Comfort Room

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

2

A-4

1.375
REINFORCEMENT CONCRETE
100mm. x 100mm. FLOOR BEAM, PLAIN CEMENT
DRAIN STRAINER DOOR JAMB
PLASTERED FINISH

TOP OF BEAM TOP OF BEAM INTERIOR T & B SIDE


SHOWER SHOWER HEAD

0.40
FAUCET DOOR

DEPRESSION
0.70

CONCRETE

0.025m.
TOPPING
150mm. THK. CHB CERAMIC TILE FINISH
FIREWALL PLAIN CEMENT

0.30

0.05 0.006
3 PLASTERED FINISH
100mm. THK. CHB
A-4 FIREWALL PLAIN CEMENT
FLOOR MOUNT PLASTERED FINISH TILE ADHESIVE
PAIL FLUSH BOWL SHOWER FAUCET
+0.15m.
TILE
F.F.L. 0.46 SLOPE

0.60
0.43
SET-OUT
2.00

300mm. x 300mm. UNGLAZED


VITRIFIED CERAMIC
0.36

FLOOR TILES CONCRETE TOPPING


WALL-HUNG
2 % SLOPE

LAVATORY
1.23

FLOOR MOUNT

0.50
PAIL FLUSH BOWL
THRESHOLD AND
300mm. x 300mm. 4 WATER GUARD DETAIL
0.415

UNGLAZED VITRIFIED
CERAMIC FLOOR TILES A-4 SCALE : 1 : 5 MTS.

0.30

1.20
300mm. x 300mm.
UNGLAZED VITRIFIED

0.90
CERAMIC FLOOR TILES CONCRETE
WALL-HUNG
LAVATORY TOPPING CERAMIC TILE FINISH

0.60
TILE ADHESIVE

0.36

0.36
0.32

0.025
UNIT FLOOR LINE

0.05
UNIT FLOOR LINE
T & B FLOOR LINE
T & B FLOOR LINE

0.40 0.30 0.43 0.50 0.30


GRAVEL BEDDING
5 FLOOR MOUNT
PAIL FLUSH BOWL
A-4
1 PLAN OF TOILET
A-4 SCALE : 1 : 20 MTS.
2 SECTION-1 OF TOILET 3 SECTION-2 OF TOILET 5 DETAIL - 1
A-4 SCALE : 1 : 5 MTS.
A-4 SCALE : 1 : 20 MTS. A-4 SCALE : 1 : 20 MTS.

TOP OF BEAM TOP OF BEAM

PLAIN HOSE BIBB


1.20 SINGLE BOWL STAINLESS
STEEL KITCHEN SINK PLAIN HOSE BIBB
0.80 0.40
DISTANCE OF FAUCET
TO COUNTER EDGE 10mm. O/ RSB 300mm. x 300mm. GLAZED 300mm. x 300mm. GLAZED
VITRIFIED CERAMIC TILES VITRIFIED CERAMIC TILES

2-10mm. O/ RSB

SINGLE BOWL STAINLESS


0.60

0.50

STEEL KITCHEN SINK


300mm. x 300mm. GLAZED
VITRIFIED CERAMIC SINGLE BOWL STAINLESS
FLOOR TILES STEEL KITCHEN SINK

0.60
3-10mm. O/ RSB
EQUALLY SPACED
AS SHOWN
300mm. x 300mm. GLAZED
VITRIFIED CERAMIC TILES
6 P L A N 75mm. REINFORCED CONCRETE
COUNTER W/ 10mm. RSB
0.85

A-4 SCALE : 1 : 20 MTS.

UNIT FLOOR LINE UNIT FLOOR LINE

100mm. THK. CHB COUNTER


SUPPORT PLAIN CEMENT
PLASTERED FINISH
8 S E C T I O N
A-4 SCALE : 1 : 20 MTS.

7 ELEVATION
A-4 SCALE : 1 : 20 MTS.

PROJECT TITLE : Republic of the Philippines ARCHITECT / ENGINEER DESIGNED: HTTRD CHECKED: RGRAMOS SHEET NO.
MUNICIPALITY OF TIGAON Office of the President
Province of Camarines Sur DRAWN: PLIBARDALOZA DATE:
NATIONAL HOUSING AUTHORITY
CHECKED BY RECOMMENDING APPROVAL SHEET CONTENT

REVIEWED BY A-4
TIGAON RESETTLEMENT PROJECT P1 T & B DETAILS, TYPHOON
SHUTTER DETAILS

DESIGNATION
APPROVED BY REVISIONS DATE:

LOCATION : Engr. CRISTINA A. CABANGON Engr. ALBERT A. PERFECTO MARCELINO P. ESCALADA JR. 4 12
REG No.: DATE:
BRGY. SALVACION, TIGAON, CAMARINES SUR DISTRICT MNGR DISTRICT II - REGION V REGIONAL MANAGER REGION V GENERAL MANAGER, NHA
MUNICIPAL MAYOR PTR No.: PLACE: