M-Series M-Series

18-141cc3 Industrial Variable Mobile Variable


Vickers PVM Piston Pumps
®
(1.1-8.6in3) Displacement Displacement
Table of
Contents

M Series Variable Displacement Piston Pumps

Principles of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Hydraulic System Design Calculations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Model Code Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Model Code Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Specifications and Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Control Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Performance – Industrial & Mobile
PVM018. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PVM020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
PVM045. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
PVM050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
PVM057. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
PVM063. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
PVM074. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PVM081. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
PVM098. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
PVM106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
PVM131. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
PVM141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Dimensions
PVM018/020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
PVM045/050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PVM057/063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
PVM074/081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
PVM098/106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
PVM131/141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Mounting Flange Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Shaft Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Input Shaft Selection Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Port Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Operating Requirements and Recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Installation and Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

2 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Principles of
Operation

In axial piston pumps, the The displacement of axial Piston Pump Operation
pistons reciprocate parallel piston pumps is determined
to the axis of rotation of the by the size and number of
cylinder block. The simplest pistons, as well as the stroke
type of axial piston pump length which is determined
is the swash plate in-line by the angle of the swash
design. plate.
The cylinder block in this In variable displacement
pump is turned by the drive models of the in-line pump,
shaft. Pistons fitted to bores the swash plate is installed
in the cylinder block are con- in a movable yoke.
nected through piston shoes “Pivoting” the yoke on pin-
and a shoe plate, so that the tles changes the swash plate
shoes bear against an angled angle to increase or decrease
swash plate. the piston stroke.
As the block turns, the pis-
ton shoes follow the swash
plate, causing the pistons to
reciprocate. The ports are
arranged in the valve plate
so that the pistons pass the
inlet as they are pulled out
and pass the outlet as they
are forced back in.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 3
Hydraulic
System Design
Calculations

Basic Formulas Efficiencies


gpm actual
Volumetric Nv =
gpm theorectical
Output Flow (Q)
lb-in actual
Mechanical Nm =
cm3/r x rpm in3/r x rpm lb-in theorectical
lpm = gpm =
1000 231
Total Nt = Nv x Nm
Input Power (P)
Q
l/min x bar gpm x psi
kW = hp = p
600 1714
n
Shaft Torque (M) P
M
bar x cm3/r psi x in3/r
N-m = lb-in =
62.8 6.28

Shaft Speed (n)

1000 x 1/min 231 x gpm


rpm = RPM =
cm3/r in3/r
Commonly Used Conversions
Output Power (P)
To Convert Into Multiply by
N-m x RPM lb-in x rpm bar psi 14.5
kW = hp =
9549 63,025 cm 3
in 3
0.06102
˚C ˚F (˚C x 1.8) +32
Volumetric Displacement
gallons (US) liters 3.785
lpm x 1000 gpm x 231 kg lbs 2.205
cm3/r = in3/r =
rpm rpm kgf/cm2 psi 14.2
kW hp 1.341
liters US Gallons 0.2642
Basic Formulas mm inches 0.03937
bar = 10 Newtons/cm 2
N-m lb-in 8.85
gpm = gallons per minute N-m lb-ft 0.7375
hp = horsepower ˚F ˚C (˚F-32)/1.8
lb-in = pound inch hp kW 0.7457
lb-ft = pound feet inch mm 2.54
kW = kilowatt in
3
cm 3
16.39
kgf = kilograms force lb-in N-m 0.113
l/min = liters per minute lb-ft N-m 1.356
N-m = Newton meters lbs kg 0.4535
psi = pounds per square inch psi bar 0.06896
rpm = revolutions per minute psi kgf/cm 2
.070307

Note: Performance charts can be found on subsequent pages.

