CONCRETE SPUN PILE STRUCTURAL CAPACITY CALCULATION

Date : 13-Aug-2020
Costumer :
Project : Rs Royal Rungkut

Dimension
L : length of spun pile m
do : outer diameter 50 cm
t : wall thickness 9 cm
PC Bar Data
d : diameter of PC Bar 7,10 mm
n : number of PC Bars 24
Aps : nominal PC Bar area 40,00 mm²
fpu : PC Bar ultimate strength 1420,00 MPa
Concrete Data
fc' : concrete compressive strength (cube) 600 kg/cm²
concrete compressive strength (cyl) 51,70 MPa

CALCULATION
Ac : concrete section area 1159,25 cm²
I : inertia moment 255324,30 cm⁴
C : critical point 25 cm
fpei : effective prestress per PC bar 1079,20 MPa
fpe : effective prestress of concrete 9,01 MPa

Axial Load Capacity (compression)


Pa : allowable compression capacity 149,74 ton
Pn : nominal compression capacity 374,35 ton
Pu : ultimate compression capacity 262,04 ton

Axial Load Capacity (tension)


Ta : Allowable tension load 73,98 ton
Tn : Nominal tension load 110,97 ton
Tu : ultimate tension load 99,87 ton

Moment Capacity
Mcr : cracking moment 14,63 ton-m
Mu : ultimate moment 23,86 ton-m