SUKKUR IBA University Kandhkot campus

RENOVATION WORK
AT DO OFFICE KANDHKOT

MEASUREMENT SHEET
S.No Particulars No.s Length Width Height Quantity (S.I) UNIT

1 DISMANTELLING

1.1 REMOVING/CHIZZLING OF PLASTER or wall TILES


class rooms & labs - 06 nos
long walls 12 30 9 3240
short walls 12 19 9 2052
girls commom room
long walls 2 16.33 9 293.94
short walls 2 14.42 9 259.56
Room 1 , 2& Meeting
long walls 6 20 9 1080
short walls 6 12.83 9 692.82
HODs rooms ( both long & short walls) 2
rooms 8 16.33 9 1175.76
director 's, teachers , R-3 &R-4 9
LONG WALLS 8 23.33 9 1679.76
short walls 8 20 9 1440
R-5.R-6,R-7 & R-8
long walls 8 22 9 1584
short walls 8 18 9 1296
class rooms corridoor
along the classes 1 125.16 9 1126.44
HODs Corridoor
along the offices 1 53.42 9 480.78
stair case portion
INNER PORTION
long walls 2 20.67 9 372.06
short walls 1 5.92 9 53.28
OUTER SIDES/ stair tower
Long walls 2 22.33 8 357.28
short walls 2 13.83 8 221.28
director's corridoor
along the offices 1 151.5 9 1363.5
outer side above the columns 1 151.5 5.83 883.245
columns all four sides (12"x17") i.e perimeter=
4'-10") 12 4.83 8 463.68
columns all four sides (17"x17") i.e perimeter=
5'-8") 10 5.66 8 452.8
Room 5 & 6 corridoor
along the offices 1 38.16 9 343.44
outer side above the columns 1 38.16 6.08 232.0128
columns all four sides (17"x17") i.e perimeter=
5'-8") 7 5.66 6.92 274.1704
Room 7 & 8 corridoor
along the offices 1 47.67 8 381.36
outer side above the columns 1 47.67 6.08 289.8336
columns all four sides (17"x17") i.e perimeter=
5'-8") 7 5.66 6.92 274.1704
Boundary wall
At the fornt of building(including stip/columns) 2 305.5 7.92 4839.12
At the back/side of office 2 183.25 7.92 2902.68
at back side of classes 2 212.67 7.92 3368.6928
SUM of PLASTER 33473.665
DEDUCTION
door 6 4.42 6.75 179.01
door 18 4 6.75 486
windows 14 5 4 280
windows 27 4 4 432
TOTAL of Plaster removing 32096.655 Sft
WASHRROOMS DISMENTALNG walls and roof
07 Blocks of 2 two washroom each
1.2 Perimeter wall(outerof both washrooms) 7 24 8.42 1414.56 sft
1.2 Inner wall 7 5 8.42 294.7 sft
1.4 floor 7 17 5 595 sft
1.3 Roof 7 18 6 0.5 378 cft
1.2 hand rail parapet ( both sides) 2 22.92 3.42 156.7728 sft
1.5 removal of roof treated material
from director , teachers room,R-3 &R-4 1 91.92 28 2573.76
Room NO 7,8 1 47.67 26 1239.42
Room NO 5,6 1 38.16 28 1068.48
class rooms & labs - 06 nos 1 125.16 38 4756.08
Total 9637.74 SFT
1.6 removal of floor tiles
along class corridoor 1 125.16 1 125.16
along hods corridor 1 53.42 1 53.42
along directors corridor 1 151.5 1 151.5
along R-5&6 1 38.16 1 38.16
along R-7&8 1 47.67 1 47.67
Total of tile removal 415.91 SFT

2 PLASTERING
class rooms & labs - 06 nos
long walls 12 30 9 3240
short walls 12 19 9 2052
girls commom room
long walls 2 16.33 9 293.94
short walls 2 14.42 9 259.56
HODs rooms ( both long & short walls) 2
rooms 8 16.33 9 1175.76
Room 1 , 2& Meeting
long walls 6 20 9 1080
short walls 6 12.83 9 692.82
director 's, teacher's , R-3 &R-4
LONG WALLS 8 23.33 9 1679.76
short walls 8 20 9 1440
R-5.R-6,R-7 & R-8
long walls 8 22 9 1584
short walls 8 18 9 1296
class rooms corridoor
along the classes 1 125.16 9 1126.44
HODs Corridoor
along the offices 1 53.42 9 480.78
stair case portion
INNER PORTION
long walls 2 20.67 9 372.06
short walls 1 5.92 9 53.28
OUTER SIDES/stair tower
Long walls 2 22.33 8 357.28
short walls 2 13.83 8 221.28
director's corridoor
along the offices 1 151.5 9 1363.5
outer side above the columns 1 151.5 5.83 883.245
columns all four sides (12"x17") i.e perimeter=
4'-10") 12 4.83 8 463.68
columns all four sides (17"x17") i.e perimeter=
5'-8") 10 5.67 8 453.6
Room 5 & 6 corridoor
along the offices 1 38.16 9 343.44
outer side above the columns 1 38.16 6.08 232.0128
columns all four sides (17"x17") i.e perimeter=
5'-8") 7 5.67 6.92 274.6548
Room 7 & 8 corridoor
along the offices 1 47.67 9 429.03
outer side above the columns 1 47.67 6.08 289.8336
columns all four sides (17"x17") i.e perimeter=
5'-8") 7 5.67 6.92 274.6548
back & both sides/outer of classes walls 1 187.75 4 751
back/ outer of HODs block 1 52.33 4 209.32
back & sides/outer of directors corridor 1 199.92 4 799.68
back & sides of two blocks 2 88.25 4 706
parpet wall at directors corridor 2 91.16 4.5 820.44
Boundary wall
At the fornt of building 2 305.5 7.92 4839.12
At the back/side of office( R-7, 8) 2 183.25 7.92 2902.68
at back side of classes 2 212.67 7.92 3368.6928
top of boundary walls 1 701.42 0.75 526.065
Sum of Plaster 37335.6088
DEDUCTION
door 6 4.42 6.75 179.01
door 18 4 6.75 486
windows 14 5 5 350
windows 27 4 4 432
Total of PLASTERING 35888.5988 SFT

3 Plain cement concrete


claas rooms portions 1 125.16 39.16 0.25 1225.3164
HOD s portion 1 53.42 25.25 0.25 337.21375
director offices portions 1 104.5 29 0.25 757.625
R-5,6 Portion 1 38.16 27.83 0.25 265.4982
R-7,8 Portion 1 47.67 25 0.25 297.9375
TOTAL 2883.59085 CFT
4 RCC (3000psi)
9" High and 6" wide beams below partation walls
Hod's 2 nos 2 16.33 0.5 0.75 12.2475
R-3 & R-4
wall 1 2 19.08 0.5 0.75 14.31
wall 2 2 15.08 0.5 0.75 11.31
R-5 & R-6
wall 1 2 18.33 0.5 0.75 13.7475
wall 2 2 15.25 0.5 0.75 11.4375
R-7 & R-8
wall 1 2 18.33 0.5 0.75 13.7475
wall 2 2 15.25 0.5 0.75 11.4375
slab over sever/drainline@ entrance 3 11 2.5 0.5 41.25
TOTAL 88.2375 cft

5 STEEL
Rcc work (2%) 0.4 tons

National tera cota tile with grey


7 color combination
infornt of Directors corridoor
colunms face 12 1.42 7 119.28
colunms face 10 1 7 70
above the coulms 1 151.5 5.83 883.245
infornt of R-5,6
colunms face 7 1.42 6.92 68.7848
above the coulms 1 38.16 6.08 232.0128
infornt of R-7,8
colunms face 7 1.42 6.92 68.7848
above the coulms 1 47.67 6.08 289.8336

