Product Lineup
Provided with linear Series Variations Type f40 f50 f63 f80
Unit: mm
f100
pulse encoder Standard type
Main circuit
Main circuit
Standard type……… Carbon steel for machine structural use Output circuit 2.2kΩ 100Ω
Tube material f80 to f100 25 8 Phase A & B
Switch Set ………… Stainless steel diagram Phase A & B
LA・LB・FG・FH・CT LA・FG・FH・CT The cushion stroke lengths in case of cylinders used up GND GND
Mounting style
to the stroke end.
Metallic receptacle
Boots Standard : Nylon tarpaulin Semi-standard : Chloroprene, Conex In the case that a cylinder is not used up to the stroke
end, and it is stopped 5 mm or more before the stroke (+24V)
Accessory Rod eye (T-end), rod clevis (Y-end) with pin, lock nut 1 4
Rod end end, the cushioning effect will be weakened. In this case, Wiring method 1 +12V 3 Phase A
attachment Floating joint (F-end) : Only for 7 MPa type consult us. 2 3 2 GND 4 Phase B
70/140P-8
H H
Phase A Phase A
L L
Output mode H H
Phase B Phase B
L L
±45°
90° ±45°
90°
Phase A advances Phase A delays
90°±45° from phase B. 90°±45° from phase B.
● How to order
Semi-standard
The item enclosed by broken line needs not to be entered, if unnecessary. specification
Sensor List Semi-standard specification
General Purpose Type
l❽
❾
e
y
yle
g
e
pe
pe
Load voltage range Load current range switching capacity Protective
Max.
nt
s
bo
tit
or
Cord length Applicable load
nu
Type Sensor symbol circuit Indicating lamp Wiring method
yp
in
ok
ot
me
st
an
Ty
ty
rb
on
ch
lt
bo
tr
sy
ck
qu
g
od
ta
S
de
in
hi
ea
or
1.5m
Lo
at
AF AX101CE
or
ith
nt
us
R
ns
in
S
ns
nd
ou
None
W
yl
Se
C
de
Se
M
LED
C
5m
Ro
AG AX105CE DC : 5 to 30V DC : 5 to 40mA 0.3mm², 2-core,
(Lights in red
Standard type 140P-8 2 LA 50 B B 100 − − T L − J AH AX111CE AC : 5 to 120V AC : 5 to 20mA DC : 1.5W when sensing) outer dia. f4mm 1.5m
AC : 2VA Provided Rear wiring
AJ AX115CE 5m
Switch Set
Reed sensor
140P-8R 2 LA 50 B B 100 − AH 2 − T L − J
AE AX125CE
DC : 30V or less DC : 40mA or less
None None 5m
AC : 120V or less AD : 20mA or less Small relay,
AK AX11ACE AC : 5 to 120V 5 to 20mA AC : 2VA LED 4-pin 0.5m programmable
Provided (Lights in red connector type controller
AL AX11BCE DC : 5 to 30V 5 to 40mA DC : 1.5W when sensing) Rear wiring 0.5m
Double acting single rod NJN Nylon tarpaulin
LED 0.3mm², 2-core,
For 7 MPa JN Chloroprene AM AX135CE AC/DC : 90 to 240V 5 to 300mA B contact Provided (Lights in red outer dia. f4mm 5m
output when not sensing) Rear wiring
70P-8 :Standard type JK Conex
Neon lamp 0.5mm², 2-core,
70P-8R :Switch Set AC : 80 to 220V 2 to 300mA 30VA Provided (Lights when outer dia. f6mm
S SR405 5m
For 14 MPa not sensing) Rear wiring
140P-8 :Standard type L With lock nut BE AX201CE-1 LED 1.5m
140P-8R :Switch Set (Lights in red 0.3mm², 2-core,
BF AX205CE-1 when sensing) outer dia. f4mm 5m
Double acting double rod LED 1.5m
CE AX211CE-1 Rear wiring
T Rod eye (T-end)
70/140P-8
selection materials. Contact us for longer strokes.
Note) The mounting styles for 7 MPa cannot be used at a pressure exceeding 7 MPa as a rule. Contact us for the usage.
