Test Of
Three Phase Induction Motor
[https://sah786.wordpress.com]or[www.slideshare.net/SaHussain1]
•CONTAINE
Concept Behind Direct And Indirect
1. NO LOAD TEST
CIRCUIT DIAGRAM
PROCEDURE
OBSERVATION TABLE
2. BLOCKED ROTOR TEST
CIRCUIT DIAGRAM
PROCEDURE
OBSERVATION TABLE
3. CONCLUSION
4. REFRENCES
[https://sah786.wordpress.com]or[www.slideshare.net/SaHussain1]
Concept Behind Direct And Indirect
Test Of Three Phase Induction Motor
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
1. NO LOAD TEST :
By the name no load test it means that there is no
load- that is load is zero.
In this test, the motor is allowed to run with no-load
at the rated voltage of rated frequency across its
terminals.
Machine will rotate at almost synchronous speed,
which makes slip nearly equal to zero.
The no load parameters can be found from the
voltmeter, ammeter, and wattmeter readings obtained
when the machine is run at no load as shown below:
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
•Circuit Diagram of no Load Test
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
•PROCEDURE:
1. Determine the meters and their ratings based on the
name plate readings of the machine and requirement.
2. Connect the circuit as shown in Fig.
3. Set/check the variac to be at zero output.
4. First switch on the 3ф supply.
5. Gradually increase the voltage applied to the
machine to the rated voltage. Motor runs at a speed
quite close to its synchronous speed.
6. Take the reading of voltmeter, ammeter ,wattmeter&
speed on that particular voltage on the variac and
[https://sah786.wordpress.com]or[www.sli
make a table. deshare.net/SaHussain1]
•OBSERVATION TABLE:
Pin = √3VLILcosφ
Cosφ = power factor
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
2. BLOCKED ROTOR TEST :
In the blocked rotor test,
the rotor is locked. A low
voltage is applied on the
stator terminals so that there
is full load current in the
stator winding, and the
current, voltage and power
input are measured at that
point. When the rotor is
stationary,
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
Circuit Diagram of Blocked rotor test :
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
PROCEDURE:
1. Determine the meters ratings based on the name plate
readings .
2. Connect the circuit as shown in Fig.
3. Set/check the variac to be at zero output.
4. First switch on the 3ф supply.
5. Now, keeping the rotor still slowly increase the
autotransformer output until rated current flows .
6. Take the ammeter, voltmeter, and wattmeter readings and
tabulate.
8. Repeat the procedure for other values stator phase current
less than the rated value.
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
•OBSERVATION TABLE:
Pin = √3VLILcosφ
Cosφ = power factor
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
In blocked rotor test, rotor is not allowed to rotate
so the speed of the rotor is zero r.p.m, slip
corresponding to zero speed is unity. Now, increase
the stator voltage till motor current reaches to its
rated value. Note down the readings of voltmeter,
ammeter, wattcmeters and tachometer at different
stator voltages
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
•REFRENCES:
http://electrical4u.com/losses-and-efficiency-of-induction-motor
http://ABB.co.in
http://electrical-engineering-portal.com
Electrical Technology, Volumn-2 , BY: B.L.Theraja.
Electrical Machine-2, by R.P.AJWALIA
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]
•CONCLUSION:
[https://sah786.wordpress.com]or[www.sli
deshare.net/SaHussain1]