Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool- Structural Analysis
by:
CDPGroup-02

Ref Calculations Output

Structural Analysis

Long wall

L3
L1 L2

Mvs

Mhs
L1`
Mhm

Mvm

Bending Moment

Serviceability Limit State

Mvm(KNm/m) Mvs(KNm/m) Mhm(KNm/m) Mhs(KNm/m)

L1 20.3 38.2 5.7 7.9

L2 30.3 49.2 7 13.9

L3 25 53 5.1 10.4
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool- Structural Analysis
by:
CDPGroup-02

Ref Calculations Output

Ultimate Limit State

Mvm(KNm/m) Mvs(KNm/m) Mhm(KNm/m) Mhs(KNm/m)

L1 28.5 53.5 7.5 11

L2 42.3 68.9 9.7 19.5

L3 35.3 75.3 7.2 14.6

Short Wall

Serviceability Limit State

Mvm(KNm/m) Mvs(KNm/m) Mhm(KNm/m) Mhs(KNm/m)

Wall 22.5 39.8 5.6 8.2 /-6.6

Ultimate Limit State

Mvm(KNm/m) Mvs(KNm/m) Mhm(KNm/m) Mhs(KNm/m)

Wall 31.6 55.7 7.9 11.5/ -9.3


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool- Structural Analysis
by:
CDPGroup-02

Ref Calculations Output

Bottom Slab

Serviceability Limit State

Mxm(KNm/m) Mys(KNm/m) Mxm(KNm/m) Mxs(KNm/m)

S1 33.5 58.1 13.9 47.4

S2 28.8 50.1 19.3 41.5

Ultimate Limit State

Mxm(KNm/m) Mys(KNm/m) Mxm(KNm/m) Mxs(KNm/m)

S1 46.9 80 19.6 66.4

S2 40.2 72 27 58
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool- Structural Analysis
by:
CDPGroup-02

Ref Calculations Output

Direct Tension

7.3m

1.5m
F

ULS

Maximum Water Pressure= 9.81*1.4*1.5= 20.6

Total water load= 0.5*20.6*1.5*7.3

Assuming total load is uniformly distributed,

Intensity of load= 0.5*20.6 = 10.3

RHB R= 0.5*k*(1-0.25k)w(lx)2
table 63
= 0.5*1.42*(1-1.42/4)*10.3*1.62 =12.07

Direct tension by long wall= 12.07/1.6 = 7.54 kN/m

SLS

Maximum Water Pressure= 9.81*1.5= 14.72


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool- Structural Analysis
by:
CDPGroup-02

Ref Calculations Output

Assuming total load is uniformly distributed,

Intensity of load= 0.5*14.72 = 7.36

R= 0.5*k*(1-0.25k)w(lx)2

= 0.5*1.42*(1-1.42/4)*7.36*1.62 =8.63

Direct tension by long wall= 8.63/1.6 = 5.4 kN/m


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool - Design
by:
CDPGroup-02

Ref Calculations Output

BS8007

Design of walls

Long wall Design

Thickness of the wall= 200mm


Cl 2.7.6
Cover= 40mm

Reinforcements to carry ULS bending moment

Assume main bars to be 25mm and distribution bars to be 12mm in


BS8110 diameter
Cl d= 200-40-12-25/2 = 135.5 mm
3.4.4.4
Mvm=42.3 kNm/m

Mvs=75.3 kNm/m

M= 75.3 kNm/m

k’=0.156 ( No redistribution)

k= M/(bd2fcu) = 75.3*10^6/(10^3*135.5^2*35)
No
=0.11< k’ (Hence no Compression reinforcement needed) compres
sion r/f
z= d(0.5+(0.25-k/0.9)^0.5) = 0.86d = 0.86*135.5 = 116.5mm
needed
As= M/(0.87*fyz) =73.2*10^6/(0.87*460*116.5) = 1570mm2
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool - Design
by:
CDPGroup-02

Ref Calculations Output

R/f to carry ULS direct tension


T=7.54 kN/m

As=7.54*10^3 / (0.87*460)

= 18.8mm2

R/f to carry Vertical Serviceability BM

M(SLS)= 52.2 kNm/m

M/(bd2)= 52.2*106/(103*135.52)=2.8

Allowable steel stress= fst= 130N/mm^2


BS800-
T3.1 From design chart,
RHB- r= 0.026
T118
fcr= 11.5 N/mm2
r =As/bd
As= 0.026*10^3*135.5 =3523mm2 (At Support)
M= 30.3 kNm/m at span
BS8007
-B2 r= 0.016

As=2032.5mm2

Ultimate stress of concrete= 0.45 fcu = 0.45 *35 =15.8 N/mm2 > fcr = 11.5
Hence Concrete stress is not near the ultimate
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool - Design
by:
CDPGroup-02

Ref Calculations Output

R/f to resist serviceability direct tension in mature concrete (SLS)