HH HH
34 70/140P-8 7/14 MPa Hydraulic Cylinders with
Position Detector
7/14 MPa Hydraulic Cylinders with
Position Detector 70/140P-8 35
In case that the cushion is not equipped, the AX•AZ type SR405
Bore
cushion valve position is“0” . (mm) Cord length 1.5 m Cord length 5 m Connector type Cord length 5 m
f32 to f50 0.05 0.13 0.04 0.22
f63 0.07 0.14 0.06 0.22
Adaptability of Fluid to Seal Material f80・f100 0.07 0.15 0.06 0.22
Applicable fluid
Calculation formula : Cylinder weight (kg)=basic weight+(additional weight per mm of stroke×cylinder stroke (mm))+
Seal material Petroleum- Water- Phosphate Water in Oil in (sensor additional weight×sensor quantity)+mounting accessory weight+rod end attachment weight
based fluid glycol fluid ester fluid oil fluid water fluid Calculation example : 70P-8R, rod B, bore f50, cylinder stroke 100 mm, mounting style LA, 2 pcs of AX215
8.1+(0.014×100) +(0.05×2) +0.9=10.5kg
1 Nitrile rubber ○ ○ × ○ ○
2 Urethane rubber ◎ × × △ △
3 Fluorocarbon ○ × ○ ○ ○
70/140P-8 Hydraulic Cylinders with Position Detector
70/140P-8
HH HH
36 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Position Indicator with Multi-point Output
7/14 MPa Hydraulic Cylinders with Position Detector
Position Indicator with Multi-point Output 70/140P-8 37
● How to order
Position Indicator
PQCPA Series dedicated Analog input Pulse input
to analog pulse output
s❶
s❶
❸
od
pe
od
pe
rie
rie
th
th
Ty
Ty
position sensing cylinders
me
me
Se
Se
ut
ut
Inp
Inp
Environmentally-friendly lead-free indicator PQCPA − CU − A − A PQCPA − CU − P − 12
Analog input and pulse input types are available.
Provided with multi-point output function (5 points) as
a standard function to enable to individually set the A Current input 12 12V open collector input, 12V voltage input
upper and lower limits Note 1)
V Voltage input 24 24V open collector input, 24V voltage input
A 16-bit AD converter is provided to realize high
00 Differential input
resolution. (Analog input type)
Provided with a counter with a response frequency of Note) Cylinders do not come with indicators of 00
200 kHz (Pulse input type) differential input type. (Specification to use the
Provided with a pulse position correcting function Note 2) indicator in stand-alone state)
Note 1) Setting the bank switching enables to use the CN1 connector CN2 connector
multi-output function of up to 15 points. Display (fluorescent display tube) (for input of measuring sensor signal) (for output of measuring sensor signal)
Note 2) Position correction can be made by mounting a
cylinder sensor. Positional error caused by slippage
of the encoder is eliminated.
Standard Specifications
Type Analog Pulse
Model number PQCPA-CU-A PQCPA-CU-P
Applicable input signals Analog voltage/analog current Phase AB
Display range ±999999 Status indication lamp block (LED) Operation key block CN3 connector CN4 connector
Resolution Stroke×1/10000 − (for control input/output) (for power supply)
Response frequency 1kHz 200kHz Front face Rear face
Linearity ±0.02%FS −
Voltage input 0 to 10V Open collector input Dimensional Drawings Supplied connector
Differential input (line driver input)
Signals Voltage input 1 to 5V
12V voltage input CN1 connector
Current input 4 to 20mA
24V voltage input (for input of measuring sensor signal)
Monitor output Voltage output Note) Line driver output CN1 CN2 CN4
70/140P-8
64 54 60
Display of position Display of position PSR-1A Analog type (1 to 5V) POWER ERROR HOLD
↑ MODE RST
CN4 connector
← →
Bank switching Bank switching 35P-3 CN5 ↓ HOLD SET (for power supply)
Multi-point output Multi-point output 70P-8 Linear pulse encoder Encoder type
Functions 130 1.5 78.5
Positional data hold Positional data hold 140P-8 140
− 0 setting signal Note) For the details of each cylinder, see the section Front view Side view
− Correcting function of each series.
HH HH
38 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Position Indicator with Multi-point Output
7/14 MPa Hydraulic Cylinders with Position Detector
Position Indicator with Multi-point Output 70/140P-8 39
● How to order
How to order cable between sensor and indicator External Input/Output
CN1 CN3
r❷
❸
s❶
th
de
Pin No. Description Signals Pin No. Description Signals
ng
rie
lin
cy
le
Se
1 Voltage/current input Analog input 1 0 setting signal Input
ble
e
bl
ca
Ca
NC − Positional data hold Input
pli
2 2
Ap
3 Voltage/current GND Analog input 3 Correcting function Input
PQCPA − CV1 − 01 4 Phase A Pulse input 4 Bank switching 0 Input
5 −Phase A Pulse input 5 Bank switching 1 Input
6 Phase B Pulse input 6 Bank switching 2 Input
CV1 PTH-1・PTN-1B・PTT-1B 01 1m
7 −Phase B Pulse input 7 Reserved input Input
CV2 35P-3・70P-8・140P-8 05 5m
8 +24V Power supply output 8 Reserved input Input
CV3 PSR-1A 10 10m
9 +12V Power supply output 9 Input common Input
* When ordering a cable, confirm the series name of the actuator on the sensor side. 10 GND Power supply output/Phase AB GND 10 Input common Input
Some models cannot be connected. 11 Multi-point output signal 0 Output
* After wiring, connect the indicator side connector to the CN1 connector on the indicator. CN2 12 Multi-point output signal 1 Output
Pin No. Description Signals 13 Multi-point output signal 2 Output
PQCPA-CV1- Cable length 1 Pout Analog output 14 Multi-point output signal 3 Output
2 Vss Analog output 15 Multi-point output signal 4 Output
Applicable actuators:PTH-1B/PTN-1B/PTT-1B PQCPA-CU-* 3 A pulse Pulse output 16 Reserved output Output
AWG24×2P PQC series control unit PQCPA
4 A pulse GND Pulse output 17 Reserved output Output
5 B pulse Pulse output 18 Reserved output Output
POWER ERROR HOLD
↑ MODE RST
CN5
←
↓
→
HOLD SET
6 B pulse GND Pulse output 19 Output common Output
Cable length (1m, 5m, 10m) 20 Output common Output
CN4 *For details, see the instruction manual.
