Professional Documents
Culture Documents
M100 Intercom Station Range and Accessories Catalogue
M100 Intercom Station Range and Accessories Catalogue
2
M100 S Intercom
Table of contents
© Sait-Stento 08-2000
Data subject to change without notice.
3
M100 S Intercom
Introduction
Greater efficiency
Modern, advanced communication
systems are designed to simplify contact
between individuals. In business and
industrial environments as well as in
public service institutions and health
care.
Versatile exchanges
The M100 range of exchanges is
multipurpose communication exchanges
designed to utilise various types of user
terminals, using a single or dual pair star-
cabled configuration.
4
M100 S Intercom
Standard stations
LBB 7089/10 LBB 7089/15 LBB 7089/31
Desktop master station Compact master station Single call station
5
M100 S Intercom
Standard stations
LBB 7089/32 LBB 7089/16 LBB 7089/18
Dual call station Compact master display station Compact master display station
with backlight
7
M100 S Intercom
Industrial stations
LBB 7089/21 Technical data Technical data
Industrial single call station Dimensions (wxhxd): 130x265x75 mm Dimensions (wxhxd): 130x265x75 mm
5.12x10.43x2.95 in 5.12x10.43x2.95 in
Wall cut-out for flush Wall cut-out for flush
mount 100x227x60 mm mount 100x227x60 mm
Weight, net: 1.4 kg Weight, net: 1.4 kg
3.08 lb 3.08 lb
Environmental conditions: Environmental conditions:
Protection by enclosure IP 54 Protection by enclosure IP 54
(front access) (front access)
Supply voltage: Supply voltage:
Extension line Idle 10 V d.c., Extension line Idle 10 V d.c.,
in operation 36 V d.c. in operation 36 V d.c.
Current consumption: Current consumption:
Extension line Idle <0.3 mA, Extension line Idle <0.3 mA,
in operation 25-38 mA in operation 25-38 mA
Output power 90 mW continuous, Output power 90 mW continuous,
300 mW peak 300 mW peak
Cabling: Cabling:
Extension line 2-wire Extension line 2-wire
Power line (for kits) 2-wire Power line (for kits) 2-wire
LBB 7089/22
Application areas
Industrial dual call station
The industrial single call station is designed for
quick single key access to one pre-determined
station in any M100 system. Ideal for use at doors,
gates or in lifts as well as protected outdoor
environments. The station is delivered as a flush
mount unit with die-cast zink alloy front lacquered
in a light grey colour. It has a built-in directory list
and splash-proof front. Volume is preset in each
station.
Functional description
Kits are available for use with a door- opening
mechanism for remote door opening. Kits must
be powered separately. In operation the station is
loudspeaking and handsfree. Outgoing calls are
made to one pre-programmed location by pressing
the call button. The call will be in direct or indirect
mode according to pre-programming. If in
indirect mode the call has to be accepted by the
receiver before normal duplex conversation can be The industrial dual call station is identical
established. A station can be progrmmed to reset a to the industrial single call station but
call if not answered within a pre-programmed equipped with two call buttons and a
time-frame. Any station in the system can reach the cancel button.
single call station by dialling the The industrial dual call station has access
station’s extension number. to two pre-programmed locations.
8
M100 S Intercom
Heavy duty stations
LBB 7089/40 maximum adaptation to the local LBC 3490/10
Heavy duty master station acoustical situation. Loudspeaker horn, 16 ohm
Technical data
This 10 1/2” x 7” loudspeaker is designed
Dimensions (wxhxd): 160x260x106 mm
6.30x10.24x4.17 in for use with the heavy duty master station
Weight, net: 2.7 kg either outdoors or in industrial buildings
6.0 lb and yards.
Environmental conditions:
Protection by enclosure IP 65
Temperature range -15o to +45oC The horn is splash and dust-proof, made
-25oC with heating kit from aluminium and is supplied with an
Supply voltage: adjustable mounting bracket.
