Dear Customer,
The guarantee on this appliance is
Thank you for choosing an ARISTON valid for 24 months from the first
boiler. day of installation.
We guarantee that your boiler is a reliable
Repairs to the electric, hydraulic
and technically sound product.
or gas circuits may be carried out
This User's Manual provides detailed only by your local authorised MTS
instructions and recommendations for Servicing Centre.
proper installation, use and maintenance.
Remember to keep this manual in a safe
place for future reference i.e. by the gas
meter.
Your local MTS Servicing Centre is at your
Every attempt has been made to avoid
complete disposal for all requirements.
errors of any kind
in this User's Manual, the Management
invites customers to inform
of any inaccuracies which they may find.
This will help to improve our service

2
TABLE OF CONTENTS

1. GENERAL INFORMATION page 4


Technical Information page 5
Control Panel page 6
2. OPERATING INSTRUCTIONS page 8
3. USEFUL INFORMATION
AND TROUBLESHOOTING page 14
4. MAINTENANCE page 16
5. CHANGE OF GAS TYPE page 16
6. TIME CLOCK page 17

IMPORTANT!
Please read this manual carefully.
For additional information, please consult the “Installation and Servicing
Instructions.”
Make sure to keep the manuals provided with the appliance so that they
can be used by the end-user, installer or our authorised engineer.

3
1. GENERAL INFORMATION use.
Do not allow children or inexperienced
persons to use the appliance without
MTS (GB) Limited support the
supervision.
initiative. Your installer will give you, and
If you smell gas in the room, do not turn
show you how to use, a logbook which will
on light switches, use the telephone or
give you important information about your
any other object which might cause
boiler, and heating system. Please have
sparks.
this logbook to hand whenever you
Open doors and windows immediately to
contact a service engineer or us.
ventilate the room.
All CORGI Registered Installers carry a
Shut the gas mains tap (on the gas meter)
CORGI ID card, and have a registration
or the valve of the gas cylinder and call
number. Both should be recorded in
your Gas Supplier immediately.
your boiler Logbook. You can check
If you are going away for a long period of
your installer is CORGI registered by
time, remember to shut the mains gas tap
calling CORGI direct on :- (01256)
or the gas cylinder valve.
372300.
This is a combined appliance for the
Before any intervention within the
production of central heating (C.H.) and
boiler it is first necessary to cut off the
domestic hot water (D.H.W.). This
electrical power supply by turning the
appliance must be used only for the
external switch to “OFF”.
purpose for which it is designed. The
This manual may be kept in the front
manufacturer declines all liability for
panel of the boiler.
damage caused by improper or negligent
4
TECHNICAL INFORMATION
GENERAL DATA 23 kW 27 kW
Heating input max-min kW 25.6-11.0 29.8-12.0
Heating output max-min kW 23.8-9.7 27.8-10.5
Efficiency at Maximum Thermal Capacity (see % 92.9 93.5
installation instructions)
CENTRAL HEATING
Operating Temperature max-min °C 82-42 82-42
Maximum-Minimum Heating Pressure bar 3-0.7 3-0.7
Built-in expansion vessel - Total capacity litres 6 6
DOMESTIC HOT WATER
Maximum-Minimum Temperature of
Water for Domestic Use °C 56-36 56-36
Working pressure max-min bar 8-0.2 8-0.2
Flow rate ∆T 25°C l/min 13.6 ?
Flow rate ∆T 35°C l/min 9.7 ?
Minimum flow rate l/min 2.6 2.6

ELECTRICAL DATA
Electrical Supply/ Frequency V/Hz 230/50 230/50
Power Consumption W 140 155
Protection of Electrical System IP X4D X4D

CATEGORY
Nominal Pressure/Methane Gas (G20-G25) mbar 20-25 20-25
Nominal Pressure/Liquid Gas (G30-G31) mbar 30-37 30-37
5
CONTROL PANEL

FR025A
23/27 MFFI
6
LEGEND:

A - On/Off knob K - Central heating temperature


B - Domestic hot water temperature L.E.D (yellow)
adjustment knob L - Time clock
C - Central heating selection M - Heating system pressure gauge
(winter) and temperature
adjustment knob
D - On/Off L.E.D. (green)
E - Fume sensor L.E.D. (yellow)
F - Ignition failure (lockout)
L.E.D. (red)
G - “Economy/Comfort” mode
selection knob
H - Ignition failure (lockout) and/or
overheat reset button
I - Overheat L.E.D. (red)
J - Low system water level
L.E.D. (red)