PQCPA-CV2- Cable length Pin No. Description Signals
1 P24 Power supply
Applicable actuators:35P-3/70P-8/140P-8 2 N24 Power supply
PQCPA-CU-*
AWG24×4C PQC series control unit PQCPA
3 PE Power supply
← →
CN5 ↓ HOLD SET
PQCPA-CV3- Cable length Actuator Cable between sensor and indicator Indicator I/O cable
PQCPA-CU-A-A
Applicable actuators:PSR-1A PQCPA-CU-A-V
2m PQCPA-CU-*
PTH-1B PQCPA-CV1-*
AWG24×2P PQC series control unit PQCPA
PTN-1B
Amplifier PTT-1B CN1 CN2 CN4
CN3
POWER ERROR HOLD
↑ MODE RST
← →
CN5 ↓ HOLD SET
CN1 connector
PQCPA-IO
70/140P-8 Hydraulic Cylinders with Position Detector
Note) PSR-1A comes with a 2-m cable as a standard accessory. If another cable is required, select this
cable. (In this case, disconnect the standard cable (2m) of PSR-1A, and connect the selected cable PQCPA-CU-P-12
directly to the amplifier.) PQCPA-CU-P-24
35P-3 PQCPA-CV2-*
70P-8
How to order I/O cable 140P-8 CN1 CN2 CN4
CN3
PQCPA − IO
CN1 connector
External devices
*The I/O cable is 5m length. (programmable External devices
5m controller, etc.) (programmable
PQCPA-CU-*
PQCPA-CU-A-V controller, etc.)
PQC series control unit PQCPA
70/140P-8
AWG28 PSR-1A PQCPA-CV3-*
POWER ERROR HOLD
↑ MODE RST
← →
CN5 ↓ HOLD SET
CN3
Y0, 3-3
CN3 half-pitch connector CN1 connector
Note) Only the CN3 half-pitch connector is supplied as a standard accessory.
If you need the connector with a cable, place an order for the connector.
HH HH
40 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Double Acting Single Rod/Double Rod Unit: mm
7/14 MPa Hydraulic Cylinders with Position Detector
Unit: mm Double Acting Single Rod/Double Rod 70/140P-8 41
Dimensional Table
SD Symbol Rod B Rod C
70P-8 2 SD Bore B B Stroke BB CS DC DD
Bore A B HP KK MM S SL A B HP KK MM S SL
140P-8 2 SD Bore B B Stroke f 40 30 f 40 84.5 M20×1.5 f22.4 19 11 25 f 36 82 M16×1.5 f18 14 10 11 10 M10×1.25 M10×1.25
10
f 50 35 f 46 87 M24×1.5 f28 24 14 30 f 40 84 M20×1.5 f22.4 19 11 11 10 M10×1.25 M10×1.25
S
f 63 45 f 55 91 M30×1.5 f35.5 30 16 35 f 46 87 M24×1.5 f28 24 14 13 12 M12×1.5 M12×1.5
B
ZJ+stroke f 80 60 f 65 95.5 M39×1.5 f45 41 20 45 f 55 95 M30×1.5 f35.5 30 16 16 16 M16×1.5 M16×1.5
0.5□4-core
shielded cable Y f 100 75 f 80 107.5 M48×1.5 f56 50 23 60 f 65 107.5 M39×1.5 f45 41 20 18 18 M18×1.5 M18×1.5
34 WP A W FP PJ+stroke PL Symbol
SL 2-EE E EE F FF FP G H HL J LZ PJ PL PM TG W WP Y YK ZJ ZK ZM
Bore
24 4-DD f 40 □ 65 RC3/8 11 22 109 50 44 212 36 237 90 13 38 □45 30 87.5 139 60 242 267 297
A
HP f 50 □ 76 RC1/2 13 24 113 54 48 226 40 253 98 15 42 □52 30 92.5 143 60 256 283 313
f 63 □ 90 RC1/2 15 24 121 56 52 238 40 269 102 15 46 □63 35 100 156 66 273 304 339
D B MM
f 80 □ 110 RC3/4 18 30 144 66 54 272 46 310 110 18 56 □80 35 110 179 76 307 345 380
f 100 □ 135 RC3/4 20 32 150 66 60 284 46 324 116 18 58 □102 40 135 190 80 324 364 404
Cushion valves
C KK The tolerance of MM is f8.
