Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

OZCO Project #895 - Two Tier Pergola 26x16

V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 1
1
26'8 2 "

12'0" beam
1
8'8 2 "
10'0" beam
1'0" CL

1" X 45.00°
8" spacing
15
3 16 " X 45.00°
8" spacing
1'0" 10'0" 9'0"
posts posts

9 15
7' 16 " 8'4 16 "

1
9'6 8 "
5
24'2 8 "

Menards Fixer Upper II


V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 3
12'0"
rafters

16'0"
rafters
1'4" spacing

13
6 16 "
Menards Fixer Upper II
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 4
9'4"

4"

15
3 16 " X 45°

1'0"

1
1'0" 1'2 8 "
9
10' 16 "
5
8'4 16 "
9
7' 16 "

9'4"

13'4"

Menards Fixer Upper II


V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 5
ITEM PART
11 13 7 10 3 8 9 NO. QTY. NUMBER DESCRIPTION
6x6 Post
1 8 51708 Base (6x6-
PB-IW)
8" Post to
2 18 51710 Beam
(P2B-IW-8)
6-8" Joist
Hanger
3 3.984 51739
Flush (JHF-
68-IW)
8" Post to
4 7.8 51717 Beam
(P2B-IW-8)
1 1/2" Hex
2 5 1.6 56621 Cap Nut
(HCN)
Screw,
0.04 56627 OWT 3-3/4"
12 (95mm)
4 Timber
6x6
6 4 Cedar 6x6x10'0"
Post
5 2x8
7 4 Cedar 2x8x16'0"
Board
2x8
8 34 Cedar 2x8x12'0"
6 Board
2x8
9 12 Cedar 2x8x8'8
1/2"
1 Board
2x4
10 13 Cedar 2x4x16'0"
Board
6x6
11 2 Cedar 6x6x4'0"
Post
6x6
12 4 Cedar 6x6x9'0"
Post
2x8
13 8 Cedar 2x8x10'0"
Board
Menards Fixer Upper II
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 6
PART
QTY. DESCRIPTION
NUMBER
6x6 Post Base
8 51708
(6x6-PB-IW)
8" Post to Beam
18 51710
(P2B-IW-8)
6-8" Joist
4 51739 Hanger Flush
(JHF-68-IW)
2" Standard
8 51717 Rafter Clip (RC-
IW-2)
1.5" Hex Cap
2 56621
Nut (HCN)
OWT Timber
1 56627
Screw 3-3/4"

8 6x6x10L 6x6x10
1 6x6x8L 6x6x8

4 2x8x16L 2x8x16
34 2x8x12L 2x8x12
20 2x8x10L 2x8x10

13 2x4x16L 2x4x16

Purchase List
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 7
51739

51708

51710

56627 51717
56621

V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 8
Suggested Tools
(others may be required)
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 26
1" X 45°

cut from 6x6x10L board qty: 4

10'0"

1" X 45° both ends

cut from 6x6x8L board qty: 1

4'0" 4'0"
1" X 45°

cut from 6x6x10L board qty: 4

9'0"

16'0"

cut from 2x8x16L board qty: 4

15
3 16 " X 45° both ends
12'0"

cut from 2x8x12L board qty:34

15
3 16 " X 45.00° both ends
Cutlist
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 10
1
8'8 2 "

cut from 2x8x10L board qty: 12

10'0"

cut from 2x8x10L board qty: 8

16'0"

cut from 2x4x16L board qty: 13

Cutlist
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 11
Mount Base to surface (top view shown)
see post base installation instructions for detailed mounting instructrions & fastener selection
5
24'2 8 "

9'4"

13'4"

step 1
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 12
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

step 2
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 13
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw


3
1'7 4 "

2x8
board
width

step 3
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 14
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

= =

see overview page for


spacing dimensions

step 4
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 15
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

see overview page for


spacing dimensions

step 5
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 16
Tool Required
1/4" Driver

Screw

see overview page for


spacing dimensions

step 6
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 17
Tool Required
1/4" Driver

Screw overhang of rafters equal on both ends

see overview page for


spacing dimensions

step 7
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 18
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

see overview page for


spacing dimensions

step 8
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 19
1
2'8 8 "

2x8
width see overview page for
spacing dimensions

Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

step 9
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 20
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw see overview page for


spacing dimensions

step 10
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 21
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

step 11
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 22
Cap (finger tight)
1
2' 8 " Tool Required
3/8" Driver

OWT Timber Screw

see overview page for


spacing dimensions

step 12
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 23
Cap (finger tight)

Tool Required
3/8" Driver

OWT Timber Screw

see overview page for


spacing dimensions

step 13
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 24
Tool Required
1/4" Driver

Screw

see overview page for


spacing dimensions

step 14
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 25
repeat steps 8-14 on opposite side

Menards Fixer Upper II


V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically
OZCO Project #895 - Two Tier Pergola 26x16 and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information. 26

You might also like