A B C D E GENERAL NOTES:

1. ALL ELECTRONICS WORK AND INSTALLATIONS SHALL BE DONE IN


ACCORDANCE WITH TIA STANDARDS, THE PROVISIONS OF THE LATEST
EDITION OF THE PHILIPPINE ELECTRONICS CODE AS PER R.A. 9292, THE
- Addressable Fire Alarm Panel (Numens 6002-01)
The 6002 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm system. The 6002 is compatible with
4.01m 4.00m 4.00m 4.00m RULES AND REGULATIONS OF THE LOCAL MUNICIPALITY AND THE
TELECOMMUNICATIONS COMPANY.
Numens addressable devices and supports both Numens SP and TP loop protocols. Either 125 or 250 devices per loop are supported. Non-addressable
devices can also be connected to the 6002, when used with addressable input modules. The 6002 comes standard with 2-loops, and is expandable up to
24-loops. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile cause-and-effect PC-based
2. ALL NON-CURRENT CARRYING ELECTRICAL EQUIPMENT PARTS SHALL BE programming tool enables rapid customization with software for sites that require special operating features.
PROPERLY GROUNDED.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 The 6002 control panel provides fire detection and alarm system designers with a premium product for life safety and property protection applications.
Smoke Detector (Numens SNA-360-SA)
3. PULL BOXES, JUNCTION BOX AND OR DISTRIBUTION BOX WILL BE
PROVIDED EVEN THOUGH NOT REFLECTED IN THE PLAN. SNA-360 analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors suitable for connection to Numens 2-wire
addressable fire detection control and indicating equipment. Up to 125 detectors can be connected to each alarm zone loop. Advanced electronics in conjunction
4. ALL CHANGES IN ALLOCATION AND SPECIFICATION OF NODES AND with a photoelectric smoke sensing chamber provides early detection of fire and high immunity against unwanted alarms. The SNA-360 analogue addressable
PROPOSED STRUCTURE WILL BE SUBJECTED FOR PRIOR APPROVAL OF detector range provides fire detection and alarm system designers with a premium smoke detector for life safety and property protection applications.
CHANGE ORDER AND WILL BE REFLECTED IN AS-BUILT PLANS.
Manual Call Points (Numens 660-001)
5. ALL PATCH CHORDS, PATCH PANEL AND OTHER OUTLETS SHALL BE 660 manual call points connect to addressable fire detection control and indicating equipment. Up to 125 devices can be connected to each alarm zone loop
PROPERLY LABELED AND SHALL FOLLOW EIA/TIA STANDARDS. using the addressable loop communications protocol.
A pressure-activated displacement element provides a safe and convenient way for building occupants to manually initiate a fire alarm condition. All models
6. THE LENGTH OF EACH INDIVIDUAL RUN OF HORIZONTAL CABLE FROM have an integral alarm indicator that illuminates when the manual call point has been activated. The indicator can also be configured to flash when polled by
THE PATCH PANEL TO THE INFORMATION OUTLET SHALL NOT EXCEED 90 the fire detection control and indicating equipment.

1
METERS AND SHALL NOT CONTAIN SPLICES OR JOINTS. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the operating face to the quiescent position. The
660 manual call point range provides fire detection and alarm system designers with a Standards-compliant, premium product for life safety and property
7. ALL ELECTRONIC MATERIALS AND DEVICES TO BE USED HEREIN MUST
BE BRAND NEW AND OF APPROVED TYPE FOR THE LOCATION AND protection applications.
PURPOSE. addressable audio/visual alarm (Numens 640-004)
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection and alarm systems.
8. ALL WIRES ARE TO BE ENCLOSED IN CABLE DUCT. 640 is loop-powered. Activation is initiated either by a dedicated initiation message from the control and indicating equipment or optionally when the
control and indicating equipment enters the Alarm Condition. Up to 32 devices can be connected to each alarm zone loop.
9. TELEPHONE LINES MUST BE SEPARATED AT LEAST 12 INCHES FROM ANY The 640 range of addressable audio/visual alarm devices provide fire detection and alarm system designers with a premium product for life safety
ELECTRICAL LINE. applications.
10. THE MODEM, ROUTER, LAN SWITCH, SERVER AND PBX ARE LOCATED /
MALE RM.-1MALE RM.-2 MALE RM.-1
MALE RM.-2 ENCLOSED INSIDE A DATA CABINET. LEGEND
3.50m SD - ADDRESSABLE SMOKE
11. ALL WORK AND INSTALLATIONS TO BE UNDERTAKEN HEREIN SHALL BE
UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ELECTRONICS
ENGINEER (PECE).
DETECTOR
SD SD SD SD CP - ADDRESSABLE MANUAL
SPECIFICATIONS
1. THIS DRAWING IS A SCHEMATIC REPRESENTATION OF SYSTEM ONLY.TENDERS TO
CALL POINT
DETAIL COMPLAINT OFFER BASED ON MANUFACTURER'S SYSTEM & WIRING METHODS SH - ADDRESSABLE VISUAL & AUDIO ALARM

