Pages From TM 1-1520-280-23&P, Dated 09 March 2020, Distribution D, Revision 2 WP 2084

Selected Configuration: Show All Configurations M00007-1-1520-280-PMS

CHANGE 2
AVIATION MAINTENANCE COMPANY MAINTENANCE
POWER ON CHECKS

INITIAL SETUP:
Tools
Tool Kit, Aircraft General Mechanic (WP 2095, Item 59 [Maintenance Allocation Chart, Tool Kit
Aircraft General Mechanic])
Personnel Required
Avionics Mechanic 15N (1)
UH-60 Helicopter Repairer 15T (2)

SEQ. # ITEM AND PROCEDURE MH A B


HH-60M
7.1 Inspect external electrical rescue hoist as follows: 0.4 A B

Reel out entire length of rescue hoist cable.


Check cable for corrosion, kinks, separated strands, wear, and
broken or frayed wires. Pay particular attention to area around
hook.
Reel-in hoist cable. Use glove to protect hand while tensioning
cable. While reeling, wipe cable with clean heavy cloth.
HH-60M
7.2 Perform an operational check of medical interior equipment. 0.5 A B

7.3 Accomplish the following portions of the Digital Automatic Flight 0.2 A B
Control System (DAFCS) Fault Isolation Procedures (FIP):
Ensure DAFCS Setup Equipment Conditions (with the exception
of leveling the helicopter) are met.
Perform DAFCS Setup Procedure.
Perform DAFCS Status Procedure.
Perform DAFCS IBIT Procedure.
Perform all DAFCS Shutdown Procedure steps.
7.4 Inspect for foreign object damage and ensure all access panels, 0.1 A B
cowlings, and doors opened or removed for this inspection are
closed or installed.

Page 1 of 1 Printed on 13 Aug 2020 13:45:40