Professional Documents
Culture Documents
English Catalog 2015
English Catalog 2015
English Catalog 2015
Kind regards,
Layout 20140120
O
Order code:
• CY004: CYANStart
Layout 20140120
Layout 20140120
CYANSmart
C Up to 60 tests/hour
Th CYANSmart is an an easy-to-operate semi-auto-
The Technical Specifications Printer
ma
matic biochemical analyzer. This new in vitro diagnostic • Automatic or on-demand printing
instrument
ins is designed to have powerful features in a Optical system • Built-in thermal printer
com
compact, independent unit. • Flow cell: 32 μl, 10 mm light path • 24 characters per line
• Min. reaction volume: 500 μl per test • Prints graphs
Co
Cost savings: • Halogen lamp 6V/10W
• Minimum reaction volume of 500 μl means decreased • Photo detector: Silicon based (range 300 – 900 nm) Software
costs per test • Measurement range: 0,000 – 3,500 Abs • Memory: 180 test methods and 6000 sample test resultss
• Limited consumables required • Wavelength: 340 – 620 nm • Cypress Diagnostics methods preprogrammed on
• Extra consumables included on delivery (two fuses, five • Wavelength selection: Automatic via 7 interference delivery
paper rolls a spare lamp and pump tube) filters: 340, 405, 492, 510, 546, 578 & 620 nm • Languages: English, French, Spanish
• Integrated incubator, printer, pump, and Flow cell • QC: 2 controls programmable plus a separate QC resultss
• Long life lamp, further extended by power saving / Flow cell menu with (printable) graphs
standby mode • 25°C, 30°C, 37°C, ambient temperature • Calculation methods: absorbance, end point, two-point,
• Robustness of the analyzer with minimal daily • Peltier element kinetic, bichromatic
maintenance • Thermostatic control: PID controlled, ±0,5°C • Calibration methods: factor, calibrator and multi-point
• Analyzer guides the user and so reduces mistakes calibration
Incubator • Blank options: sample blank, reagent blank and water
Flexibility: • 20 places with 14 mm diameter • Incubation time: 0 – 999 seconds
• On-board printer for printing automatically or on • 37°C • Reading time: 3 – 999 seconds
request printing • Thermostatic control: PID controlled, ±1°C
• Seven wavelengths (340, 405, 492, 510, 546, 578, and Power supply
620 nm filters) cover all clinical diagnostic applications Display • AC 110/220 V 50/60 Hz
• Five calculation methods (absorbance, end point, • Back-illuminated LCD • Automatic voltage and frequency switch
two-point, kinetic, bichromatic) and three calibration • Touchscreen calibration possible • Grounding required
methods (factor, calibrator, and multi-point calibration) • 800 x 480 pixels (screen size: 7 inch) • 2 fuses F2AL250V
provide plenty processing options with one system • Power: 200 VA, reduced to 140 VA in standby mode
• Three blank options (sample blank, reagent blank, and • Power save / Standby mode
water) provide background correction of the reagent
and sample coloration Weight and dimensions
• Instrument: 9 kg, 43,5 x 41,5 x 20 cm (H x W x L)
Convenience: • Packed in box: 11,5 kg, 52 x 43 x 26 cm (H x W x L)
• All Cypress Diagnostics biochemistry
iochemistry reagents are
preprogrammed on deliveryy Environm
Environmental requirements
• 180 open channels are programmable
ogr
g ammable to allow for • Ambient
Ambie
Amb ie temperature: 15°C – 30°C
other user-defined tests • Storage
Storag temperature: 5 - 50°C
• Memory for up to 6000 sampleple results
l resullts • Relative
Relativ humidity: 30% - 70%
• Large font size, easily legible
ble and read with
little effort
• LCD touch screen with virtual alphanumeric
uall alph
l hanumeric
i Order code:
Order cod
keyboard • CY009
CY009: CYANSmart
• Multilingual capability
• Minimal daily maintenance
Layout 20140120
Layout 20140120