Allowable steel stress =130 N/mm2
T3.1
Ast= T/fst = 5.4*10^3/130 = 42 mm2

R/f to resist shrinkage and thermal movement in immature concrete


2.6.2.3

A2 Minimum Steel ratio in each surface zone is given by


r crit = fct/fy = 0.0035
r = As/(bh’)
h’= depth of surface zone
Fig A.1 h’=h/2(h<500mm)
As=0.0035*10^3*100= 350mm2/m

R/f to control crack spacing

A.3 R/f in controlling crack spacing is to be provided according to cl A3


BS8007
Wmax= smax. R. α (T1+T2)
Let’s take T1= 30’c T2=10’C and α= 10**10^-6/’C
R= 0.5 for rigid end restraints
Wmax/smax = 0.5*10*10^-6(30+10) = 2*10^-4
Smax= fct/fb* (F/2r)
fct/fb = 0.67
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool - Design
by:
CDPGroup-02

Ref Calculations Output

BS8007 Using 12mm bars and wmax= 0.2mm


2.2.3.3. Smax= 0.67*12/(2r)
Smax= Wmax/(2*10^-4)=1000mm
r = 0.67*6/1000 = 0.004 <rCrit = 0.0035
As = 0.004 *1000*100 = 400mm2/m
This steel has to be provided in both surface zones.

Long Wall Vertical R/F

R/f to carry ULS BM= 1570 mm2/m


R/f to carry out SLS BM = 3523mm2/m(@ support) ,2032mm2 (@span)
R/f to resist shrinkage and thermal movement = 400 mm2/m each layer

Long Wall Horizontal R/F

R/f to carry ULS tension = 19 mm2/m


R/f to carry SLS tension = 42 mm2/m
R/f to resist shrinkage = 400 mm2/m
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool - Design
by:
CDPGroup-02

Ref Calculations Output

BS R/f provided
8007-
2.6.2.3
Max spacing = lesser of 300 and thickness (200mm) =200mm
Spacing<200mm

Long wall (Vertical)

Y25@200mm

Y25@130mm

Y25@130mm R/f provided= 3776mm2/m


Y25@200mm R/f provided= 2454mm2/m

Long wall (Horizontal)

Y12@ 200mm both sides = 565mm2/m


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

BS8110 Checking for Shear


3.5.5

Ultimate shear stress from the SAP analysis long wall= 1020kN/m2
V=1.02 N/mm2
0.8(fcu)^0.5 = 0.8 (35)^0.5 = 4.73 N/mm2

V< 5 or 0.8(fcu)0.5

As= 3776 mm2


100As/bd = 100*3776/(1000*135.5) = 2.7
Vc= 1.2 N/mm2

v<vc
No shear r/f needed
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

BS8007

Design of walls

Short wall Design

Thickness of the wall= 200mm


Cl 2.7.6
Cover= 40mm

Reinforcements to carry ULS bending moment

Assume main bars to be 25mm and distribution bars to be 12mm in


BS8110 diameter
Cl d= 200-40-12-25/2 = 135.5 mm
3.4.4.4
Mvm=31.6 kNm/m

Mvs=55.7 kNm/m

M= 55.7 kNm/m

k’=0.156 ( No redistribution)

k= M/(bd2fcu) = 55.7*10^6/(10^3*135.5^2*35)
No
=0.086< k’ (Hence no Compression reinforcement needed) compres
sion R/f
z= d(0.5+(0.25-k/0.9)^0.5) = 0.89d = 0.89*135.5 = 121mm
needed
As= M/(0.87*fyz) =55.7*10^6/(0.87*460*121) = 1150mm2
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design by:
CDPGroup-02

Ref Calculations Output

R/f to carry Vertical Serviceability BM

BS8007 M(SLS)= 39.8 kNm/m


-T3.1
M/(bd2)= 39.8*106/(103*135.52)=2.1
RHB-
Allowable steel stress= fst= 130N/mm^2
T118
From design chart,
r= 0.02

fcr= 10 N/mm2
BS8007
-B2 r =As/bd
As= 0.02*10^3*135.5 =2710mm2

Ultimate stress of concrete= 0.45 fcu = 0.45 *35 =15.8 N/mm2 > fcr = 10
Hence Concrete stress is not near the ultimate
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

R/f to resist shrinkage and thermal movement in immature concrete

2.6.2.3 Minimum Steel ratio in each surface zone is given by


A2 r crit = fct/fy = 0.0035
r = As/(bh’)
h’= depth of surface zone
h’=h/2(h<500mm)
Fig A.1 As=0.0035*10^3*100= 350mm2/m

R/f to control crack spacing

R/f in controlling crack spacing is to be provided according to cl A3


A.3 BS8007
Wmax= smax. R. α (T1+T2)
Let’s take T1= 30’c T2=10’C and α= 10**10^-6/’C
R= 0.5 for rigid end restraints
Wmax/smax = 0.5*10*10^-6(30+10) = 2*10^-4
Smax= fct/fb* (F/2r)
fct/fb = 0.67
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

BS8007 Using 12mm bars and wmax= 0.2mm


2.2.3.3. Smax= 0.67*12/(2r)
Smax= Wmax/(2*10^-4)=1000mm
r = 0.67*6/1000 = 0.004 <rCrit = 0.0035
As = 0.004 *1000*100 = 400mm2/m
This steel has to be provided in both surface zones.