Total of national tile 1731.941 SFT

8 PORCELAIN CERAMIC TILES


along class corridoor 1 125.16 1 125.16
along hods corridor 1 53.42 1 53.42
along directors corridor 1 151.5 1 151.5
along R-5&6 1 38.16 1 38.16
along R-7&8 1 47.67 1 47.67
Total of tile 415.91 sft
random quantity for broken tiles that need to
changed 500 sft
9 PORCELAIN CERAMIC TILE SKIRTING 6"
class rooms & labs - 06 nos
long walls 12 30 360
short walls 12 19 228
girls commom room
long walls 2 16.33 32.66
short walls 2 14.42 28.84
HODs rooms (2 rooms) 8 16.33 130.64
room no 1,2 & meeting
LONG WALLS 6 20 120
short walls 6 12.83 76.98
director 's, teachers , R-3 &R-4
LONG WALLS 8 23.33 186.64
short walls 8 20 160
R-5.R-6,R-7 & R-8
long walls 8 22 176
short walls 8 18 144
class rooms corridoor
along the classes 1 125.16 125.16
columns side (3 sides) 48 1 48
HODs Corridoor
along the offices 1 53.42 53.42
columns side (3 sides) 21 1 21
stair case portion
long walls 2 20.67 41.34
short walls 1 5.92 5.92
director's corridoor
along the offices 1 151.5 151.5
columns side (3 sides) 30 1 30
columns side (3 sides) 36 1.42 51.12
Room 5 & 6 corridoor
along the offices 1 38.16 38.16
columns side 21 1.42 29.82
Room 7 & 8 corridoor
along the offices 1 47.67 47.67
columns side 21 1.42 29.82
Total 2316.69 rft

10 GYPSUM TILES FALSE CEILING


CLASS ROOMS 4 30 19 2280
Labs - 2N0s 2 30 19 1140
girls common room 1 16.33 14.42 235.4786
HODs offices 2 16.33 16.33 533.3378
teacher's common room 1 20 12.83 256.6
room no 1& 2 2 20 12.83 513.2
director's & teachers room 2 23.33 20 933.2
room no 3 & 4 2 23.33 20 933.2
room no 5 , 6 ,7 & 8 4 22 18 1584
class rooms corridoor 1 125.16 5.92 740.9472
HODs Corridoor 1 53.42 5.92 316.2464
stair case portion 1 20.67 11.83 244.5261
director's corridoor 1 151.5 5.92 896.88
room 5 & 6 corridoor 1 38.16 6.25 238.5
room 7 & 8 corridoor 1 47.67 6.25 297.9375
Total 11144.0536 SFT
12 STEPS
Treads 19 5.5 1 104.5
Riser 20 5.5 0.5 55
landing 1 5.92 5.5 32.56
STEPS AT LAVATORY BLOCKS ENTRANCE
Treads 12 4 1 48
Riser 13 4 0.5 26
Total 266.06 SFT

13 hand rail 100 rft

15 PAINT (on walls)


class rooms & labs - 06 nos
long walls 12 30 10 3600
short walls 12 19 10 2280
girls commom room 0
long walls 2 16.33 10 326.6
short walls 2 14.42 10 288.4
HODs rooms ( both long & short walls) 2
rooms 8 16.33 10 1306.4
Room 1,2& meeting 0
long walls 6 20 10 1200
short walls 6 12.83 10 769.8
director 's, teachers , R-3 &R-4
LONG WALLS 8 23.33 10 1866.4
short walls 8 20 10 1600
R-5.R-6,R-7 & R-8
long walls 8 22 10 1760
short walls 8 18 10 1440
class rooms corridoor
along the classes 1 125.16 10 1251.6
Inner side of corridoor a bove the columns 1 125.16 1 125.16
3 side of columns 48 1 8 384
HODs Corridoor
along the offices 1 53.42 10 534.2
Inner side of corridoor a bove the columns 1 53.42 1 53.42
3 side of columns 21 1 8 168
stair case portion 0
long walls 2 20.67 10 413.4
short walls 1 5.92 10 59.2
OUTER SIDES 0
Long walls 2 22.33 8 357.28
short walls 2 13.83 8 221.28
director's corridoor
along the offices 1 151.5 10 1515
Inner side of corridoor a bove the columns 1 151.5 1 151.5
3 side of columns 48 1.42 8 545.28
3 side of columns 30 1 8 240
Room 5 & 6 corridoor 0
along the offices 1 38.16 10 381.6
Inner side of corridoor a bove the columns 1 38.16 1 38.16
3 side of columns 21 1.42 8 238.56
Room 7 & 8 corridoor 0
along the offices 1 47.67 10 476.7
Inner side of corridoor a bove the columns 1 47.67 1 47.67
3 side of columns 21 1.42 8 238.56
Boundary wall
At the fornt of building 2 305.5 7.92 4839.12
At the back/side of office( R-7, 8) 2 183.25 7.92 2902.68
at back side of classes 2 212.67 7.92 3368.6928
SUM OF PAINT 34988.6628 SFT
DEDUCTION
door 6 4.42 6.75 179.01
door 18 4 6.75 486
windows 14 5 5 350
windows 27 4 4 432
TOTAL 33541.6528 SFT

16 DOORS(Wooden)
D -1 doors(4.42 x6.75) 6 4.42 6.75 179.01
D-2 doors(4 x6.75) 22 4 6.75 594
D-3 doors(3x6.75) 16 3 6.75 324
D-4 doors washrooms( 2.5 x6.75) 15 2.5 6.75 253.125
TOTAL 1350.135 SFT

girll windows & doors


STAIR CASE DOOR 1 4.42 6.75 29.835
opening girll at stair case (traingular ) 0.5 4.25 3 6.375
Total 36.21 SFT

17 ALUMINIUM OPENABLE GLASS WINDOWS


W-1 windows ( 5 x 4) 20 5 4 400
W-2 windows ( 4 x 4) 35 4 4 560
W-3 windows ( 2.5x 4) 8 2.5 4 80
Total 1040 SFT

18 PLINTH PROTECTION
classs block 3 sides 1 203.5 2 407
HODs , R-1,2and meeting rooms block 1 79.08 2 158.16
director's, teachers,offices block 1 86 2 172
offices block 1 92.16 2 184.32
offices block 1 91.67 2 183.34
Total 1104.82 SFT
19 OH fabric tank of 5000 gallons 3 5000 15000 Gallons
Electric Motors with bore for drinking water 2 2 2 nos

20 ROOF TREATMRNT
claas rooms portions 1 125.16 39.16 4901.2656
HOD s portion 1 53.42 25.25 1348.855
director offices portions 1 151.5 29 4393.5
R-5,6 Portion 1 38.16 27.83 1061.9928
R-7,8 Portion 1 47.67 25 1191.75
Total 12897.3634 sft

21 CANOPY/guard cabin wooden 6×6 2 2 NOS

28 Filling/ Backfiiling 1 185.16 39.37 2.5 18224.373


1 90 45.33 2.5 10199.25
1 31.5 5.24 2.5 412.65
Total 28836.273 SFT

MAIN Gate repair work include purchasing


,fixing of iron door , color and Complete With
22 all respects 1 20 8 160
emergency exit 1 6 8 48
Total 208 SFT

23 WOODEN PARTION WALLS@ Teachers offices 1 60 5.5 330 SFT


24 IBA Sign/logo boards 2 6 4 48 SFT
25 angle MS sheet frame 1 10 10 100 SFT
26 SHEAR CRACK TREATMENT 1 100 100 RFT

LAVATORY BLOCKS
27 Excation
staff block
below 9" thick walls 1 76.67 1.83 3.5 491.07135
below 4.5 " thick wall 1 25 1 3.5 87.5
boys block 0
below 9" thick walls 1 63.42 1.83 3.5 406.2051
below 4.5 " thick wall 1 15 1 15
female block
below 9" thick walls 1 50.25 1.83 3.5 321.85125
below 4.5 " thick wall 1 15 1 3.5 52.5
Total 1374.1277 CFT
28 BACK FILLING
staff block
below 9" thick walls 1 76.67 1.83 3.5 491.07135
below 4.5 " thick wall 1 25 1 3.5 87.5
boys block 0
below 9" thick walls 1 63.42 1.83 3.5 406.2051
below 4.5 " thick wall 1 15 1 15
female block
below 9" thick walls 1 50.25 1.83 3.5 321.85125
below 4.5 " thick wall 1 15 1 3.5 52.5
sum of backfilling 1374.1277 CFT
DEDUCTION
Soling 119.00805
lean 78.545313
Brick masnory
18" thick
13" thick 2 10.5 1.25 5 131.25
9" thick 7 6 1.25 5 262.5
4.5" thick
deduction 591.303363
total of back filling 782.824337 CFT

