Project Ident No.: - Machine Serial No.: -


Controller Serial No.: 21 18 00419 Name: LMB|HZM|LH-ECU-UPCR
Message Count: 8
Group Subgroup Priority Text State Code Time Last Time Occurrenc
undefined undefined fatal ErrPowerSupply (3012) - 0x00049891 3294:22:16 3294:22:16

undefined undefined error ErrAlternator (3020) - 0x00049BB2 2520:34:52 3436:27:56

Engine control unit: Error alternator: Alternator voltage too low compared with power supply
undefined undefined error - 0x00049BB4 2520:34:52 3436:27:56
Cabling of generator to electronic engine control incorrect or defect generator

Engine control unit: Error fuel pressure sensor: Exceed limit2


undefined undefined alert - 0x0004B57D 1188:41:05 1188:41:05
Supervisory threshold 2 exceeded or under-run. FuelPressure no more in the normal operations status.
Engine control unit: Error oil pressure sensor: Short to ground or cable break
undefined undefined alert - 0x0004B514 00:00:00 1480:20:04
Short to ground or break of signal line

Engine control unit: Error alternator: Alternator voltage too low at non running engine
undefined undefined error - 0x00049BB0 840:20:19 840:20:19
Cabling of generator to electronic engine control or battery incorrect, defect generator or drive belt break

Engine control unit: Error oil pressure sensor: Exceed limit2


undefined undefined alert - 0x0004B519 642:39:20 1480:20:18
Supervisory threshold 2 exceeded or under-run. OilPressure no more in the normal operations status.
Engine control unit: Error coolant temperature sensor: Short to power or cable break
undefined undefined error - 0x0004BA29 0:49:07 0:49:07
Short to power supply or break of signal line

Print Time: 2020-08-14 15:02:14


Messages

Last Time Occurrences No. of Occ. Stack Index Startup User Acknowledged Service Acknowledged ControlSystemPath Additional Info 1 Additional Info 2 2000 Speed [1/min] 38
3294:22:16 1 8 No No No 0.0 0x0000

3436:27:56 16 7 No No No 1713.0 0x0000

3436:27:56 18 6 No No No 1713.0 0x0000

1188:41:05 1 5 No No No 918.8 0x0000

1480:20:04 255 4 No No No 114.4 0x0000

840:20:19 1 3 No No No 0.0 0x0000

1480:20:18 255 2 No No No 822.2 0x0000

0:49:07 1 1 No No No 1714.3 0x0000

Print Time: 2020-08-14 15:02:14


Messages

eed [1/min] 3816 EngineMode 2350 FuelQuantity [mm³/st] 2923 CoolantTemp [°C] Error type
0x00000004 0.0 21.6 Supply too high (1)
Alternator voltage too
0x00000004 42.5 55.8 low by running engine
(2)
Alternator voltage too
0x00000004 42.5 55.8 low compare to
supply (4)

0x00000004 36.4 67.6 Exceed limit2 (5)

Cable break or short


0x00000004 0.0 82.8
to ground (0)
Alternator voltage too
0x00000004 0.0 68.6 low by stopped
engine (0)

0x00000004 144.8 82.4 Exceed limit2 (5)

Cable break or short


0x00000004 42.5 1.0
to power (1)

Print Time: 2020-08-14 15:02:14