MONITORING REPORT EQUIPMENT PERFORMANCE

UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU


PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 8 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
MAXIMUM
TIME STANDARD 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 VALUE OF TIME STANDARD 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
CONDITION CONDITION CONDITION RESULT CONDITION CONDITION CONDITION
WATER SAMPLE WATER SAMPLE
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.155 0.124 0.196 0.196 Outlet Turbidity Value ≤ 20 NTU 0.155 0.124 0.196
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 3 NTU 0.087 0.098 0.188
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.01 0.02 0.03
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.02 0.01 0.02
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby 2740 Unit Standby
Conductivity Vessel #1 ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Conductivity Vessel #1 ≤ 2000 µs/cm 2800 2810
Conductivity Vessel #2 ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Conductivity Vessel #2 ≤ 2000 µs/cm 2060 2100
Conductivity Vessel #3 ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Conductivity Vessel #3 ≤ 2000 µs/cm 1241 1263
Conductivity Vessel #4 ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Conductivity Vessel #4 ≤ 2000 µs/cm 852 862
Conductivity Vessel #5 ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Conductivity Vessel #5 ≤ 2000 µs/cm 3870 3890
Conductivity Vessel #6 ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Conductivity Vessel #6 ≤ 2000 µs/cm 1750 1802
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm 2095.5 #DIV/0! 2121.16666667
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Conductivity Vessel #1 ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby Conductivity Vessel #1 ≤ 50 µs/cm 57.1 54.2
Conductivity Vessel #2 ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby Conductivity Vessel #2 ≤ 50 µs/cm 27 26.9
Conductivity Vessel #3 ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby Conductivity Vessel #3 ≤ 50 µs/cm 23.6 24.8
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0.0 Outlet Conductivity ≤ 50 µs/cm 35.9 #DIV/0! 35.3
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm 0.177 0.177 0.177 0.177 DD ≤ 0.2 µs/cm Unit Standby Unit Standby Unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 8 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
MAXIMUM
TIME STANDARD 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 VALUE OF TIME STANDARD 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.155 0.124 0.196 0.196 Outlet Turbidity Value ≤ 20 NTU 0.155 0.124 0.196
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 3 NTU 0.087 0.098 0.188
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.01 0.02 0.03
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.02 0.01 0.02
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby 0.02 Unit Standby
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm Unit Standby 2208.33333333 Unit Standby
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0.0 Outlet Conductivity ≤ 50 µs/cm Unit Standby 37.6 Unit Standby
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm 0.177 0.177 0.177 0.177 DD ≤ 0.2 µs/cm Unit Standby Unit Standby Unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 9 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 MAXIMUM TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
STANDARD VALUE OF STANDARD
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.145 0.176 0.193 0.193 Outlet Turbidity Value ≤ 20 NTU 0.145 0.176 0.193
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 3 NTU 1.042 0.085 0.046
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.02 0.01 0.01
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.029 0.037 0.039
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l 0.04 0.04 0.04
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm 2260.6 Unit Standby 2260.6
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0.0 Outlet Conductivity ≤ 50 µs/cm Unit Standby 37.6 34.0
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm Unit Standby Unit Standby unit Standby 0 DD ≤ 0.2 µs/cm 0.084 Unit Standby unit Standby
SiO2 ≤ 20 µg/l Unit Standby Unit Standby unit Standby 0 SiO2 ≤ 20 µg/l 1.4 Unit Standby unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 10 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 MAXIMUM TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
STANDARD VALUE OF STANDARD
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.145 0.176 0.193 0.193 Outlet Turbidity Value ≤ 20 NTU 0.145 0.176 0.193
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 3 NTU 1.042 0.085 0.046
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.02 0.01 0.01
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.029 0.037 0.039
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l 0.04 0.04 0.04
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm 2260.6 Unit Standby 2260.6
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0.0 Outlet Conductivity ≤ 50 µs/cm Unit Standby 37.6 34.0
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm Unit Standby Unit Standby unit Standby 0 DD ≤ 0.2 µs/cm 0.084 Unit Standby unit Standby
SiO2 ≤ 20 µg/l Unit Standby Unit Standby unit Standby 0 SiO2 ≤ 20 µg/l 1.4 Unit Standby unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 11 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 MAXIMUM TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
STANDARD VALUE OF STANDARD
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU Unit Standby 0.1 0.195 0.195 Outlet Turbidity Value ≤ 20 NTU Unit Standby 0.1 0.195
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU Unit Standby 0.045 0.074 0.074 Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby 0.01 0.01
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU Unit Standby 0.031 0.025
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby 0.01 0.01
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm Unit Standby 2450 1899
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 50 µs/cm Unit Standby 37.6 34.0
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm Unit Standby Unit Standby unit Standby 0 DD ≤ 0.2 µs/cm Unit Standby 0.08 0.077
SiO2 ≤ 20 µg/l Unit Standby Unit Standby unit Standby 0 SiO2 ≤ 20 µg/l Unit Standby 1.5 1.6
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 12 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 MAXIMUM TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
STANDARD VALUE OF STANDARD
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.201 0.182 0.07 0.201 Outlet Turbidity Value ≤ 20 NTU 0.201 0.182 0.07
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU 0.153 0.174 0.032 0.174 Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.01 0.02 0.01
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.059 0.038 0.003
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l 0.01 0.01 0.01
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm 1949.7 2194.5 2126
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 50 µs/cm 34.9 34.3 35.7
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm Unit Standby Unit Standby 0.109 0.109 DD ≤ 0.2 µs/cm 0.103 0.103 Unit Standby
SiO2 ≤ 20 µg/l Unit Standby Unit Standby 2.1 2.1 SiO2 ≤ 20 µg/l 2.6 2.6 Unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 13 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 MAXIMUM TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
STANDARD VALUE OF STANDARD
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.148 0.7 0.075 0.7 Outlet Turbidity Value ≤ 20 NTU 0.148 0.7 0.075
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU 0.065 0.692 0.029 0.692 Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.01 0.01 0.02
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.022 0.088 0.005
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l 0.01 0.01 Unit Standby
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm 2123 2096 Unit Standby
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 50 µs/cm 34.8 36.8 Unit Standby
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm 0.1 0.1 0.09 0.1 DD ≤ 0.2 µs/cm Unit Standby Unit Standby Unit Standby
SiO2 ≤ 20 µg/l 2.1 2.1 1.5 2.1 SiO2 ≤ 20 µg/l Unit Standby Unit Standby Unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
DATE : 14 AGUSTUS 2020