29 Soling
staff block
below 9" thick walls 1 76.67 1.83 0.5 70.15305
below 4.5 " thick wall 1 25 1 0.5 12.5
boys block 0
below 9" thick walls 1 63.42 1.83 0.5 58.0293
below 4.5 " thick wall 1 15 1 0.5 7.5
female block
below 9" thick walls 1 50.25 1.83 0.5 45.97875
below 4.5 " thick wall 1 15 1 0.5 7.5
Total 119.00805 CFT

3.1 lean(pcc)
staff block
below 9" thick walls 1 76.67 1.83 0.33 46.301013
below 4.5 " thick wall 1 25 1 0.33 8.25
boys block 0
below 9" thick walls 1 63.42 1.83 0.33 38.299338
below 4.5 " thick wall 1 15 1 0.33 4.95
female block
below 9" thick walls 1 50.25 1.83 0.33 30.345975
below 4.5 " thick wall 1 15 1 0.33 4.95
Total 78.545313 CFT
4 RCC
strip coulnms at washroom face 12 1 0.5 2.438 14.628
Plinth beams
staff block
9" thick walls 1 76.67 1.08 1 82.8036
4.5 " thick wall 1 25 0.75 0.75 14.0625
Boys block 0
9" thick walls 1 63.42 1.08 1 68.4936
4.5 " thick wall 1 15 9 0.75 101.25
female block
9" thick walls 1 50.25 1.08 1 54.27
4.5 " thick wall 1 15 9 0.75 101.25
Lintel/ Roof beam
staff block
9" thick walls 1 76.67 1 1 76.67
4.5 " thick wall 1 25 0.375 6 56.25
Boys block 0
9" thick walls 1 63.42 1 1 63.42
4.5 " thick wall 1 15 0.375 6 33.75
female block
9" thick walls 1 50.25 1 1 50.25
4.5 " thick wall 1 15 0.375 6 33.75
Slab
staff block 1 14.5 21.16 0.5 153.41
1 9.1 6.75 0.5 30.7125
boys block 1 20.33 16 0.5 162.64
female block 1 23 10.25 0.5 117.875
Slab blocks @3' height in the washroom 3 7 2 0.5 21
Total 1236.4852 CFT

5 Steel (2%) 5.5 TONS


6 Brick masnory
6.4 18" thick
staff block 1 76.67 1.33 101.9711
boys block 1 63.42 1.33 84.3486
female block 1 50.25 1.33 66.8325
Total 253.1522 SFT
6.3 13" thick
staff block 1 76.67 3.33 255.3111
1 25 1.33 33.25
boys block 1 63.42 3.33 211.1886
1 15 1.33 19.95
female block 1 50.25 3.33 167.3325
1 15 1.33 19.95
Total 706.9822 SFT
6.2 9" thick
staff block 1 76.67 9 690.03
1 25 3.33 83.25
boys block 1 63.42 9 570.78
1 15 3.33 49.95
female block 1 50.25 9 452.25
1 15 3.33 49.95
total 1896.21 SFT
6.1 4-1/2" thick
staff block 1 25 9 225
boys block 1 15 9 135
female block 1 15 9 135
total 495 SFT

2 Plaster
staff block
9" thick walls 2 76.67 9
4.5 " thick wall 2 25 9 450
Boys block
9" thick walls 2 63.42 9 1141.56
4.5 " thick wall 2 15 9 270
female block
9" thick walls 2 50.25 9 904.5
4.5 " thick wall 2 15 9 270
Total 3036.06 SFT

11 WALL Tiles
staff block 4x 6 6 20 4 480
covered portion perimeter 1 38 4 152
boys block washrooms 4x 6 4 20 4 320
lavatory potion covered 1 56.67 4 226.68
female blocks washroom 4 x6 3 20 4 240
lavatory potion covered 1 36 4 144
Total 1562.68 SFT
3 PLAIN CEMENT CONCRETE ( flooring /c.c)
staff block 1 21.16 14.5 0.5 153.41
boys block 1 20.33 16 0.5 162.64
female block 1 23.25 10.25 0.5 119.15625
Total 435.20625 CFT

8 FLOOR Tiles
staff block 1 21.16 14.5 306.82
boys block 1 20.33 16 325.28
female block 1 23.25 10.25 238.3125
Total 870.4125 SFT

14 Celling paint
staff block 1 21.16 14.5 306.82
boys block 1 20.33 16 325.28
female block 1 23.25 10.25 238.3125
Total 870.4125 SFT

15 Wall paint
staff block
9" thick walls 2 76.67 9
4.5 " thick wall 2 25 9 450
Boys block
9" thick walls 2 63.42 9 1141.56
4.5 " thick wall 2 15 9 270
female block
9" thick walls 2 50.25 9 904.5
4.5 " thick wall 2 15 9 270
Total 3036.06 SFT

20 Roof Treatment
staff block 1 21.16 14.5 306.82
boys block 1 20.33 16 325.28
female block 1 23.25 10.25 238.3125
Total 870.4125 SFT

SEVERAGE LINES
27 EXCAVATION
Tank area 1 22.96 14.75 5 1693.3
underground chanel 1 100 3.6 4.5 1620
surface drain 1 100 2 2 400
Total 3713.3 CFT
29 Soling
under the tank area 1 22.96 14.75 0.5 169.33 CFT

3.1 lean
under the tank area 1 22.96 14.75 0.33 111.7578
under the channel 1 100 3.6 0.33 118.8
under the surface drain 1 100 2 2 400
Total 630.5578 CFT

3 Plain concrete 3000psi


under the channel 1 100 1.5 0.5 75
under the surface drain circular shape 1 100 0.16 16
TOTAL 91 CFT

4 RCC concrete
Raft below tank 1 22.96 14.75 0.5 169.33 CFT
5 steel 2% 0.5 TONS

6 Brick Masnory
6.2 9" thick
the tank area long wall 2 22.96 4.5 206.64
short wall 2 14.75 4.5 132.75
channel 2 100 2.5 500
Total 839.39 SFT
6.1 4.5" THICK
surface drain 2 100 1.25 250 SFT

2 plaster
the tank area long wall 2 22.96 4.5 206.64
short wall 2 14.75 4.5 132.75
channel 2 100 2.5 500
surface drain 2 100 1.25 250
total 1089.39 SFT

30 Grating mesh over surface drain 1 100 100 RFT


SUKKUR IBA University Kandhkot campus
RENOVATION WORK
BILL OF QUANTITIES - Electrical work
S.N DESCRIPTION UNIT Qty RATE
B. ELECTRICAL WORK

A WIRING/ WIRING ACCESSORIES

Supply, installation, testing & commissioning of following


items including all material, tools, labour & accessories
required for completion of work as per description / drawings.
Complete in all respects.

Circuit wiring from DB to switch board with 2 x 2.5 sq. mm.


a + ECC 1 x 2.5 sq. mm, 1-core PVC wires including any wiring No. 40 4530
between switch board to switch board in appropriate size of
pvc conduit.

b Wiring for light point from switch board to first light point No. 91 2175
for phase with 1.5 sq.mm, common neutral of 2.5 sq. mm.
and common ECC of 2.5 sq. mm. + wires in specified /
appropriate size of exposed / concealed PVC conduit.
c Same as above item but wiring from point to point No. 86 1070
Wiring of 13A International Socket unit from DB to first
d outlet

2x2.5 Sq.mm + ECC 1x2.5 Sq.mm


No. 15 5600

Same as above item but wiring from outlet to outlet


e No. 8 1870
Wiring of 20A switch socket unit for Hand dryer from DB to
f first outlet. No. 8 4750

g 2x4 Sq.mm Cu/PVC + ECC 1x4 Sq.mm Cu/PVC No 4 4750

Supply, installation, testing and commissioning of following


B size of PVC/PVC cables for Main / Sub Main Distribution
Panels in already installed PVC conduit including all
accessories, complete in all respect as shown on drawing.
a From Wapda to MDB (or as per Site /instruction)
4C, 150 Sq. mm. PVC/PVC + ECC 1C, 95 Sq. mm. Rm. 100 14100

b From MDB to AC
4C, 120 Sq. mm. PVC/PVC + ECC 1C, 95 Sq. mm. Rm. 28 12500

c From MDB to DB-


4C, 16 Sq. mm. PVC/PVC + ECC 1C, 10 Sq. mm. Rm. 100 2200
Note : Contractor is advised to confirm the cable size,
running lengths and termination as per site conditions
before commencement of work.