2
RECOMMENDATION.
2. WIRING INSTALLATION (CEILING CONCEALED, EMBEDDED, EXPOSED OR SURFACED) FACP - FIRE ALARM CONTROL PANEL
SHALL USE PVC, 20MMØ MINIMUM.
A. FIRE ALARM CABLE - TF WIRE #16 or EQUIVALENT. RP - REPEATER PANEL
up SECOND FLOOR
LOOP 8 ZONE 7
SD
SD
SD
RECEIVING RECEIVING SH SD SD SD SD SD SD SH SD SD SD SD SD
3.50m 17 DN. AREA AREA DN. 17
16 16
15 PANTRY PANTRY 15 CP CP SECOND FLOOR
14 14 LOOP 7 ZONE 6
13 SH SH 13
12 CP CP 12
SH SD SD SD SD SD SH SD SD SD SD SD
3 11
10
9
11
10
9
8 8
CP CP
7 7 2/F
6 6
GROUND FLOOR
5 5 LOOP 6 ZONE 7
MALE RM.-3 MALE RM.-3
3.50m 4 MALE RM.-4 MALE RM.-4 4
3 SD 3 SH SD SD SD SH SD SD
SD SD
2 SD 2
CP CP GROUND FLOOR RP
LOOP 5 ZONE 5

SH SD SD SD SH SD SD SD

4 CP CP
GROUND FLOOR
LOOP 4 ZONE 4
1 1
SH SD SD SD SD SD SH SD SD SD SD SD SH SD SD SD SD
connect to
FACP CP CP CP

ZONE 7 GROUND FLOOR


ZONE 3
SUPPLY/RECORD & DORMITORY BUILDING SD = 11 LOOP 3

CP = 2 SH SD SD SD SD SD SD SH SD SD SD SD SD SD SH SD SD SD SD SD SD
SH = 2
SECOND FLOOR PLAN CP CP CP
GROUND FLOOR
SCALE 1:100M LOOP 2 ZONE 2

SH SD SD SD SD SD SD SD SD SH SD SD SD SD SD SD SD SD SH SD SD SD SD SD SD SD

CP CP CP
GF
LOWER GROUND FLOOR
LOOP 1 ZONE 1

SH SD SD SD SD SD SD SD

RISER DIAGRAM FACP CP


LG
SCALE NTS
14mm BCW / 20mm Ø COPPER GROUND ROD

PROPOSED PROJECT DRAWN BY CHECKED BY RECOMMENDED BY NOTED BY APPROVED BY SHEET CONTENTS SHEET 5 OF 6
-SUPPLY/RECORD & DORMITORY BUILDING
- SECOND FLOOR PLAN
INSTALLATION OF FIRE DETECTION MERWIN V. LADAC -RISER DIAGRAM
-GENERAL NOTES & SPECIFICATION
AND ALARM SYSTEM AT MALUNGON ENGINEERING ASSISTANT
GERALD G. FACIOL JERRY E. BELBIDER ARVIN C. ALEJANDRO, M.D. STEVE CHIONGBIAN SOLON -LEGEND 5
MUNICIPAL HOSPITAL REVIEWED BY CHIEF, PLANNING DIV. PROVINCIAL ENGINEER PROVINCIAL HEALTH OFFICER PROVINCIAL GOVERNOR
S 6
LOCATION: BRGY. POBLACION, MALUNGON, SARANGANI
ARNOLD P. ASTURIAS
PROVINCE ASST. CHIEF, PLANNING DIV. PROF. ELECTRONICS ENGINEER