18 inch Combo CALIBRATION REPORT

18 inch Combo CALIBRATION REPORT

Project # 057 5159

Page 1 of 19
18 inch Combo CALIBRATION REPORT

TABLE OF CONTENTS

CHAPTER 1. TOOL CALIBRATION PROCEDURE ....................................... 4


1.1. Purpose ........................................................................................ 4
1.2. Scope ........................................................................................... 4
1.3. Responsibility ............................................................................... 4
1.4. Definitions.................................................................................... 4
1.5. Materials and equipment .............................................................. 4
1.6. Procedure ..................................................................................... 5
1.7. Preparation .................................................................................. 5
1.8. After Test Activities ...................................................................... 5
1.9. Reporting Activity ........................................................................ 5
1.10. Personnel involved ....................................................................... 6
1.11. QA/QC .......................................................................................... 6
CHAPTER 2. 18 INCH CALIBRATION REPORT ......................................... 7
2.1. 18 inch Pipe Sketch ...................................................................... 7
2.2. Tool Data Sheet ............................................................................ 8
2.3. Tool Calibration Report ................................................................ 9
2.4. Telemetric Data .......................................................................... 10
2.5. PTT Results ................................................................................ 12
2.6. Calibration Test Results ............................................................. 16
CHAPTER 3. CALIBRATION CERTIFICATE ............................................. 18
CHAPTER 4. CONTACT US ..................................................................... 19

Page 2 of 19
18 inch Combo CALIBRATION REPORT

Prepared by | Pavel Ilyin 05.12.2017


Data Analyst

Reviewed by | Anton Suraev 05.12.2017


Data Analysis Manager

LIN SCAN Advanced Pipeline & Tank Service


Hamriyah Free Zone, Sharjah
P.O. Box 62159, Dubai,
United Arab Emirates
T: +971 6 5262442
F: +971 6 5262443

Page 3 of 19
18 inch Combo CALIBRATION REPORT

Chapter 1. TOOL CALIBRATION PROCEDURE

1.1. Purpose
To ensure that specified and declared tool accuracy and detection values are
met during the actual in-line pipeline inspection.

1.2. Scope
This procedure is applicable to working processes of QA/QC, Production, Data
Evaluation and Project Departments.

1.3. Responsibility
QA/QC, Production, Data Evaluation Department Managers are responsible
for implementation of this procedure.

1.4. Definitions

ILI tool: In-line Inspection tool/vehicle, intelligent geometry or


magnetic flux leakage pig.
MFL tool: Magnetic flux leakage (MFL) is a magnetic method of
nondestructive testing that is used to detect corrosion and
pitting in steel structures, most commonly pipelines and
storage tanks. MFL imparts an axial magnetic field and is
therefore limited in defect detection for narrow axial
features - cracks in seam welds, axial orientated slotting
and NAEC.
Caliper tool: A type of tool used to measure internal diameter of the
pipeline.
Test pipe: Metal pipe with artificial defects, used for testing and
calibration of the ILI tool
PTT: Pull Through Test – operation used for ILI tool testing and
calibration by pulling the tool through test pipe.

1.5. Materials and equipment


∙ Test pipe.
∙ PTT Test stand;
∙ Pulling Winch;
∙ Operator PC;

Page 4 of 19
18 inch Combo CALIBRATION REPORT

∙ Connection cables;
∙ Pulling rope;
∙ Hoisting facilities;
∙ Accessories;
∙ Metal processing tools;
∙ Measurement instruments including handheld UT scanner.

1.6. Procedure
Pull-Through Test is carried out by pulling the magnetic flux leakage or
geometry inspection vehicle through the test pipe by means of a hydraulic or
manual winch. The tool is moved at a constant velocity of 0.3-3.0 m/sec. On
the test pipe, artificial models of defect types of different sizes are applied.
Dimensions of the defects are accurately measured. The tool is switched to
operating mode during the test and after the test, the received data is
analyzed.
Geometry tool is calibrated on a stand-by means of a special calibration ruler
in a static condition for building calibration curves.

1.7. Preparation
Joint measurements of all the test pipe anomalies provided may be checked
by client representative with our QA/ QC personnel, with inspection tools and
instruments, prior to Pull through Test and to be recorded.

