Cooling fans

Cooling fans
The rig is equipped with two standard fan drives, one for cooling the compressor/hydraulic
oil, and one for cooling the engine water/air inlet. High ambient temperature fan drive for
warmer environment is available as an option.

Conditions for starting the compressor/hydraulic oil temperature cooler fan:

• Compressor temperature sensor B366 => PLC input X16-7


OR
• Hydraulic oil temperature sensor B362 => PLC input X16-3
Results in:
• PLC output X16-9 => Y504 activated

Conditions for starting the engine water/ATAC temperature cooler fan:

• Engine coolant temperature sensor B354 (CAT system)


OR
• Air inlet temperature(CAT system)
Results in:
• PLC output X17-4 => Y501 activated

The signal input to solenoids Y504 and Y501 varies between 50mA – 510mA depending on
the cooling demands.
Revolution

max Rig type Full rpm at


L7 95 °C
L8 120 °C

0 mA
50 510