UNIT #1 UNIT #2
PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2 PERSONAL CHECK SHIFT 3 SHIFT 1 SHIFT 2
TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30 MAXIMUM TIME 23:30 - 07:30 07:30 - 15:30 15:30 - 23:30
STANDARD VALUE OF STANDARD
WATER SAMPLE CONDITION CONDITION CONDITION RESULT WATER SAMPLE CONDITION CONDITION CONDITION
RESULT RESULT RESULT RESULT RESULT RESULT
PREATREATMENT SYSTEM PREATREATMENT SYSTEM
FLOCCULATION SETTLING TANK FLOCCULATION SETTLING TANK
Outlet Turbidity Value ≤ 20 NTU 0.205 0.196 Unit Standby 0.205 Outlet Turbidity Value ≤ 20 NTU 0.205 0.196 Unit Standby
FINE SAND FILTER FINE SAND FILTER
Outlet Turbidity Value ≤ 3 NTU 0.116 0.162 Unit Standby 0.162 Outlet Turbidity Value ≤ 3 NTU Unit Standby Unit Standby Unit Standby
ULTRA FILTRATION ULTRA FILTRATION
Outlet Residual Chlorine Content ≤ 2 µg/l Unit Standby Unit Standby Unit Standby 0 Outlet Residual Chlorine Content ≤ 2 µg/l 0.02 0.02 Unit Standby
Outlet Turbidity Value ≤ 0.4 NTU Unit Standby Unit Standby Unit Standby 0 Outlet Turbidity Value ≤ 0.4 NTU 0.022 0.088 Unit Standby
DESALINATION SYSTEM DESALINATION SYSTEM
SALT WATER REVERSE OSMOSIS SALT WATER REVERSE OSMOSIS
Inlet Residual Chlorine Content ≤ 0.1 µg/l Unit Standby Unit Standby Unit Standby 0 Inlet Residual Chlorine Content ≤ 0.1 µg/l 0.01 Unit Standby 0.01
Outlet Conductivity ≤ 2000 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 2000 µs/cm 2095.5 Unit Standby 2121.2
BRACKISH WATER REVERSE OSMOSIS BRACKISH WATER REVERSE OSMOSIS
Outlet Conductivity ≤ 50 µs/cm Unit Standby Unit Standby Unit Standby 0 Outlet Conductivity ≤ 50 µs/cm 35.9 Unit Standby 35.5
DEMINERALIZE SYSTEM DEMINERALIZE SYSTEM
MIXED BED MIXBED
DD ≤ 0.2 µs/cm Unit Standby Unit Standby 0.098 0.098 DD ≤ 0.2 µs/cm Unit Standby Unit Standby Unit Standby
SiO2 ≤ 20 µg/l Unit Standby Unit Standby 2.4 2.4 SiO2 ≤ 20 µg/l Unit Standby Unit Standby Unit Standby
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
AUGUST : WEEK 2