7
2. OPERATING INSTRUCTIONS HELPFUL SUGGESTIONS
CAUTION
Installation, start-up, adjustments To get the most out of your boiler, we
and maintenance must be performed have provided you with some useful
by a competent person only, in advice on proper use and
accordance with the current Gas maintenance:
Safety (Installation & Use) - Periodically check the system
Regulations and the instructions pressure using the pressure gauge
provided. Improper installation may “M”, make sure that the pressure is
cause damage or injury to between 1.0 and 1.5 bar (the blue
individuals, animals and personal part on the gauge) when the system
property, for which the manufacturer is off and cool. The warning L.E.D.
will not be held liable. “L” will indicate if the pressure is
To ensure efficient and safe below the minimum recommended
operation it is recommended that
the boiler is serviced annually by a M
competent person.
If it is known or suspected that a
fault exists on the appliance, it must
not be used until the fault has been
corrected by a competent person.
UT009A
8
value. Consult your installer for reducing gas consumption and
checking and refilling the system. maintenance costs.
- The outer panels of the unit's case - If the boiler should be out of use for
must only be cleaned with a damp a prolonged period, it is
cloth. Do not use abrasive cleaners. recommended that the electrical
The control panel can be wiped with power supply be disconnected and
either a damp or dry cloth. Spray that the external gas cock be closed.
polishes must not be used on the If low temperatures are expected,
control panel surface or knobs. Care the boiler and system pipe work
must be taken in preventing any should be drained in order to prevent
liquid entering the appliance. frost damage.
- To improve comfort and take full
PRACTICAL TIPS advantage of the heat produced by
the boiler, it is recommended that an
- If the water is very hard, it is external (room) thermostat be
recommended that a water softener installed.
be added to the system so as to - It is good practice to clean and
reduce the formation of limescale in service the appliance and central
the boiler exchangers. This will heating system every year.
ensure that the efficiency of the unit Call an Authorised Service Centre.
remains the same over time,
9
IGNITION PROCEDURE boiler fail to ignite a second time, check
that the external gas cock is open. If the
Turn the selector knob “A” to the “J” problem persists, contact an
position. The green L.E.D. “D” will Authorised Service Centre.

D A
F H
RESET
UT011Aa UT011Aq

illuminate indicating that the boiler is UT011Ac UT011Ad

ready to operate. The centralised


electronic control unit will ignite the WINTER AND SUMMER
burner, without any manual intervention OPERATING MODES
but in response to the request for
domestic hot water or heating. If, after In the ‘winter operating mode’, the
approximately 10 seconds, the burner boiler will produce both central heating
has not ignited, the boiler safety and domestic hot water. In the ‘summer
devices will shut off the gas and the red operating mode’, the boiler will produce
L.E.D. “F” illuminates. To reset the only domestic hot water.
ignition system, the reset “H” must be Using the knobs on the control panel,
pressed and released. Should the
10
the user can select winter or summer somewhere between min. and max., a
operating mode. Keeping the knob “C” temperature may be obtained which
at the “0” position selects the summer varies from approximately 45˚C to
operating mode. Winter operating about 80˚C.
mode may be selected by positioning
the knob “C” between the min. and K
max. settings.
The water

UT011An
temperature in
ADJUSTING THE HEATING
the primary circuit
summer winter may be checked by
means of the yellow L.E.D.s
“K”.

EXTERNAL (ROOM) THERMOSTAT


CONTROL
C UT011Ae UT011Af
C
If an external (room) thermostat is
It is possible to set the temperature of installed, it is recommended that the
the heating system by adjusting the temperature of the heating system be
knob “C”. By positioning the indicator set by means of the “C” knob, leaving
11
it at max in order to temperature for the water may be
obtain the best chosen in a range from 36˚C to about
performance from 56˚C, depending on the flow rate of the
the boiler and to water and the position of the knob
allow the regulation between the min. and max. settings.
of the external C
UT011Ar
temperature to
function efficiently. ECONOMY/COMFORT MODE

G
The selector knob

economy
“G” allows the user
SETTING THE HOT WATER FOR to choose the

UT011Ah UT011Ag
DOMESTIC USE economy mode
(position “E”) or the
Both in the winter and summer mode, comfort mode

comfort
the temperature of (position “C”).
the domestic hot The economy mode
water may be is the normal state
adjusted by using for the operation of
the “B” knob. A the boiler, since the domestic water is
d e l i v e r y B heated up only when a tap is turned on.
UT011As
12
The comfort mode is a special TURNING OFF THE BOILER
operating state, because the water
contained in the secondary exchanger To turn the boiler off, rotate the selector
and in the primary exchanger is kept in knob “A” to the “0” position (OFF); the
a preheated condition, thereby allowing respective green L.E.D. “D” will go off.
a quicker delivery of domestic water Close the gas cock located under the
when required. The latter is therefore boiler and turn the electricity supply
the more convenient choice. switch (located outside the boiler) to
the OFF position.
TURNING OFF CENTRAL HEATING
A D
To turn off the central heating, rotate
the “C” knob to the “0” position.
The boiler will
stay in summer UT011Ab UT011Aa