Extension line Idle 10 V d.c.,
in operation 36 V d.c. Technical data
Application areas Power line 24-40 V d.c. or
Power handling capacity: cont. 10 W
The heavy duty master station is for use 18-30 V a.c.
Current consumption: Rated impedance: 16 ohm
in severe indoor or outdoor applications.
Extension line Idle <0.3 mA, Eff.freq.range (-10 dB): 410-3900 Hz
The station is especially designed for in opration 25-38 mA Water and dust protection: IP 65
withstanding rigorous environments Power line Idle <40 mA, Overall length: 276 mm
including temperature extremes and dusty 200 mA
(24 V d.c. unstabilized power supply) 3.0 in
and corrosive atmospheres.
at 16 W peak Weight: 1.25 kg
Output power: 16 W peak 2.8 lb
A heavy duty handset kit may be fitted for in 16 ohm loudspeaker horn
use in noisy areas or for confidential calls. Cabling:
Volume is preset in each station. Extension line 2-wire
Functional description
Large keys provide for convenient
operation even when wearing protective
gloves. Built-in microphone and high
power external loudspeaker horn enable
9
M100 S Intercom
Heavy duty stations
It is ideal for use at doors or gates in a Technical data for LBB 7089/41 and /42
LBB 7089/41 heavy duty environment or outdoors and
Heavy duty single call station Dimensions (wxhxd): 128x265x75 mm
exposed to all weather conditions. 5.04x10.43x2.95 in
A heating kit may be mounted where Wall cut-out for
extreme low temperatures are expected. flush mounting 100x227x60 mm
A weather protection frame is available for 3.93x8.94x2.36 in
further protection from rain, sleet and Weight, net: 1.4 kg
snow. 3.08 lb
Environmental conditions:
Functional description Protection by enclosure IP 54/IP 65
when properly sealed
By pressing the station’s call button an
Temperature range -15o to +45oC
direct or indirect call will be initiated to a Supply voltage:
pre-determined location. Extension line Idle 10 V d.c.,
Indirect call must be accepted by the in operation 36 V d.c.
called station before normal duplex Power line 24-40 V d.c. or
conversation can be established. 18-30 V a.c.
Volume is pre-set in each station. Current consumption:
A station can be programmed to reset a Extension lines Idle <0.3 mA,
call within a pre-programmed time frame in operation 25-38 mA
if an outgoing call is not answered. Output power: 90 mW continuous,
300 mW peak
Cabling: 2-wire
LBB 7089/42
Heavy duty dual call station
Application areas
The heavy duty single call station is
designed for quick single key access to one
pre-determined station in any
M100 S system.
A heavy duty handset can be added
according to environment.
The station can be called by any other
station in the system.
Kits are available for remote door
opening, external call by lamp or bell
and/or high output power in external
horn loudspeaker. Kits must be powered
separately.
Microphone cover, special loudspeaker
protection, heavy duty call button and
special silicone sealing of the printed
circuit board make the station suitable for
installation in heavy duty environments. Application areas
The station will withstand temperature This station is identical to the heavy duty
extremes as well as dusty, humid and single call station but is equipped with 2
corrosive atmospheres. A large key call buttons and a call cancel button.
provides convenient operation even when The heavy duty dual call station has access
wearing protective gloves. to two pre-determined stations.
By adding an optional on wall back box
the station will be transformed into a Functional description
heavy duty, self-contained on wall unit. The cancel button is used to cancel a call.
