L E G E N D GENERAL NOTES MATERIAL SPECIFICATIONS

SYMBOL DESCRIPTION ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED


DRAINAGE LINES ALL INSIDE DRAINAGE LINES SHOULD BE
ACCORDING TO THE PHILIPPINE PLUMBING CODE. THE NATIONAL
SV SEPTIC VAULT NELTEX PIPES SERIES 1000, CLASS 35 OR
BUILDING CODE AND THE RULES AND REGULATION OF LOCAL
APPROVED EQUAL.
CO 100 MM THK. CHB WALL GOVERNMENT AUTHORITIES CONCERNED.
600x600 BLOCKOUT
ALL OUTSIDE DRAINAGE LINES SHALL BE
CB CATCH BASIN COORDINATE THE DRAWING WITH THE OTHER RELATED DRAWINGS AND
CONCRETE DRAINAGE PIPE (CDP) FROM NON TRAFFIC GRATE TRAFFIC GRATE 1
SPECIFICATIONS. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF 2" RAISED
150MMØ TO 250MMØ AND FROM FLR. LN. FLANGE
S SINK ANY DISCREPANCY FOUND THEREIN. POLISHED
300MMØ AND LARGER SHALL BE
CHROME FIN.
WC
REINFORCED CONCRETE PIPE (RCP). 1-1/2" VENT
WATER CLOSET ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY (MIN. IN WALL)
RELOCATIONS REQUIRED FOR PROPER EXECUTIONS OF OTHER TRADES FLASHING FULL GRATE WALL REF
FD FLOOR DRAIN SEWER/WASTE & VENTPOLYVINYL CHLORIDE (PVC) PIPE SERIES CLAMP UNLESS 2"x1-1/4"
SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER. ARCH
1000 AND CLASS 35 SIMILAR TO OTHERWISE 1-1/4" (LAV &EDFS)
(FOR LAVS & EDFS)
DRAIN
EMERALD BRAND OR APPROVED EQUAL. SCHEDULED 2"x1-1/2"
LAV LAVATORY BODY 1-1/2" (SINKS & EW)
PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL DOME OR SPECIFIED (FOR SINKS & EYEWASH)
POLISHED CHROME
LOCATION DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND 2"x3" REDUCER STRAINER SANITARY TAPPED TEE
DS DOWNSPOUT CHEMICAL WASTE CAST IRON (C.I.) PIPE SIMILAR TO ASA PLATED P-TRAP
STRUCTURES AS VERIFIED BY THE CONTRACTOR. REQ. FOR ALL 2" WASTE
BRAND OR APPROVED EQUAL. FLR. SINK
FLR. SINKS FOR (MIN. IN WALL)
OUTLET
F FAUCET COMBINATION POLISHED
ALL SLOPES FOR HORIZONTAL DRAINAGES SHALL MAINTAIN 2% UNLESS (2" MIN)
COLD/RAIN RISER GALVANIZED IRON (G.I.) PIPE SCHEDULE WASTE & VENT POLISHED CHROME
LT LAUNDRY TRAY OTHERWISE SPECIFIED. SYSTEM CHROME PLATED PLATED CAST
40 SIMILAR TO APO / SUPREME NO HUB BRASS NIPPLE
CLAMP (TYP) BRASS w/
DOWNFEED/SUCTION OR APPROVED 3" WASTE
SET SCREW
WL WATER LINE SIZES OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE MIN
EQUIVALENT.
WITH THE MANUFACTURERS INSTRUCTIONS.
SL

MGV
SEWER LINE
THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND
COLD/RAIN WATER POLYPROTHELENE PIPE PN-20 SIMILAR
TO BUGATTI OR EQUAL.
5 FLOOR SINK DET. 6 DRAIN PIPE DET.
MAIN GATE VALVE COORDINATES THE WORKS WITH THE SEWER LINE EFFLUENT DISPOSSAL 6 SCALE 1:20M. 6 SCALE 1:20M.
POINT AND WATERLINE SERVICE CONNECTING POINT.
GV GATE VALVE HOT WATER LINE POLYPROPHELENE PIPE PN-20 SIMILAR
TO BUGATTI OR EQUAL RATED AT
ALL PIPES SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN
WM WATER METER MINIMUM PRESSURE.
METERS UNLESS OTHERWISE SPECIFIED.
SSK SLOP SINK FLOOR DRAINS MANUFACTURED BY METMA BRAND OR
APPROVED EQUAL.