1.8. After Test Activities


After the Pull Through Test, the inspection tool is moved from the output tray
of the testing pipe with appropriate hoisting facilities.
The operator connects cables and checks the functionality of the systems and
availability of the recorded data. In case systems are inoperative or/and data
is not recorded tool is returned to Production Department for investigation.

Operator downloads the data to PC, records on a portable memory unit and
handed over to Evaluation department for analysis.

1.9. Reporting Activity


After completion of data evaluation, data analyst will issue Pull Through Test
report including:
- ILI tool configuration includes a number of primary and secondary sensors;

Page 5 of 19
18 inch Combo CALIBRATION REPORT

- ILI tool functionality test report.


This report includes all defects sizing including ID/OD discrimination, axial
and circumferential position. Defects in HAZ will be highlighted.
1.10. Personnel involved
Representatives from Production, QA/QC and Projects Departments and
Electronic Division are to be present during the Pull-Through Test.
Representatives of Production - and QA/QC Departments, as well as
Electronic Division, are to confirm on the pull through test report card
readiness of the inspection tool for Pull Through Test. Evaluation department
manager issues the Pull-Through Test report. A representative of Data
Evaluation and Projects Departments confirm that accuracy specifications of
the tool meet the requirements specified based on Pull Through Test.

1.11. QA/QC
QA/QC department representative controls the whole process and
documentation is checked and approved by the QA/QC Manager. Pull through
tests are obligatorily attended by QA/QC Production representative. Pull
Through Test & Calibration reports are prepared and maintained by the
Evaluation and Projects Department.

Page 6 of 19
18 inch Combo CALIBRATION REPORT

Chapter 2. 18-inch Calibration Report


2.1. 18 inch Pipe Sketch

Page 7 of 19
18 inch Combo CALIBRATION REPORT

2.2. Tool Data Sheet


18-inch ILI tool configuration

Page 8 of 19
18 inch Combo CALIBRATION REPORT

2.3. Tool Calibration Report

Pull Trough Test was conducted in a spool (test pipe) with artificial defects
according to the drawings attached in Chapter 2.

Magnetization level in test pipe with 9.5 mm wall thickness reached 20 kA/m.

According to the POF specification, this level of pipe wall magnetization guaranteed
good sensitivity and accuracy of the MFL ILI tool.

For the PTT run the defects will be analyzed against actual parameters.

MFL log presents PTT run data. The vertical axis on the log represents degree
position of the defects (0-360 degree corresponding to 12:00 o’clock clockwise
positions). The horizontal axis on the logs represents recorded distance aligned
with the starting of the PTT pipe - first spool.

Page 9 of 19
18 inch Combo CALIBRATION REPORT

2.4. Telemetric Data


Velocity Profile

Page 10 of 19
18 inch Combo CALIBRATION REPORT

Magnetization level Profile

Page 11 of 19
18 inch Combo CALIBRATION REPORT

2.5. PTT Results

Equipment: MFL 18-20-MF-D03


Test Pipe WT: 9.5 mm thickness

Sketch Dimension Tool Result Specification Actual Vs. Spec.