10
M100 S Intercom
Explosion-protected stations
LBB 7089/50 LBB 7089/52 LBB 7071/10
Explosion protected master Explosion protected dual call Flame-proof loudspeaker
station station horn, 8 W/8 ohm
The station is housed in a splash-proof The station is housed in a double housing The heavy duty flame-proof loudspeaker
dark grey cabinet for wall mounting. for wall mounting and consists of a flame- horn specially designed for use in areas
The cabinet is made of glass fibre re- proof box for the electronics and a splash- where gasses or other explosives dictate
inforced, self-extinguishing polyester proof dark grey polyester box for the special precautions. Suitable for use with
resin. All electronics are installed in an keyboard and cabling. explosion-protected master stations.
inner flame-proof box. The station The loudspeaker is completely weather-
operates in duplex with a built-in The keyboard/cabling box is made of proof, is resistant to salt-laden air and
microphone and amplifier for high output glassfibre reinforced, self-extinguishing unaffected by most chemicals. Made in
to a flame-proof loudspeaker horn. The polyester resin. cast silumin with grey epoxy finish.
keyboard has large keys for ease of
operation. Controls for simplex mode The station has access to 2 pre-defined Classification Explanation
and system functions are identical to all locations. EEx Explosion-proof apparatus
other M100 stations. e Increased safety
Privacy and external volume controls are d Flame-proof enclosures
not available. [ib] Safety barrier
II For use in places with a
Technical data Technical data potentially explosive
Dimensions (wxhxd): 340x340x150 mm Dimensions (wxhxd): 170x340x150 mm atmosphere
13.39x13.39x5.91 in 6.69x13.39x5.91 in C Gas group
Weight, net: 8 kg Weight, net:
(Acetylene/Hydrogen)
17.6 lb
Environmental conditions: Environmental conditions: T6 Maximum surface
Classification EExed(ib)IIC T6 Classification EExed(ib)IIC T6 temperature = 85oC
Protection IP 65 Protection IP 65
Supply voltage: Supply voltage:
Extension line Idle 10 V d.c., Power line 18-32 V d.c. Technical data
in operation 36 V d.c. Current consumption: Nominal impedance: 8 ohm
Power line 18-32 V d.c. Power line 900 mA max. Rated power: 8W
Current consumption: Output power: 5 W, 8 ohm
Extension line Idle <0.3 mA, Cabling: Frequency range: 100-5000 Hz
in operation 25-38 mA Extension line 2-wire Protection: IP 67
Power line 900 mA max. Dimensions,
Output power: 5 W, 8 ohm front and depth: 124 x 116 mm
Cabling:
4.88 x 4.57 in
Extension line 2-wire
Net weight: 1.8 kg, 4.0 lb
11
M100 S Intercom
Special stations
LBB 7089/96 Technical data There is no possibility for initiating calls
Chemical resistant master Dimensions (wxhxd): 130x265x60 mm Loudspeaking, handsfree station with
5.12x10.43x2.36 in
station Weight, net: 450 g
separate input for television audio.
0.99 lb
Environmental conditions: A total of 8 audio channels can be selected
Ambient temperature range 0-45oC from the operator panel, where channel 8
Relative humidity 10-95% may be used for TV-sound.
Protection IP 65
Supply voltage:
Intercom line, nominal 36 V d.c. LEDs indicate selected programme and
Curent consumption: volume can be adjusted up and down.
Intercom line, station OFF 0.3 mA Separate OFF button.
Intercom line, station ON 38mA
Power output: 90/300 mW
Cabling: Technical data
Extension line 2-wire Dimensions (wxhxd): 93x224x70 mm
3.7x8.8x2.8 in
Weight, net: 675 g
1.5 lb
LBB 7089/97 Environmental conditions:
Programme distribution Ambient temperature range 0-45oC
station Relative humidity 10-95%
Protection IP 40
Supply voltage:
Intercom line, nominal 36 V d.c.
Curent consumption:
Intercom line, station OFF 0.3 mA
Intercom line, station ON 38mA
Power line idle 20 mA
Power line at max. output 150 mA
The chemical resistant master station is Power output: 300 mW/1 W
Cabling:
designed for efficient, loudspeaking, Extension line 4-wire
handsfree communication in any
M100 Intercom & Nurse call system.
It is delivered as a flush mount unit,
especially developed for use in hospital
operating theatres or clean room
environments.
The station front is covered by a
polyester foil which is resistant to most
fluids and detergents.
An optional back box enables for on wall
mounting.