4 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Introduction

Eaton Vickers® M Series mobile pumps are open Mounting flanges are offered in SAE and ISO con­fig­
circuit, axial piston designs. A variety of controls urations, and ports are offered in SAE, ISO, and BSPP
provides the ability to match the pumps to each appli- in both tube and flange versions. This provides a
cation. Efficiency of the pump controls allows down- wide variety of installation opportunities for global
sizing of system cooling needs, allowing a smaller machine design.
and less expensive design to be used. Alternatively,
Side- or end-ported models are available to facilitate
cooling capacity could be kept the same and the flow
plumbing and help fit the pump to your machine
capability of the system increased, thus improving
space needs. Multiple drain ports allow many mount-
performance and customer satisfaction.
ing orientations, reducing installed costs.
A strong proven rotating group allows the pumps to
M Series pumps are capable of operating with many
handle pressures to 280 bar (4000 psi) continuous and
types of hydraulic fluids used in industrial and mobile
320 bar (4600 psi) intermittent – with less maintenance
systems. High-water-content and phosphate ester
cost. High-load bearings and a stiff drive shaft help
fluids can be accommodated, in addition to the typical
provide a pump life of 5000 hours at rated mobile
petroleum based and synthetic fluids.
conditions, reducing operating costs and extending
operating life.
M Series pumps feature a saddle-type yoke with
steel-backed polymer bearings. The stiff yoke reduc-
es deflection and allows even loading of bearings, Typical Applications Features and Benefits
improving life. A single control piston reduces load- • Loader backhoes • Long pump life
ing on the yoke, resulting in reduced pump size which • Vibratory cable plows • Quiet pump operation
allows installation in tighter locations. • Mining machinery • Inlet and outlet gauge ports
• Dump truck lifts
and adjustable maximum
M Series pumps operate at a level of quietness that displacement stops –
exceeds the requirements of today’s demanding work • Agriculture tractors standards
conditions. The pumps feature a unique three-piece • Chemical applicator trucks • Astonishingly low 4%
envelope (flange, housing and valve block) specifically • Railroad equipment pressure ripple
created for low fluid-borne and structure-borne noise • Container handling, all-terrain, • Low installed and
levels. Another pump feature – a bimetal timing plate and truck cranes operating costs
– improves pump filling characteristics which, in turn, • Vibratory cable plows • Reduced maintenance
reduce fluid-borne noise and extend pump life. • Mining machinery and tunnel • Flexibility in machine design
boring equipment • Compact size saves space
Proximity of the pump to the vehicle operator
• Utility boom, off-road dump, • Design promotes leak-free
demands a low noise level in the cab. M Series pumps and refuse trucks system
reduce, or in some cases remove, the need for damp-
• Material handling trucks and
ing barriers between the noise source and the opera- rough terrain fork lifts
tor. This saves money on the installed cost of the
• Concrete and asphalt pavers
system while improving customer comfort.
• Feller/bunchers, forwarders,
An adjustable maximum stop provides a means of and log loaders
tuning flow to your system, while gauge ports allow • Crawler dozers
monitoring of inlet and outlet conditions. These stan- • Articulate haulers
dard features reduce system complexity and cost. • Mini-excavators

