AUR INSTRUCTION MANUAL 95(116)

Document Id: IMW623C


A
MARIN
E TYPE 6.23.1
29 AUTO FILTER

29.1 Starting-up

Open stop valves at the filter inlet and outlet.

Check for presence of control air at the required pressure of 4 to 10 bars.

Switch on the main switch at the EL-control panel. The filter is ready for operation.

Set change-over valve plug to position I (see figure 1).

Switch the pump on.


Trigger a flushing cycle by actuating the "Manual" function at the EL-control panel.
This vents the filter housing of the automatic press filter, i.e. the air held in the filter is
discharged by the liquid pressure via the flushing arrangement into the flushing oil
piping.

Unscrew venting screw (cover retainer) of the by-pass filter.

Change-over valve plug to position II (see figure 1). Through this pressure equalising
position, the housing of the by-pass filter is slowly filled up and vented through the
venting screw.

Close venting screw and return valve plug to position I.

The automatic press filter is now in operation, while the by-pass filter is on standby,
i.e. during maintenance work on the automatic press filter the by-pass filter can by
setting the plug to position IV (see figure) be immediately put into the filter circuit and
the automatic press filter taken out of operation.

AURAMAR1NE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
~==.MARHME

29.2 Maintenance

A For all maintenance operations, the filter must be taken out of service and the air supply
shut off!

To maintain trouble-free operation, the points listed below must be observed when carrying out
maintenance work.

Remove and check the screen insert initially after about 50 hours of operation, then after
250, 500 and later every 1000 hours of operation.

Since even with automatic filters the possibility cannot be excluded that in the course of time
and depending on the nature of the medium dirt particles may accumulate in the fabric of the
filter elements and lead to encrustation, the screen discs must, when that happens, be
soaked for about 4 hours in a suitable carbon remover e.g. Filter-clean or B85 of Vecom or
others.

Then using the flat yet nozzle of the Boll cleaning unit type 5.04 or another available high
pressure cleaning lance the wire mesh of the discs should be thoroughly washed section by
section. After drying with compressed air, check the discs regarding cleaning effect and
eventual damages.

The fabric must not be damaged.


Damaged screen discs or screen discs, which cannot be cleaned, must be changed.

A Stubborn deposits on the screen discs can be removed in ultrasonic cleaning plants. This
must be done expertly, however, since the fabrics may otherwise be damaged as a result
of:

a) excessively long exposure (5 minutes max.)


b) excessively high frequency
c) local abrasions on the fabric through inexpert positioning in the ultrasonic bath.

Check movable internal components of the flushing arrangement inside the screen support body for
easy movement and possible signs of wear. Check seals for wear and replace if necessary.
MARINE

29.2.1 Maintenance instructions (automatic press filter)

A See drawing 1-25415 or 1-25237 resp. for type 6.23

For all maintenance operations, the filter must be taken out of service and the air
supply shut off!

Removal of the screen insert

Unscrew control air pipework (item 65) at the cylinder cover (item 3).

Slacken screws (item 25) and pull off cylinder cover upwards.

Pull screen insert out of the housing complete with flushing arrangement.

Unscrew slotted nut (item 43) and pull screen discs (item 5) off the support
body (item 4).

A
To slacken the slotted nut, do not clamp the support body on the
sealing surfaces or piston rod. Two clamping surfaces have been
provided for this purpose on the upper side of the support body.

The starting torque at reinstall for the slotted nut (item 43)

DN 32 40 Nm
DN 40; 50 48 Nm

Removal of the flushing arrangement

Remove screen insert as described above.

Slacken self-locking nut (item 37) and pull piston (item 12) off the piston rod
(item 10).

To counteract the torque when slackening the nut, use a drift or similar,
which is inserted into the transverse bore of the piston rod underneath
the piston.

Pull the piston rod out of the support body complete with flushing plate (item
6).

After removing the circlip (item 39), the flushing plate can be pulled off the
piston rod.

The sludge drain reducer (item 11) at the end of the piston rod is at the same
time used as the valve cone for the flushing oil valve and can be unscrewed
from the piston rod for cleaning or for replacement in the ease of damage.
AURA INSTRUCTION MANUAL 98(116)
Document Id: IMW623C
— ^MARINE
Removal of the flushing oil valve

Remove screen insert as described above.

Unscrew the sludge drain guide (item 8), which is in the form of a
hexagon, from the filter housing with a box spanner.

