Technical Specifications for Materials Used in House Connections Water Distribution Division Field Customer Services Section © 6-1. 10, 12, Water Meter (A) General Any water meter to be used where these Guidelines apply should one of those included in the "Water Meters Approved for Use" list issued by Water Directorate, the latest issue shall apply. To be successfully approved, the water meter must meet the following minimum standard criteria: Water meter must be capable of being used in the approved remote, unattended, electronic, water meter reading system, Meter body shall be totally separate from the meter measuring mechanism. Over tightening of the meter body portions should not affect the meter declared accuracy. All meters must have a built in reading display window of suitable size. A magnification lens could be used to improve the readability of the digits, Reading Display Window shall not be susceptible to condensation and should be protected by a hinged flap or similar. All meter parts must be replaceable. Spare parts must be stocked and be available at all times for both new versions as well as old versions of the meter, Supplier must inform Water Directorate in writing and obtain approval before replacing a meter with a new version and of any modification made on approved meter component parts or connectors / flanges. Alll water meters must read in Cubie Meters. The least digit must not exceed one liter All meters must have a digital reading display window. Fractions of a Cubic ‘meter could be displayed using an analog display system, If a digital system is used to display the fractional part of the meter reading the extreme three right hand digits should be of a color different than the rest of the digits. A multiplication factor - if used - must be only for meter of sizes 11/2" and above. No meter of smaller size is to have a multiplication factor. Multiplication factor must be indicated clearly with bold lettering at location very close to the reading display window. Jefe Sava 14, 15. 16. 17. 18 19, 20. 21. 2. 23. 24. Meter body shall be made of impact resistant plastic, brass or ductile iron. Meters meeting all other criteria listed under this Article but have bodies made of other matter maybe suitable forapprovel and could be examined. ‘Meter numbering system must be approved by the Water Directorate. ‘Meter number - if unprotected - must be engraved on the meter body on the same side as the reading display window. If the meter number is written on the counter face of the meter, it should then be protected by a toughened clear plastic or glass cover. I For all meters, it should be possible to change the reading counter and display window keeping the meter number as it is, In other words, only change of meter body component should force a meter number change. ‘The unit of reading - i.e. Q. Meters-must be displayed within the reading window itself not on meter body, hence, by replacing the counter unit and display window, the unit of reading displayed on the meter must automatically be replaced. Meter external color shall be Light Blue to RAL 5015. For meters with external body coat, the paint coat thickness shall not be less than 100 microns for non-ferrous meters and 300 microns for all other. Meter body must be robust, capable of withstanding prevailing atmospheric temperature range of 5 C to 50 C, a humidity range of upto 100% and a normal minimum running water temperature of 50 C. All working parts of the water meter must be suitable for use with desalinated water at e normal of SO C minimum temperature. Meters must be designed fora working water pressure of 10 bars with surge pressures reaching a maximum of 20 bars. A provision must be made to seal the water meter by joining