Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Current Transducer LF 1005-S/SP4 IPN = 520 A

For the electronic measurement of currents : DC, AC, pulsed...,


with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).

Preliminary

Electrical data

IPN Primary nominal r.m.s. current 520 A Features


IP Primary current, measuring range 0 .. ± 1500 A
RM Measuring resistance RM min RM max • Closed loop (compensated) current
with ± 24 V @ ± 520 A max 20 135 Ω transducer using the Hall effect
@ ± 1500 A max 20 28.5 Ω • Insulated plastic case recognized
according to UL 94-V0.
ISN Secondary nominal r.m.s. current 130 mA
KN Conversion ratio 1 : 4000 Special features
VC Supply voltage (± 5 %) ± 24 V
IC Current consumption 20 + IS mA • IPN = 520 A
Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 6 kV • K N = 1 : 4000
• VC = ± 24 (± 5 %) V
Accuracy - Dynamic performance data • Connection to secondary circuit on
M4 threaded studs.
XG Overall accuracy @ IPN , TA = 25°C ± 0.6 %
ε L
Linearity < 0.1 % Advantages
Typ Max • Excellent accuracy
IO Offset current @ IP = 0, TA = 25°C ± 0.5 mA • Very good linearity
IOT Thermal drift of IO - 10°C .. + 70°C ± 0.3 ± 0.5 mA • Low temperature drift
tr 1)
Response time @ 90 % of IPN <1 µs • Optimized response time
di/dt di/dt accurately followed > 100 A/µs • Wide frequency bandwidth
f Frequency bandwidth (- 1 dB) DC .. 150 kHz • No insertion losses
• High immunity to external
interference
General data
• Current overload capability.

TA Ambient operating temperature - 10 .. + 70 °C Applications


TS Ambient storage temperature - 25 .. + 85 °C
RS Secondary coil resistance @ TA = 70°C 29 Ω • AC variable speed drives and servo
m Mass 500 g motor drives
Standards 2) EN 50178 • Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
Notes : 1)
With a di/dt of 100 A/µs applications.
2)
A list of corresponding tests is available

991115/1

LEM Components w w w .lem.com


Dimensions LF 1005-S/SP4 (in mm. 1 mm = 0.0394 inch)

Bottom view

Front view Back view

Top view

Secondary terminals Connection

Terminal + : supply voltage + 24 V


Terminal M : measure
Terminal - : supply voltage - 24 V

Mechanical characteristics Remarks

• General tolerance ± 0.5 mm • IS is positive when IP flows in the direction of the arrow.
• Fastening 2 holes ∅ 6.3 mm • Temperature of the primary conductor should not exceed
or 4 holes ∅ 5.3 mm 100°C.
or 4 holes ∅ 4.2 mm • Dynamic performances (di/dt and response time) are best
or 4 x PT KA30 screws with a single bar completely filling the primary hole.
depth 10 mm
or 4 x PT KA30 screws
depth 16 mm
• Primary through-hole 40.5 x 40.5 mm
• Connection of secondary M4 threaded studs
Fastening torque 1.2 Nm or .88 Lb. - Ft.

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.