1 SC-L1

SC-L1 SC-L1 SC-L1 SC-L1


IB-L1 IB-L1 IB-L1 IB-L1 IB-L1
PRT ROUTE

IB-L1
SC-L1

IB-L1

IB-L1
B-23

level plant room


IB-L1

Intermediate
SC-L1 SC-L1

pump room
Lower level
SC-L1
SC-L1 SC-L1 IB-L1 IB-L1 IB-L1 SC-L1
200
SC-L1 SC-L1 SC-L1 200
SC-L1 SC-L1 SC-L1 SC-L1
SC-L1

935 1000 865

FL+5.00
IB-L1
SC-L1

SC-L1
SC-L4
SC-L1

SC-L1

SC-L1

IB-L1

IB-L2
SC-L1
SC-L4
SC-L1

IB-L1

E2
SC-L1 SC-L1
SC-L1

SC-L1 SC-L1 SC-L1


SC-L1

SC-L1
SC-L1
SC-L1

SC-L1
SC-L4
SC-L1

SC-L1
SC-L1

SC-L1 SC-L1
SC-L1

B-07a
SC-L1
IB-L1

SC-L1
IB-L2
IB-L1

SC-L1
SC-L1

SC-L1
SC-L1

SC-L1
SC-L1
SC-L1
IB-L2

IB-L1

(REFER TO MEP DRAWINGS)


JET FAN
SC-L1

SC-L1

DRAWINGS)
(REFER TO MEP
JET FAN
B04 B03
IB-L2

IB-L1

SC-L1 SC-L1

meSRi ng meSRi ng FMD


(cl o se d office) (cl o se d office) (cl o se d office)
SC-L1

1 0m2
SC-L1

Detail Design Submission


8 m2 8 m2

SC-L1

DRAWINGS)
(REFER TO MEP
JET FAN
SC
SC
-L1
-L4

SC-L1

Not to be used for


SC-L1

SC-L1
IB-L1

SC-L1

Construction Purpose
(REFER TO MEP DRAWINGS)

(REFER TO MEP DRAWINGS)


SC-L1

SC-L1
OPENINGS
VENTILATION
ABOVE FOR

SC-L1
SC-L1

IB-L1 SC-L1
SC-L1 SC-L1 IB-L1
S C- L4
C-
S

L1

JET FAN

JET FAN

SC-L1

SC-L1
SC-L1

IB-L1 IB-L1 IB-L1

IB-L2 IB-L2 IB-L2


SC-L1
IB-L1

IB-L1

E4

OPENINGS
VENTILATION
ABOVE FOR
PRT ROUTE FL+5.00 PRT ROUTE FL+5.00
FL+5.00

FL+5.00
E7
E3

2.4m
650

6.5m
01 REVISED DD SUBMISSION LJ SR 19.02.2018
00 DD SUBMISSION LJ SR 21.12.2017
14.8m Rev Description Drawn Chk'd Date
Client

B-07b B11 Main Contractor

Creator

AECOM MIDDLE EAST LIMITED


P.O. Box 53, Abu Dhabi,
United Arab Emirates
BS-06

T +971 2 613 4000 F +971 2 613 4001

Project Title

MASDAR INSTITUTE NEIGHBORHOOD

Drawing Title
1 PRT ROUTE UNDERCROFT SIGNAGE PLAN - OVERALL
SCALE: 1:500 PRT ROUTE
SIGNAGE PLAN & DETAILS
File Location: MIN-ACM-B04C-AX-MO-0103_detached.rvt

Drawn Checked Approved


SRK RS ZK

Scale (A0) Date Status


1:500 19.02.2018 DD

Drawing No. Rev.

MIN-ACM-PRT-XX-AX-DD-90000 01

Printed on ___% Post-Consumer

You might also like