Short Wall Vertical R/F

R/f to carry ULS BM= 1150 mm2/m


R/f to carry out SLS BM = 2710 mm2/m
R/f to resist shrinkage and thermal movement = 400 mm2/m each layer

Long Wall Horizontal R/F

R/f to resist shrinkage = 400 mm2/m


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

BS R/f provided
8007-
2.6.2.3
Max spacing = lesser of 300 and thickness (200mm) =200mm
Spacing<200mm

Short wall (Vertical)

Y20@200mm

Y25@180mm

Y25@180mm R/f provided= 2727mm2/m


Y20@200mm R/f provided= 1570mm2/m

Long wall (Horizontal)

Y12@ 200mm both sides = 565mm2/m


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

Bottom Slab 1

3
2

Bending Moments (Considering Both Slab 1 and 2)


Short way, edge M1= 80 kNm/m
Short way, Span M4= 46.9 kNm/m
Long way, edge M2= 66 kNm/m
Long way, Span M3=19.6 kNm/m

R/f to carry ULS bending Moment

M/bd^2 100As/bd As R/f


3.6 1 1475 Y20@200 (1570mm2)
2.1 0.55 811 Y20@200 (1570mm2)
3 0.82 1209 Y20@200 (1570mm2)
0.9 0.24 354 Y20@200 (1570mm2)

Max spacing = 3 *effective depth =3*147.5 =442>200mm


Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

R/f to carry Serviceability BM

Along Short Span


M/(bd2)= 58*106/(103*147.52)=2.6
BS8007
-T3.1 Allowable steel stress= fst= 130N/mm^2
RHB-
From design chart,
T118
r= 0.025

fcr= 11.5 N/mm2


r =As/bd
BS8007 As= 0.025*10^3*147.5 =3680mm2
-B2

Along Long Span


M/(bd2)= 47*106/(103*147.52)=2.1

Allowable steel stress= fst= 130N/mm^2

From design chart,


r= 0.02

fcr= 10 N/mm2
r =As/bd
As= 0.02*10^3*147.5 = 2950 mm2
Ultimate stress of concrete= 0.45 fcu = 0.45 *35 =15.8 N/mm2 > fcr =
11.5,10
Hence Concrete stress is not near the ultimate
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

R/f to resist shrinkage and thermal movement in immature concrete

Minimum Steel ratio in each surface zone is given by


2.6.2.3
r crit = fct/fy = 0.0035
A2
r = As/(bh’)
h’= depth of surface zone
h’=h/2(h<500mm)
As=0.0035*10^3*100= 350mm2/m
Fig A.1

R/f to control crack spacing

R/f in controlling crack spacing is to be provided according to cl A3


BS8007
A.3
Wmax= smax. R. α (T1+T2)
Let’s take T1= 30’c T2=10’C and α= 10**10^-6/’C
R= 0.5 for rigid end restraints
Wmax/smax = 0.5*10*10^-6(30+10) = 2*10^-4
Smax= fct/fb* (F/2r)
fct/fb = 0.67
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

BS8007 Using 12mm bars and wmax= 0.2mm


2.2.3.3. Smax= 0.67*12/(2r)
Smax= Wmax/(2*10^-4)=1000mm
r = 0.67*6/1000 = 0.004 <rCrit = 0.0035
As = 0.004 *1000*100 = 400mm2/m
This steel has to be provided in both surface zones.

Slab R/F

R/f to carry ULS BM= 1475 mm2/m (At Support only)


R/f to carry out SLS BM = 3680mm2/m (Along short span) at Support
only (top)
R/f to carry out SLS BM = 2950 mm2/m (Along long span) at Support
only (top)
R/f to carry out span BM at other places (Typical) = 811 mm2/m (Bottom
span)

R/f to resist shrinkage and thermal movement = 400 mm2/m each layer
Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya Project No: 001 Date:

Calculated by: Checked


Swimming Pool-Design
by:
CDPGroup-02

Ref Calculations Output

R/f of the Bottom Slab

At Support along short span:Y25 @ 130mm = 3775mm2/m (Top)


At support along long span: Y25 @ 150mm = 3272 mm2/m (Top)
At span along short span: Y12 @130mm = 870mm2/m (Bottom)
At span along long span: Y12 @130 mm = 870mm2/m (Bottom)
Support Bottom long and short span : Y12 @150mm
At Span top short and long span way : Y12 @150mm