AIRCON DRAINS EMERALD PIPE W/ 25MMØ THK. RUBBER


INSULATION.

CLEANOUT &
ACCESS COVER.
1 2 1 2 1 2 TOP OF COVER
FLR. LN. TO BE FLUSH w/
TOP OF THE FLOOR
4.00 4.00 4.00

1.30 2.70 1.30 0.73 1.98 1.30 0.73 1.98

LOT 37 BLK 5 LOT 37 BLK 5 LOT 37 BLK 5 BALANCE OF


1
PIPING SAME
8" C.I. AS CLEANOUT
1 N 81°40' E = 4.00M. 1 N 81°40' E = 4.00M. 1 N 81°40' E = 4.00M. BEND
D SS
CB CB
2 D SS 2 D VSTR 2
TO GRADE

1.00
FD SERVICE FD 4"Ø DS 4"Ø DS
1.60

AREA
FLOOR CLEANOUT (FCO)
2.10

2.10
WC WC
BEDRM. CLEANOUT NOT TO BE LOCATED AT CARPETED AREA
LAV LAV
CO

5.00

5.00
KIT. DN

3.74
SK

C C 2.70 C
7.00

7.00

DINING
AREA BRASS CLEANOUT
4.35

5.40

PLUG w/ COUNTER FINISHED


SUNK HEAD GRADE
10.00

10.00

10.00

10.00
N 8°20 W = 12.00M.

N 8°20 W = 12.00M.

N 8°20 W = 12.00M.
S 8°20' E = 12.00M.

S 8°20' E = 12.00M.

S 8°20' E = 12.00M.
LIVING
AREA BEDRM.

0.15
LOT 16 BLK 5 LOT 38 BLK 5 LOT 16 BLK 5 LOT 38 BLK 5 LOT 16 BLK 5 LOT 38 BLK 5
12.00

12.00

12.00

12.00

12.00

12.00
UP

2.63
B B B
0.55

3.85

16" SQ.CONC.

5.00

5.00
PAD TROWEL
BEDRM. SMOOTH &
EDGE
SV

2.63
1
1
BEND IF 8 " C.I. BEND
8
CLEANOUT
1.35

A A A
5.00

5.00

CB CARPORT CB OCCURS @ C.I. WASTE LN


DEN END OF LN. LENGHT TO
4"Ø DS 4"Ø DS SUIT WASTE
TO MAIN
TO MAIN LN.
STREET
2.00

2.00

2.00

2.00
SEWER LN. DRAINAGE
LN.
4 3 4 3 4 3
S 81°40' W = 4.00M. S 81°40' W = 4.00M. S 81°40' W = 4.00M.

ROAD LOT 5 ROAD LOT 5 CLEANOUT TO GRADE

4 CLEAN OUT DET.


6 SCALE 1:10M.

1 GROUND FLR. PLUMBING LAYOUT 2 SECOND FLR. PLUMBING LAYOUT 3 DOWNSPOUT LAYOUT
6 SCALE 1:100M. 6 SCALE 1:100M. 6 SCALE 1:100M.

ARCHITECT/ENGINEER PROJECT TITLE PROJECT OWNER SHEET CONTENTS REVISIONS SHEET NO.
DESIGN:

AS SHOWN
ASBUILT PLAN OF CAD: P-1
TWO2)-STOREY RESIDENCE ROSALIA G. YU/TO HENRY J. YU
PRC NO.: PTR NO.:
CHECKED:
2 9
REG. NO.: TIN NO.: PROJECT LOCATION: LOT 37 BLOCK 5 MOSS STREET, METROGREEN ADDRESS:
DATE:
ISSUED ON: ISSUED AT: SUBD,. BRGY. SAN BARTOLOME, QUEZON CITY PROJ. NO.:

You might also like