L, W, Depth, L, W, Depth, L80%, W80%,
No. Type D80% L W D Comments
mm mm % mm mm % mm mm
1 Ext PINH 6 6 60 5 7 29 - - - - - - adj. to HAZ
2 Ext PITT 10 10 45 6 9 37 15 15 15 Y Y Y adj. to HAZ
3 Ext PINH 6 6 30 5 7 12 - - - - - - adj. to HAZ
4 Ext PITT 10 10 15 - - - 15 15 15 - - - adj. to HAZ
5 Ext AXGR 40 20 45 42 26 42 10 15 15 Y Y Y
6 Ext AXGR 40 20 34 40 23 31 10 15 15 Y Y Y
7 Ext AXGR 40 20 22 38 22 20 10 15 15 Y Y Y
8 Ext AXGR 40 20 11 37 19 10 10 15 15 Y Y Y
9 Ext GENE 40 40 60 43 45 63 15 15 10 Y Y Y
10 Ext GENE 30 30 37 32 34 39 15 15 10 Y Y Y
11 Ext GENE 40 40 22 41 43 23 15 15 10 Y Y Y adj. to Support
12 Ext GENE 30 30 7 28 29 5 15 15 10 Y Y Y adj. to Support
13 Ext PITT 22 22 45 25 27 42 15 15 15 Y Y Y
14 Ext PITT 17 17 34 15 20 30 15 15 15 Y Y Y
15 Ext PITT 22 22 22 18 24 16 15 15 15 Y Y Y
16 Ext PITT 17 17 11 12 15 5 15 15 15 Y Y Y
17 Ext AXGR 30 10 52 32 14 39 10 15 15 Y Y Y
18 Ext AXSL 20 6 37 12 8 6 - - - - - -
19 Ext AXSL 20 6 22 13 9 7 - - - - - -
20 Ext AXGR 30 10 11 - - - 10 15 15 - - -
21 Ext CISL 3 254 15 6 258 24 10 15 15 Y Y Y
22 Ext CISL 3 254 30 8 260 39 10 15 15 Y Y Y
23 Ext CISL 3 254 45 10 265 54 10 15 15 Y Y Y
24 Ext AXSL 300 3 15 - - - - - - - - -
25.1 Ext PITT 22 22 15 15 15 15
18 38 20 n/a n/a n/a
25.2 Ext PITT 17 17 22 15 15 15
25.3 Ext GENE 30 30 19 28 33 15 15 15 10 Y Y Y
Page 12 of 19
18 inch Combo CALIBRATION REPORT

Sketch Dimension Tool Result Specification Actual Vs. Spec.


L, W, Depth, L, W, Depth, L80%, W80%,
No. Type D80% L W D Comments
mm mm % mm mm % mm mm
25.4 Ext PITT 17 17 26 12 15 20 15 15 15 Y Y Y
26.1 Ext GENE 30 30 30 25 35 25 15 15 10 Y Y Y
26.2 Ext GENE 40 40 11 38 43 13 15 15 10 Y Y Y
26.3 Ext PITT 20 20 22 16 23 17 15 15 15 Y Y Y
27.1 Ext PITT 20 20 37 22 26 35 15 15 15 Y Y Y
27.2 Ext GENE 30 30 19 24 33 15 15 15 10 Y Y Y
27.3 Ext PITT 17 17 30 14 18 19 15 15 15 Y Y Y
28.1 Ext PITT 20 20 45 22 25 38 15 15 15 Y Y Y
28.2 Ext GENE 40 40 19 35 38 14 15 15 10 Y Y Y
29 Ext CIGR 20 40 52 24 48 58 15 15 10 Y Y Y
30 Ext CIGR 20 60 37 24 69 42 15 15 10 Y Y Y
31 Ext CIGR 20 40 22 22 45 26 15 15 10 Y Y Y
32 Ext CIGR 20 60 7 19 65 11 15 15 10 Y Y Y
33 Int PITT 20 20 15 22 23 13 15 15 15 Y Y Y
34 Int PITT 20 20 30 22 25 28 15 15 15 Y Y Y
35 Int GENE 30 30 7 23 25 5 15 15 10 Y Y Y
36 Int GENE 40 40 15 26 44 13 15 15 10 Y Y Y
37 Int CIGR 20 1435 15 24 1439 19 15 15 10 Y Y Y
38 Int GENE 30 30 15 28 33 17 15 15 10 Y Y Y
39 Int PITT 12 12 30 7 13 23 15 15 15 Y Y Y

Page 13 of 19
18 inch Combo CALIBRATION REPORT

Defect map – Color View (highlited numbers were not detected)

1 5 9 13 17 25 29

33 35 38

2 6 10 14 18 26 30

37

21
22 27 31
3 7 11 15 19
23
34 36 39

24
4 12 20 28 32
8 16

Page 14 of 19
18 inch Combo CALIBRATION REPORT

Defect map – Line View (highlited numbers were not detected)

1 5 9 13 17 25 29

33 35 38

2 6 10 14 18 26 30

37

21
27 31
3 7 11 15 19 22
23
34 36 39

24
4 12 20 28 32
8 16

Page 15 of 19
18 inch Combo CALIBRATION REPORT

2.6. Calibration Test Results

The Calibration Test was conducted on a stand. The table represents the dependence of the signal value on the arms’
deviation.