Remove the guide bush (item 9) after releasing the circlip (item 40).

Remove circlip (item 39) and push valve seat (item 7) upwards out of
the sludge drain guide.

29.2.2 Maintenance instructions (by-pass filter) (See drawing 1-25238)

Take the by-pass filter out of operation before carrying out maintenance work
on it!

To remove the screen insert, proceed as follows:

Slacken venting screw (item 132) of the cover retaining arrangement,


and in this way check that the filter housing is not pressurised.

Unscrew the venting screw until the cover panel (item 135) over the
concealed cover screws (item 123) can be swivelled.

Remove cover (item 106) after slackening the cover screws and pull
screen insert out of the filter housing.

Clean screen insert with suitable solvents (see KV349) and then blow through
with compressed air from the outside to the inside.

Check seals and replace any damaged seals.

Assemble filter in the reverse order and prepare by-pass filter for
operation as described in the section "Starting-up".

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
Specification Protection class: IP 65
Electr.Data: Switching voltage V = Max. = 250 220
Frequency Hz=Max. = 0-60 0-60
Switching current A = Max = 1 0.8
Making and/or breaking capacity
W/VA Max.= 60/60 40/60
Material: GD-Aluminium
Rating: Max.Pressure 100 bar
Max.Temperature 150°C
Ranges of Pressure Delta P = 0-0.5 bar
Differential 0-0.8 bar to be specified
0-1.2 bar when
ordering 0-2.0 bar 0-
3.0 bar
Description:

The purpose of this device is the measurement, and visual indication of the difference in pressure between two
points, and the establishment of an electrical contact when the pressure differential attains specified figure.

Method of operation

A plunger sealed by diaphragm separates the space under pressure int two chambers. A pre-loaded spring
causes the plunger to take up its zero position when pressure difference delta P is zero. As the pressure
difference increases(delta P >0), the plunger is forced to miove against the spring. At the same time, an indicator
disc is moved magnetically, and therefore virtually without friction, and the two reed contacts are actuated.
The red segment of the indicator disc is visible over a pressure range equal to 20%-100% delta P. The firast
reed contact is actuated at 75% delta P, and the second at 100% delta P

Differential pressure contact indicator.