TG FF YK G H+stroke J
MM
70/140P-8 Hydraulic Cylinders with Position Detector
Standard Semi-standard
70/140P-8
W The boots have been mounted at our factory
prior to delivery.
Nylon tarpaulin f40 and f50
01/3.5 stroke+X
Chloroprene 〔
f63 to f100 〕
01/4 stroke+X
The heat proof field shows the allowable
temperature limit of the boots.
Conex f40 and f50
01/2.5 stroke+X
〔
f63 to f100 〕
01/3 stroke+X
The values are not the heat proof temperature
of the cylinder body, etc.
If the calculated value has a fractional part, round up the part.
HH HH
42 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Double Acting Single Rod/Double Rod Unit: mm
7/14 MPa Hydraulic Cylinders with Position Detector
Unit: mm Double Acting Single Rod/Double Rod 70/140P-8 43
Dimensional Table
LA Symbol Rod B Rod C
70P-8 2 LA Bore B B Stroke EE F FP LH
Bore A B KK LE MM S SL A B KK LE MM S SL
140P-8 2 LA Bore B B Stroke f 40 30 f 40 M20×1.5 122 f 22.4 19 11 25 f 36 M16×1.5 119.5 f 18 14 10 RC3/8 11 109 37.5±0.15
10
f 50 35 f 46 M24×1.5 132 f 28 24 14 30 f 40 M20×1.5 129 f 22.4 19 11 RC1/2 13 113 45±0.15
S
f 63 45 f 55 M30×1.5 141 f 35.5 30 16 35 f 46 M24×1.5 137 f 28 24 14 RC1/2 15 121 50±0.15
0.5□4-core B
shielded cable f 80 60 f 65 M39×1.5 155.5 f 45 41 20 45 f 55 M30×1.5 155 f 35.5 30 16 RC3/4 18 144 60±0.25
34 WP Max. 7 ZB+stroke f 100 75 f 80 M48×1.5 178.5 f 56 50 23 60 f 65 M39×1.5 178.5 f 45 41 20 RC3/4 20 150 71±0.25
A W FP PJ+stroke
Symbol
SL 2-EE PJ PM SB SS ST SU SV SY TS US W WP XB XR XS Y ZB ZK ZM
24 Bore
A
f 40 90 38 f 11 98 14 31 112 13 95 118 30 87.5 226 128 57 139 253 267 297
LE f 50 98 42 f 14 108 17 34 122 14 115 145 30 92.5 239 131 60 143 267 283 313
D B MM
f 63 102 46 f 18 106 19 32 122 18 132 165 35 100 252 146 71 156 286 304 339
LH
ST
f 80 110 56 f 18 124 25 42 144 18 155 190 35 110 286 162 74 179 323 345 380
KK
C Cushion valves
f 100 116 58 f 22 122 27 38 142 22 190 230 40 135 299 177 85 190 342 364 404
TS 4-SB SY SU SU SY
The tolerance of MM is f8.
US XR SS+stroke
With Boots
XB+stroke
Symbol WW
Drain port 3-Rc1/4 X
Bore Rod B Rod C
When mounting a sensor, refer to the“dimensional drawings of Switch Set”
. f 40 f 50 f 50 45
All the contents other than“sensor mounting dimensions”are the same.
f 50 f 63 f 50 45
Double rod type (both ends loaded) f 63 f 71 f 63 55
ZM+stroke×2 f 80 f 80 f 71 55
ZK+stroke f 100 f 100 f 80 55
W+
Y PJ+stroke PM stroke A
A W 2-EE F
MM
70/140P-8 Hydraulic Cylinders with Position Detector
Standard Semi-standard
70/140P-8
W The boots have been mounted at our factory
prior to delivery.
Nylon tarpaulin f40 and f50
01/3.5 stroke+X
Chloroprene 〔
f63 to f100 〕
01/4 stroke+X
The heat proof field shows the allowable
temperature limit of the boots.
f40 and f50
01/2.5 stroke+X
Conex
〔
f63 to f100 〕
01/3 stroke+X
The values are not the heat proof temperature
of the cylinder body, etc.
If the calculated value has a fractional part, round up the part.
