PRODUCT REPORT

January 1996 Page 1 of 2 A Ba ker Hughes c om pany

FLOW CONTROL SYSTEMS

mum shifting differential. The outer sleeve can be pinned


Model “CMP”™ Non-Elastomeric to open at pressure from 1000 psi to 5500 psi; this varies
Circulating Sliding Sleeve with each size. The sleeves have been designed in four
standard materials: 4140, 9Cr-1 Mo, 13% Cr and Inconel
Product No. 810-81 718 for a wide range of services.
In designing the Model “CMP” Circulating Sliding
DESCRIPTION/APPLICATION: Sleeve, Baker combined several unique features to alle-
viate the seal-related problems that had previously
The Model “CMP” Circulating Sliding Sleeve, is a high- troubled customers and shortened service life.
performance, equalizing sliding sleeve, which allows
communication between the tubing and annulus for cir-
culation or selective zone production. The external FEATURES/BENEFITS:
circulating sliding sleeve allows hydraulic setting of pack-
ers and verifies the seal integrity between the packer and • Allows setting of hydraulic packers with well flanged up
the tubing. After the annulus pressure test is performed, • Allows annulus pressure test to verify packer tubing
tubing pressure shifts the external circulating sleeve seal integrity
downward to the full-open position. This feature allows
you to circulate heavy completion fluids out of the tubing • Allows circulating lighter fluid in tubing string, while
string while the well is flanged up, permitting safer comple- flanged up without the need of a wireline trip
tion of the well and eliminates the need to make a wireline • Eliminates need for wireline work with heavy comple-
trip in the heavy fluid. When desired, the inner sleeve can tion fluid still in tubing string
be shifted open or closed using standard wireline meth-
• Outer sleeve designed not to reclose downhole due to
ods and a "CM" or “B” type shifting tool. A standard Baker
fluid flow
locking profile is included in the upper sub of the sleeve
with a polished seal bore above and below the ports to • Allows circulation of kill fluids with wellhead in place
accept a variety of wireline locks, packing and accesso- prior to releasing packer for safer operation
ries. The nominal working specs on the sleeve, in most • The “CMP” has all the other features/benefits of the
cases are burst, collapse and tensile equal to N-80 “CM” series diffuser ring - seal stack etc.
tubing, 375°F service temperature and 1500 psi maxi-
• Available with Model "F"™, "AF"™, or other profiles

SPECIFICATION GUIDE:
Tubing Size (In.) 2-7/8 3-1/2 3-1/2 4-1/2 4-1/2
(mm ) 73,0 88,9 88,9 114,3 114,3
Seal Bore (In.) 2.31 2.75 2.81 3.43 3.68
(mm ) 58,7 69,9 71,4 87,1 93,6
*Minimum OD (In.) 3.75 5.31 5.31 6.500 6.500
(mm ) 95,2 134,8 134,8 165,1 165,1
Shear Value Brass 1,027 573 573 415 415
per Screw + - 15%
to Open Steel 1,387 773 773 560 560
Outer Sleeve + - 20%
Maximum Brass 4,108 3,438 3,438 3,320 4,150
Do not exceed differential pressure of 5,000
Shear Value + - 15% w/ 4 screws w/ 6 screws w/ 6 screws w/ 8 screws w/ 10 screws psi across outer sleeve before being shifted
with number Steel 5,548 4,638 4,638 4,480 4,480 with tubing pressure. To open and close
inner sleeve, use same shifting tools as the
of Screws + - 20% w/ 4 screws w/ 6 screws w/ 6 screws w/ 8 screws w/ 8 screws standard “CM” series sleeves.
Max Working Temp (°F) 375 375 375 325 325
Notice: Special “CMPA” Sleeve designed
Max Working Pressure (psi) 10,000 10,000 10,000 10,000 10,000 for annulus shear and tubing testing can
be special ordered: “CMPA”,
Tensile Strength (lbs) 140,000 182,000 182,000 270,000 270,000
Product No. 810-81.
*Cannot be turned down below this dimension.


© 1996 Baker Hughes Incorporated. All rights reserved.
PR/FC/96006/3M/1-96
PRODUCT REPORT
January 1996 Page 2 of 2 A Ba ker Hughes c om pany

FLOW CONTROL SYSTEMS

Model “CMP” Circulating Non-Elastomeric Sliding Sleeve (Product No. 810-81)

Designed in four Built-in landing nipple


standard materials Available with Baker F, Sur-
4140, 9Cr-1Mo, 13 Set® AF or most any other
Chrome and Inconel 718. profiles. This profile can be
Compression, burst and used in conjunction with the
tensile properties are lower polished bore to land
compatible with N-80 flow control devices.
tubing. Optional designs
with higher strengths are High performance
available on request. seal system
The CM sleeve is equipped
with a specially configured,
chemically inert seal system
composed of proprietary
Spacing between seals thermoplastic compounds.
and diffuser system is These state-of-the-art seals
critical to the long-term will function in
life of the system. This virtually any environment
allows the flow ports on from 40°F to 375°F.
the closing sleeve to fully
bypass the seals before
equalization occurs. Unique thermoplastic
diffuser ring
This thermoplastic ring
slows the high pressure
rush of fluids over the seal
Self locking threaded stack during shifting.
connection Combined with
Located inside the seal highperformance seal stack,
system, it eliminates the this ring allows the CM
need for elastometric sleeve to be shifted through
thread seals and 25 open and closed cycles
prevents the assembly (50 shifts @ maximum
from backing off temperature and shifting
downhole. differential) without damage.
O-ring and t-seal
configurations in the same
situation last less than 5
cycles.
Equalizing slots
Testing proved that slots Large communication
cause less damage to ports
seals during shifting than The ports are sized to be
equalizing holes. larger than the seal bore
of the sleeve so as not to
restrict the flow of fluids.

High performance coating


Simplified Shifting Metallic components are
and Equalizing coated with a proprietary
Baker’s Model CM surface treatment to
Equalizing tool, run in prevent thread galling and
tandem with a Model B increase the life of the
or a Baker Model CM sleeve. This assures that
Shifting Tool, assures the sleeve will be
proper positioning for redressable in the future
equalization. The Model even when ordered in CRA
CM Equalizing Tool is materials.
used to shift the sleeve
to the equalizing position.
Once equalized the
Model B or Model CM
Shifting Tool is used to
fully open the sleeve.
(The CM Equalizing
Tool is optional and is
not required for seal
protection.)

Run-in Circulate Closed


© 1996 Baker Hughes Incorporated. All rights reserved.
PR/FC/96006/3M/1-96

You might also like