L (mm) Sen1 Sen2 Sen3 Sen4 Sen5 Sen6 Sen7 Sen8 Sen9 Sen10 Sen11 Sen12 Sen13 Sen14 Sen15 Sen16
245 519 406 293 248 264 270 187 214 230 230 281 337 303 272 484 266
240 679 567 438 384 421 418 344 389 392 384 437 465 483 429 633 406
235 808 712 589 539 552 557 471 527 518 514 584 584 621 585 770 538
230 949 845 714 663 683 682 594 662 646 648 716 729 776 696 892 660
225 1072 971 838 780 821 802 724 787 768 766 828 856 919 855 1006 780
220 1185 1085 943 898 941 929 847 914 873 874 940 960 1030 965 1136 891
215 1301 1203 1052 987 1055 1031 963 1012 972 985 1051 1094 1153 1085 1261 1002
210 1414 1315 1159 1107 1175 1136 1065 1126 1082 1085 1139 1119 1271 1195 1326 1102
205 1520 1419 1257 1204 1267 1231 1165 1226 1191 1186 1246 1298 1382 1279 1430 1196
200 1622 1508 1359 1299 1370 1329 1257 1349 1283 1295 1337 1361 1488 1384 1541 1299
195 1727 1621 1456 1394 1490 1424 1362 1438 1373 1383 1428 1446 1594 1481 1621 1394
190 1824 1718 1547 1489 1587 1521 1454 1537 1480 1486 1520 1581 1696 1592 1718 1490
185 1920 1813 1640 1568 1676 1610 1560 1629 1562 1572 1610 1597 1798 1701 1804 1580
180 2011 1914 1727 1669 1777 1701 1658 1723 1650 1662 1698 1746 1894 1757 1895 1673
175 2107 2003 1821 1756 1864 1782 1734 1817 1744 1744 1784 1838 1990 1851 1981 1755
170 2196 2093 1912 1841 1945 1872 1831 1901 1824 1839 1870 1873 2084 1960 2064 1840
165 2287 2186 2005 1929 2034 1952 1923 1999 1911 1930 1953 1986 2177 2030 2169 1922
160 2372 2265 2082 2010 2122 2042 1998 2076 1986 2012 2038 2078 2268 2120 2252 2008

Page 16 of 19
18 inch Combo CALIBRATION REPORT

Figure 1 shows dependence of measured signal of each sensor (vertical axis) on arm’s deviation (horizontal axis).

Figure 1. Calibration curves

Page 17 of 19
18 inch Combo CALIBRATION REPORT

Chapter 3. Calibration Certificate

Equipment : MFL 18-20-MF-D03 & CLP+IMU 16-00-CL-B02

Pipe Specifications : API 5L X65, 6.0 m length, 9.5 mm thickness

Number of runs :3

PTT Runs specifications (9.5 mm test pipeline):

PTT Run # Run #1 Run #2 Run #3


Min defect visible Yes Yes Yes
Max defect visible Yes Yes Yes
Average achieved ~90 ~90 ~90
Saturation level achieved No No No
Overall data quality Good Good Good
Senor loss None None None

Tool specifications:

Storage capacity 16 Gigabytes


Speed 0.3 – 3.0 m/s
Distance 330 km
Pitch measurement in the longitudinal direction 1 mm
Pitch measurement in the circumferential direction 4.5 mm
Wall thickness 4.0 – 20.0 mm
Outside pipeline diameter 18 inch

The 18-inch Combo Tool has been tested and accordingly calibrated.

The 18-inch Combo Tool is approved for pipeline inspection.

The MFL tool sensitivity should be Offset=2 & Gain=2, and optimum sampling rate should be
2 ms.

Authorized Signature 1 Authorized Signature 2

Name: Pavel Ilyin Name: Anton Suraev

Date: 05.12.2017 Date: 05.12.2017

Page 18 of 19
18 inch Combo CALIBRATION REPORT

Chapter 4. Contact Us

Tel : 00971 6 5262442

Fax : 00971 6 5262443

Address : LIN SCAN Advanced Pipeline & Tank Services


Hamriyah Free Zone (Plot No. 1 H-24)
Sharjah, United Arab Emirates

Mailing Address : P.O. Box: 62159


Dubai, UAE

E-mail : info@linscaninspection.com

Website : www.linscaninspection.com

Page 19 of 19

You might also like