A New HEPA Solution for GT Inlet

Air Filtration

Tom Kelmartin, PE
W.L. Gore & Associates, Inc.
June 18, 2013

Frame 6 Users Group


League City, TX

tkelmart@wlgore.com

1
Agenda

• The Problem
• What is HEPA Filtration?
• Gore’s HEPA Technical Approach
• Case Studies

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 2
The Problem

• Gas turbines consume enormous amounts of air for


combustion
– GE 7FA: ~360 Billion Ft3/year
– GE 6B: ~115 Billion Ft3/year

• That air contains contaminants large and small


– Dirt, salt , moisture, sand, soot, insects, corrosive gasses….

• Dirty air causes lost efficiency and can ultimately


destroy a turbine
– Compressor fouling, blocked cooling passages, blade erosion,
low and high temp corrosion, foreign object damage

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 3
The Problem
• Inlet air filtration aims to reduce contaminants in the air
stream without imposing a large pressure drop penalty

• Conventional filters are very good at capturing large


particles

• Conventional filters are very inefficient at capturing sub-


micron particles and allow liquids and dissolved
contaminants to pass

• HEPA filters are better at capturing submicron particles,


but in the past have been challenged by relatively high
pressure drops and limited life
 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013
Tom Kelmartin 4
Overview

What is HEPA Filtration?

(High Efficiency Particulate Air)

5
Sub-Micron Distribution in Urban Air
Particle Distribution (urban)

0.9 100 times more 0.1μ particles than 0.5μ


0.8

0.7

0.6
Particle
Number 0.5
(normalized)
0.4
Visible particle = 40µ
0.3

0.2

0.1

0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Particle Size [µm]

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 6
Particle Size Range of Current
Standards
(Don’t measure below 0.3µ)
Particle Distribution (urban) US Standard
EU Standard
1

0.9

0.8
EN779
0.7

0.6
Particle
Number (normalized)
0.5
ASHRAE 52.2
0.4

0.3

0.2

0.1

0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Particle Size [µm]

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 7
HEPA Standard EN1822 Addresses <0.3
Micron Issue
Particle Distribution (urban)

0.9

0.8
EN779
0.7

0.6
Particle
Number (normalized)
0.5
ASHRAE 52.2
0.4

0.3

0.2

0.1 EN1822
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Particle Size [µm]

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 8
To Capture the Performance of HEPA Filters,
Need a Different Test (EN1822) and Scale

MPPS*

GORE H12/E12 Minimum required for H12 rating


1 100

0.9 90

0.8
MERV15/F9 80

0.7 70

0.6 60

Particle
Nanofibers / Synthetic Particle
0.5 50 Capture
Number (normalized)
Efficiency [%]
0.4
Nanofibers / Cellulose 40

*Most Penetrating Particle Size


0.3 30

0.2
Cellulose 20

0.1 10

0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Particle Size [µm]


 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013
Tom Kelmartin 9
Filter Classifications

Filter Class Efficiency Particle Size EN779 ASHRA EN1822


E 52.2 2005/2009

80% ≤ Em ≤90% 0.4μm/ F7


E1 < 0.3-1.0 avg. MERV
Fine Filters 75%
80% ≤ E ≤95% 0.4μm/ F8 13
m
75% ≤ E1 ≤85% 0.3-1.0 avg. MERV
95% ≤ Em 0.4μm/ F9 14
85% ≤ E1 ≤95% 0.3-1.0 avg. MERV
95% < E1 15
>85% MPPS MERV H10/E10
16
EPA/HEPA >95% MPPS H11/E11
Filters
>99.5% MPPS H12/E12

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 10
What is a HEPA Filter?