mode, just C
p r o v i d i n g
domestic water
on request.
UT011Ae

13
L.E.D. “F” will illuminate. In order to
3. USEFUL INFORMATION reset the ignition, the button “H” must
be pressed and released. Should the
AND TROUBLESHOOTING boiler fail to ignite a second time, check
that the external gas cock is open. If the
BOILER SHUTDOWN SITUATIONS problem persists, contact an
Authorised Service Centre.
The boiler is equipped with safety
devices that intervene in certain
situations and shut it off. Most of these
SHUTDOWN DUE TO OVERHEATING
situations are communicated by means
of the L.E.D.s and at times the user In the event that the safety limit is
may be able to remedy them. exceeded for the temperature of the
water in the boiler’s primary exchanger,
SHUTDOWN DUE TO IGNITION the thermostat shuts off the boiler and
the red L.E.D. “J” illuminates.
FAILURE
To remedy this situation, wait a few
In the event that
J minutes to allow the exchanger to cool
the automatic down, then press and release the reset
ignition of the RESET button “H”.
burner has If this situation occurs frequently,
H
failed, the red F contact an Authorised Service Centre.
UT011Ai
14
SHUTDOWN DUE TO INSUFFICIENT within the system, have a plumber
check the heating system for possible
WATER CIRCULATION
water leaks.

If the red L.E.D. “L” is TEMPORARY SHUTDOWN DUE TO


L DEFECTIVE DISCHARGE OF
illuminated and the
boiler is off, one EXHAUST FUMES
possible cause for this
state is an insufficient UT011Al
The boiler is fitted with safety devices,
pressure of water in the system. which in the event of a defective
Check the system pressure on the discharge of exhaust fumes,
pressure gauge “M” and if it is less automatically interrupts the gas supply,
than 0.5 bar, consult your installer for thereby shutting off the boiler.
checking and refilling the system. The shut-off of the boiler is temporary
Then turn off and turn back on the and is indicated by the illumination of
boiler by means of the selector knob the yellow L.E.D. “E” for a period of
“A”. If the boiler does not start up about 15 minutes.
again and the L.E.D. “L” remains Once this time period has passed and
illuminated, contact an Authorised the discharge state of exhaust fumes
Service Centre. has returned to normal, the boiler
If there are frequent drops in pressure automatically turns back on.
15
IMPORTANT! 4. MAINTENANCE
If this situation occurs frequently,
contact an Authorised Service Centre. Schedule an annual maintenance
so that they may check that the exhaust check-up for the boiler with a
fumes are being expelled correctly and competent person.
that the area is ventilated properly. Correct maintenance always results in
savings in the cost of running the
ANTI-FROST DEVICE system.

The boiler is fitted with a device which, 5. CHANGE OF GAS TYPE


in the event that the water temperature
goes below 5°C, the three-way diverter Our boilers are designed to function
valve switches to domestic hot water either with Natural Gas (methane) or
and the burner turns on at minimum LPG gas. If you need to changeover
power until the water in the boiler has from one gas to the other, one of our
reached a temperature of about 50°C. Authorised Service Centres should be
This device is only activated when the contacted.
boiler is operating perfectly and
- the system pressure is sufficient;
- the boiler is powered electrically;
- gas is being distributed.

16
6. TIME CLOCK inside (off setting) to the outside of the
clock border (on setting), the circuit is
closed (switch on) for a period of 15
minutes and then the boiler starts if the
room thermostat (if installed) or the
heating thermostat require heat
(heating function on).

EXAMPLE
To set the heating of your home in
the time interval from 7.00 am to
9.30 am and from 7.00 pm to 10.00
pm every day:
UT011Ap
- rotate the outer ring of the clock in a
clockwise direction until the correct
NOTE: the time clock is for central
time of day (24h) lines up with the
heating control only.
arrow on the clock (at approx. 2
The time clock is provided with 96
o’clock position);
switches, called riders, each of which
- under no circumstances should the
covers a time interval of 15 minutes
minute hand be moved manually;
(four per hour).
- make sure all the switches, i.e. the
When a rider is switched from the
riders, are placed on the inside of the
17
clock border; on and will only shut off upon the
- pull outward the riders for 7.00 am request of the room thermostat (if
and 9.30 am, and then all riders installed) or the heating thermostat;
between these two;
- repeat this for 7.00 pm and 10.00 2. Position “O”
pm. HEATING OFF: in
Other heating intervals may be set in this position, the
the same way. clock circuit is always
The timer has approximately 150 open (switch off) and
hours of battery back up for power the boiler will
failure. therefore never ignite UT014A
for heating;
The clock is provided with a selector
switch with three positions (see figure): 3. “Central” Position
PROGRAMMING
1. Position “I” ACTIVE: in this
CONSTANT: in this position, the
position, the clock programming set
circuit is always by the user is
closed (switch on), active. UT014A

therefore the boiler


will constantly be UT014A
18
TECHNICAL DATA

Ambient
temperature: - 10°C to + 55°C
Running
reserve: 150 h (not for 1.5 V DC)
Shortest
switching time: 15 minutes
Programmable: Every 15 minutes

19
Stampa: Bieffe Recanati
Cod. 2399841468112 -
Manufacturer: Merloni TermoSanitari SpA - Italy

Commercial subsidiary: MTS (GB) LIMITED


MTS Building
Hughenden Avenue
High Wycombe