HH HH
44 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Double Acting Single Rod/Double Rod Unit: mm
7/14 MPa Hydraulic Cylinders with Position Detector
Unit: mm Double Acting Single Rod/Double Rod 70/140P-8 45
Dimensional Table
LB For 7 MPa Symbol Rod B Rod C
70P-8 2 LB Bore B B Stroke LB attachment working face (f100)
AB AH AO
Bore A B AE KK MM S SL A B AE KK MM S SL
10 f 40 30 f 40 127.5 M20×1.5 f 22.4 19 11 25 f 36 125 M16×1.5 f 18 14 10 f 11 43±0.15 13
S f 50 35 f 46 137 M24×1.5 f 28 24 14 30 f 40 134 M20×1.5 f 22.4 19 11 f 14 50±0.15 15
24
f 40 8 32 RC3/8 11 109 212 90 38 276 301 46 69 30 87.5 274 139 287 267 297
A
f 50 8 35 RC1/2 13 113 226 98 42 296 323 58 85 30 92.5 291 143 306 283 313
f 63 10 42 RC1/2 15 121 238 102 46 322 353 65 98 35 100 315 156 333 304 339
AE
D B MM f 80 12 50 RC3/4 18 144 272 110 56 372 410 87 118 35 110 357 179 377 345 380
AH f 100 12 55 RC3/4 20 150 284 116 58 394 434 109 150 40 135 379 190 402 364 404
KK
AT Cushion valves The tolerance of MM is f8.
C Drain port
4-AB TR 3-Rc1/4 AU HL+stroke AU With Boots
UA AO SA+stroke AO Symbol WW
X
Bore Rod B Rod C
When mounting a sensor, refer to the“dimensional drawings of Switch Set”
.
All the contents other than“sensor mounting dimensions”are the same. f 40 f 50 f 50 45
f 50 f 63 f 50 45
Double rod type (both ends loaded) f 63 f 71 f 63 55
ZM+stroke×2
f 80 f 80 f 71 55
ZK+stroke
W+
PJ+stroke PM stroke
f 100 f 100 f 80 55
Y A
A W 2-EE F
MM
KK KK
70/140P-8 Hydraulic Cylinders with Position Detector
Standard Semi-standard
70/140P-8
W The boots have been mounted at our factory
prior to delivery.
Nylon tarpaulin f40 and f50
01/3.5 stroke+X
Chloroprene 〔
f63 to f100 〕
01/4 stroke+X
The heat proof field shows the allowable
temperature limit of the boots.
f40 and f50
01/2.5 stroke+X
Conex
〔
f63 to f100 〕
01/3 stroke+X
The values are not the heat proof temperature
of the cylinder body, etc.
If the calculated value has a fractional part, round up the part.
HH HH
46 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Double Acting Single Rod/Double Rod Unit: mm
7/14 MPa Hydraulic Cylinders with Position Detector
Unit: mm Double Acting Single Rod/Double Rod 70/140P-8 47
Dimensional Table
FG Symbol Rod B Rod C
70P-8 2 FG Bore B B Stroke BB EE EF
Bore A B HP KK MM S SL A B HP KK MM S SL
140P-8 2 FG Bore B B Stroke f 40 30 f 40 84.5 M20×1.5 f 22.4 19 11 25 f 36 82 M16×1.5 f 18 14 10 11 RC3/8 72
10
f 50 35 f 46 87 M24×1.5 f 28 24 14 30 f 40 84 M20×1.5 f 22.4 19 11 11 RC1/2 85
S
f 63 45 f 55 91 M30×1.5 f 35.5 30 16 35 f 46 87 M24×1.5 f 28 24 14 13 RC1/2 98
B
0.5□4-core f 80 60 f 65 95.5 M39×1.5 f 45 41 20 45 f 55 95 M30×1.5 f 35.5 30 16 16 RC3/4 118
shielded cable f 100 75 f 80 107.5 M48×1.5 f 56 50 23 60 f 65 107.5 M39×1.5 f 45 41 20 18 RC3/4 150
34 WP Max. 7 A W FP PJ+stroke
SL 2-EE Symbol
F FB FF FP GP GR HG HL LL PJ PM R UG W WP Y ZK ZM ZR
24 Bore
A
f 40 11 f 11 22 109 48 67 115 212 190 90 38 46 139 30 87.5 139 267 297 237
HP
f 50 13 f 14 24 113 58 70 128 226 202 98 42 58 158 30 92.5 143 283 313 253
EF R D B MM f 63 15 f 18 24 121 66 72 138 238 214 102 46 65 172 35 100 156 304 339 269
f 80 18 f 18 30 144 77.5 77.5 155 272 242 110 56 87 190 35 110 179 345 380 310
KK
C Cushion valves f 100 20 f 22 32 150 95 95 190 284 252 116 58 109 230 40 135 190 364 404 324
4-FB GR GP 10 FF LL+stroke BB
The tolerance of MM is f8.
Drain port
HG 3-Rc1/4 HL+stroke
With Boots
UG
Symbol WW
X
When mounting a sensor, refer to the“dimensional drawings of Switch Set”
. Bore Rod B Rod C
All the contents other than“sensor mounting dimensions”are the same. f 40 f 50 f 50 45
f 50 f 63 f 50 45
Double rod type (both ends loaded) f 63 f 71 f 63 55
ZM+stroke×2 f 80 f 80 f 71 55
ZK+stroke f 100 f 100 f 80 55
W+
Y PJ+stroke PM stroke A
A W 2-EE F
MM
70/140P-8 Hydraulic Cylinders with Position Detector
Standard Semi-standard
70/140P-8
W The boots have been mounted at our factory
prior to delivery.
