DATE:25/03/2019

REPORT OVERHEAD CRANE 10/5 TONNE


21/03/2019 THURSDAY PROBLEM STARTING
TIME:9.35 BECAUSE OF BURN MOTOR
AM CALLED VIBRANT (VES) TEAM TO REPAIR THE OVER HEAD CRANE
3/22/2019 FRIDAY 5 DIE CANNOT TRANSFER CRITICAL PART
D
3/23/2019 SATURDAY A DIE CANNOT TRANSFER CRITICAL PART
Y
3/24/2019 SUNDAY D
DIE CANNOT TRANSFER CRITICAL PART
U
R
A
T
I
O
N

25/3/2019 MONDAY REPAIR THE OVERHEAD CRANE PIC


TIME: 1.MOTOR 10T REWIND EN.MOHD SAFIEE
2.13 PM 2.MOTOR 5T CHANGE RECTIFIRE MAINTENANCE
DONE 3.TUKAR CONTACTOR UP DOWN

OUTSIDER SERVICES VIBRANT ENGINEERING SERVICES SDN.BHD


CRANE WIRE ROPE 016 3337391 MR.LEE
03 31341766 OFFICE

CAUSES:
1) OVERLOAD WHEN HANGGING THE DIE
2) NOT ENOUGH SUPPLY POWER/ CURRENT
3) SERVICE NEEDED FOR OVERHEAD CRANE

COUNTER MEASURES :