Analysis of Result of Plate Load Test

S.no Pier No. of Plate Obtained Settlement Permissible Maximum Permissible Maximum Differential Permissible Maximum Remarks
. Load Test at design SBC from Settlement Settlement as per IS1904:1986 Differential Settlement as
Plate Load Test As per IS 1904:1986 (0.0015L) per IRC 78:2014 (L/400)
1. P-6 19.75mm 50 37.5 62.5 Safe
2. P-13 11.86mm 50 37.5 62.5 Safe