C CABLE CONTAINMENT

Supply and installation of following size of PVC conduit


including all accessories such as junction box, bend, socket
etc. Complete in all respect.

a Rm. 3000 85
25mm dia PVC Conduit.
b 25mm dia PVC Conduit. For PTCL and internet cables Rm. 1500 85

D SWITCHES & SOCKETS

Supply and installation of Distribution boards made with 16


SWG sheet steel housing with approved color and having
specified circuit breakers as shown on drawing.
10A, 220V Four Switch socket Unit
a No. 135 875

13A, 3-Pin Flat Duplex Switch Socket Unit


b No. 45 1780

13A, International Switch Socket unit


c No. 200 1780

d 20A, Socket for Hand Dryer No. 5 1866

e 15A, 3 pin+Earth Round Switch Socket No. 105 1780

f NO. 87 533
13A, two gang switch socket units
Note : Contractor is advised to confirm the Switch UNITS,
Breakers, Sockets etc with their Nu. and termination as per
site conditions before commencement of work.

E LIGHTING FIXTURES AND POLES


Supply , installation , testing and commissioning of the
following lighting fixture LED Lights complete as specified or
as directed by the Engineer.

a LED Down Light 12watt No. 180 2400

b No. 40 1866
Ceiling mounted LED ligght fixture 1x10 watt color white
c Wall Bracket Mirror LED Light for Bath Room with 1x5W No. 10 1200
white color

d No. 120 4250


(2x2) False Ceiling Fan as approved by the Engineer.
e 12" dia Exhaust Fan Plastic Body with Louver Shutter No. 20 2400

f LED Pannel Light 2'X2' false ceiling type No. 224 12000

Note : Contractor is advised to confirm the Nu. Of all above


as per site condition or as directed by engineer before
commencement of work.

F DISTRIBUTION BOARDS

Supply and installation of Distribution boards made with 16


SWG sheet steel housing with approved color and having
specified circuit breakers as shown on drawing.
a MDB No 1 35000
b DB-AC No 6 33000
c DB-LP No 6 33000
G BREAKERS
a 200A, 3 pole MCCB (terrasaki) No 1 19600
b 100A, 3 pole MCCB (terrasaki) No 6 6100
c 32A, 3 pole MCCB (terrasaki) No 150 5000
d 16A, 3 pole MCCB (terrasaki) No 108 5000

Allow for any other Item required for completion of system


not covered in BOQ or specifications/ drawings in
accordance with the same standards and brands shown and
H approved by consultant/Engineer.All such Items shall be Job 2
covered in this Item but complete description , item rates,
qty required and brand shall be mentioned seperately and to
be attached with the BOQ.

I Installtion/ provision/ fixactionof wapda meter along with job 1 250000


connection

Supply and installation of AC units subject to aproval from


J client/owner, Complete with all respects as per
specifications/directed by Engineer

a 02 tons AC units
NOS 26 106000
b 01 tons AC units NOS 6 75500

c 1.5 tons AC units NOS 2 62000


TOTAL
ot campus

AMOUNT

181200

197925

92020

84000

14960

38000

19000

1410000

350000

220000
0

255000

127500

118125

80100

356000

9330

186900

46371

432000

74640
12000

510000

48000

2688000

35000
198000
198000
0
19600
36600
750000
540000

250000

2756000
453000
124000
12911271
SUKKUR IBA University Kandhkot campus
RENOVATION WORK
BILL OF QUANTITIES - Electrical work
S.N DESCRIPTION Qty UNIT
C PLUMBING WORK
1
PLUMBING FIXTURES, AND FITTINGS
Water closets Asian style withflush tank system fittings by Porta , or
1.1 approved equal 14 Nos

Water closets European style with close coupled cistern, fittings by Porta ,
acrylic seat cover of Grohe or approved equal
1.2 4 NO.s

C.P Tee valves, for cistern water inlet CP connectors with nuts and fittings, Groheor
a approved equal. 18 Nos

Muslim Shower with flexible hose, valve nozzle angle valve spont, Grohe or
b approved equal 18 Sets

2 Wash basins, single centre hole, suitable for counter top fittings for 15 Nos
below,Ghrohe or approved equal
CP Tee valves for wash basins, CP connections with nutes, fittings and
a complete with all accessories, Groheor or approved equal. 50 Nos

CP bottle trap 1-1/4" with pipe for wash basin waste connection and water
b strainer Groheor or approved equal. 18 Nos

CP Toilet paper roll holder Asia or approved equal complete with accessories.
c 18 Nos

Soap bottles, decorative type complete with accessories.


d 18 Nos

Gate valves, ball valves, check valves, strainers etc. Hattersley or approved
equal including all accessories and material as specified complete as per
3 drawings and specifications.

3.1 Gate Valve

a 1/2" diameter 10 Nos


b 3/4" diameter 18 Nos
c 1" diameter 18 Nos
d 1-1/4" diameter 10 Nos
e 1-1/2" diameter 5 Nos
f 2" diameter 10 No.s
3.2 Ball valve
a 1/2" diameter 10 No.s
b 3/4" diameter 18 No.s
3.3 Check valve
a 2" diameter 10 No.s
b 5" diameter
3.4 Strainer
a 2" diameter 15 No.s
4 WATER DISTRIBUTION SYSTEM
PPR PN 20 piping for cold water system, with fittings, specialties, including all
cutting, fitting, fixing and cleaning, wall and slab sleeves, CP clamps, hangers
and supports, making connection with fixtures, valves and specialties,
chiseling, making wall an floor openings and making good, pressure testing at
a pressure of 250 psig, painting of exposed piping in occupied areas with
primer and coats of approved paint in approved color complete in all respect.

a 1/2" diameter 100 Rft


b 3/4" diameter 510 Rft
c 1" diameter 360 Rft
d 1-1/2" diameter 270 Rft
e 2" diameter 970 Rft
SOIL, WASTE AND VENT SYSTEM
5 UPVC Class D piping including all fittings, sockets, hangers and specials for
a soil
2" diaand waste stacks and horizontal runs buried in ground or above false 100 Rft
ceiling, in shafts exposed or concealed in floors and walls and connecting to
b 3'' dia 270 Rft
manholes, including cutting, fitting, chiseling, making good, fixing and cleaning,
c wall
4" diaand slab openings complete in all respect. 340 Rft
d 6" dia 675 Rft
e 8" dia 115 RFT
UPVC Class D piping including all fittings, sockets, hangers and specials
for vent stacks and horizontal runs buried in ground or above false
ceiling, in shafts exposed or concealed in floors and walls and
6 connecting to manholes, including cutting, fitting, chiseling, making
good, fixing and cleaning, wall and slab openings complete in all respect.

a 1 1/2" dia 100 Rft


b 2" dia 135 Rft
c 3" dia 1350 Rft
7 Floor drains complete in all respect.
7.1 3" dia 10 No.s
Clean outs, polished bronze top with bronze grating and trap including jointing
7.2 and testing complete in all respect.

a 3" dia 40 Nos


b 4" dia 20 No.s
c Gully trap complete with accessories. 15 No.s
d Brick Masonary Manholes(3.5'x3.5'x6') complete in all respect 30 No.s
8 RAIN DRAIN SYSTEM
UPVC class D piping as per specifications and drawings for rain water,
embedded in walls and floors and clamped to wall or suspended from
slab etc. cutting of pipe, including clamps hangers collars supports and
specials such as Tee Y-Tee etc. making requisite number of holes in
walls and floors where necessary and making good the same as
necessary to the structure, painting pipes and fittings as specified and
testing the pipe line complete as per drawings and specifications

a 4" dia 600 Rft


b Roof drain complete with all respect. 4" dia 40 No.s
9 Related Work
a Providing and fixing with installaion of Motor including its Bore and all 2 JOb
accessories
Electric Wiringcomplete in allEquipment
for Plumbing respect with their electric
Completed fitting work
in all Respect etc as
as per
b 2 Job
per direction
Engineer of Engineer(also Motor control center with breaker all
c Testing and Comisionning of all Equipment with 3 months Test Run.
accessories) 2 Job
Note : Contractor is advised to confirm the length of all pipes , fitting and
confim the nu. Of equipment as per site condition /Engineer before
commencement of work.

