TEST CERTIFICATE

CERTIFICATE NO. WT/J1401030 PAGE 1 of 1


SERVICE REQUEST NO. J14-26 SERVICE REQUEST DATE 26.09.2014
DATE OF ISSUE 07.10.2014 Sample recd on 01.10.2014
NAME & ADDRESS OF PARTY SAMPLE DETAILS
Sample Particulars :one sample of D.G. Set Stack Emission
M/s
Analysis done on : 01.10.2014 to 06.10.2014
Fleet Gaskets India Pvt Ltd.,
D-50, Okhla Indl. Area, Phase I,
New Delhi -110020 
TEST RESULTS
STACK EMISSION Analysis
Sampling Details:
Source of Emission : DG Emission
Stack Attached to : DG set
Stack Identification :Make: CUMMINS, Sr No. 10367629
DG Capacity : 30 KVA
Date of sampling : 30.09.2014
Sampling Done By : Winmet representative ( Mr Chandan)
Normal operation Schedule, hrs/day : As & when required
Sampling duration (minutes) : 45
Type of stack : Metal/ Circular
Diameter (m) : 0.06
Stack height from Ground Level (m) :-
Stack Height from Roof level (m) : 4 (DG located at roof top)
Height of sampling location from ground level (m) : 2.5 ( from roof )
Type of fuel : H.S.D
Ambient temperature (0C) : 32.5
Stack Temperature (0C) :129
Stack gas Velocity (m/s), Avg : 16.1
Quantity of Emission (Nm3/hr) : 118
Control Measures (if any) : nil
Sample Packing & Marking : plastic bottle & Zip polybag, FG/DG/30

Limit Test Method


S. No. Parameters Unit Results
E(P)A:1986 (max)
1. Particulate Matter ( PM) mg/Nm3 20.4 150 IS: 11255(part 1)

2. Sulphur Dioxide (SO2) mg/Nm3 10.3 - IS: 11255 (pt 2)


3. Oxide of Nitrogen (NOx as NO2) mg/Nm 3
28.5 - IS: 11255 (part 7)
4. Carbon Monoxide (CO) % v/v <0.2 1.0 IS: 13270
5. 3 10.0 CPCB guidelines
Lead (as Pb) mg/Nm <1
REMARKS: For Internal Purpose Only.

Checked By Authorized By

Note 1. The results given above are related to the tested sample, for various parameters, as observed at time of sampling.
The customer asked for the above tests only. Endorsement of product is neither inferred nor implied.
2. The test report will not be used for any publicity/ legal purpose.
3. Sample will be retained for two weeks from the date of issue of test report, unless until specified by the customer.
4. Total liability of our works is limited to invoiced amount.
5. Certificate shall not be reproduced , either wholly or in part, without the written approval of the laboratory.
6. Any sort of play by the customer with the data of this certificate shall be illegal.

You might also like