Back-UPS User Manual: BX1300LCD-CN / BX1500LCD-CN
Back-UPS User Manual: BX1300LCD-CN / BX1500LCD-CN
®
1 CONTENTS 2 CONNECT BATTERY CARTRIDGE*
RJ-11
RJ-45 RJ-11
RJ-45
w w w.apc.com
USB RJ-45
Back-UPS® 1
Coax Coax
2
BX1300LCD-CN / BX1500LCD-CN
User Manual
Æ
3 OPERATING ENVIRONMENT 4 CONNECT EQUIPMENT / POWER 53 CHECK BUILDING WIRING 6 CONNECT MODEM/PHONE/Network 8 CONNECT DATA LINE AND
FAULT INDICATOR and TVSS Ground If needed, the Back-UPS features INSTALL SOFTWARE ON
If the rear panel Building Wiring Fault (red) indicator is
lit, a potential shock hazard exists due to one of the
a TVSS ground screw for
connecting the ground lead of
COMPUTER (Optional)
following conditions: any additional standalone surge
• Open or high resistance ground suppression devices, such as an
From standalone APC ProtectNet product; or any CABLE IN
FAX • Hot and Neutral polarities are reversed data line surge electronic device with an
• Overloaded neutral circuit RJ-45/ RJ-45/ suppressor or To USB USB RJ-45
external ground connection. Port CABLE OUT
RJ-11 RJ-11 electronic device
Improper building wiring should be corrected by a To USB
qualified electrician. Do not use the Back-UPS until the Port
Building
Wiring
32 - 104°F (0 - 40°C) condition that caused the fault is corrected. RJ-45/ RJ-45/
Fault
Note: Improper building wiring will not prevent the Back- RJ-11 RJ-11
1. Insert CD into computer, and on-screen instructions
Printer or
Printer or Scanner
Scanner UPS from operating, but it will limit its protection Computer should appear automatically. Follow instructions to
Computer capability. Modem Port complete the installation.
Phone Note: if the on-screen instructions do not appear
Jack Phone or Fax automatically (Autoplay is disabled), then
perform steps 2 and 3 below.
External Disk or
2 7 CONNECT COAXIAL CABLES
2. On the computer desktop of the display, double-click
on My Computer.
CD / DVD Drive 3. Double-click on the CD-ROM drive icon, and follow
Monitor Coaxial Cable
From Cable
the on-screen instructions.
30 cm Provider
Installation of the supplied software is the only way to
CABLE IN take advantage of the auto shutdown capabilities that
To Cable Back-UPS offers.
To 120 VAC Wall Outlet Modem
Building Wiring Fault CABLE OUT Coxial Cable
Coaxial Cable Follow the
Indicator on-screen
Building Building instructions.
Wiring Building
Wiring
Fault Wiring
Fault
Fault
Input Voltage
Indicators Sensitivity Range Use When...
Flashing Setting (utility
operation)
One (1) block Low 78 to 142 Vac Input voltage is extremely low or
of the Load extremely high. Not recommended
Capacity bar for computer loads.
Three (3) blocks Medium 88 to 139 Vac The Back-UPS frequently goes on
of the Load (factory battery (ON BATT).
Capacity bar default)
Five (5) blocks High 88 to 136 Vac The connected equipment is
of the Load sensitive to voltage fluctuations.
Capacity bar