UNIT 1
DATE OF EQUIPMENT MONITORING STATUS
SYSTEM OF EQUIPMENT NAME PARAMETER STANDARD
EQUIPMENT VALUE Saturday, August 08, 2020 Sunday, August 09, 2020 Monday, August 10, 2020 Tuesday, August 11, 2020 Wednesday, August 12, 2020 Thursday, August 13, 2020 Friday, August 14, 2020

FLOCCULATION
SETTLING TANK Outlet Turbidity Value ≤ 20 NTU 0 0.193 0.193 0.195 0.201 0.7 0.205

FINE SAND FILTER Outlet Turbidity Value ≤ 3 NTU 0 0 0 0.074 0.174 0.692 0.162
PRETREATMENT
SYSTEM Outlet Residual
Chlorine Content ≤ 2 µg/l 0 0 0 0 0 0 0
ULTRA FILTRATION
Outlet Turbidity Value ≤ 0.4 NTU 0 0 0 0 0 0 0

Inlet Residual Chlorine


≤ 0.1 µg/l 0 0 0 0 0 0 0
SALT WATER REVERSE Content
OSMOSIS
MONITORING REPORT EQUIPMENT PERFORMANCE
UNIT WATER TREATMENT PLANT PT. REKIND DAYA MAMUJU
PLTU 2 X 25 MW SULAWESI BARAT, MAMUJU
AUGUST : WEEK 2

UNIT 2
DATE OF EQUIPMENT MONITORING STATUS
SYSTEM OF STANDARD
EQUIPMENT EQUIPMENT NAME PARAMETER VALUE Saturday, August 08, 2020 Sunday, August 09, 2020 Monday, August 10, 2020 Tuesday, August 11, 2020 Wednesday, August 12, 2020 Thursday, August 13, 2020 Friday, August 14, 2020

FLOCCULATION Outlet Turbidity Value ≤ 20 NTU 0 0.193 0.193 0.195 0.201 0.7 0.205
SETTLING TANK

FINE SAND FILTER Outlet Turbidity Value ≤ 3 NTU 0 1.042 1.042 0 0 0 0


PRETREATMENT
SYSTEM Outlet Residual ≤ 2 µg/l 0 0.02 0.02 0.01 0.02 0.02 0.02
Chlorine Content
ULTRA FILTRATION
Outlet Turbidity Value ≤ 0.4 NTU 0.03 0.039 0.039 0.031 0.059 0.088 0.088

Inlet Residual Chlorine


Content ≤ 0.1 µg/l 0 0.04 0.04 0.01 0.01 0.01 0.01
SALT WATER REVERSE
OSMOSIS