EXPERIMENT No 5

Objective: To Study the Practical verification of Average value, Peak


Inverse voltage and Ripple Factor of a Half Wave Rectifier.

Apparatus:
Oscilloscope 01
Function Generator 01
Diode Silicon 01
Resistor 01
Capacitor 01
Project Board 01
Proteus Software

Circuit Diagram:

Procedure:
1. I took apparatus and set it on bread board for implementation of half wave
r rectifier.
2. I took my observations from oscilloscope.
3. Calculations were also made for Average, Peak Inverse Values and Ripple
Factor to verify the measure results
Observations:
Vin Vavg PIV Vr p-p Vdc Ripple Factor=
S NO Volts Volts Volts Vr p-p/Vdc
1. 9V 2.65V 8.32V 3.21V 2.65V 1.21

2. 12V 3.60V 11.31V 4.37V 3.60V 1.21

3. 15V 4.55V 14.30V 5.52V 4.55V 1.21

4. 20V 6.14V 19.28V 7.44V 6.14 1.21

5. 25V 7.73V 24.27V 9.37V 7.73 1.21

Lab Task:
Everyone is required to calculate all the table mentioned values by performing the circuit
on Proteus and by below given formulas picture.

Attach the screen shots of circuit and results.


Conclusion:
Study the Practical verification of Average value, Peak Inverse voltage
and Ripple Factor of a Half Wave Rectifier.

Circuit:

Half Wave Rectification at 15V