Nylon tarpaulin f40 and f50
01/3.5 stroke+X
Chloroprene 〔
f63 to f100 〕
01/4 stroke+X
The heat proof field shows the allowable
temperature limit of the boots.
f40 and f50
01/2.5 stroke+X
Conex
〔
f63 to f100 〕
01/3 stroke+X
The values are not the heat proof temperature
of the cylinder body, etc.
If the calculated value has a fractional part, round up the part.
HH HH
48 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Double Acting Single Rod Unit: mm
7/14 MPa Hydraulic Cylinders with Position Detector
Unit: mm Double Acting Single Rod 70/140P-8 49
Dimensional Table
FH Symbol Rod B Rod C
70P-8 2 FH Bore B B Stroke EE
Bore A B HP KK MM S SL A B HP KK MM S SL
140P-8 2 FH Bore B B Stroke f 40 30 f 40 84.5 M20×1.5 f 22.4 19 11 25 f 36 82 M16×1.5 f 18 14 10 RC3/8
f 50 35 f 46 87 M24×1.5 f 28 24 14 30 f 40 84 M20×1.5 f 22.4 19 11 RC1/2
f 63 45 f 55 91 M30×1.5 f 35.5 30 16 35 f 46 87 M24×1.5 f 28 24 14 RC1/2
f 80 60 f 65 95.5 M39×1.5 f 45 41 20 45 f 55 95 M30×1.5 f 35.5 30 16 RC3/4
f 100 75 f 80 107.5 M48×1.5 f 56 50 23 60 f 65 107.5 M39×1.5 f 45 41 20 RC3/4
Symbol
10 EF FB FF FP HL PJ R TF UF W WP ZF
S Bore
f 40 72 f 11 22 109 212 90 46 95 118 30 87.5 264
B
f 50 85 f 14 24 113 226 98 58 115 145 30 92.5 280
0.5□4-core f 63 98 f 18 24 121 238 102 65 132 165 35 100 297
shielded cable
f 80 118 f 18 30 144 272 110 87 155 190 35 110 337
A W FP PJ+stroke Max. 7 WP 34
SL 2-EE f 100 150 f 22 32 150 284 116 109 190 230 40 135 356
The tolerance of MM is f8.
24
A
HP
With Boots
Symbol WW
X
MM B D R EF Rod B Rod C
Bore
f 40 f 50 f 50 45
KK
Cushion valves
C f 50 f 63 f 50 45
Drain port HL+stroke FF TF 4-FB f 63 f 71 f 63 55
3-Rc1/4
ZF+stroke UF f 80 f 80 f 71 55
f 100 f 100 f 80 55
70/140P-8
W The boots have been mounted at our factory
prior to delivery.
Nylon tarpaulin f40 and f50
01/3.5 stroke+X
Chloroprene 〔
f63 to f100 〕
01/4 stroke+X
The heat proof field shows the allowable
temperature limit of the boots.
f40 and f50
01/2.5 stroke+X
Conex
〔
f63 to f100 〕
01/3 stroke+X
The values are not the heat proof temperature
of the cylinder body, etc.
If the calculated value has a fractional part, round up the part.
HH HH
50 70/140P-8 7/14 MPa Hydraulic Cylinders with Position Detector
Double Acting Single Rod Unit: mm
7/14 MPa Hydraulic Cylinders with Position Detector
Unit: mm Double Acting Single Rod 70/140P-8 51
Dimensional Table
CT Symbol Rod B Rod C
70P-8 2 CT Bore B B Stroke CD
Bore A B HP KK MM S SL A B HP KK MM S SL
140P-8 2 CT Bore B B Stroke f 40 30 f 40 84.5 M20×1.5 f 22.4 19 11 25 f 36 82 M16×1.5 f 18 14 10 f 16H9
f 50 35 f 46 87 M24×1.5 f 28 24 14 30 f 40 84 M20×1.5 f 22.4 19 11 f 20H9
f 63 45 f 55 91 M30×1.5 f 35.5 30 16 35 f 46 87 M24×1.5 f 28 24 14 f 31.5H9
f 80 60 f 65 95.5 M39×1.5 f 45 41 20 45 f 55 95 M30×1.5 f 35.5 30 16 f 31.5H9
f 100 75 f 80 107.5 M48×1.5 f 56 50 23 60 f 65 107.5 M39×1.5 f 45 41 20 f 40H9
Symbol
10 E EE EW FL FP HL L MR PJ RR W WP XD ZC
S
Bore
f 40 □ 65 RC3/8 25 −0.1
−0.4 38 109 212 R20 R16 90 □ 45 30 87.5 280 296
B 0.5□4-core −0.1
shielded cable
f 50 □ 76 RC1/2 31.5 −0.4 45 113 226 R25 R20 98 □ 52 30 92.5 301 321
−0.1
f 63 □ 90 RC1/2 40 −0.4 63 121 238 R46 R31.5 102 □ 63 35 100 336 367.5
Max. 7 WP 34
−0.1
f 80 □ 110 RC3/4 40 −0.4 72 144 272 R52 R31.5 110 □ 80 35 110 379 410.5
A W FP PJ+stroke
−0.1
SL 2-EE
f 100 □ 135 RC3/4 50 −0.4 84 150 284 R62 R40 116 □ 102 40 135 408 448
The tolerance of MM is f8.
