Grounding Principle 3P-0036C

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Product Information

Description Sign. Date Rev. Document ID


Grounding Principle – Evolution Series Mje 2007-08-23 C 3P-0036C

LIGHTNING ROD

ODU ANTENNA

COAX CONNECTOR

ODU GROUNDING
CABLE 10 sq.mm

COAX CABLE
ODU - IFU

Optional arrangement
SURGE ARRESTOR GROUNDED WALL GLAND PLATE

EQ UIPM EN T R OO M
COAX CONNECTOR COAX CONNECTOR

GROUNDING BUS CABLE 50 sq.m m

COAX CABLE
GROUNDING KIT
10 to 16 sq.mm RACK GROUNDING
CABLE 10 sq.mm

RACK GROUNDING BAR

T
O
W UNIT GROUNDING
CABLE 6 sq.mm
E
R
OD U - IFU
WALL PLATE JUMP ER
S GROUNDING CABLE CA BLE

T 10 to 16 sq.mm
R EVOLUTION IFU
U DC POWER CONNECTION
C TNC- CONNECTOR ODU CABLE
T GR OUND IN G C ONNE CTION
U
MOUNTING HOLES
R
E

STATIO N M AIN
G RO UNDING BAR R ACK FRA ME OTHER RACKS

70 sq.m m
50 sq.mm Insula te d
TOW ER AND SITE EART HING RING
50 sq.mm

EA R TH IN G R O D S

Page 1(1)
Product Information
Description Sign. Date Rev. Document ID
Grounding Principle – Evolution Series Mje 2007-08-23 C 3P-0036C

Lightning Surge Protection - The main important criteria:

1. Evolution ODU and IFU has integrated surge protection circuits at the entrance of coax connectors
2. The ODU must be grounded to tower structure
3. The coax cable ODU-IFU must be grounded to tower structure at the lowest point, on the vertical run in
tower, before the bending towards building.
4. Ensure that all groundings are connected to same network (equal potential)
5. Tower structure must be grounded to a quality site earthing network.

Nera standard installation practice is based on the above criteria and requires no extra protection.

Optional Protection:
Customers may have better knowledge of the status on actual site and may require additional
protection.

1. Surge arrestor at building cable entrance. (Extra set of cable connectors are needed)
2. The wall mounting plate for surge arrestor must be grounded outdoor, to the building / site earthing
network. The wall plate is generally the standard feed-through plate of the building. Hole dimension for
surge arrestor is found on data sheet.

Optional arrangement for surge arrestor:

Surge Arrestor AN-APG-BNFNF-350 (for N-connections only)


Two additional N-connectors, male, straight. (For the actual If cable)
If the cable is AN-CNT-400 (in kit UWMH6506-100/200) the connector code is AN-400APNM-C

Reference documentation:

Surge Arrestors AN-APG-BNFNF-350


Inst. Surge Arrestor 237457
Alternative Mounting Surge Arrestor 237463

Page 2(2)