TOTAL
dhkot campus
RK

RATE AMOUNT

10000 140000

15000 60000

2500 45000

6000 108000

20000 300000

1800 90000

1600 28800

400 7200

600 10800

0
1750 17500
1729 31122
2185 39330
3240 32400
5100 25500
7200 72000
0
1750 17500
1729 31122
0
600 6000
0
0
2000 30000
0

56 5600
88 44880
142 51120
272 73440
539 522830
0
0
135 13500
200 54000
290 98600
418 282150
650 74750

90 9000
135 18225
200 270000
0
1500 15000

800 32000
1200 24000
2000 30000
35000 1050000
0
0

320 192000
500 20000
0
20000 40000
10000 20000
5000 10000

4043369
SUKKUR IBA University Kandhkot campus
RENOVATION WORK
AT DO OFFICE KANDHKOT

MEASUREMENT SHEET
S. NO DESCRIPTION DO building amount

A CIVIL WORK 16827615.312677

B ELECTRICAL WORK 12911271

C PLUMBING WORK 4043369

gross amount RS 33782255.312677

in Millon 33.782255312677
University Kandhkot campus
NOVATION WORK
DO OFFICE KANDHKOT

UREMENT SHEET
pervious building difference
amount
25758296 -8930680.687323

10780435 2130836

1602828 2440541

38141559 -4359303.687323

38.141559 -4.35930368732301
SUKKUR IBA University Kandhkot campus
RENOVATION WORK
BILL OF QUANTITIES - Civil WORKS (Railcop Rates)
S.N DESCRIPTION UNIT Qty RATE AMOUNT Remarks
1.0 DISMANTLING

Dismantling/Chizzling and removal of Wall Plaster and shifting of the same lead upto
1.1 1.5km or as directed by engineer
SFT 32096.655 5 160483.275

Dismantling and removal of Wall/Partition Wall and shifting of the same lead upto
1.2 1.5km or as directed by engineer SFT 1866.0328 10 18660.328

Dismantling and removal of RCC Roof With Cutter/Blade or pointing material or as all the red mark
directed by engineer and shifting of the same lead upto 1.5km or as directed by rates are not in
1.3 engineer (All wooden, rebar or any other wastage/scrap shall be in entire custody of CFT 378 40 15120 railcops
contractor untill/unless advised by an engineer) estimate

Dismantling and removal of CC Floor as directed by engineer By


1.4 pointing/Cutting and shifting of the same lead upto 1.5km or as directed by SFT 595 26 15470
engineer.

Dismantling / removal of Roof Treated Material as directed by engineer By


1.5 pointing/Cutting and shifting of the same lead upto 1.5km or as directed by engineer. sft 9637.74 26 250581.24
ALL yelow
Marked are not
included in
pervious work
1.6
Dismantling and removal of tiles as directed by engineer By pointing/Cutting sft 415.91 5 2079.55
and shifting of the same lead upto 1.5km or as directed by engineer.

2.0 PLASTERING (Lucky, Falcon, DG Cement)


Providing and applying 1:4 cement plaster with thickness in two layers (12mm+ 13mm)
on interior/extrior surfaces using O.P. Cement/SR, as directed by Engineer at any height
and level including the cost of supply & fixing 8" wide expanded metal lath at the
junction of structural member and block wall, making chamfered edges as desired,
rounding of corners at junctions and making drip courses stops, groves, corner and stop SFT 40014.0488 50 2000702.44
beads wherever required, including scaffolding, preparation, treatment,curing, etc.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Engineer. O. including use of water proofing agent
tamseel CWP and Tamseel 20 or equivalent as per instruction of engineer

3.0 PLAIN CEMENT CONCRETE 0

Providing, laying, compacting, finishing & curing etc. straight designed mix cement
concrete 6" x 12" cylindrical crushing strength 3000 psi , using S.R or OPC Cement
including form work, leveling, compacting and curing, placing of all pipes, sleeves,
conduits and fittings, with necessary arrangements where required and other CFT 3409.7971 350 1193428.985
embedded items before concreting, supply of embedded item by the respective
contractor. Complete all as per drawings, specifications and as directed by the
Engineer.

3.1 Plain Cement concrete (Lean) 0

Providing, laying, compacting, finishing & curing etc. straight designed mix cement
concrete 6" x 12" cylindrical crushing strength 3000 psi , using S.R or OPC Cement
including form work, leveling, compacting and curing, placing of all pipes, sleeves,
conduits and fittings, with necessary arrangements where required and other cFT 709.103113 300 212730.9339
embedded items before concreting, supply of embedded item by the respective
contractor. Complete all as per drawings, specifications and as directed by the
Engineer.
4.0 RCC WORK

Providing and laying, straight or curved cast-in place designed mix reinforced
structural cement concrete 6"x 12" cylindrical crushing strength 3000 psi using
O.P.Cement and new Ply marine sheet including vibrating through electro
mechanical vibrator, leveling, compacting, curing, Shuttering, placing of all
pipes, sleeves, conduits and fittings, with necessary arrangements where
required and other embedded items before concreting, supply of embedded
item by the respective contractor.(excluding cost of steel reinforcement).
complete all as per drawings, specifications and as directed by the
Architect/Engineer.

4.2 columns CFT 14.628 350 5119.8


4.3 plinth beams for lavatory blocks CFT 422.1297 350 147745.395
4.4 lintel and roof beams CFT 314.09 350 109931.5
4.5 slab CFT 485.6375 350 169973.125
4.6 plinth beams and striup columns for partion walls CFT 88.2375 350 30883.125
5.0 STEEL REINFORCEMENT

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling
and testing) in position ribbed deformed bars steel conforming to ASTM A615
having minimum yield strength of 60,000 psi, including, wastage, unspecified
laps, steel chairs, rolling marging, binding wire, etc., complete in all respect as Tons 6.4 130000 832000
per drawings, specifications and to all approval of the Engineer–in–charge.
complete upto any floor and any height. (unspecified Overlaps pin and chairs etc
not to be paid).

6.0 BRICK MASONRY WORK


Providing and laying first class brick from Rahimyarkhan(GOMAL Brick) masonry
laid in1:4 cement sand mortar, in any shape, length or height, laid at specified
levels, masonry to be reinforced horizontally ties to concrete columns with steel
rods left projecting, (mild steel bar reinforcement measured& paid separately)
including cost of scaffolding,racking out joints cutting etc. complete all as per
drawings, specifications and as directed by the Engineer.

6.1 4-1/2" thick SFT 745 96.5 71892.5


6.2 9"thick SFT 2735.6 165 451374
6.3 13" thick SFT 706.9822 250 176745.55
6.4 18" THICK SFT 253.1522 325 82274.465
7.0 NATIONAL TERA COTA TILE 0

Providing & laying porcelain tile from Master/National or as approved by


engineer with all base 3/4", beds mortar and necessary allied work, complete in
all respect size 600mm x 600mm

7.1 at fornt potion of the building SFT 1731.941 355 614839.055


8.0 PORCELAIN CERAMIC TILES

Providing & Fixing of full body Imported Ceramic tiles600x600, including 1/2"
thick base plaster in 1:4 cement sand ratio, washing, cleaning, curing and
grouting etc. complete in all respect using approved grouting etc. complete in all SFT 1786.3225 320 571623.2
respect using approved bonding agent complete as per drawing and
specifications and /or directed by the Engineer Incharge. (Basic tile rate
Rs.2000.00/Sm.)

