O o o o o O: Cadman Rack Volt. Test Points

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CADMAN RACK VOLT.

TEST POINTS

TO ACCESS THE TERMINAL STRIP WHERE THE VOLTAGE CAN BE


CHECKED REQUIRES THE LOWER COVER OF THE RACK TO BE
REMOVED.

THE POWER SUPPLY BOARD IS ON THE REAR PANEL OF THE RACK ON


THE LOWER RIGHT SIDE. THE TERMINAL STRIP IS ON THE LEFT SIDE OF
THE BOARD.

0
o V1 +5v RED WIRE
0 vo >\
o vo . Ov (ground) BLACK WIRES
o vo J
o V2 OPEN
o V3 -12v BLUE WIRE
o V4 +12v ORANGE WIRE
0 V5 OPEN

I AM NOT SHOWING THE COMPLETE TERMINAL STRIP, ONLY THE BOTTOM


PART WHERE THE VOLTAGES ARE CHECKED. ALSO THE WIRE COLORS MAY
CHANGE SO GO BY THE "V" NUMBERS WHICH ARE SILK-SCREENED TO THE
BOARD.

ANY QUESTIONS? PLEASE CALL

ROBERT BARR