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 5
Model Code
Selection

PVM 018 M R 01 A E 01 AA A 28 00 00 0 0 A 0 A

1, 2, 3 4, 5, 6 7 8 9,10 11 12 13,14 15,16 17 18,19 20,21 22,23 24 25 26 27 28

Product Series
1, 2, 3 12 Main Port Location 17 Control 22, 23 Torque Limiter Setting
PVM – M Series Variable E** – End Ported 0 – None 00 – None (Not available on
Piston Pump S – Side Ported A – Pressure Compensator M Series)
B – Pressure and Flow
Compensator with Bleed
Displacement
4, 5, 6 13, 14 Main Port Type 24  ompensator Special
C
Orifice
Fourteen displacements SAE & ISO tube ports and Features
C – Pressure and Flow
available 230 bar and 280 bar 4-bolt flange (Other Compensator with 0 – None
continuous ratings configurations optional) Plugged Orifice­
E – Industrial Control (57cc 25 Auxiliary Mounting Pad
7 Valve Plate through 141 cc only) 0*** – None
15, 16 Pump Special Features
M – Mobile Equipment 00 – None (Auxiliary mounting available
Speeds (Higher Speed) AA – Adjustable Maximum 18, 19 Pressure Compensator on all frame sizes)
Displacement Stop and Setting
8 Input Rotation single shaft 00 – None
26 Paint
R – Clockwise (Righthand) (standard) 07 – 70 bar (Adjustable
L* – Counter-clockwise AB – Double Shaft Seal, Two between 40 bar and 0 – No Paint
(Lefthand) Way 130 bar) A – Standard Blue Paint
23 – 230 bar (Adjustable
between 130 bar and 27 Customer Identification
9, 10 Input Shaft 320 bar)
0 – None (Contact Eaton
Standard SAE and ISO splined 28 – 280 bar (Adjustable
for Options)
versions (Other configurations between 130 bar and
optional) 320 bar)
28 Design Code
20, 21 Flow Compensator A – A (Initial Release)
11 Mounting Flange
Setting
Thirteen options in SAE and
00 – None
ISO mounts
11 – 11 bar setting
20 – 20-20 bar setting
24 – 24-24 bar setting

* Not available on 074, 081, 098 and 106 End Port


** Not available on 074, 081, 098 and 106 LH
*** Through drive not available on the LH

6 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Model Code
Options

4,5,6 Maximum geometric displacement

Displacement Code 018 020 045 050 057 063 074 081 098 106 131 141
cm3/r 18,0 21,1 45,1 50,0 57,4 63,1 73,7 81,0 98,3 106,5 131,1 141,0
in3/r 1.1 1.29 2.75 3.05 3.50 3.85 4.50 4.94 6.00 6.50 8.00 8.60

9,10 Shaft-end type at electric motor end

Shaft Code
Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
SAE, SAE A, Straight Keyed 01 – – – – –
SAE, SAE 19-1, Straight Keyed 02 – – – – –
SAE, SAE A, 9T Spline 03 – – – – –
SAE, SAE A, 11T Spline 04 – – – – –
SAE, SAE B, Straight Keyed 05 05 – – – –
SAE, SAE B-B, Straight Keyed 06 06 06 – – –
SAE, SAE B, 13T Spline 07 07 07 – – –
SAE, SAE B-B, 15T Spline 08 08 08 – – –
SAE, SAE C, Straight Keyed – – 09 09 09 09
SAE, SAE C-C, Straight Keyed – – – 10 10 10
SAE, SAE C, 14T Spline – – 11 11 11 11
SAE, SAE C-C, 17T Spline – – – 12 12 12
SAE, SAE D, Straight Keyed – – – – – 13
SAE, SAE D, 13T Spline – – – – – 14
ISO E20N,
Straight Keyed 15 – – – – –
ISO E25N,
Straight Keyed, Short Spigot 16 – – – – –
ISO E25N,
Straight Keyed 17 17 17 – – –
ISO E32N,
Straight Keyed, Short Spigot – – 18 18 18 18
ISO E40N,
Straight Keyed, Short Spigot – – – 19 19 19

11 Mounting flange specifications

Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141


A SAE A, 2-bolt l
B ISO 80A2HW l
C SAE B, 2-bolt l l l
D ISO 100A2HW l l l
E SAE C, 2-bolt l l l l
F ISO 125-A2HW l l l l
G SAE C, 4-bolt l l l l
H ISO 125B4HW l l l l
J SAE D, 4-bolt l
K ISO 160B4HW l
l = Available
= Not Available