9.0 PORCELAIN CERAMIC TILE SKIRTING

Providing and fixing Porcelain ceramic tile 4" high skirting of approved quality
and shade, laid in approved patterns,set in cement sand 1/2" thick mortar (1:4)
and filling the joints with neat cement slurry, using matching color / pigment,
at any height or any floor, curing, final grinding and chemical polish, cleaning RFT 2316.69 160 370670.4
etc. complete in all respects and conforming to the requirement of drawings,
specifications and to the entire satisfaction of the Architect. (Basic tile rate
Rs.2000.00/Sm.)

10.0 GYPSUM TILES FALSE CEILING 0

Providing and installing 600 x 600 x 12mm thick vinyl coated gypsum ceiling tile,
elephant brand or DFB or equivalent including G.I. suspension system,
attachment devices,hanger edge molding, trim clip and trimming, including SFT 11144.0536 106 1181269.6816
making provision for light fixture, A/C diffusers, smoke detectors etc as per
drawing. Complete in all respect and conforming to the requirements of
drawings, specification and to the entire satisfaction of the Architect/ Engineer
11.0 WASHROOMS wall tiles 0

Providing and fixing full body Porcelain ceramic tile3/8" thick (600mmx300mm )
including dado of approved quality and shade (by benitos or its equivalent), laid
in approved patterns, set in cement sand mortar (1:4) and filling the joints with
stile bond or its equal, using matching color / pigment, at any height or any
floor,over including 1/2" thick 1:5 cement sand bedding of groove key to sub SFT 1562.68 195 304722.6
structure, supply& fixing imported plastic spacer between all junction of tiles,
leveling as per slope, curing, cleaning etc. complete in all respects and
conforming to the requirement of drawings, specifications and to the entire
satisfaction of the Architect.

12.0 STEPS
Providing and laying Marble Steps,also Making Emry filled Grooves with SFT 266.06 260 69175.6
Carborandom Chips complete in all respect as per instruction of Engineer

13 HAND RAIL 0

2'' Dia M.S Pipe Powder Coated Railing for Main Stairs, as per Drawing approved
By engineer Complete In all Respect(Note: contractor is advised to first measure RFT 100 1700 170000
the actual length of Hand Rail as per Site)

14.0 INTERNAL PAINT (on Ceiling,)

Providing and painting 3 coats of matt enamel of ICI, Kansai or its equivalent,
approved quality in approved shade, including a coat of primer with preparation
of surfaces, scrabing, filling, rubbing, clearing and smooth finishing etc., SFT 870.4125 34 29594.025
including scaffolding. Complete in all respects and conforming to the
requirements of drawings, specifications and to the entire satisfaction of the
Architect.
15.0 INTERNAL PAINT (on walls, beams, columns , etc.) 0

Providing and applying three coats of matt enamel and shade including
scrabing, cleaning, preparation of surface applying a coat of primer preparation SFT 36577.7128 34 1243642.2352
of base etc. Complete in all respect and conforming to the requirements of
drawings, specification and to the entire satisfaction of the Architect

15.1 GRILL windows and doors (ICI/BURGER Oil Paint) SFT 36.21 34 1231.14

16.0 DOORS/ FRAMES


Wooden Doors

Providing and Fixing 2'' thick first class Solid Core commercial Ply Door i/c GI
Door FRAME(chowkhat) 16 SWG Painted or polished approved quality of
Oxidized hinges, Brass Screw, Tower Bolts, Imported Locks top of the line Quick
Set hydraulic Closer (Brand new Star Japanese/ Or approved Quality) Door
Stopper and other Hardware of Brass i/c Iron hold fasts and three Coats of
polishing/oil paint complete in all respect as per drawing/Specification or
Directed By Engineer.

a D -1 doors(4.42 x6.75) SFT 179.01 700 125307


b D-2 doors(4 x6.75) SFT 594 700 415800
c D-3 doors(3x6.75) SFT 324 700 226800

Providing and Fixing 2'' thick first class Solid Core commercial Ply Door i/c GI
Door FRAME(chowkhat) 16 SWG Painted or polished approved quality of
d
Oxidized hinges, Brass Screw, Tower Bolts, Imported Locks Or approved Quality
and other Hardware of Brass i/c Iron hold fasts and three Coats of polishing/oil
paint complete in all respect as per drawing/Specification or Directed By
Engineer.
D-4 doors washrooms( 2.5 x6.75) SFT 253.125 700 177187.5
17.0 ALUMINIUM OPENABLE GLASS WINDOWS

Providing, and fixing of aluminum Glass Windows as per Drawing/approval


anodized PAK aluminum alloy extruded Deluxee section, with netted Shutter dull
natural finish, Deluxee but not less than 2mm thick section with 6mm Glazing or
its equivalent make as indicated on the drawings with frame of grade as specified
above using stainless steel screw, including (6mm) with clear glass imported SFT 1040 946 983840
( from SaudiArabia ) including ,heavy duty aluminum handles, hinges, fly Proofing
Mesh, gaskets, silicon filling, also Iron window Grill all around completeing
specification and to the entire satisfaction of the Engineer.(Including Dismantlin of
Existing)

18.0 PLINTH PROTECTION 0

Comprising of 6'' thick Hardcore 1:4:8 and 3'' thick 1:2:4 CC topping divide into
Panels With Marble Strips and 9'' thick Brick masonary Wall complete as per SFT 1104.82 357 394420.74
Site/ Drawing/ Directed By Engineer

19.0 OH WATER TANK (master fabric water tank) 0

supply install and fixation of OH water Tank as per Drawing /or as Directed By job 2 400000 800000
Engineer with all respects (Appro. 5000gallons)

20` CONVENTIONAL ROOFING OR TREATMENT 0


Providing and laying Water Proofing Membrane Sheet 4mm Thick i/c cost of
preparation and 4" over lapping (Hygrip) & flushing along with parapet wall, P/F
of glass strip i/c cost of 3''avergae thick PCC 1:2:4 (top), Roof Screeding in SFT 13767.7759 155 2134005.2645
panels having proper drain Slope. as per Drawing/Specification/approved by
Engineer.

21 CANOPY/guard cabin wooden 6×6 JOB 2 30000 60000

MAIN Gate repair work include providing, fixing, color OR Complete With all word
22 SFT 208 200 41600 "providing" is
respects
not was their
inpervious BOQ
23 WOODEN PARTIONS SFT 330 500 165000

24 Supply and installation of IBA sign/logo including paint or reflecter 2 No. of 6 X 4 job 2 10000 20000

25 supply install and fixation of angle framed shed with MS sheet(3mm thick) complete sft 100 300 30000
with all rspects 1.5" x1.5" - 6mm

SHEAR CRACKS' TREATMENT with SBR 1:1:3 ratio using 10 mm pins/ rebar at 9"c/c and
mimum length of 1 feet icluding cost of supplying, preparation/ V shape 40 mm deep
26 grooving with grinder & curing, .complete with all respect (Both sides of wall at any RFT 100 95 9500
height)

27 Excavation
Excavation for foundation in type of soil indluding dewatering and shifting of excavated
earth lead upto 1.5 km,as per specification and directed by engineer cft 5087.4277 12 61049.1324

28 BACK FILLING 0

With imported earth (sweat sand) cft 29619.097337 21 622001.044077

29 SOLING cft 119.00805 60 7140.483

30 Grating mesh over surface drain RFT 100 500 50000

TOTAL OF CIVIL WORKS 16827615.313


PUBLIC SCHOOL HYDERABAD (MANAGED
CONSTRUCTION WORK OF 2nd FLOOR @ AISHA HOUSE-GIRLS HOSTE
BILL OF QUANTITIES - Civil WORKS
S.N DESCRIPTION
1 R.C.C Work

Providing and laying, straight or curved cast-in place designed mix reinforced structural
cement concrete 6"x 12" cylindrical crushing strength 3000 psi using O.P.Cement and
new Ply marine sheet including vibrating through electro mechanical vibrator, leveling,
compacting, curing, Shuttering, placing of all pipes, sleeves, conduits and fittings, with
necessary arrangements where required and other embedded items before concreting,
supply of embedded item by the respective contractor.(excluding cost of steel
reinforcement). complete all as per drawings, specifications and as directed by the
Architect/Engineer.
Slab ( 6" thick )
Beams ( 9" x 24" )
2 STEEL REINFORCEMENT

