ORM.) Engineers: India Limited Ladder Rungs For Manhole / Demister
ORM.) Engineers: India Limited Ladder Rungs For Manhole / Demister
ORM.) Engineers: India Limited Ladder Rungs For Manhole / Demister
TOP OF DEMISTER
.!.!..t.!-:•!•,..:•!•!•!•!•:•:•!•!•!>!•!•!•!•:•!•!•!•!•:-!•!•!•:•'."_?..
HORIZONTAL VESSEL
175 175
MANHOLE Q
ti
200
DETAIL—X
DETAIL—X
175 175
20(16)RODFI
VERTICAL VESSEL C.S. AND LOW ALLOY
STEEL (NOTE-7)
20R
HANDGRIP
NOTES
1. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED.
• 2. VARIATION IN SPACING BETWEEN LADDER RUNGS IS PERMITTED
IN CASE OF INTERFERENCE WITH SOME NOZZLE OR INTERNALS.
HOWEVER THE SPACING OF RUNGS SHALL BE EQUAL.
3. SQUARE RODS MAY BE USED FOR HANDGRIP / LADDER RUNGS.
IF FABRICATED FROM PLATE THE EDGES ARE TO BE ROUNDED OFF.
4. MATERIAL SHALL BE AS PER ENGINEERING DRAWING.
5. ALL FILLET WELDS SHALL BE 6 mm MINIMUM.
6. ORIENTATION OF LADDER RUNGS SHALL BE SAME AS OF MANHOLE.
7. DIMENSIONS SHOWN IN BRACKETS ARE FOR STAINLESS STEEL MATERIAL.
gi-
6 31.10.2016 REAFFIRMED AND REISSUED AS STANDARD JIT SING SK/KJH Rif RN
5 30.06.2011 REAFFIRMED AND REISSUED AS STANDARD POREL RKT AKM/SC DM