AURA INSTRUCTION MANUAL 100(116)
~ = MAHINE Document Id: IMW623C

Ajsal
cht X
Vi»#X

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
AUR INSTRUCTION MANUAL 101(116)
Document Id: IMW623C
A
MARIN
29.3 Spare partElist
Bei ei ier Erzatzteilbestellung beneitigen wir When ordering for spares we need following L ors d'une commande de pieces rechange les
folgen de Angaben: informations s indications uivant sant n^cessaires )No de
1) r.-nn 1)Order 1 commande:
Auft 6.23 no: 2 )Type:
2) itzteilzeichnung: 2)Type: 3 )Plan des pieces de rechange
Typ
4.POS Nn 3)Spare p arts drawinq no: 4 No: )Pos:
5)Bez eihnunq: 4) Pos.no: 5 )D6siqnation:
6)DN: 5)Desiqna tion: 3 )DN:
7)lder tnummen 6)DN: 7 )No de code:
7):Code
no:
Bezeihunq DN32 DN40 DN50 DN
Bezeihunq DN32 DN40 DN50 DN
Pos designation Stick Identnummer Stick Identnummer Stick Identnummer Stick Identnummer
Pos designation Stick Identnummer Stick Identnummer Stick Identnummer Stick Identnummer
Nr. Code No/No. de code
Nr. parts
parts parts Code No/No. de code parts
parts parts parts Code No/No. de code
parts
desgination piece piece Code No/No. de code piece Code No/No. de code piece Code No/No. de code
desgination piece Code No/No. de code piece piece Code No/No. de code piece
Dichtung
Gehause
181 Gasket 1
1 2-219
Z25036 11 2-223
Z25464 11 2-223
Z25500
Housinq
Joint
Corps
Dictung
19 Gasket 2 2-115 2 2-118 2 2-118
Joint
Dichtunq
Deckel
203 Gasket
Cover 2
1 35x42x1.5
3-25045 21 78x94x1.5
3-25466 21 78x94x1.5
3-25502
Joint
Couverde
Stuetzkoerper
4 Filter element support 1 Z25125 1 Z25479 1 Z25505
Corps
Dichtunq
Siebscheibe
225 Gasket • 1 35x42x1.5 110 35x42x1.5 115 35x42x1.5
Filter element 13 3-25125 3-25510 3-25510
Joint
Filtre de rechanqe
Spuekteller
6 Flushing disc 2 4-25073 2 4-25483 2 4-25483
Assiette de nettoyaqe
Ventilsitsz
7 Valve seat 1 4-251127 1 4-25127 1 4-25127
Seiqe du soupape
Schraube
Schlammablassfuehrun
Bolt
25 J____________________
6 M10x30 6 M12x30 6 M12x30
8 Vis
Sludge drain 1 4-25239 1 4-25239 1 4-25506
Schraubedes boues
conduite
26 Bolt 8 M10x40 8 M12x50 8 M12x50
Fuehrunqsbuchse
9 Vis
Guide 1 4-24881 1 4-42881 1 4-42881
Boite quide
Kolbenstanqe
10 Piston rod 1 3-25079 1 3-25485 1 3-25503
Schraube
Tiqe de piston
28 Bolt 4 M10x25 4 M10x25 4 M10x25
Schlammablassdrossel
11 Vis
Throttle 1 4-25086 1 4-25488 1 4-25488
Schraube
Etranqler
29 Bolt 2 M10x16 2 M10x16 2 M10x16
Dichtkolben
Vis QTDF40.8 AGU QTDF QTDF 50.10 AGU
12 Piston 1 1 1
Schraube
Piston
01 50.10AGU 01 01
30 Bolt 4 M5x16 4 M5x16 4 M5x16
Vis
Schraube
31 Bolt 2 M5x50 2 M5x50 2 M5x50
Vis
Schraube
32 Bolt 4 M6x16 4 M6x16 4 M6x16
15 Dichtunq
Vis
Gasket 1 2-117 1 2-117 1 2-117
Schraube
Joint
33 Bolt 2 M8x25 2 M10x30 2 M10x30
Dichtunq
Vis
16 Gasket 1 2-123 1 2-123 1 2-123
Schraube
Joint
34 Bolt 8 M10 8 M12 8 M12
17 Dichtunq
Vis
Gasket 1 2-247 1 2-247 1 2-247
Joint

Spare parts list Ersatzteilliste 6.23 list des parts de rechange


Mutter
04.01.94 Boll&Kirch filterbau GmbH Z25415BL(5)
36 Nut 4 M6 4 M6 4 M6
Ecrou
Mutter
37 Nut 1 M8 1 M8 1 M8
Ecrou
Mutter
38 Nut AURAMARINE LTD
2 M8 849
P.O.BOX 2 M10 2 M10 Tel + 358 204 86 5030
Ecrou FIN-20101 Fax + 358 204 86
TURKU 5031
spare parts list Ersatzlist 6.23 list des parts de rechange

04.01.94 Boll&Kirch filteraubau GmbH Z25415BL.3(5)


Bezeihung DN32 DN40 DN50 DN
Pos designation Stick Identnummer Stick Identnummer Stick Identnummer Stick Identnummer
Nr. parts parts Code No/No. de parts parts Code No/No. de
desgination Code No/No. de code Code No/No. de code
piece piece code piece piece code
Sicherungsring
39 Circlip 22x1.75 22x1.75 22x1.75
Circlip exterieur
Sicherungsring
40 Circlip 30x1.2 30x1.2 30x1.2
Circlip exteriuer

Mutter
42 Nut M10 M10 M10
Ecrou
Wellenmutter
43 Nut KM16 KM22 KM22
Vis darbre
Sicherungsring
44 Circlip 18x1.5 22x1.75 22x1.75
Circlip interieure
Vkl.-Gegenflansch
45 Counter flange WN165 WN165 WN165
Contre bride