the body to the counter and hence prevent tampering with the measuring mechanism or meter counter. Sealing should possible using a wire and a lead stamp. If «another system is used for scaling the meter, that system shall be approved by Water Directorate. New meters must be sealed by the manufacturer after passing the quality and accuracy tests. Markings on the meter must include - but not limited to the following : a) Trade name of the meter. b} Meter nominal size. c) Meter nominal flow capacity. d) Water flow direction. ) — Aunique serial number. f) Year of meter manufacture. 2). Unit of measurement, 25. 26. 6.2 Each meter shall be guaranteed by the manufacturer / authorized dealer for a period af,not less than two years from date of sale. Meters handed over to ADDC imist have minimum of one year of the guarantee period left. Complete documentation should be provided to customers for meter orders exceeding hundred meter units of Domestic meters and ten units of Bulk meters. Documentation should be include an operation and maintenance manual in addition to technical specification and general catalog. G.R. P. Water Meter Cabinet Water Meter Cabinet intended for use on House Connections of sizes upto and including one inch diameter, for residential and commercial villas, must be made of press molded fiber glass (G.R-P) material and should fulfill the following requirements: Cabinet to be press molded G.R-P. gray in color for all sides and doors. Cabinet to have a provision for installation recessed in the wall. External cabinet size to be 60 em (11) x 30 em (W) x 30 em (D) such that it is possible to accommodate water meters of size range half an inch upto one inch, in addition toa non-retum valve and a lockable gate valve of corresponding size. Cabinet door to be hinged at the left side and to have two triangular locks Allen Keys - at the upper and lower right corners. On the door should be imposed the cabinet identification "Water Meter - ADDC in both Arabic and English text which should be clear ani large enough. In order to prevent the ingress of water and dust to cabinet interior, cabinet door should be effectively sealed using and elastic sealant of similar method. Two holes each of 1 1/4" diameter should be provided for pipe entry and exit in the cabinet base and roof respectively. Drain outlet and air vents must be provided. Meter view window to be of clear toughened or wire glass of size not less than 10cm (H) x 10 cm (W). View window should be provided with a side hinged cover as for the main door in addition to a single lock Meter view window should face directly the meter reading counter. Locks, hinges and all other metallic parts should be of corrosion resistant material. i. 12. 13. 14, 63 64 Cabinet back side must be strengthened and be provided with suitable supports for securing the water meter and connection pipes. Multi meter cabinet for two or four meters could be used provided the above conditions are met with exception that cabinet width should be increased to accommodate the meters. Center to center spacing of meters should not be less ‘than 17 cm and an edge meter clearance not less than 10 cm from cabinet side. ‘However, the cabinet must be apprived before use. Designs not meeting all of the above criteria could be submitted for review and comment, however such cabinets should not be used before obtaining final approval. New samples of water meter cabinet submitted for review must be complete with all necessary internal fittings - such as water meter & lockable gate valve ~ already installed and secured as if ready for connection. Cabinet must include the following fittings : lockable gate valve and water meter all of a diameter same as that of the proposed House