• Defined by EN1822 standard. Were called “H”, now “E”


ratings
• Rating is based on the minimum capture rate of the
Most Penetrating Particle Size (MPPS), typically
about 0.1 microns

HEPA Rating Efficiency at


MPPS
H10/E10 > 85%
H11/E11 > 95%
H12/E12 > 99.5%
 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013
Tom Kelmartin 11
There Are Different HEPA Ratings For a
Reason
14
29 lb/yr Representative pollutants which
12 pass through a 25 MW turbine
during one year of operation
10
Turbine will
Uncaptured
still foul
Pollutants 8
[kg/yr] 135X due to low
Best GORE®
6
12.3 lb/yr efficiency MERV Turbine
filters 15 Filter Filters
4 F9 E10
Filter Grade Filter Grade
(MERV 15)
2

X= 0.09 lb/yr

F9 H10 E12 GORE® Turbine Filter

Filter Grade

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 12
GORE® Turbine Filters: High Efficiency (E12)
with Low Pressure Drop

Pre-filter Layer removes


Bulk of large Particles

High Efficiency Membrane Removes


Submicron Dust, Water, and Salt

High Strength Backer


Provides Burst Strength

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 13
GORE Membrane Technology
Waterproof Media Provides Water & Salt Retention

Salt dust, water, and aqueous salt


solutions are repelled

Air can pass


through the membrane

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 14
Panel Filter Case Study – BASF, Geismar
LA

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 15
Panel Filter Case Study – BASF, Geismar
LA

• Objective: Determine the


effectiveness and service
lifetime of an E12 HEPA inlet
filter system
– V-Panel style

• GE 6B, base loaded


• Heavy industrial, agricultural,
coastal (Mississippi River)
• 120 Gore “V-Panel” filters,
MERV12 pre-filter with a
disposable G2 coarse pad

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 16
Panel Filter Case Study – BASF, Geismar
LA

• On-line data collection for


filter flow and individual filter
stage DP
• Installed May 2011 and
continuing

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 17
Panel Filter Case Study – BASF, Geismar
LA

• On-line data collection for


filter flow and individual filter
stage DP
• Installed May 2011 and
continuing

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 18
BASF Geismar LA, Frame 6B
(Data Courtesy BASF/JC Rawls)
Compressor Efficiency
100 10.00

90 9.00

80 8.00

Inlet Temp °F
70 7.00

60 6.00
Eff%, DegF, Pwr MW

η comp
MW Predicted

DP Inch H2O
50 Predicted MW 5.00 MW Actual
T-Inlet
DP Inlet
40 4.00

30 3.00
Actual MW Inlet Filter DP
20 2.00

10 1.00

0 0.00
7/10/12 12:00 8/29/12 12:00 10/18/12 12/7/12 12:00 1/26/13 12:00 3/17/13 12:00 5/6/13 12:00 6/25/13 12:00
AM AM 12:00 AM AM AM AM AM AM

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 19
BASF Geismar Filter DP (Inch WG)

G2 Change
G2 Change
G2 Change Prefilter and G2 Total DP
G2 Change
Change
MERV12 Prefilter
G2 Change
+G2 Wrap

G2 Wrap

V-Panel

Continuing Ops
2 Years

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 20
G2 Wrap Change-out (Inch WG)
Change-out

Total DP
V-Panel
Prefilter + G2
G2

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 21
Observations from BASF-Geismar

• HEPA filter system has succeeded in


keeping the compressor efficiency and
power output steady
• Maintenance of pre-filters is effectively
protecting V-panels, extending lifetime
• Regularly scheduled off-line washes no
longer required, on-line washing
eliminated
• Filter replacement frequency reduced
 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013
Tom Kelmartin 22
Cartridge Filter Case Study
– Chevron, El Segundo CA

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 23
Cartridge Filter Case Study
– Chevron, El Segundo CA

• Objective: Determine the


effectiveness and service
lifetime of an E12 HEPA inlet
filter system
– Cartridge (cylindrical) style

• GE 6B, base loaded


• Heavy industrial, urban, coastal
(Pacific Ocean)
• 448 Gore cartridge filters with
coalescing wrap

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 24
Chevron El Segundo CA, Frame 6B
(Data Courtesy Chevron/Mike Wenschlag)

GT Upgrade
100 5
Filter Eff
Comp Approaching End of Service Lifetime
90 4.5

80 4

70 3.5

DP Inch WG
Comp Eff %

60 Filter Approaching End 3


GT Upgrade of Service Lifetime
50 2.5

40 2

30 1.5

20 DP 1

10 0.5

0 0
8/10/2010 2/26/2011 9/14/2011 4/1/2012 10/18/201 5/6/2013 11/22/201
0:00 0:00 0:00 0:00 2 0:00 0:00 3 0:00