Vtk.-Gegenflansh
47 Counter flange WN165 WN165 WN165
Contre bride

Befest'gungsbuegel
50 Fastining bow 4-25189 4-25189 4-25189
Serre - joint
Diffemzdruck anzeiger
Diff.Pressure indicator
51 4.36.2 4.36.2 4.36.2
Indicateur de press a
contact_____________
Ableitblech
Plate 4-23487 4-23487 4-23487
Tole
52 Isolierplatte
Isolation plate 4-23802 4-23802 4-23802
Plaque isolante
Ventil
EVW-111-G EVW-111-G EWV-111-G
Valve
Soupape 60-1/4 B-00 60-1/4 B-00 60-1/4 B-00
Spule
53 Coil E0X-220/60 HO E0X-220/60 HO EOX-220/60 HO
Bobine
Kuppulngsdose
Coupler socket FORM B PG9 FORM B PG9 FORM B PG9
Scole de prise de coup
Sohalldaempfer
54 Sounde absorber PSS 14 PSS 14 PSS 14
Siiencieux
Klemmkasten
55 Terminal box 3-23533 K4 3-23533 K4 3-23533 K4
Boites de bornes
Reihenklemme
Binding screw
8 WA 1011-1DG 8 WA 1011-1DG 8 WA 1011-1DG
56 11
11 11
Bomes
INSTRUCTION MANUAL 103(116)
Document Id: IMW623C

Bezeihung DN32 DN40 DN50 DN


designation Stick Identnummer Stick Identnummer Stick Identnummer Stick Identnummer
desgination Code No/No. de code parts Code No/No. de code

AURA
JP 1
— ^MABIIME

Pos
Nr. parts parts Code No/No. de parts Code No/No. de
piece piece code piece ______code______
Schraube
57 Bolt M4X10 M4x10 M4x10
Vis
Tragscheine
58 Assembly rail 5ST1141 5 ST 1141 5ST 1141
Raille portuer
Endwinkel
End angle
59 8 WA 1805 8 WA 1805 8 WA 1805
Nappe du batteur
finsseur__________
Kabelverschraubunq
Cable screwing
2 PG9 PG9 PG9
4 PG11 PG11 PG11
Doullonnaqe
60 Erweiterungs
verschraubunq
Screwing PG 9-PG 11 PG 9-PG 11 PG 9-PG 11
Raccord reducter

Kabelsatz
62 0.5 0.5
Cable BIH FP/L3x1.5 0.5m BIH FP/L3x1.5 BIH FP/L3x1.5
Cable
m m
Kugelhahn
412 07.13 412 07.13 412 07.13
63 Globe valve
G1/4 G1/4 G1/4
Robinet a bille
Verschraubunq
64 Screwing DL 8 G1/4 DL 8 G1/4 DL 8 G1/4
Raccord a vis
Verschraubunq
65 Screwing ALL 6 M10x1 ALL 6 M10x1 ALL 6 M10x1
Raccord a vis
Verschraubunq
1090613 1090613 1090613
66 Screwing
Raccord a vis
G 1/4 G 1/4 G 1/4
Verschraubunq
1050613 1050613 1050613
67 Screwing
Raccord a vis
G 1/4 G 1/4 G 1/4
Verschraubunq
68 Screwing GL 8 G1/4 GL 8 G1/4 GL 8 G1/4
Raccord a vis

72 Roqrleitunqssatz
Pipe Z35561 Z35561 Z35561
Tube

spare part list Ersatzteilliste 6.23 list des parts de rechange


04.01.94 Boll & Kirch filterfaay GmbH Z25415 BL.5(5)

75 Typenscld
Name plate WN265.3 WN265.3 WN265.3
Etiquette

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
AURA
=. MAFH1ME

Bei einer Erzatzteilbestellung beneitigen wirfolgende When ordering for spares we need following 6) DN:_
Angaben: informations 1 )Order
1 )Auftr.-nr___________________________________ no:______________________________
2VTVD: 6.23.1____________________________________ 2)____________________________________T
3)__________________________________________ ype:__________________________________
Erzatzteilzeichnung:___________________________ 3)____________________________________S
4.Pos.Nr:____________________________________ pare parts drawing no:____________________
4)Pos.no:______________________________
7)ldentnummen_ 5)Designation:__________________________ 7)No de code:_
6)DN:_________________________________
7):Code
Bezeihung DN32 no: DN40 DN50 DN
Pos designation Stick Identnummer Stick Identnummer Stick Identnummer Stick Identnummer
Nr. parts parts parts parts
desgination Code No/No. de code Code No/No. de code
piece piece Code No/No. de code piece piece Code No/No. de code
Filterautomat
1 Automatic filter 1 6.23 DN32 1 6.23 DN40 1 6.23 DN50
Filtre a pression autom.