Connection. Polyethylene Hose Polyethylene Hose pipe should conform with B. S. S. 1972/1967 class "C" should be manufactured from a low density compound (polyethylene density may not be greater than 0.93 g/ml (a 20 C). The out side diameter of the pipe should conform to B. S. 1972/1967. However wall thickness should not be less than 0.1 mm pipe shall have marked at interval of one meter, the manufacturer identification, specification number and class "C" by means of adhesive tape or suitable paint or engraved. Polyethylene pipe should be supplied in coils of length 150 meter or 500 feet. If required, supplier should make necessary arrangement for a test pressure of twice the normal working pressure. Sample should be submitted and is subject to approval. Brass Connectors Should be of hot pressed Brass to B. S. S. 218, designed for connecting polyethylene to polyethylene hose pipe to B.S. 1972/1967 class "C" low density polyethylene pipe. Flange insert should be of copper. Manufacturer name, B. S. number along with class should be engraved on each component. Connectors should stand a test pressure of 10 bars and should stand repeated uses for 10 times particularly the rubber compression ring. Connectors should be of European origin. The supply should be accompanied by a manufacturer certificate stating the date of manufacture, specification, name and address of the local agent or representative. ‘Sample should be submitted and is subject to approval. 65 6.6 6.7 Brass Tee Should be of hot pressed Brass to B. S. S. 218, designed for connecting polyethylene Hose pipe to B. S.S. 1972/1967 "C" low density. Flange insert should be of copper. It should stand a test pressure of 18 bars. Manufacturer identification, specification number and class "C" should be engraved on the, body and fittings. ‘Sample should be submitted and is subject to approval. Bronze Gate Valves Valve should be non rising stem solid wedge disc and screwed in bonnet in accordance with B. S. 5154 full way gate valve. Body should be made of cast Bronze to B. S, 1400 LG2 and components conforms to B. $ 2872 CZ 122. Body seats are integral and should be accurately tapered to ensure perfect shut off without strain. The disk should be of wedge pattem. Hollow threaded for non rising stem valve and conform to BS 1400 LG 2. Stem threads should be accurately machined to ensure full thread engagement with the disc or bonnet to B.S. 21 Stuffing box should be packed with quality packing to assure a tight stem seal asbestos with graphic material. Open and shut indicators should be caste on the handle wheel which should provide a safe hand grip. ‘Valve should ‘stand a minimum pressure of 17.5 Bars or 250 Ibs./sq. in (a) 50 c. ‘The company name and patent number should be engraved on the valve. The supply should be accompanied by manufacturer certificate stating the date of manufacture, specification, name and address of the agent or representative. ‘Sample should be submitted and is subject to approval. Male Brass Polyethylene Adapter Adapter should be of hot pressed brass to B. S. S. 218, designed for connecting to B. S, S, 1972/1967 class "C* Low density polyethylene pipe. Flange insert should be of copper. Manufacturer name, B. S. number along with class should be engraved on each component, Adapter should stand test pressure of 10 Bars and should stand repeated uses for 10 times particularly the rubber compression ring. Sample should be submitted and is subject to approval. 69 6.10 Female Brass Polyethylene Adapter Adapter should be of hot pressed brass to B. S. S. 218, designed for connecting to B. S. 8. 