Damcos LPU: Setup new P-net LPU circuit board Service Manual

November 2014 Ed 02

Setup new P-net LPU circuit board


Warning! Disconnect the power before changing the circuit board!

Replace Circuit Board in LPU


1. Replace the P-net LPU circuit board. See “Replace 2. Go to the computer and switch to Project 3.10
Printed Circuit Board” on page 105. using the keyboard; press ALT and TAB and then
select Project 3.10.
The window as of point 3 below should be opened.

Write down the S/N of the new circuit board.


3.

101
Service Manual Damcos LPU: Setup new P-net LPU circuit board
Ed 02 November 2014

Replace Circuit Board in LPU


4. Select Password - Enter Password from the menu. 5. Enter password and press OK.

6. Select Tools - Work offline. This will set the system 7. Select the LPU/valve where the P-net LPU circuit
online. board has been replaced.

8. Double click on the Service Channel. 9. Type in the S/N from the new P-net circuit board
and the select Store and OK.

10.Right click on the valve name and then select 11.The LPU should now work again!
Store. This will download the setting for the LPU.

102
Damcos LPU: Setup new P-net LPU circuit board in VIEW ver. 3.16 Service Manual
November 2014 Ed 02

Setup new P-net LPU circuit board in VIEW


ver. 3.16
Warning! Disconnect the power before changing the circuit board!

Setup New P-net LPU Circuit Board in VIEW ver. 3.16


1. Replace the P-net LPU circuit board. See “Replace Go to the computer and select Status.
Printed Circuit Board” on page 105.

Note! The following procedure should be carried


out on one computer only.

Write down the S/N of the new circuit board.


2. The following window should be opened. 3. In the Node status window browse to the faulty
module. A fault will be indicated with a yellow
square.

103
Service Manual Damcos LPU: Setup new P-net LPU circuit board in VIEW ver. 3.16
Ed 02 November 2014

Setup New P-net LPU Circuit Board in VIEW ver. 3.16


4. Right click on the module and select Change Node. 5. Type in the serial number which is found on the
The below dialog should appear. new/spare P-net LPU circuit board. For the P-net
LPU circuit board the serial number must be fol-
lowed by “PD”. The spare PNetNo is “0”.

6. Press OK and if the old module have been replaced 7. Now the LPU should work again from the worksta-
then select Yes in the next dialog. tion.

104
Damcos LPU: Replace Printed Circuit Board Service Manual
November 2014 Ed 02

Replace Printed Circuit Board


Warning! Disconnect the power before changing the circuit board!

Replace Circuit Board in LPU


1. Remove cover. 2. Disconnect cable with wire.

3. Remove screws. 4. Remove plug.

5. Remove circuit board. 6. Mount the new circuit board.

7. Connect cable and wire. 8. Mount the cover.

105
Service Manual Damcos LPU: Replace Printed Circuit Board
Ed 02 November 2014

106