Imre Theory Test 10 - 08 - 20

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

IMRE THEORY TEST 10/08/20

MM:50
TIME: 60 MIN

* Required

Email address *

Your email

NAME *

Your answer

ROLL NO *

Your answer

CLASS *

Your answer

SHIFT *

Your answer
Which among the following is not a classification of maintenance? *

corrective maintenance

timely maintenance

scheduled maintenance

preventive maintenance

The following is(are) scheduled maintenance *

Overhauling of machine

Clearing of tank

Whitewashing of building

all of the above

Equipment history cards are meant to record *

the way instrument behaves

total down time of the equipment

the rate at which different components wear off

all of the above

Insulation resistance of a machine can be measured by *

ohmmeter

earth tester

meggar

none
Earth resistance can be measured by *

meggar

earth tester

ohm meter

none

At 150% load relay operating time is *

120 sec

150 sec

180 sec

none

At 120% load relay operating time is *

45 min

50 min

30 min

none

Minimum insulation resistance for complete wiring *

60/no. of outlet

50/no. of outlet

70/no. of outlet

none
minimum insulation resistance for incomplete wiring *

100/no. of outlet

90/no. of outlet

80/no. of outlet

none

Switch is connected in *

phase

neutral

earth

none

Preventive maintenance is used to ensure that breakdowns: *

are eliminated

are reduced

are less costly

cannot happen

Predictive maintenance is used to determine: *

when preventive maintenance was last performed

when preventive maintenance should be performed

when resources should be maintained via preventive maintenance

which resources should be maintained via breakdown maintenance


Faults in rotating electrical machines are: *

electrical fault

mechanical fault

magnetic fault

all of the above

In earth fault____________ *

conductor break

conductor touch to body

fault in bearing

none

In wrong connection induction motor rotate in________ *

reverse direction

right direction

both direction

none

Growler is used for *

open circuit

short circuit

earth fault

none
in single phase induction motor, capacitor is connected in *

phase

neutral

earth

none

D.C motor does not start,when *

low voltage

high load

armature circuit open

all

which motor is generally used in industry *

induction motor

synchronous motor

D.C motor

all

The secondary winding of which of the following transformers is kept closed *

Current transformer

Voltage transformer

Power transformer

Step up transformer
If supply frequency of a transformer increases, the secondary output voltage of
the transformer *

Increases

Decreases

Remains the same

None of the above

The open circuit test in a transformer is used to measure *

copper loss

winding loss

total loss

core loss

Breather is used in a transformer to *

absorb moisture of air during breathing

cooling

heating

none
Transformer core are laminated in order to *

reduce hysteresis loss

reduce eddy current loss

copper loss

none

Bucholz Relay is used to detect *

internal fault

external fault

copper fault

none

The underground system is_____ costly than the equivalent overhead line system
*

more

less

constant

none
If the length of the arc increases , its resistance _____ *

INCREASES

DECREASES

CONSTANT

NONE

Current zero method is used for *

A.C C.B

D.C C.B

BOTH

NONE

The result of electric shock will be certain death if the leakage current is *

50-100mA

8-15mA

15-20mA

20-50mA

5mA current will produce one of the following effect to a human body *

painful shock

severe burn

result in instant death

not so painful
Submit