1972/1967 class "C" Low density polyethylene pipe. Flange insert should be of copper. Manufacturer name, B.S, number along with class should be engraved on each component, : Adapter should stand a test pressure of 10 Bars and should stand repeated uses for 10 times particularly the rubber compression ring, Sample should be submitted and is subject to approval. Swivel Balancing Brass Ferrules Component should have a stop cock and ferrule combined and shall be of hot pressed brass to B. S. S. 218, with heavy gauge, swivel balancing, screw down type, fitted witha 1/2" square head for closing and opening and shall be designed for connecting with polyethylene pipe to B.S. S, 1972/1967 class "C” low density. Spindle of the ferrule shall be of high tensile magnesia Bronze to B.S. 8. 2874. Manufacturer name and pattern number should be engraved on the ferrule body and should stand repeated uses for 10 times particularly the rubber compression ring. The supply should be accompanied by a manufacturer certificate stating the date of manufacture, specification name and address of the local agen! or representative. Sample should be submitted and is subject to approval. Saddle Strap Component should be of Gun Metal Saddle Strap suitable for use with I. S.O, ductile Iron pipes type (K-9) and No. 2531, with stainless stee! bolts and nuts. The nubber ring should fill in the groove. All straps should have 3” Diameter boss 3/16" Thickness at band 3/3" Thickness at lugs 1132" Thickness boss Gunmetal should conform to B. S. 1400 LG 2. Bolts and nuts should be of stainless steel conforming to BS 6105: 1981 and I. S. 0. 3506 : 1979. 18/8 Grade A2 - 50 stainless steel. 6 6.12 Company name & patent number should be engraved on the body, The supply should zbe accompanied by a manufacturer certificate stating the date of manufacture, specification, name and address of local agent or representative. Sample should be submitted and is subject to approval. Drill Tap Drill taps should be suitable for use with ductile iton water pipes, Combined drill and tap with B.S. P. thread to BS 21, specially hardened, given 2 hardness range of 63 degree Rockwell for Talbot pressure tapping machine and for insertion of swivel balancing ferrule. Drill bit size should be 3/4" standard pattern. Cup drill and taps size 11/2" BSPP-11TPI- for Machine No. 2. ‘Sample should be submitted and is subject to approval. Brass Reducer Bush Should be hot pressed to B. S. S.218, design for connecting polyethylene pipe to B. S. S. 1972/1967 class "C* low density. Flange insert should be of copper. The name of manufacturer, B. S. number and class should be engraved on each component. It should stand a test pressure of 10 bars or more. Sample should be submitted and is subject to approval. END %. pikesu SINGH + Detai plant Gorten 2 4@ GENERAL THE INVERT LEVEL OF THE EXTERNAL, DRAINAGE SYSTEM SHALL BE DETERMINED BY THE CONTRACTOR TAKING INTO CONSIDERATION THE DRAINAGE CONNECTION LEVEL TO CITY SEWER. INVERT LEVELS SHOULD 8 REFERRED IN RELATION TO DM DATUM, FOR ALL AIR WELLS, ACCESS DOORS SHOULD BE PROVIDED AT THE FLOOR WHICH “IS LEVEL WITH BOTTOM OF WELL. FLOOR DRAINS TO’ BE PROVIDED IN ALL GARBAGE ‘ROOMS. DRAINS TO BE PROVIDED ALSO IN ALL TYPICAL FLOOR GARBAGE ROOMS FOR ig BUILDINGS HAVING GARBAGE CHUTES. THE HEADS OF ALL STACKS (VENT) SHALL 8© SHOWN ON THE ROOF LEVEL DRAINAGE DRG. ALSO SHOW THE RAINWATER DRAINAGE LAYOUT ON THE SAME PLAN, INDICATING R.W.O,*S PIPES, SLOPES, RIDGES AND VALLEYS. MINIMUM 75MM DEEP SEAL. | ALL FLOOR DRAINS SHALL HAVE | WINDOW &/C'S SHALL BE PROVIDED WITH GRP TRAYS:HAVING DRAINAGE ARRANGEMENT. FOR ALL COMMERCIAL KITCHENS, HEAVY DUTY GREASE TRAPS MUST BE PROVIDED AS PER DM REGULATIONS. oa 10. ite 12. 13, 14, 15. 