Bearing Capacity Calculation Based On S.P.T. Values Project Building
Bearing Capacity Calculation Based On S.P.T. Values Project Building
Bearing Capacity Calculation Based On S.P.T. Values Project Building
VALUES
Pad Footing
Maximum Column Load (kN) 440 Data
Minimum Column Load (kN) - γ (kN/m3) 18
Water Level (m) Cu (kN/m2) 35.91
Ground Level (m) Assume Width B
Formation Level (m)
Cut(+ve) / Fill (-ve) (m)
No borehole BH 4 phi Nc Nq Ng
N Value 6 0 5.14 1 0
Factor of Safety: 3
qall = 267/3
= 89.0 kN/m2