Keyboard without buttons for simplex
mode and system functions, as well as +/-
buttons for accepting and rejecting
certain functions.
The station is made for on-wall or flush
A call tone and a pilot lamp indicate
mounting and intended for use in staff
connection. The volume is internally pre-
rooms or patient living rooms.
set in each station.
The station may also be called in indirect
Provision is made for programme
mode, i.e. calls must be accepted before
distribution or calls for duplex
duplex connection can be established.
conversation and announcements from
A handset may be installed to provide for
other stations in the system.
lowspeaking conversation.
12
M100 S Intercom
Special stations
LBB 7089/60 Technical data Functional description
Access station Dimensions (wxhxd): 130x265x75 mm The Audio alarm interface is a modified
5.12x10.43x3 in intercom station for use as an automatic
Weight, net: 1.4 kg
emergency call transmitter in an alarm
3.08 lb
Environmental conditions: situation.
Ambient temperature range 0-45oC
Relative humidity 10-95% The interface cannot receive or initiate
Protection IP 54/64 normal intercom calls and has to be
when properly sealed
Supply voltage: connected to an alarm central (exchange).
Intercom line, nominal 36 V d.c.
Curent consumption: A relay contact closure in the alarm central
Intercom line, station OFF 0.3 mA will trigger a group call, all call or
Intercom line, station ON 38mA
emergency call from the audio alarm
Power output: 90/300 mW
Cabling: interface.
Extension line 2-wire
A pre-recorded message or alarm signal
initiated from the alarm central will be
distributed to all called stations from the
LBB 7109/50 audio alarm interface.
Audio Alarm Interface
Technical data
Dimensions (wxhxd): 93x65x224 mm
3.7x2.6x8.8 in
Weight, net: 0.36 kg
0.8 lb
Environmental conditions:
Application areas Ambient temperature range 0-45oC
For use with ACS-16 Audio Switch. Relative humidity 10-95%
The station is delivered as a flush mount unit Protection IP 40
and designed for use in light industrial and Supply voltage:
Intercom line, nominal 36 V d.c.
protected outdoor environments.
Curent consumption:
Volume is pre-set in each station. Intercom line, station OFF 0.3 mA
Intercom line, station ON 38mA
Functional description Power output: 90/300 mW
The foil key board contains 0-9 keys, two call Cabling:
Application areas Extension line 2-wire
buttons A and B and a reset button. Access can
The Audio alarm interface is for use in
be obtained by keying the access code when
schools or other public areas where there
known and the door will open.
is a need for distribution of alarm
If the access code is not known the call buttons
messages in emergency situations.
A and B should be used. This will initiate call to
The Audio alarm interface should,
a pre-programmed control station(s) with
however, not be used as the sole alarm
remote door opening function.
message system but as a supplement to
alarm bells, alarm loudspeakers, etc. to
give a general message or instructions to
the public.
13
M100 S Intercom
Data - special stations
Environmental conditions
-Category : T2 T2 T3 T1
-Ambient temperature range : 0-45oC
-Relative humidity : 10-95%
-Protection : IP 65 IP 40 IP 54/64 when IP 40
properly sealed
Supply voltage
-Intercom line, nominal : 36 V d.c. 36 V d.c. 36 V d.c.
(extension line)
-Intercom line, min./max. : 13 - 40 V
Current consumption
-Intercom line, station OFF : 0.3 mA 38/0.3 mA 0.3 mA
(extension line)
-Intercom line, station ON : 38 mA 38 mA
-Power line idle : 20 mA
-Power line at max. output : 150 mA
Cabling
-Extension line : 2-wire 2-wire
14
M100 S Intercom
Station kits and coupler
LBB 7072/10 LBB 7072/32 LBB 7999/35
Master station kit Single/Dual call station kit S Public Address coupler
The kit is a complete master station The kit is a complete single/dual call M100 P.A. coupler for connection to any
delivered without housing, intended for station delivered without housing, line point in the system provides interface
self-mounting or as a spare part kit for intended for self-mounting or as a spare to a Public Address system.