16. O40 WHERE MANHOLES/ INSPECTION CHAMBERS/SEPTIC TANKS ARE TO BE BUILT IN HIGH SUB-SOIL WATER CONDITIONS COMPLETE CONSTRUCTION SHALL BE IN WATER PROOFED RCC OR IN’ GRP. IF INSPECTION CHAMBERS/MANHOLES, ARE IN AGRICULTURAL LANO, THE COVER OF MANHOLE SHOULD BE RAISED 75MM ABOVE THE NATURAL GROUND LEVEL. DIAMETER OF SEMI-CIRCULAR CHANNEL IN THE BOTTOM OF MANHOLE SHALL BE EQUAL TO THE INCOMING SEWER DIA. THE SIDES OF CHANNELS IN MANHOLE SHALL BE EXTENDED VERTICALLY TO THE SANE LEVEL AS THE CROWN OF THE PIPE. ‘THE BENCHING IN INSPECTION CHAMBERS /MANHOLES SHOULD HAVE SMOOTH SURFACE OF CEMENT PLASTER WITH A FALL OF 1:6. BENCHING FOR INCOMING BRANCHES SHOULD BE INCLINED TOWARDS MAIN DIRECTION OF FLOW. ACUTE ANGLE CONNECTIONS ARE NOT ALLOWED IN JUNCTION MANHOLES. AT A JUNCTION, THE TOPS OF ALL ' SEWERS SHOULD BE AT THE SAME LEVEL SO THAT THE PIPES OF SMALLER DIAMETER ARE NOT FLOODED WHEN THE BIGGER PIPES ARE RUNNING FULL. 17. 18. 19. 20. 21. BACKDROP SHOULD BE PROVIDED WHEN THE LEVEL DIFFERENCE BETWEEN INCOMING AND MAIN SEWER IS CONSIDERABLE. ANY INSPECTION CHAMBER/ MANHOLE/GULLY TRAP CONSTRUCTED IN COVERED AREAS SHOULD BE DRY TYPE WITH RECESSED TYPE DOUBLE SEAL COVER. DISTANCE BETWEEN EXTERNAL M.H. TO M.H. SHALL, NOT EXCEED 15 METERS (VILLAS AND BUILOINGS.) MANHOLES SIZES SHALL BE AS FOLLOWS: UPTO 1300MM DEEP = — 600X600 WITH 600X600 COVER FROM 1301 TO 1700MM DEEP - 800X800 WITH 600X600 COVER FROM 1701 TO 2500 - 1000s WITH 600 # COVER FROM 2501 TO ABOVE ~ 15009 WITH 600g COVER (ALL 10008 AND 1800¢ MANHOLE, SHALL HAVE GRP LININGS). CHECK WITH DM DRAINAGE CONSULTANTS FOR LEVELS AND LOCATION OF DM MANHOLES, FOR FINAL CONNECTION. op teat G3® A. PIPING a ALL WAL PIPING, SHALL BE upvc TO BS 4514 IEXCEPT WASTE PIPING WHICH SHALL BE TO Bs! 5256, ALL U/@ PIPING SHALL BE TO Bs 4660. * e ANY OTHER MATERIALS SHALL BE TO DM APPROVAL. ALL VERTICAL STACKS SHALL BE PROVIDED WITH RODDING EYES AT JUNCTIONS ON EVERY FLOOR. ALL HORIZONTAL DRAINAGE PIPES SHALL HAVE RODDING EYES AT ALL CHANGES IN DIRECTION OR AS REQUIRED FOR EFFECTIVE wee 27. 640 STACK SIZES SHALL BE AS FOLLOWS := SOIL PIPE £ = 100MM WASTE 7 100MM ‘VENT PIPE - 75MM RAIN WATER PIPE = t00iN BALCONY ORAIN PIPE ~ 5OMM B. MANHOLES MANHOLES AND ACCESS CHAMBERS SHALL BE IN ACCORDANCE WITH ARCHITECT'S REQUIREMENTS, WITH THE COVERS BEING SUITABLE FOR THE LOADS THEY ARE SUBJECTED To, IN ACCORDANCE WITH BS 487. ANY MANHOLES LOCATED IN GARAGE WAY OR OTHER TRAFFIC. AREAS SHALL HAVE HEAVY DUTY COVERS. LAST MANHOLES FOR FINAL CONNECTION TO OM SEWER SHALL HAVE HEAVY DUTY 800X800 MM COVER WITH AIR TIGHT DOUBLE SEAL DUCTILE IRON FRAME WITH GRP SEALING TRAY. THIS NANHOLE SHALL. HAVE ONLY ONE INCOMING CONNECTION. FOR VILLA'S LAST MANHOLE SHALL BE INSIDE THE PLOT FLASH WITH PLOT LIMIT WITH 6MM THICK GRP SEALING PLATE ANO CAST IRON COVER OF 115 ka. IN BASEMENT, SAND TRAP IS REQUIRED JUST BEFORE FINAL CONNECTION To suMP-PuMP PIT AN|| °° FOR THE RAMP DRAIN CHANNEL. Of Ga) If THERE ARE SHOPS IN THE GROUND 4B. FLOOR, GREASE TRAP TYPE-C SHALL BE PROVIDED AT BASEMENT AND CONNECTED TO THE DRAINAGE SYSTEM FOR FUTURE CONNECTION FROM THE SHOPS. (IN THESE CASES SEPARATE VENT PIPE CONNECTION FOR EACH SHOPS IS NOT NECESSARY). IF BASEMENT SUMP PUMP IS FOR SOIL, WASTER AND RAIN WATER COLLECTED FROM THE BASEMENT, CONNECT ONE WASTE PIPE FROM THE NEAREST TOILET TO BE BASEMENT DRAINAGE LINE TO MAKE IT ALWAYS WET. OUTSIDE PLOT LIMIT, ONLY ONE MANHOLE SHALL BE ALLOWED. FOR CONSTRUCTING MORE THAN ONE MANHOLE, PRIOR NOG FROM HEAD OF DM DRAINAGE SECTION SHOULD BE OBTAINED. THE DEPTH OF FIRST MANHOLE SHALL BE 450 MM MINIMUM,” Z SLOPES FOR HORIZONTAL RUNS SHALL BE AS FOLLOWS: 100 - 1:80 150 = 1:90 200 - 20 ALL INSPECTION CHAMBERS/MANHOLES SHOULD BE BUILT ON BEO OF CEMENT CONCRETE 1:4:6. THE THICKNESS OF THE CONCRETE SHALL BE 150MM FOR MANHOLES UPTO 1000MM DEEP AND 200MM FOR DEPTHS ABOVE 1000MM. 10. MW. 12, 13, 14, 15. 16. 