Professional Documents
Culture Documents
Current Transducer LF 1005-S/SP4 I 520 A
Current Transducer LF 1005-S/SP4 I 520 A
Preliminary
Electrical data
991115/1
Bottom view
Top view
• General tolerance ± 0.5 mm • IS is positive when IP flows in the direction of the arrow.
• Fastening 2 holes ∅ 6.3 mm • Temperature of the primary conductor should not exceed
or 4 holes ∅ 5.3 mm 100°C.
or 4 holes ∅ 4.2 mm • Dynamic performances (di/dt and response time) are best
or 4 x PT KA30 screws with a single bar completely filling the primary hole.
depth 10 mm
or 4 x PT KA30 screws
depth 16 mm
• Primary through-hole 40.5 x 40.5 mm
• Connection of secondary M4 threaded studs
Fastening torque 1.2 Nm or .88 Lb. - Ft.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.