MR16IN

Series 3

Serial I/O
• Open Architecture: High performance, reliable
16-input Interface Panel platform enables use of hardware with Mercury
OEM partners software solutions
• Easy Expansion: Adds functionality and
flexibility to existing access control systems
• Enhanced Security: Embedded crypto memory
chip provides secured layer of encryption to
protect sensitive data
• Versatile Interoperability: Same reliable
interface and identical footprint as Series
2 Mercury IO modules, enabling seamless
upgrades for existing deployments

The new Authentic Mercury MR Series 3 Serial Input/


Output (SIO) modules enable system expansion of
Authentic Mercury intelligent controllers as part of
Mercury’s distributed architecture. The enhanced
modules offer an improved processor and increased
Features memory, plus feature an embedded crypto memory
• 16 programmable inputs; 2 programmable chip that provides a secured layer of encryption
relay outputs to onboard sensitive data. Built on the Authentic
Mercury open platform, Series 3 modules provide the
• AES 128/256 bit data encryption necessary flexibility for OEMs, channel partners and
• UL 294 recognized, CE compliant, FCC, end customers to choose the controller configuration
RoHS that best fits their needs.

• Configurable input parameters The MR16IN can be used for a variety of applications,
including status annunciation and alarm monitoring
• Initiates commands by operator, by applications such as lighting, heating/cooling, door
time schedules, or by events and elevator control. Devices can also be activated by
the condition of selected system devices, either locally
• Allows for easy and compact or regionally, without host intervention.
clustering of up to 16 uniquely
The panel is dedicated to point control and monitoring,
monitored devices enables OEMs to support 16 general-purpose input
• RS-485 host connectivity circuits. The circuits can be individually set for
sensitivity ranges, timing parameters (normally-
open or normally-closed operations) and end-of-
line resistance values. They can also be declared
supervised and non-supervised. Two programmable
relay outputs are configurable for fail-safe or fail-
secure operation, supporting “On,” “Off,” “Pulse” and
“Repeating Pulse” commands.
The MR16IN Series 3 is the latest generation door
interface module for Authentic Mercury intelligent
controllers, the platform of choice for customers
seeking open architecture access control solutions.

www.mercury-security.com Give your access control system wings.


16-input Interface Panel

MR16IN
Application Notes Specifications
The Mercury MR16IN is an essential Primary Power 12-24 Vdc +/- 10%, 350mA maximum
component that supports Mercury’s Host RS–485, 2-wire, 4,000’
flexible, building-block approach to Communication (twisted pair with shield, Belden 9841)
access control system design. The MR16IN Inputs 16 General Purpose: Programmable circuit type
provides the capacity to link, control and 2 Dedicated: Tamper and Power Monitor
respond to an array of sensors. With its Output Relays Two Form-C Relays:
Normally open contact (NO):
RS-485 connectivity, the MR16IN can be
5A @ 30 Vdc resistive
clustered or distributed to best suit each Normally closed contact (NC):
installation environment. 3A @ 30 Vdc resistive
Dimensions 6.0” W x 8.0” L x 1.0” H
(152mm W x 203mm L x 25mm H)
Temperature 0-70 °C operational, -55-85 °C storage
Humidity 5 to 95% RHNC
Product UL294 Recognized, FCC Part 15 Class A, CE
Compliance Compliant, RoHS (2011/65/EU & 2015/863), EU
REACH (1907/2006), California Proposition 65,
NIST Certified Encryption

Network Switch

To Mercury OEM Host

CAT5/CAT 6

MR51e

EP1502 Door 1
1
2
3
4

RS-485
TB5 TB1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TB5
TB1
NO NC
I1 I9
1 9
C C
I1 I9
2 10
OUT 1 NC NO OUT 9
I2 I10
3 11
A B 1 2 3 4 5 6 7 8 TMP PFL R1 R2 NO NC
K1

K9

I2 I10
TB1 TB2 4 12 TB6 C C
GND DAT CLKBZRLED VO GND DAT CLKBZRLED VO

I3 I11
13
IN1

5
NC NO OUT 10
READER 1

OUT 2
I3 I11
K2

K10

6 14 TB2 TB6
NO NC
IN2

I4 I12
D0 D1

7 15
TB2 C C
I4 I12
8 16
K3

K11
IN3

TB8 K1 TB3
TB3
I5
TB7
I13
OUT 3 NC NO OUT 11
INPUTS

TB9 CT
TB4 OUT 4 NO NC OUT 12
READER 2
IN4

I5 I13
NC BA
C C
K4

K12

TB3
GND I6 I14
S1 1 2 3 4 5 6 7 8 S2 1 2 3 4
IN5

NC NO
D4 D3
D0 D1

C I6 I14
TB3 TB7
BZR TB4 TB8 NO NC
K1

K5

K13

I7 I15
IN6

TB4
NO I7 I15
C C
LED
S2

4 32 1

NC NO OUT 13
IN7

OUT 5
I8 I16
NO
K6

K14

CLK K2 I8 I16
NO NC
D1
MR52+

ON
IN8

|^
S1

C C
8 76 5 4 32 1

TB9
NC
K2

TB5
TMP DAT CT
NC NO OUT 14
D0
K7

K15
S2

OUT 6
GND GND 1
C 2
TB4
NO
TB8
NC
PFL
VO BA 3
4
GND C C
GND
K8

K16

TB10
VIN
NC NO C NC NO C NC

S1

NC NO OUT 115
RLY 1

TR+ 1
2
OUT 7

NO NC
GND 3
4
TR- 5
C C
RLY 2

6
I2 7 OUT 8 NC NO OUT 16
GND
K1

8
TB6 TB1 J2 I2 ON--> TB9
12V PT

RLY 3

TR+ CT A
A
K2
J4

NO C NC NO C NC NO C NC NO C

B
GND

TR-
J1
|^
I1
RS-485

B
J1

NC TB10
CT
S1

K1 BA
TR+
RLY 4
K3

NC K2
GND
I1 TR-
GND BA
ON

RS-485

TB11 TB10
D2

D1

TB7 TB12
TB2 TR+
K4

VIN NC OUT 1
1 23 4 5 67 8
RS-485
RLY 5

K1 TR-
VOUT C
GND TB12

MR50
K5

GND
J1

NO

TB11 NC OUT 2
K6

VIN
RLY 6

C GND
VOUT K2
NO TB11
VIN

MR52
GND
VOUT

GND

MR16IN MR16OUT

Door 1 Door 2

Door 1 Door 2
Door 1

The Authentic Mercury open platform delivers quality assurance derived from the most proven
and reliable hardware in the industry. Driven by our engineering excellence and technology
leadership, Authentic Mercury hardware is designed as an access control platform that easily