Hahnqehaeuse
100 Housing 1 3-25133 1 2-25524 1 2-25524
Corps
Kueken
101 Cock 1 4-25268 1 3-25530 1 3-25530
Boisseau

Deckel
103 Cover 1 4-25278 1 3-25530 1 3-25530
Couvercle
Hahnsschluessel
104 Cock handel 1 4-8635 1 4-8635 1 4-8635
Clef du robinet
Gehaeuse
105 Housing 1 2-25036 1 2-25532 1 2-25532
Corps
Deckel
106 Cover 1 3-25161 1 3-25161 1 3-52161
Couvercle

Pussierter filtereinsatz
Filter element 4-25543 4-25543 4-25543
108 1 1 1
Filtre de rechanqe
11844 11843 11843

Dichtunq
110 Gasket 1 2-220 1 2-226 1 2-226
Joint
Dichtunq
111 Gasket 1 2-247 1 2-247 1 2-247
Joint

113 Dichtinq
Gasket 1 J-330-7-R-T 1 J-330-7-R-T 1 J-330-7-R-T
Joint

114 Dichtunq
Gasket 2 2-231 2 2-231 2 2-231
Joint
Spare parts list Ersatzteilliste 6.23.1 list des parts de rechange

5) Bezeihnung:_____________________________
Lors d'une commande de pieces rechange les indications 3) Plan des pieces de rechange No:_
suivant sant n^cessaires 4) Pos:______________________
1) No de commande:___________ 5) D6signation:________________
2) Type:_____________________ 6) DN:_
07.05.96 Boll&Kirch filterbau GmbH Z25238 BL.2(4)
AURA INSTRUCTION MANUAL 107(116)
^.MARINE Document Id: IMW623C

Bezeihung DN32 DN40 DN50 DN


Pos designation Stick Identnummer Stick Identnummer Stick Identnummer Stick Identnummer
Nr. Code No/No. de code Code No/No. de code
parts parts parts parts
desgination piece piece Code No/No. de code piece piece Code No/No. de code
Dichtung
115 Gasket 1 A 13x18x1.5 1 A 13x18x1.5 1 A 13x18x1.5
Joint
Dichtung
116 Gasket 1 A 33x39x2 1 A 33x39x2 1 A 33x39x2
Joint
Dichtunq
117 Gasket 4 50x67x1.5 4 78x94x1.5 4 78x94x1.5
Joint

Schnellbefestiger
120 Quick-fixing-device 1 18SXN 26 1 18SXN 26 1 18SXN26
Fixation

Schraube
122 Bolt 2 M10x20 2 M12x30 2 M12x30
Joint
Schraube
123 Bolt 6 M10x25 6 M12x30 6 M12x30
Vis
Verschlusschraube
124 Bolt 2 G 1/4 2 G 1/4 2 G 1/4
Vis
Schraube
125 Bolt 16 M10x30 16 M12x30 16 M12x30
Vis
Schraube
126 Bolt 8 M10x30 8 M12x30 8 M12x30
Vis

$
Mutter
130 Nut 16 M10 16 M12 16 M12
Ecraou

Enttueftungssohraube
132 Bolt 1 4-25002 1 4-25002 1 4-25002
Vis
Schraube
133 Bolt 1 G1 1 G1 1 G1
Vis

Sicherrungsblech
135 Lockinq plate 1 4-25246 1 4-25246 1 4-25246
Tole de surete

07.05.96 Boll&Kirch filteraubau GmbH Z25238 BL 3(4)

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
AURA
^—^MAnilNJE

Pos
Nr. parts Code No/No. de code parts piece Code No/No. de parts parts Code No/No. de
piece code piece piece ______code______
Dichtung
136 Joint
Gasket 2-115 2-115 2-115
Schild
137 Label 4-25279 4-26264 4-26264

Etiquette
AURA
MAR1IME
AURA INSTRUCTION MANUAL 110(116)
= MARINE Document Id: IMW623C

29.4 Proof-list "BOLL CLEAN 2000" cleaning-concentrate

For a continuous soaking time of 8 days, at a mixture of BOLL CLEAN 1: 2,5 water at
a temperature of 25°C no damage was found on the BOLL & KIRCH products listed
here:

BOLL & KIRCH Boll Clean 2000 Limitations


Perbunan gaskets Constant None

Viton gaskets Constant None

Polyester meshes Constant


Soaking-time: Not over 24 hrs.

