Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

WATER JACKET [4N5837] DECEMBER 09, 2019

For Help Desk Phone Numbers Click here


Component Performance Number: TM3040
Water Pump: 4N5837 , 4N5837
Drive Ratio: 1
Sales Model: 3412
A/C: JW
Engine Equipped with: W/C MANIF DRY MANIF
Engine Speed RPM: 1,200
Pump Speed RPM: 1,200
EXT EXT
RESIST FLOW
FT H2O GPM
1.97 144.77
2.3 142.65
4.27 137.37
5.58 132.09
6.89 126.8
8.2 121.52
9.19 116.24
10.17 112.01

Engine Speed RPM: 1,500


Pump Speed RPM: 1,500
EXT EXT
RESIST FLOW
FT H2O GPM
2.62 190.2
3.61 184.92
4.59 179.64
6.56 174.35
8.2 169.07
9.84 163.79
11.48 158.5
13.12 153.22
14.76 147.94
16.08 142.65
16.73 140.01
Engine Speed RPM: 1,800
Pump Speed RPM: 1,800
EXT EXT
RESIST FLOW
FT H2O GPM
3.94 224.02
4.59 221.9
6.56 216.62
8.53 211.34
10.83 206.05
12.8 200.77
14.76 195.49
16.73 190.2
18.37 184.92
20.01 179.64
21.65 174.62

Engine Speed RPM: 2,000


Pump Speed RPM: 2,000
EXT EXT
RESIST FLOW
FT H2O GPM
4.59 250.44
5.25 248.32
7.22 243.04
9.51 237.75
11.48 232.47
13.78 227.19
15.75 221.9
18.05 216.62
20.01 211.34
22.31 206.05
23.95 200.77
24.28 199.98
Engine Speed RPM: 2,100
Pump Speed RPM: 2,100
EXT EXT
RESIST FLOW
FT H2O GPM
5.58 259.95
6.23 258.89
8.86 253.61
11.16 248.32
13.78 243.04
16.08 237.75
18.37 232.47
20.67 227.19
22.64 221.9
24.61 216.62
26.25 211.34
27.89 206.05
29.53 200.77
29.86 199.98

Engine Speed RPM: 2,300


Pump Speed RPM: 2,300
EXT EXT
RESIST FLOW
FT H2O GPM
8.2 280.02
11.48 274.74
14.76 269.46
17.72 264.17
20.34 258.89
22.64 253.61
24.61 248.32
26.58 243.04
28.22 237.75
29.86 232.47
31.17 227.19
32.48 221.9
32.81 220.06
Reference
No notes found...
Number: TM3040

Parameters JACKET WATER PUMP PERFORMANCE


Reference: TM6020 DEFINITIONS:
EXTERNAL RESISTANCE IS THE TOTAL COOLANT FLOW RESTRICTION BEYOND
THE ENGINE COOLANT OUTLET INCLUDING ANY RESTRICTION ORIFICE.

EXTERNAL RESISTANCE WOULD INCLUDE:


COOLANT PIPING TO AND FROM THE JACKET COOLANT PIPING.
THE JACKET COOLANT HEAT EXCHANGER SUCH AS A RADIATOR, BUNDLE
COOLER OR SIMILAR DEVICE.

INTERNAL RESISTANCE IS THAT COOLANT FLOW RESTRICTION CAUSED BY THE:


ENGINE OIL COOLER
CYLINDER BLOCK
CYLINDER HEAD
THERMOSTAT AND HOUSING
FLOW RESTRICTION ORIFICE

TOLERANCE: +/- 5%

Caterpillar Confidential: Green


Content Owner: Commercial Processes Division
Web Master(s): PSG Web Based Systems Support
Current Date: 12/9/2019 9:41:53 AM
© Caterpillar Inc. 2019 All Rights Reserved.
Data Privacy Statement.