Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ENERGY METERS SACI

W
PREPAID single-phase energy meter CMDP2 NE
The new energy meter from SACI allows you to prepay for the energy and then measure your energy
use. The system uses smart card technology to pay for the energy and recharge the meter.

 Smart card technology for prepayment.


 Brackets for wall mounting option.
 Safety level of energy available in the event of credit running out*.
 Notication of low credit**.
 Output for connection to a centralized system.
 Unused credit can be calculated and returned.

* Operating without credit ** Low credit alarm


The CMDP2 allows you to set a security level of credit The user can set a minimum level of credit and then receive a
available to the user in case the paid for credit runs out. This notication when they reach that limit. An acoustic alarm and
saves against any inconvenient power cuts if the user forgets a visual display on the meter noties the user that they need
EXTRA
to top up their credit. to top up the credit. There is a button on the meter to turn off
the alarm. This limit can be set via the RS485 interface.

“Apartments, campsites, bungalows, tourist apartments, marinas, sports centers, student acommodation ..."

CARD READER RECORDER


The card reader allows you to load or remover credit on the card.

t
r n a n y credi
Retu h e card
o n t
lef t
CONTADORES
ENERGY METERS DE ENERGÍA SACI

Energy mete
TECHNICAL SPECIFICATIONS

VOLTAGE INPUT GENERAL FEATURES


Rated Voltage (Un) 230 V AC Counter type LCD Display
Burden < 10 VA, 2 W Digits 6 + 2 decimal
Operationg range ± 20% Un Nº of counters 1
Frequency 50 Hz Class 1
Operating temperature -20 to +55 ºC
CURRENT INPUT Average annual relative humidity 75%
Current IB (IMAX) 5 (60) A Energy indicator Flashing LED
Burden < 1 VA Pulse weight 1000 pulses / kWh
Operating range 0-100 % IMAX Case material ABS
Starting current (In) 20 mA Terminals Sealable
Connection With screw
PULSE OUTPUT (OPTOCOUPLER) Protection IP 51
Number of outputs 1 Max wire section:
Pulse weight 1 Wh Phase input terminals 25 mm2
Type SO (DIN 43864) Optocoupler Communications and pulses 0,75 mm2
Insulation 3 kV, 1 min.
Maximum current < 20 mA Wall mounting
Mounting
Voltage < 24 V DC. Meter cabinet
Pulse length > 50 ms

DIMENSIONS

Height: 171,5 mm
Width: 106 mm
Depth: 54,5 mm
Weight: 530 g

FRONTAL DESCRIPTION CONNECTION DIAGRAM

A LCD Display.
B Button
C IR optical reader.
D LED indicator for active energy
E LED indicator for reverse energy.
F Technical information

S.A. DE CONSTRUCCIONES INDUSTRIALES. C/Aragoneses 15, 28108 Alcobendas (Madrid)


saci@saci.es (+34) 91 519 02 45 www.saci.es

You might also like