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling and
testing) in position ribbed deformed bars steel conforming to ASTM A615 having
minimum yield strength of 60,000 psi, including, wastage, unspecified laps, steel chairs,
rolling marging, binding wire, etc., complete in all respect as per drawings, specifications
and to all approval of the Engineer–in–charge. complete upto any floor and any height.
(unspecified Overlaps pin and chairs etc not to be paid).
#6 Bar
#5 Bar
#3 Bar
#4 Bar
3 BRICK MASONRY WORK

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling and
testing) in position ribbed deformed bars steel conforming to ASTM A615 having
minimum yield strength of 60,000 psi, including, wastage, unspecified laps, steel chairs,
rolling marging, binding wire, etc., complete in all respect as per drawings, specifications
and to all approval of the Engineer–in–charge. complete upto any floor and any height.
(unspecified Overlaps pin and chairs etc not to be paid).
6" THICK
4.5" THICK
6" THICK - Parapet Wall
4 PLASTERING (Lucky, Falcon, DG Cement)
Providing and applying 1:4 cement plaster with thickness in two layers (12mm+ 13mm)
on interior/extrior surfaces using O.P. Cement/SR, as directed by Engineer at any height
and level including the cost of supply & fixing 8" wide expanded metal lath at the
junction of structural member and block wall, making chamfered edges as desired,
rounding of corners at junctions and making drip courses stops, groves, corner and stop
beads wherever required, including scaffolding, preparation, treatment,curing, etc.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Engineer. O. including use of water proofing agent
tamseel CWP and Tamseel 20 or equivalent as per instruction of engineer
5 INTERNAL PAINTS (on ceiling , walls , beams , columns)
Providing and painting 3 coats of matt enamel of ICI, Kansai or its equivalent, approved
quality in approved shade, including a coat of primer with preparation of surfaces,
scrabing, filling, rubbing, clearing and smooth finishing etc., including scaffolding.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Architect.

6 PORCELAIN CERAMIC TILE


Providing & Fixing of full body Imported Ceramic tiles600x600, including 1/2" thick base
plaster in 1:4 cement sand ratio, washing, cleaning, curing and grouting etc. complete in
all respect using approved grouting etc. complete in all respect using approved bonding
agent complete as per drawing and specifications and /or directed by the Engineer
Incharge.

7 PORCELAIN CERAMIC TILE SKIRTING


Providing and fixing Porcelain ceramic tile 4" high skirting of approved quality and shade,
laid in approved patterns,set in cement sand 1/2" thick mortar (1:4) and filling the joints
with neat cement slurry, using matching color / pigment, at any height or any floor,
curing, final grinding and chemical polish, cleaning etc. complete in all respects and
conforming to the requirement of drawings, specifications and to the entire satisfaction
of the Architect.

8 WASHROOMS WALL TILES


Providing and fixing full body Porcelain ceramic tile3/8" thick (600mmx300mm )
including dado of approved quality and shade (by benitos or its equivalent), laid in
approved patterns, set in cement sand mortar (1:4) and filling the joints with stile bond
or its equal, using matching color / pigment, at any height or any floor,over including
1/2" thick 1:5 cement sand bedding of groove key to sub structure, supply& fixing
imported plastic spacer between all junction of tiles, leveling as per slope, curing,
cleaning etc. complete in all respects and conforming to the requirement of drawings,
specifications and to the entire satisfaction of the Architect.

9 STEPS
Providing and laying Marble Steps,also Making Emry filled Grooves with Carborandom
Chips complete in all respect as per instruction of Engineer
10 DOORS/ FRAMES
Providing and Fixing 2'' thick first class Solid Core commercial Ply Door i/c GI Door
FRAME(chowkhat) 16 SWG Painted or polished approved quality of Oxidized hinges,
Brass Screw, Tower Bolts, Imported Locks top of the line Quick Set hydraulic Closer
(Brand new Star Japanese/ Or approved Quality) Door Stopper and other Hardware of
Brass i/c Iron hold fasts and three Coats of polishing/oil paint complete in all respect as
per drawing/Specification or Directed By Engineer.

D1
D1 (Chokhat)
RABAD (MANAGED BY SIBAU)
SHA HOUSE-GIRLS HOSTEL - COVERED AREA 17000 SFT
NTITIES - Civil WORKS
UNIT Qty RATE AMOUNT Remarks

Cft 9000
Cft 3000

Kg 4000
Kg 10000
Kg 3800
Kg 30000

SFT 5695
SFT 10072
SFT 2745
SFT 47000

SFT 47000

SFT 17000

RFT 3710

SFT 1600

SFT 192
SFT 540
RFT 385
PUBLIC SCHOOL HYDERABAD (MANAGED
CONSTRUCTION WORK OF 2nd FLOOR @ AISHA HOUSE-GIRLS HOSTE
BILL OF QUANTITIES - Civil WORKS
S.N DESCRIPTION

1 EXCAVATION

2 BACKFILLING

3 STONE SOLING

4 P.C.C ( LEAN 1:4:8 )

5 R.C.C Work

Providing and laying, straight or curved cast-in place designed mix reinforced structural
cement concrete 6"x 12" cylindrical crushing strength 3000 psi using O.P.Cement and
new Ply marine sheet including vibrating through electro mechanical vibrator, leveling,
compacting, curing, Shuttering, placing of all pipes, sleeves, conduits and fittings, with
necessary arrangements where required and other embedded items before concreting,
supply of embedded item by the respective contractor.(excluding cost of steel
reinforcement). complete all as per drawings, specifications and as directed by the
Architect/Engineer.
Slab ( thick )
Beams ( )
Column
Foundation
6 STEEL REINFORCEMENT

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling and
testing) in position ribbed deformed bars steel conforming to ASTM A615 having
minimum yield strength of 60,000 psi, including, wastage, unspecified laps, steel chairs,
rolling marging, binding wire, etc., complete in all respect as per drawings, specifications
and to all approval of the Engineer–in–charge. complete upto any floor and any height.
(unspecified Overlaps pin and chairs etc not to be paid).
# 3 Bar
# 4 Bar
# 5 Bar
7 BRICK MASONRY WORK

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling and
testing) in position ribbed deformed bars steel conforming to ASTM A615 having
minimum yield strength of 60,000 psi, including, wastage, unspecified laps, steel chairs,
rolling marging, binding wire, etc., complete in all respect as per drawings, specifications
and to all approval of the Engineer–in–charge. complete upto any floor and any height.
(unspecified Overlaps pin and chairs etc not to be paid).
THICK 6"

8 PLASTERING (Lucky, Falcon, DG Cement)

Providing and applying 1:4 cement plaster with thickness in two layers (12mm+ 13mm)
on interior/extrior surfaces using O.P. Cement/SR, as directed by Engineer at any height
and level including the cost of supply & fixing 8" wide expanded metal lath at the
junction of structural member and block wall, making chamfered edges as desired,
rounding of corners at junctions and making drip courses stops, groves, corner and stop
beads wherever required, including scaffolding, preparation, treatment,curing, etc.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Engineer. O. including use of water proofing agent
tamseel CWP and Tamseel 20 or equivalent as per instruction of engineer
9 INTERNAL PAINTS (on ceiling , walls , beams , columns)
Providing and painting 3 coats of matt enamel of ICI, Kansai or its equivalent, approved
quality in approved shade, including a coat of primer with preparation of surfaces,
scrabing, filling, rubbing, clearing and smooth finishing etc., including scaffolding.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Architect.

10 PORCELAIN CERAMIC TILE


Providing & Fixing of full body Imported Ceramic tiles600x600, including 1/2" thick base
plaster in 1:4 cement sand ratio, washing, cleaning, curing and grouting etc. complete in
all respect using approved grouting etc. complete in all respect using approved bonding
agent complete as per drawing and specifications and /or directed by the Engineer
Incharge.

