SingleFix-V Mounting kit - Mounting Instructions EN

SingleFix-V Mounting kit


Mounting Instructions

SingleFix-V mounting kit

Rail piece Solo

End clamp

Middle clamp
Perforated tape

SingleFix-V Solo

Self-drilling screw

Required tools

Power screwdriver with bit and socket holder


Bit TX-drive T40
Socket wrench size 8* Other necessary documents Tightening torques

The Schletter tool kit System structural analysis M8 bolted connections: 15 Nm


contains the tools required for
all standard systems. Calculation documentation with schematic Exception:
diagram, piece list and plant-specific struc- Self-drilling screws: Must be tightened firmly,
tural analysis but must not be overtightened

Safety information

Planning, mounting and putting into operation of the solar plant must be performed by qualified personnel only. Poor quality
execution can result in damage to the plant and to the building and can present a risk to people.

Risk of falling! There is a risk of falling when working on the roof as well as when ascending and descending the building. Accident
prevention regulations must be observed and appropriate safety equipment must be used.

Risk of injury! Objects falling from the roof can cause injury to people. The danger area around the installation site must be sealed
off and people close to this area must be warned.

Risk of breakage! PV modules can be damaged if stepped upon or if handled without care.

Risk of electric shock! The mounting and maintenance of the PV modules must be carried out by qualified
specialists only. Observe the safety regulations issued by the PV module manufacturer! 

*German size

© Schletter GmbH • Gewerbegebiet an der B15 • Alustraße 1 • 83527 Kirchdorf/Haag i. OB • Germany • Tel.: +49 8072 9191-200
Fax: +49 8072 9191-9200 • E-mail: solar@schletter.eu • www.schletter.eu • Updated 12/2013 • Subject to change without notice 1
Your contact in the UK: Schletter UK Limited, Tel.: +44 1296 461 800, Fax: +44 1296 461 801, E-mail: info@schletter.co.uk
SingleFix-V Mounting kit - Mounting Instructions EN

x
 Define the area of installation
• Increase the number of fasteners
in the edge and corner zones. e/10 Corner zone Edge zone Corner zone
e/4
• Further information is given in the
structural analysis.

Edge zone Field zone Edge zone y

e/4
e/10 Corner zone Edge zone Corner zone

e/10 e/10
e/4 e/4

Building h

Calculation formula:
e = min (x resp. y or 2 . h)

 Define the fastening points


• The fastening points are to be defined
so as to facilitate the fastening of
modules in their required positions
(indicated here with a dotted line)
using end and middle clamps.

© Schletter GmbH • Gewerbegebiet an der B15 • Alustraße 1 • 83527 Kirchdorf/Haag i. OB • Germany • Tel.: +49 8072 9191-200
2 Fax: +49 8072 9191-9200 • E-mail: solar@schletter.eu • www.schletter.eu • Updated 12/2013 • Subject to change without notice
Your contact in the UK: Schletter UK Limited, Tel.: +44 1296 461 800, Fax: +44 1296 461 801, E-mail: info@schletter.co.uk
SingleFix-V Mounting kit - Mounting Instructions EN

 Mount the assembly kits


• Twist each of the two SingleFix-V
elements into the lower channel of
the rail piece.
• Align them onto two legs of the
trapezium.
• Put each SingleFix-V element
lengthways and flush onto the leg of
the trapezium and fasten it with two
self-drilling screws1.
• Screws must be drilled slightly in-
clined downwards* and outwards**!

1 Only use screws


with general technical approval:
• Ejot JT3-2-6xL
• Ejot JF3-2-5.5xL
• Ejot JT3-2H Plus-5.5xL
• Reisser RP-T2-6.0xL
Length: 25 mm

Do not overtighten the screws! * **


Tighten each screw until the screw
seal is slightly compressed.

Do not fasten SingleFix at joints of


trapezoidal metal sheets.

Please ensure that SingleFix is mount- about 100° about 100°


ed evenly and flush.

 Create the potential equalization


• Connect the module rows using
perforated metal tape and self-drilling
screws.

© Schletter GmbH • Gewerbegebiet an der B15 • Alustraße 1 • 83527 Kirchdorf/Haag i. OB • Germany • Tel.: +49 8072 9191-200
Fax: +49 8072 9191-9200 • E-mail: solar@schletter.eu • www.schletter.eu • Updated 12/2013 • Subject to change without notice 3
Your contact in the UK: Schletter UK Limited, Tel.: +44 1296 461 800, Fax: +44 1296 461 801, E-mail: info@schletter.co.uk
SingleFix-V Mounting kit - Mounting Instructions EN

 Module mounting
• Position the first module at the ends of
the rails.
• Fasten the module with two end
clamps - in our example: Snap in the
Rapid end clamps and tighten the
screws (TX-drive T40)
• Connect the module cables as required.
• Position further modules and fasten
them between the modules with two
middle clamps each.
• Fasten the last module of the row with
two end clamps.

For further information relating to our systems, please visit our website:
www.schletter.eu and go to the download area.

© Schletter GmbH, 2013, I400247GB, V3

© Schletter GmbH • Gewerbegebiet an der B15 • Alustraße 1 • 83527 Kirchdorf/Haag i. OB • Germany • Tel.: +49 8072 9191-200
4 Fax: +49 8072 9191-9200 • E-mail: solar@schletter.eu • www.schletter.eu • Updated 12/2013 • Subject to change without notice
Your contact in the UK: Schletter UK Limited, Tel.: +44 1296 461 800, Fax: +44 1296 461 801, E-mail: info@schletter.co.uk

You might also like