L CD 24
Dimension L indicates the possible radius of swinging.
A
HP
With Boots
MM B D Symbol WW
X
Bore Rod B Rod C
KK MR
Cushion valves C f 40 f 50 f 50 45
HL+stroke FL EW
Drain port f 50 f 63 f 50 45
3-Rc1/4 XD+stroke RR
f 63 f 71 f 63 55
ZC+stroke E
f 80 f 80 f 71 55
f 100 f 100 f 80 55
When mounting a sensor, refer to the“dimensional drawings of Switch Set”
.
All the contents other than“sensor mounting dimensions”are the same.
Dimension L indicates the maximum size of the connecting part.
70/140P-8 Hydraulic Cylinders with Position Detector
70/140P-8
W The boots have been mounted at our factory
prior to delivery.
Nylon tarpaulin f40 and f50
01/3.5 stroke+X
Chloroprene 〔
f63 to f100 〕
01/4 stroke+X
The heat proof field shows the allowable
temperature limit of the boots.
f40 and f50
01/2.5 stroke+X
Conex
〔
f63 to f100 〕
01/3 stroke+X
The values are not the heat proof temperature
of the cylinder body, etc.
If the calculated value has a fractional part, round up the part.
HH HH
52 70/140P-8 7/14 MPa Hydraulic Cylinders with
Position Detector Unit: mm Unit: mm
7/14 MPa Hydraulic Cylinders with
Position Detector 70/140P-8 53
RV RV Indicating lamp f 50
4 to 14 7 to 12 3 to 8
f 63 2 or less 3 or less 1 or less
RY
f 80
f 100 11 to 18 10 to 16 4 to 10
All dimensions of the cylinders are the same as those of the standard type.
70/140P-8 Hydraulic Cylinders with Position Detector
ED KK
LE
CR CE
RYS006T
RA Hex. screw RA Hex. screw
Retainer Retainer
LE LE
ER ER
70/140P-8 Hydraulic Cylinders with Position Detector
70/140P-8
h
operation failure.
KK FR DO NOT use together with CT
accessory.
A FD FN The lock nut is indispensable in using
FQ the floating joint. Please don't miss
FA FC
to order the lock nut with the floating
FJ joint.
HH HH
56 70/140P-8 7/14 MPa Hydraulic Cylinders with
Position Detector Unit: mm Unit: mm
7/14 MPa Hydraulic Cylinders with
Position Detector 70/140P-8 57
Dimensional Table/Retainer
Symbol
Retainer mounting
F G H I J K L
Bore bolt size
f 40 25 14 7 7 14 3 f6.5 M6
f 50 32 18 7.5 7.5 15 4.5 f7 M6
Retainer f 63 32 18 7.5 7.5 15 4.5 f7 M6
f 80 32 18 7.5 7.5 15 4.5 f7 M6
f 100 50 30 10 10 20 6 f10 M8
2-L
Dimensional Table/Lock nut
Symbol Lock nut for rod B Lock nut for rod C
H Part number B C d H Part code B C d H
J
Bore
I f 40 LNH-20F-H 27 31.2 M20×1.5 12 LNH-16F-H 22 25.4 M16×1.5 10
f 50 LNH-24F-H 32 37.0 M24×1.5 14 LNH-20F-H 27 31.2 M20×1.5 12
G
K f 63 LNH-30F-H 41 47.3 M30×1.5 17 LNH-24F-H 32 37.0 M24×1.5 14
F
f 80 LNH-39F-H 55 63.5 M39×1.5 20 LNH-30F-H 41 47.3 M30×1.5 17
f 100 LNH-48F-H 70 80.8 M48×1.5 26 LNH-39F-H 55 63.5 M39×1.5 20
Symbol Dimension A
H B
70/140P-8
The standard fitting length of the rod end attachment and
piston rod is about 80% of the thread diameter. If the
fitting length is insufficient due to the use of the lock nut, it
is necessary to increase the thread length (dimension A) as
shown below. If the length is not specified, the rod will be
manufactured in the standard length.
HH HH
58 35P-3・70/140P-8 Hydraulic Cylinder with Position Detector Hydraulic Cylinder with Position Detector 35P-3・70/140P-8 59
Setting method of sensor detecting position *If another manufacturer’ s amplifier is used,
refer to the following information.