11 PORCELAIN CERAMIC TILE SKIRTING


Providing and fixing Porcelain ceramic tile 4" high skirting of approved quality and shade,
laid in approved patterns,set in cement sand 1/2" thick mortar (1:4) and filling the joints
with neat cement slurry, using matching color / pigment, at any height or any floor,
curing, final grinding and chemical polish, cleaning etc. complete in all respects and
conforming to the requirement of drawings, specifications and to the entire satisfaction
of the Architect.

12 WASHROOMS WALL TILES


Providing and fixing full body Porcelain ceramic tile3/8" thick (600mmx300mm )
including dado of approved quality and shade (by benitos or its equivalent), laid in
approved patterns, set in cement sand mortar (1:4) and filling the joints with stile bond
or its equal, using matching color / pigment, at any height or any floor,over including
1/2" thick 1:5 cement sand bedding of groove key to sub structure, supply& fixing
imported plastic spacer between all junction of tiles, leveling as per slope, curing,
cleaning etc. complete in all respects and conforming to the requirement of drawings,
specifications and to the entire satisfaction of the Architect.

13 STEPS
Providing and laying Marble Steps,also Making Emry filled Grooves with Carborandom
Chips complete in all respect as per instruction of Engineer
14 DOORS/ FRAMES
Providing and Fixing 2'' thick first class Solid Core commercial Ply Door i/c GI Door
FRAME(chowkhat) 16 SWG Painted or polished approved quality of Oxidized hinges,
Brass Screw, Tower Bolts, Imported Locks top of the line Quick Set hydraulic Closer
(Brand new Star Japanese/ Or approved Quality) Door Stopper and other Hardware of
Brass i/c Iron hold fasts and three Coats of polishing/oil paint complete in all respect as
per drawing/Specification or Directed By Engineer.

D1
D1
RABAD (MANAGED BY SIBAU)
SHA HOUSE-GIRLS HOSTEL - COVERED AREA 17000 SFT
NTITIES - Civil WORKS
UNIT Qty RATE AMOUNT Remarks

CFT 4000

CFT 25000

CFT 400

CFT 400

Cft 1688
Cft 1150
Cft 1400
Cft 1152

Kg 6000
Kg 2500
Kg 11000

SFT 6600

SFT 28000

SFT 25000

SFT 4000

RFT 2500
SFT 850

SFT 120

SFT 230
Rft 60
PUBLIC SCHOOL HYDERABAD (MANAGED
CONSTRUCTION WORK OF 2nd FLOOR @ AISHA HOUSE-GIRLS HOSTE
BILL OF QUANTITIES - Civil WORKS
S.N DESCRIPTION

1 EXCAVATION

2 BACKFILLING

3 STONE SOLING

4 P.C.C ( LEAN 1:4:8 )

5 R.C.C Work

Providing and laying, straight or curved cast-in place designed mix reinforced structural
cement concrete 6"x 12" cylindrical crushing strength 3000 psi using O.P.Cement and
new Ply marine sheet including vibrating through electro mechanical vibrator, leveling,
compacting, curing, Shuttering, placing of all pipes, sleeves, conduits and fittings, with
necessary arrangements where required and other embedded items before concreting,
supply of embedded item by the respective contractor.(excluding cost of steel
reinforcement). complete all as per drawings, specifications and as directed by the
Architect/Engineer.
Slab ( thick )
Beams ( )
Column
Foundation
6 STEEL REINFORCEMENT

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling and
testing) in position ribbed deformed bars steel conforming to ASTM A615 having
minimum yield strength of 60,000 psi, including, wastage, unspecified laps, steel chairs,
rolling marging, binding wire, etc., complete in all respect as per drawings, specifications
and to all approval of the Engineer–in–charge. complete upto any floor and any height.
(unspecified Overlaps pin and chairs etc not to be paid).
# 2 Bar
# 3 Bar
# 4 Bar
7 BRICK MASONRY WORK

Supplying, cutting, bending, binding and fixing(Amreli Steel i/c cost of sampling and
testing) in position ribbed deformed bars steel conforming to ASTM A615 having
minimum yield strength of 60,000 psi, including, wastage, unspecified laps, steel chairs,
rolling marging, binding wire, etc., complete in all respect as per drawings, specifications
and to all approval of the Engineer–in–charge. complete upto any floor and any height.
(unspecified Overlaps pin and chairs etc not to be paid).
THICK 9"
THICK 6"
THICK 6" - Parapet Wall
8 PLASTERING (Lucky, Falcon, DG Cement)

Providing and applying 1:4 cement plaster with thickness in two layers (12mm+ 13mm)
on interior/extrior surfaces using O.P. Cement/SR, as directed by Engineer at any height
and level including the cost of supply & fixing 8" wide expanded metal lath at the
junction of structural member and block wall, making chamfered edges as desired,
rounding of corners at junctions and making drip courses stops, groves, corner and stop
beads wherever required, including scaffolding, preparation, treatment,curing, etc.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Engineer. O. including use of water proofing agent
tamseel CWP and Tamseel 20 or equivalent as per instruction of engineer
9 INTERNAL PAINTS (on ceiling , walls , beams , columns)
Providing and painting 3 coats of matt enamel of ICI, Kansai or its equivalent, approved
quality in approved shade, including a coat of primer with preparation of surfaces,
scrabing, filling, rubbing, clearing and smooth finishing etc., including scaffolding.
Complete in all respects and conforming to the requirements of drawings, specifications
and to the entire satisfaction of the Architect.

10 PORCELAIN CERAMIC TILE


Providing & Fixing of full body Imported Ceramic tiles600x600, including 1/2" thick base
plaster in 1:4 cement sand ratio, washing, cleaning, curing and grouting etc. complete in
all respect using approved grouting etc. complete in all respect using approved bonding
agent complete as per drawing and specifications and /or directed by the Engineer
Incharge.

11 PORCELAIN CERAMIC TILE SKIRTING


Providing and fixing Porcelain ceramic tile 4" high skirting of approved quality and shade,
laid in approved patterns,set in cement sand 1/2" thick mortar (1:4) and filling the joints
with neat cement slurry, using matching color / pigment, at any height or any floor,
curing, final grinding and chemical polish, cleaning etc. complete in all respects and
conforming to the requirement of drawings, specifications and to the entire satisfaction
of the Architect.

12 WASHROOMS WALL TILES


Providing and fixing full body Porcelain ceramic tile3/8" thick (600mmx300mm )
including dado of approved quality and shade (by benitos or its equivalent), laid in
approved patterns, set in cement sand mortar (1:4) and filling the joints with stile bond
or its equal, using matching color / pigment, at any height or any floor,over including
1/2" thick 1:5 cement sand bedding of groove key to sub structure, supply& fixing
imported plastic spacer between all junction of tiles, leveling as per slope, curing,
cleaning etc. complete in all respects and conforming to the requirement of drawings,
specifications and to the entire satisfaction of the Architect.

13 STEPS
Providing and laying Marble Steps,also Making Emry filled Grooves with Carborandom
Chips complete in all respect as per instruction of Engineer
14 DOORS/ FRAMES
Providing and Fixing 2'' thick first class Solid Core commercial Ply Door i/c GI Door
FRAME(chowkhat) 16 SWG Painted or polished approved quality of Oxidized hinges,
Brass Screw, Tower Bolts, Imported Locks top of the line Quick Set hydraulic Closer
(Brand new Star Japanese/ Or approved Quality) Door Stopper and other Hardware of
Brass i/c Iron hold fasts and three Coats of polishing/oil paint complete in all respect as
per drawing/Specification or Directed By Engineer.

D1
D2
D3
D4
RABAD (MANAGED BY SIBAU)
SHA HOUSE-GIRLS HOSTEL - COVERED AREA 17000 SFT
NTITIES - Civil WORKS
UNIT Qty RATE AMOUNT Remarks

CFT 3365

CFT 6990

CFT 169

CFT 340

Cft 1450
Cft 970
Cft 650
Cft 1000

Kg 1100
Kg 2500
Kg 4200

SFT 600
SFT 6500
SFT 600

SFT 22268

SFT 21000

SFT

RFT
SFT

SFT

SFT
SFT
SFT
SFT