M100 master stations. part kit for single/dual call stations.
The functions available from the station The functions available from the station
The P.A. coupler may be called from any
kit will depend upon the exchange and kit will depend upon the exchange and
software used. station.
software used.
The kit contains the following parts:
The kit contains the following parts: When called, a relay contact for e.g.
- loudspeaker including wires with
switching on the P.A. amplifier, is
connector
- loudspeaker including wires with activated and the audio line is connected
- complete keyboard with all master
connector to the input of the amplifier
station keys and mounting frame
- an “A” and a “B” key for calling pre- (600 ohm/0 dBm).
- electret microphone with wires and
set numbers
connector
- cancel key
- station PCB with keyboard - red LED lamp for indication of
connector station in use
- 4-wire station cable with open ends - electret microphone with wires and
connector
Technical data - station PCB with single on-line key-
Loudspeaker: board connectors
Weight 115 g - station board mounting frame
0.3 lb - 4-wire station cable with open ends
Diameter 60 mm
2.4 in Technical data Technical data
Microphone: Loudspeaker: Dimensions (wxhxd): 65x120x40 mm
Weight 1g Weight 115 g 2.56x4.72x1.57 in
0.002 lb 0.3 lb Weight: 100 g
Diameter 5 mm Diameter 60 mm
0.22 lb
0.2 in 2.4 in
Microphone: IP code: IP 42
Print board:
Weight 40 g Weight 1g
0.8 lb 0.002 lb
Dimension, wxh 80 x 110 mm Diameter 5 mm
3.1x4.3 in 0.2 in
Keyboard: Print board:
Weight 40 g
Weight 40 g
0.8 lb
0.11 lb
Dimension, wxh 80 x 110 mm
Dimension, wxh 80 x 80 mm
3.1x4.3 in
3.1x3.1 in
(other components as for LBB 7072/32)
15
M100 S Intercom
Station accessories
HANDSET KITS BACK BOXES AND FRAMES
LBB 7073/63
LBB 7073/82 LBB 7073/84 Flush mount back box, 75 mm
Handset with cradle kit Cradle bracket
LBB 7069/08
Wall socket, 6-pole
Requires soldering of the installation cable
inside the socket.
LBB 7069/18
6-pole plug, male
LBB 7069/21
Metal frame lacquered in grey for Wall socket, RJ45, 4-pole
weather protection of industrial stations. This socket has screw connection for the
Dimensions(wxhxd): 140x272x80mm installation cable.
5.51x10.79x3.15 in
LBB 7069/62
LBB 7073/74 Station cord, RJ45 connector
Outdoor station heating kit
LBB 7069/63
Station cord, 6-pole connector
LBB 7069/64
Station cord, RJ45
interconnector
This interconnector is used to extend the
station cable by connecting two or more
station cords in series.
A heating kit may be mounted for
outdoor stations located where extremely
low temperatures can be expected. Also LBB 7095/01
suitable for absorbing condenced water. Power supply, 24 V/40 W
Dimensions (wxhxd): 91x96x20 mm Euro connector
3.58x3.78x0.79 in
Weight, net: 90 g
0.2 lb
Power rating: 12 W at 24 V
maximum: 25 W at 36 V
Expected temperature
elevation at 12 W: +10oC
17
M100 S Intercom
Function Kits
LBB 7073/65 LBB 7073/67 Technical data
Audio/Relay kit Relay kit
External call/door-opening
Relay ratings:
Relay timing 0.8 - 35 sec.
Maximum switchable
voltage 50 V d.c./125 V a.c.
Maximum
switchable current 1A
LBB 7073/66
Audio kit 16 W Amplifier
Supply voltage:
From external power,
maximum 36 V d.c./30 V a.c.
From external power,
minimum 24 V d.c./18 V a.c.