AX type 1. Loosen the two hex. screws with a hex.
counters can normally output signals at two
wrench, and move them along the tie rod. Notes on wiring positions. If more than two preset values are
2. Adjust the detecting position (for the 2-LED
Fit the accessory into required, it is necessary to connect a multi-stage
the middle position of Fix to the bracket with the type, the position where the green lamp Miswiring may damage the internal circuit.
the sensor. Fit from sensor mounting screw M4. programmable counter or a microcomputer.
the direction shown in
lights up) 2 to 5 mm (about half of the When wiring, carefully check the polarity of the
the figure for easier working range is appropriate) before the power supply voltage. Response frequency of pulse counter
fitting.
required position where the sensor indicator If the signal cable is connected to the wiring Select a pulse counter which has a response
lamp starts to light up (ON). Then, gently system of the power line, the cylinder may frequency higher than the following value.
hold the top of the sensor so that the malfunction due to the induced current from
Tie rod size (M6 to M10): Hex. screw M5 cylinder tube contacts the detecting face the power line. Connect the signal cable to Pulse counter response frequency (Hz)=Cylinder speed (mm/s)
[tightening torque: 1 to 2 N・m]
of the sensor, and clamp the hex. screw to another system. ×10 (pulse/mm)×2 (ratio delay)
Tie rod size (M12 to M27): Hex. screw M6
[tightening torque: 2 to 3 N・m] an appropriate tightening torque. If the signal cable length exceeds 30 m,
Tie rod 3. The indicating lamp lights up when the counting error may be caused by the influence Zero-point correction
∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼
Hold with hands. sensor is set to the ON position. of line resistance and line-to-line capacity. To The encoder in the cylinder cannot make zero-point
∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼
Sensor mounting screw M4
(The lamp of SR405 goes out when the also avoid induced noise, lay the cable taking correction. If the power supply is disconnected
[tightening torque: 0.6 to 1 N・m]
sensor turns on.) the shortest route. upon power suspension or after the completion of
4. Sensors can be mounted to any of four tie For wiring, connect 0.5 mm² 4-core shielded operation, the current position will be unknown.
Adjust until the sensor comes in
contact with the cylinder tube.
rods and on the most suitable position wire to the supplied 4-core metallic socket. Therefore, it is necessary to determine the cylinder
(Outer diameter of shielded wire : 6 mm) ∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼
depending on the mounting space of the original position and reset the cylinder to the zero
∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼∼
cylinder and wiring method. point.
∼∼∼∼∼
SR type Hex. screw M4
5. Mount a sensor to the most suitable This will reduce the accumulated error.
[tightening torque: 0.6 to 1.0 N・m] position to detect the stroke end with the
Hold with hands. “switch mounting dimension”(dimension Example of zero-point correction
Tie rod
UX). 1 4 4P Metallic socket
2 3
1/4 in three places of the casing (the lower Encoder assembly and reverse rotations, or forward and backward as it is. GND
output
MAX30mA
one when the cylinder is installed). If the movements. Therefore, if a counter which cannot Check the matching
cylinder is operated with iron particles, discriminate the direction is used, all pulses given between them.
35P-3・70/140P-8
contaminants or dust on the length by the encoder will be added to display the total
measuring roller and the permanent magnet, running distance, and the current position cannot
Selection of solenoid valve
counting error may occur, or the rod may be be determined.
scratched. Use a DC voltage type solenoid valve.
Never install the cylinder with the encoder Preset counter
The stopping accuracy greatly depends on the
positioned down. To stop the cylinder in the middle of the stroke, a response accuracy of the solenoid valve.
preset counter (which outputs a signal when the Generally, DC voltage type solenoid valves have
counter’ s value becomes identical to the set higher repeatability of response speed than AC
value) is necessary. Commercially available preset voltage type ones.
HH HH
60 35P-3・70/140P-8 Hydraulic Cylinder with Position Detector Hydraulic Cylinder with Position Detector 35P-3・70/140P-8 61
Application Examples Multi-point positioning control by analog position control unit (PQCPA) recommended by us
Manual remote operation Combination with the analog position control unit (PQCPA) enables setting of up to 15 stop positions
and ensures multi-functional positioning control.
Even when a cylinder is installed in a concealed place or in the distance and its operations cannot
be directly checked, the counter shows constantly its operations and facilitates position adjustment
and inching.
W
Hydraulic Cylinder with Position
Detector 70/140P-8R
Guide rail Bank switching
Pushbutton A CR2 CR1
Programmable
PQCPA Multi-point output
controller
SOL.1 8F Series Flow
Control Valve
Pushbutton B CR1 CR2
HPC3 Series
SOL.2 Pilot Check Valve
SOL.1 SOL.2
HPC3 Series
Pilot Check Valve
35P-3・70/140P-8
PQCPA
or Hydraulic
M Unit 35HU210
preset counter
Series
System for 2-stage speed control and multi-point positioning control of work
Application example : Multi-stage transfer equipment