Constant
Plug-in candle w. stainless- Soaking-time: Not over 24 hrs.
steel mesh
Constant
Screw-in candle w. Soaking-time: Not over 24 hrs.
stainless-steel mesh
Constant
Teflonized filterelement for
filters 6.20 series and
Soaking-time: Not over 24 hrs.
teflonized multimantle
elements

Stainless-steel filter-discs for


filters 6.23/6.24 series Constant None

BOLL & KIRCH cannot accept any guarantee claims for damage to their products
caused by the use of other cleaning materials.

Further information about BOLL CLEAN 2000, see attached "Technical information".

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
29.5 Technical information

BOLL CLEAN 2000 solent-free cold cleaning agent

29.5.1 Prodcut profile

BOLL CLEAN 2000 is a liquid cleaning and degreasing agent with a broad spectrum of
applications. It can be used for virtually all cleaning and degreasing purposes.

BOLL CLEAN 2000 can be mixed with any type of water including seawater. BOLL CLEAN
2000 cleans quickly and thoroughly and is extremely economical. Even at concentrations
of 1 part in 50 parts water, it offers good cleaning and degreasing properties.

The use of BOLL CLEAN 2000 does not require any safety measures.
BOLL CLEAN 2000 offers all these outstanding characteristics without the disadvantages
of solvent-based cleaner.

BOLL CLEAN 2000 is


not combustible
not subject to identification marking regulations
without unpleasant smell not chemically
aggressive physiologically safe biologically
decomposable Umweltbundesamt Reg.-Nr.
04860019

BOLL CLEAN 2000 can be stored at low or high temperatures and will recover its
functional properties after is has returned to normal temperature.

29.5.2 Range of applications

BOLL CLEAN 2000 is suitable for cleaning and degreasing metals, plastics, firmly ^
adhering paint finishes and similar surfaces. It removes oil, wax, grease, soot and a large
of number of other deposits.

BOLL CLEAN 2000 is used in the car industry, in shipping, in the oil industry (for drilling
equipment), in the food and beverages industries, in the metal-working industry, in
reconditioning and mechanical engineering workshops, for diesel and electric locomotives,
for cleaning generators in power stations, and for many other purposes.

29.5.3 Heavy fuel oil sludged meshes

Have to be soaked in a standard solvent. After soaking, the filter elements are cleaned by
using the BOLL & KIRCH Cleaning Unit Type 5.04 in connection with BOLL CLEAN 2000.
•= MAHIME

29.6 Instructions for use

The use of BOLL CLEAN 2000 is not tied to any specific cleaning method. BOLL CLEAN
2000 can be used in a dip bath, a spraying system or a steam cleaner, or it can be applied
manually with a cloth, a brush or a sponge. It can be used cold or warm.

BOLL CLEAN 2000 can be mixed with water including seawater.


Concentration for cleaning filter mesh: 1:2,5 Temperature: up to 60 degree C max.

The concentration depends on the nature and the thickness of the deposits to be removed.
When used in concentrations from 1:30 onwards, no subsequent rinsing is required. No

A
visible film will remain on the surface.

Problems In heavy fuel oil systems of marine diesel engines and measures for
improvement.

Today's heavy fuels are produced by blending distillates with residual oils from the cat-
cracking and visbreaking processes. These fuels themselves increasingly bring about
problems in the fuel booster systems of diesel engines.

Apart from gas formation, which leads to faults in the injection system, macromolecular
hydrocarbons (the so-called asphaltolenes) are deposited on rotors, in viscomats and on
fine filter-meshes.

Particularly in automatic filters, where heavy fuel must pass through very fine filter-
elements to protect the injection pumps, the micronic CrNi-steel filter-meshes can
ultimately become clogged despite frequent and intensive self-cleaning by back- flushing.

The solids deposited on the filter-meshes and on the clean side consist largely of
hydrocarbons. These cannot be removed by any of the commercially available solvents
and even attempts at ultrasonic cleaning allied to well-proven chemicals are often no more
successful.

Thorough investigations carried out by BOLL & KIRCH Filterbau in co-operation with the
Research Institute Bergbauforschung GmbH at Essen in West-Germany, have shown that
this phenomenon occurs mainly with aromatic heavy oils, originating from the cat-cracker
or visbreaker processes and therefore particularly rich in unsaturated carbon atoms.

The comulative effect of oxygen, water, the shear-forces acting on the oil, all allied to
temperatures ranging from 110°C to 150°C, causes crystalline liquids to form in the heavy
fuel, which combine as macromolecular - i.e. carbon-rich - molecular chains, resulting in
sticky deposits and consequent risk of clogged filter-elements as described.
AUR INSTRUCTION MANUAL 113(116)
Document Id: IMW623C
A
MARIN
Studies undertaken onboard ships have revealed a significantly increased proportion of
E
quinoline-insoluble solids in the heavy fuels of the booster system.