17. UNDERGROUND PIPE LINES WITH TOP OF PIPE LESS THAN 600MM DEEP FROM FFL SHALL BE SURROUNDED WITH 150MM THICK CONCRETE. W.C, LOCATED ON GR. FLOOR SHALL NOT BE CONNECTED TO VERTICAL STACK DISCHARGING AT GR, LEVEL. MINIMUM REQUIREMENT FOR MANHOLE VENTING IS PROVISION OF VENT PIPE TO FIRST AND LAST MANHOLES OR DRAINAGE LINE, THESE VENTS SHALL BE FIXED SUCH THAT ToP OF PIPE SHALL BE {OOMM BELOW COVER LEVEL. VENT PIPES FROM MANHOLES AND VENTS FOR VERTICAL STACKS SHALL BE EXTENDED 2 METERS ABOVE ROOF AND VENT COWLS SHALL BE PROVIDED ON TOP. | Bac URINALS SHALL BE CONNECTED TO SOIL PIPES. RODDING EYE SHALL BE PROVIDED WHEN MORE THAN ONE W.C.'S ARE CONNECTED TO HORIZONTAL SOIL PIPE. RODDING EYE IS TO.BE PROVIDED WHEN DISTANCE BETWEEN W.C. AND STACK/MANHOLE IS MORE THAN 4 METERS. ALL SHOPS SHOULD HAVE W.P. AND V.P. CONNECTION PROVISIONS FOR FUTURE AS PER DM DETAILS. ALL A/C AND BALCONIES DRAINS TO BE CONNECTED TO WASTE SYSTEM VIA THE NEAREST FLOOR TRAPS OR WASTE STACKS, 18. Be 20. 21. 22. 23. 24. 25, OW THE DRAINAGE PIPES SHALL NOT RUN, THOROUGH ELECTRICAL ROOM AND ELECTRIC SUB-STATION. FOR RAIN WATER PIPES, PROVIDE 45 DEG. OR 90 DEG. BENDS AT THE BOTTOM OF STACKS, FLEXIBLE POLYETHELENE PIPES SHALL, NOT BE USED FOR A/c CONDENSATE DRAIN PIPING. ALL BENDS AT BASE OF STACKS SHALL BE LONG RADIUS TYPE. ANY VERTICAL DRAIN PIPES CAST INTO RCC STRUCTURE ELEMENTS SHALL BE SUBJECT TO APPROVAL BY DM STRUCTURE ENGINEER. IN SINGLE STACK SYSTEM, ANY HORIZONTAL PIPES LONGER THAN 1.5 METERS FROM FIXTURES SHALL BE VENTED ON THE HIGH SIDE. FOR WASTE SYSTEM CONNECTION FROM FLOOR DRAIN TO FLOOR DRAIN IS NOT ALLOWED. FOR SWIMMING POOLS IN THE ROOF OR UPPER FLOORS. BRING SEPARATE 2" DIA PIPE. (AFTER PROVIDING REGULATING VALVE) TO THE GRO. FLOOR MANHOLE OR TO THE BASEMENT hw Et @40 9. FOR VEHICLE WASH AND SERVICE STATIONS, OIL INTERCEPTORS MUST BE PROVIDED AS PER DM -REGULATIONS. 10. DRAINAGE FOR THE SW. POOLS AND BACKWASH PUMPS SHALL BE SHOWN ON SEPARATE DRAINAGE LAYOUTS, 4s ALL 0.T.8°S (4X4 AND LESS) SHOULD HAVE FLOOR TRAPS FOR RAIN WATER CONNECTED TO THE NEAREST GULLY TRAP OR WASTE STACK, OTHER OTS'S SHALL HAVE RWO’S FOR RAIN WATER WHICH IS FREE DISCHARGE TO OUTSIDE. 12. FOR PROJECTS HAVING LARGE RAIN CATCHMENT AREAS, RAINWATER DRAINAGE SCHEME SHALL’ BE DESIGNED TO DM APPROVAL. 13. IN ORAINAGE DRAWINGS NOTIFY GARBAGE ROOM, ELECTRICAL-ROOMAND. SUBSTATION. THESE NOTES ARE GENERAL SOME OR ALL OF THESE NOTES MAY BE APPLICABLE TO THIS PROJECT, IN CASE OF ANY t DISCREPANCY, ENGINEER'S DECISIONS. SHALL BE BINDING AND FINAL. TL NO SEPTIG TANK OR SOAKAWAY IS ALLOWED | OUTSIDE THE PLOT LIMIT WITHOUT N.O.C. FROM HEAD OF DRAINAGE SECTION. IF SIZE OF PLOT IS MORE THAN 50X50 FEET SEPTIC TANK SHOULD BE ‘CONSTRUCTED INSIDE THE PLOT. = 3. SEPTIC" TANK SHOULD BE CONSTRUCTED NENTMUM 100MM AWAY FROM ANY EXISTING BLDG. OR COMPOUND WALL FOOTING. 4. SOAKAWAY SHOULD BE MINIMUM 000MM AWAY FROM THE SEPTIC TANK~ 5. SOAKAWAY SHOULD BE FILLED WITH BOULDERS OF SIZE 7SHM TO 100MM. 6. GRP SEALING SHALL BE PROVIDED FOR % LAST MANHOLE TO THE SEPTIC TANK AND 4 THE MANHOLE FOR THE FUTURE CONNECTION TO THE OM SEWER LINE. DRAINAGE DRAWINGS SUBMISSION TO MUNICIPALITY IN THE DRAWINGS SETS SUBMITTED TO DM, ALL DRAWINGS MUST BE KEPT TOGETHER IN THE FOLLOWING ORDER- 4, AFFECTION PLAN SHOWING NOC FORM DM DRAINAGE SECTION AND DETAIL OBTAINED FROM RESPECTIVE OM DRAINAGE CONSULTANT REGARDING DM SEWER LINE~ 2. COMPLETE SETTING-OUT PLAN GIVING DETAILS OF ALL SIDES OF PLOT, (ROAD, SIKKA, ADJACENT PLOT ETG.)- 3. DRAINAGE LAYOUTS FOR ALL FLOORS, INCLUDING ROOF PLAN SHOWING RW.P a V.P., S.Pay WePoy ETC. 4. DRAINAGE DRAWING LAYOUT oF SERVANT BLOCKS, IF APPLICABLE. 5. | DRAWINGS SHOWING STANDARD DETAILS FOR DRAINAGE INCLUDING SEPTIC TANK AND SOAKAWAY DETAILS, IF APPLICABLE FCO VERTICAL STACKS ETC.»

You might also like