Professional Documents
Culture Documents
Sieve and Hydrometer Results of Dry Bin Crosby Till: Particle Size (MM)
Sieve and Hydrometer Results of Dry Bin Crosby Till: Particle Size (MM)
Sieve and Hydrometer Results of Dry Bin Crosby Till: Particle Size (MM)
100
90
Percent Finer
80
Sieve Analysis
Hydrometer Results
70
60
50
40
30
20
10
0
10.00 1.00 0.10 0.01 0.00
Particle Size (mm)
Name AP Sample Crosby Till Dry Bin
Date 6/4/2003 Test Hydrometer
Hydrometer Readings
Elapsed Time (min), T Reading Temp C R % Finer dia (mm) K L
2 39 23 35 32 0.0303 0.01317 10.6
5 32 22 28 25 0.0204 0.01332 11.7
15 22 21 18 16 0.0127 0.01348 13.3
30 18 21 14 13 0.0092 0.01348 14.0
60 15 22 11 10 0.0065 0.01332 14.5
250 12 21 8 7 0.0033 0.01348 15.0
1440 10 21 6 5 0.0014 0.01348 15.3
Washed Sieving
Sieve Size Diameter (mm) Mass Retained (g) Mass Passing (g) % Finer
#20 0.841 7.2 101.4 91
#40 0.425 14.2 87.2 78
#60 0.250 11.6 75.6 68
#100 0.150 7.4 68.2 61
#200 0.075 6.6 61.6 55