Oil companies have left no doubt that an improvement in quality of heavy fuel oil is not to
be expected.

Engine-builders and their licensees are already aware that changes in their systems must
be introduced to cope with present-day conditions. Some have already changed their
booster system from pressure-free mixing tube operation to running at a pressure of 4
bars. This prevents evaporation both of the volatile components and water and eliminates
complications in the injection system.

The reduction of the overcapacity of the fuel booster-pump to the value needed for filling
the injection pump itself has a positive effect on the fuel. The formation of macromolecular
hydrocarbons (asphaltolenes) is reduced, which in turn is beneficial throughout the booster
system.

BOLL & KIRCH have developed their filters to accommodate fuel oil system adaptations
necessary in handling today's fuels.

1 .Large filtration free-areas combined with a preset timing of self-cleaning intervals,


largely prevent over-loading of the filtermeshes with asphaltenes, and avoids 'clogging'.
The preset timing of BOLL automatic fuel filters works in parallel with -but will not over-ride
- the filter's own BOLL Differential-Pressure Indicator. When contamination of the filter-
meshes, by increased differential-pressure initiates back- flushing -in such circumstances
the Differential-Pressure Indicator will over-ride the preset timing but it free to continue its
timed cycle undisturbed.

2.To meet heavy fuel flow rate requirements and relevant filtration specifications,
BOLL can offer various types of automatic filters. Some of these utilise compressed air for
self-cleaning purposes; on this type of filter especially, BOLL's new developments have
considerably reduced the fuel quantities required per each backfiush and this makes
possible a reduction in the size of the fuel feeder- and circulating pumps. 'W'
BOLL automatic filters can still be incorporated in the engine's fuel oil booster system.

Where the mixing tube is run under pressure, a feeder system with pump becomes
necessary between the daily supply tank and the mixing tube. The BOLL automatic filter
may then be installed in the feeder system upstream of the fuel meter, provided that the at-
filter working viscosity does not exceed 120 mPas.

The BOLL duplex discharge filter installed directly upstream of the injection pump has the
safety function of keeping those solids, which can become detached, from pipework,
preheaters, etc., safely away from the injection system. This filter should be as coarse as
possible and have large filtration areas.

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
INSTRUCTION MANUAL 114(116)
AMARINE Document Id: IMW623C

Many heavy fuel installations nowadays create problems because when originally fitted
they did not embody the improvements mentioned in the foregoing: but above all because
design of the separators then installed disallowed subsequent development to meet the
demands of today's heavy fuels; or are not now operated to achieve optimum efficiency.

Apart from the asphaltenes produced in the booster system, the solids, which have not
been removed by the separators, very often cause excessive dirt-loading on the fuel filters
and this results in unduly short self-cleaning intervals, or of change-over times in the case
of manual filters.

Retrofitting of a BOLL Filtrator installed downstream and in services with the separator(s)
results in a two-stage process, at once involving both separation and filtration. By this
means, all harmful solids are removed together with water, and the problems in the booster
system are solved.

An additional benefit is a great reduction of wear-rates on cylinderliners and piston rings.

AURAMARINE LTD P.O.BOX 849 Tel + 358 204 86 5030


FIN-20101 Fax + 358 204 86
TURKU 5031
AURA
~ ^ L MARIIME

30 HOW TO ORDER SPARE PARTS

Identification of needed part

When ordering spare parts, please mention the following:

1 Serial number of the unit


(welded on the bottom beam of the unit frame)

1234

2 Part number from the part list


PARTNO ]

► E17011
E17033

E17070

3 Serial number of the part to be replaced


(mentioned in the rating plate of the part)

Ordering address:

Auramarine Ltd., After Sales Dept., P.O. Box 849, FIN-20101 TURKU Fax
+358 204 86 5031 Tel +358 204 86 5030

In case of guarantee part(s), please return the damaged part(s) to the above
mentioned address.

31 SERVICE TABLE
EQUIPMENT SERVICE HOURS

ACE screw pumps see pages 35, 36


ACG screw pumps see pages 51
EH heaters see page 78
EO heaters see page 80
MX heaters see page 85
Auto filter €.61. see page 96-101