2 Years Continuing Ops

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 25
Chevron El Segundo CA, Frame 6B
(Data Courtesy Chevron/Mike Wenschlag)

A-Train Raw MW

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 26
Observations from Chevron-El
Segundo
• Compressor efficiency and power output
steady
• 2 years+ HEPA filter lifetime achieved
• Need for off-line washes greatly
diminished
• Impact of moisture/fog on filter DP very
minor during first 2 years of operation
– Frequent DP spikes during fog events
indicates nearing end of filter service life
 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013
Tom Kelmartin 27
Coastal Petrochemical Plant (Texas)
(Courtesy ExxonMobil-Greg Polasek)

GORE® E12 Turbine


Filters With
Coalescers

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 28
Petrochemical Plant (GE Frame 6B - 35MW)
(Courtesy ExxonMobil-Greg Polasek)

8,000+ hrs
No Wash Frame 6B

Compressor Efficiency

Power Load

Temperature

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 29
Petrochemical Plant (GE 6B – 35MW) – Texas
(Data Courtesy ExxonMobil-Greg Polasek)
GE Frame 6B 7,850 Hrs

34.4 MW (GORE)
31.0 MW (F8)
Power Load 3.4 MW Gain

Compressor Efficiency
90.2% (GORE)

87.6% (F8)

2.6% Gain

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 30
Should I Invest in HEPA Filtration?
1. Compare power output versus previous experience.
Power output will be effectively constant. Will this
reduce the need to purchase power?
2. Quantify value of stopping off-line washes
(availability, cost of shutdown with no power output).
3. Quantify value of constant heat rate versus previous
increases, fuel savings
4. Compare reduced costs due to elimination of
extensive compressor section cleaning during
scheduled major maintenance
5. Measure blade or rotor corrosion rates over time.

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 31
Annual Power Replacement Cost
(8,000 Hours)

1800
1600 $80/MWHr
1400
1200 $60/MWHr
$1,000's

1000
800 $40/MWHr
600
400 $20/MWHr
200
0
0 1 2 3 4 5
MW Lost Between Washes

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 32
Annual Power Replacement Cost
(8,000 Hours)

1800
1600 $80/MWHr
1400
1200 $60/MWHr
$1,000's

1000
800 $40/MWHr
600
400 $20/MWHr
200
0
0 1 2 3 4 5
MW Lost Between Washes

For Example: 3MW loss at $40/MWHr replacement cost = $480,000 annual cost

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 33
Should I Invest in HEPA Filtration?
1. Compare power output versus previous experience.
Power output will be effectively constant. Will this
reduce the need to purchase power?
2. Quantify value of stopping off-line washes
(availability, cost of shutdown with no power output).
3. Quantify value of constant heat rate versus previous
increases, fuel savings
4. Compare reduced costs due to elimination of
extensive compressor section cleaning during
scheduled major maintenance
5. Measure blade or rotor corrosion rates over time.

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 34
New V-Panel design – resulted from customer feedback during trials

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 35
GORE HEPA Turbine Filters Eliminate
®

Compressor Fouling:
Simple retrofit
• Similar initial pressure drop
• Similar filter life

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 36
Acknowledgements

• JC Rawls

• Mike Wenschlag

• Greg Polasek/Jeff Gillis

 2013 W. L. Gore & Associates Frame 6B User’s Conference/June 2013


Tom Kelmartin 37
Thank-you!

MORE POWER, LESS


WEAR

W. L. Gore & Associates GmbH W. L. Gore & Associates, Inc.


Wernher-von-Braun-Str. 18 • D-85640 Putzbrunn • 101 Lewisville Road • Elkton, MD 21921 • USA
Germany Phone: +1 410 506-3300 • Fax: +1 410 506-3494
Phone: +49 89 4612-2211 • Fax: +49 89 4612-2302
W. L. Gore & Associates GmbH Middle East - Abu
E-mail: turbinefilters@wlgore.com
Dhabi
www.gore.com Al Niyadi Building • Airport Road • Abu Dhabi • UAE
Phone: +971 2 4437749 • Fax: +971 2 4437748

38

You might also like