Cut Through The Complexity of Machinery Analysis With High Frequency Vibration Analysis
Cut Through The Complexity of Machinery Analysis With High Frequency Vibration Analysis
Cut Through The Complexity of Machinery Analysis With High Frequency Vibration Analysis
Emerson Confidential
Centrifugal pump
– Belt driven
– 869 RPM
– Variable speed
Funny Noise
Emerson Confidential 2
Standard vibration data
– Bearing faults
– Gear mesh in gear boxes
– Looseness
– Lubrication faults
– Cavitation
How creating a Vibration Spectrum
Amplitude
Amplitude
Amplitude
Tim
e
Emerson Confidential 8
Demodulation
BPFO
FFT
Frequency
Emerson Confidential 9
PeakVue
FFT
Frequency
Emerson Confidential 10
How does it work?
The diagram below shows sampling of data using normal data collection
Instantaneous Samples
How does it work?
The diagram below shows sampling of data using PeakVue data
collection.
PeakVue samples
How Does it work?
– After collecting all the samples PeakVue discard samples so there remain
only as many samples per second as the regular data collection would use
for a certain Fmax
How Does it work?
PeakVue time
waveform
Standard time
Sampling time waveform
PeakVue samples
When using PeakVue, keep in mind:
• Sensor Mounting effects frequency range
– More rigid mounting = Higher frequency range
– Mount the sensor on a paint free clean surface if possible
– 100 mV/g accelerometer is typically used
Emerson Confidential 15
Earlier detection of integrity degradation
Emerson Confidential 16
Any Questions?
Dieter Charle
BDM Portable Reliability Solutions
Dieter.charle@emerson.com
+32 493 229 991
M1
M2
G1
G3
G4
G5
G6
G7
G8
G10
G9
G12
G11
The standard spectrum was taken
Is there a problem?
Case Study: PeakVue data
• PeakVue spectrum:
M1
– Distinct peaks at 6,91 Hz and harmonics
– Corresponds to the running speed of the third shaft
M2
G1
G3
G4
G5
G6
G7
G8
• PeakVue time waveform:
– One big impact per revolution at G5
G10
G9
– Amplitude level of approximately 13 g Peak-to-Peak
G12
G11
Case Study: The fault
Examination suspected a gear fault at G5
M1
caused by damaged tooth
M2
G1
G3
G4
G5
G6
G7
G8
G10
G9
G12
G11