RATINGS & STANDARDS

ENGINE RATINGS AND FUEL CONSUMPTION


2
ISO STANDARD (CONTINUOUS) POWER RATINGS FOR MODEL 16V-AT27GL
ELECTRIC POWER GENERATION (EPG)
90°° F (32°° C) AUXILIARY WATER TEMPERATURE
180°° F (82°° C) JACKET WATER TEMPERATURE

P a rt L o a d F u e l C o n s u m p tio n
W a s te g a te s S e t F o r C o n tin u o u s P o w e r R a tin g

8000

7800 11000

7600

7400 10500

7200
10000
7000

6800
1000 RPM 9500
6600

6400
9000

6200 900 RPM

6000 8500
1500 2000 2500 3000 3500 4000 4500 5000

BHP

RPM 900 1000


CONTINUOUS BHP 4171 4500
OVERLOAD BHP 4350 4833

OVERLOAD Allowed 2 Hours Per 24 Hours


Barometer Ambient Temperature
STANDARD CONDITIONS
29.54 in. Hg. (100 kPa) 77° F (25° C)
Altitude: For 900 RPM – Contact Waukesha Sales Engineering above 1000 ft (305 m)
For 1000 RPM – 4.1 Percent per 1000 ft (305 m) above 2000 ft (610 m)
DEDUCTIONS
Ambient Temperature: For 900 RPM – Contact Waukesha Sales Engineering above 77° F (25° C)
For 1000 RPM – 3.4 Percent per 10° F (5.5° C) above 100° F (38° C)
Dry Natural Gas – 900 Btu/ft3 (35.38 MJ/m3) SLHV; 91 WKIä
FUEL
Refer to S-7884-7 for Full Fuel Specification
EQUIPMENT Engine Equipped with Lube Oil and Cooling Water Pumps but without Radiator Fan
ENGINE DATA Turbocharged & Intercooled with 90° F (32° C) Auxiliary Water – 9.0:1 Compression Ratio
NOTES:
o
1. Engine set to an exhaust oxygen concentration of 11.2% at rated speed and load at standard 22 BTDC timing.
Reference S-9052-4.
2. ISO Standard (continuous) power ratings conform to ISO 3046/1, latest version, with a mechanical efficiency of 90%
and Tcra of 90° F (32° C) limited to ± 10° F (± 5.5° C).
Page 1 of 1

ENGINE RATINGS AND FUEL CONSUMPTION Ref.


MODEL 16V-AT27GL — EPG EN: 126446
90°° F (32°° C) AUX. WATER TEMPERATURE C
DATE: 1/02
180°° F (82°° C) JACKET WATER TEMPERATURE 1016-7