This kit includes a 16 W peak power
amplifier for use with external loud-
Current consumption:
speaker or for improved internal loud-
From unregulated
speaker performance. Relay function with
power supply or a.c. 200 mA average
adjustable timer for activating an external call
This kit includes a 6 W peak power at 16 W
device or for remote door-opening function.
amplifier for external or improved From regulated power 800 mA max.
Interface circuitry for connection of heavy
internal loudspeaker performance.
duty handset. Opto coupler output for
Interface circuitry for connection of
station “on” signal to external equipment. 24
heavy duty handset. Can be mounted in
V station “on” lamp driver. Can be mounted
all stations or back boxes.
in all back boxes. Included in LBB 7089/40.
Needs external power supply.
Needs external power supply.
Dimensions (wxhxd): 70x24x68 mm
Dimensions (wxhxd): 102x48x130 mm
2.76x0.94x2.68 in
4.02x1.89x5.12 in
Weight net: 55 g
Weight net: 160 g
0.1 lb
0.4 lb
18
M100 S Intercom
Stations and accessories combinations
Accessories
Stations
STANDARD STATIONS
LBB 7089/10 Desktop master station u u --- --- § --- --- --- --- --- --- --- --- l ---
LBB 7089/15 Compact master station --- u u --- § --- § § u § u --- --- l ---
LBB 708916 Compact master display station --- u u --- § --- § § u § u --- l l ---
LBB 7089/18 Compact master display w/back light --- u u --- § --- § § u § u --- l l ---
LBB 7089/31 Single call station --- u u --- § --- § § u § u --- --- l ---
LBB 7089/32 Dual call station --- u u --- § --- § § u § u --- --- l ---
INDUSTRIAL STATIONS
LBB 7089/20 Industrial master station --- u --- § § --- u u u u --- u --- u §
LBB 7089/30 Industrial master display w/back light --- u --- § § --- u u u u --- u l u §
LBB 7089/21 Industrial single call station --- u --- § § --- u u u u --- u --- u §
LBB 7089/22 Industrial dual call station --- u --- § § --- u u u u --- u --- u §
HEAVY DUTY STATIONS
LBB 7089/40 Heavy duty master station --- --- --- u l --- --- --- --- --- --- --- l --- u
LBB 7089/41 Heavy duty single call station --- u --- § § --- u u o u --- u --- § §
LBB 7089/42 Heavy duty dual call station --- u --- § § --- u u o u --- u --- § §
SPECIAL STATIONS
LBB 7089/50 Explosion-protected master station --- --- --- --- --- l --- --- --- --- --- --- l --- ---
LBB 7089/52 Explosion-protected dual station --- --- --- --- --- l --- --- --- --- --- --- l --- ---
LBB 7089/96 Chemical resistant master station --- u --- --- § --- u u --- u o --- --- l ---
LBB 7089/60 Access station --- u --- § § --- u u u u --- u --- u §
LBB 7072/10 Master station kit --- u --- § § --- --- --- --- --- --- --- --- u ---
LBB 7072/32 Single/Dual call station kit --- u --- § § --- --- --- --- --- --- --- --- u ---
u = Possible
--- = Not possible
o = Included
l = Required
§ = Possible in combination
with other accessories
19
M100 S Intercom
Kits and accessories combinations
STATIONS
Accessories
Kits
KITS
LBB 7073/65 Audio/Relay kit uu u | u u u § uu | u u| | uu uu u | u uu u | l |
LBB 7073/66 Audio kit uu u | u u u § uu | u u| | uu uu u | u uu u | l |
LBB 7073/67 Relay kit uu u | u u u § uu | u u| | uu uu | | u uu u | | |
LBB 7073/68 Application kit | § § | § § § § § § o§ § | | §§ u u | u u| u | l |
LBB 7073/74 Outdoor station heating kit | | | | | | § § § § u§ § | | | § | | | | u u| u | | |
u = Possible
| = Not possible
o = Included
l = Required
§ = Possible in combination
with other accessories
20
M100 S Intercom
Typenumber survey
Page
21
M100 S Intercom
22
M100 S Intercom
23
M100 S Intercom