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 7
Model Code
Options

13,14 Main Port Options

Inlet
Code Description Outlet PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
Inlet –20 –24 –24 – – –
SAE J1926 (End ports only)
01
Tube Ports Outlet –12 –16 –16 – – –
(End ports only)
SAE J518 Inlet 1.25 inch 2.0 inch 2.0 inch 2.0 inch 2.5 inch 2.5 inch
02
Flange Ports Outlet 0.75 inch 1.0 inch 1.0 inch 1.0 inch 1.0 inch 1.25 inch*
Inlet M42 M48 M48 – – –
ISO 6149-1 (End ports only)
03
Tube Ports Outlet M27 M33 M33 – – –
(End ports only)
ISO 6162 Inlet 32mm 51mm 51mm 51mm 64mm 64mm
04
Flange Ports Outlet 19mm 25mm 25mm 25mm 25mm 32mm*
British Standard
05 Parallel Pipe – Inlet G 1-1/4 G 1-1/2 – – – –
Tube Ports Outlet G 3/4 G 1 – – – –
*SAE Code 62, high pressure series, or ISO 400 bar. Other flange ports are SAE Code 61, standard pressure series, or ISO 25-350 bar.

25 Thru-Drive Options

Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081* PVM098/106 PVM131/141


O Single pump,
non-thru-drive l l l l l l
A SAE A, 2-bolt,
9T spline l l l l l l
B SAE A, 2-bolt,
11T spline l l l l l
C SAE B, 2-/4-bolt,
13T spline l l l l l
D SAE B-B, 2-/4-bolt,
15T spline l l l l l
E SAE C, 2-/4-bolt,
14T spline l l l l
F SAE C-C, 2-/4-bolt,
17T spline l l l
G ISO 80-A2HW,
9T SAE spline l l l l l l
H ISO 80-A2HW,
11T SAE spline l l l l l
J ISO 100-A2/B4HW,
13T SAE spline l l l l l
K ISO 100-A2/B4HW,
15T SAE spline l l l l
L ISO 125-A2/B4HW,
14T SAE spline l l l l
M ISO 125-A2/B4HW,
17T SAE spline l l l
l = Available
= Not Available
* Not available on the 074/081 LH

8 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Specifications
and
Performance
Industrial

Displacement, Pressure and Flow Ratings At 50°C (120°F), SAE 10W oil, 1 bar absolute (0 psig) inlet

Maximum Maximum Flow at 210 bar (3000 psi)


Geometric Maximum Pressure bar (psi) l/min (USgpm)
Displacement @1800 @1500 @1200 @1000
Model Series cm /r (in /r)
3 3
Continuous Intermittent* Peak** r/min r/min r/min r/min
PVM018 18 (1.1) 280 (4000) 320 (4600) 350 (5000) 31 (8.2) 26 (7) 21 (5.5) 17 (4.5)
PVM020 21,1 (1.29) 230 (3300) 250 (3600) 280 (4000) 35 (9) 29 (8) 23 (6) 19 (5)
PVM045 45,1 (2.75) 280 (4000) 320 (4600) 350 (5000) 76 (20) 65 (17) 49 (13) 42 (11)
PVM050 50,0 (3.05) 230 (3300) 250 (3600) 280 (4000) 87 (23) 75 (20) 62 (16) 49 (13)
PVM057 57,4 (3.50) 280 (4000) 320 (4600) 350 (5000) 102 (27) 85 (22.4) 66 (17.4) 54 (14.3)
PVM063 63,1 (3.85) 230 (3300) 250 (3600) 280 (4000) 111 (29) 93 (24) 74 (19) 60 (16)
PVM074 73,7 (4.50) 280 (4000) 320 (4600) 350 (5000) 127 (33.5) 106 (28) 86 (22.7) 70 (18.5)
PVM081 81,0 (4.94) 230 (3300) 250 (3600) 280 (4000) 139 (37) 116 (31) 93 (25) 76 (20)
PVM098 98,3 (6.00) 280 (4000) 320 (4600) 350 (5000) 170 (45) 141 (37) 112 (29.6) 92 (24.3)
PVM106 106,5 (6.50) 230 (3300) 250 (3600) 280 (4000) 187 (49) 155 (41) 123 (32) 102 (27)
PVM131 131,1 (8.00) 280 (4000) 320 (4600) 350 (5000) 215 (57) 178 (47) 141 (37) 118 (31)
PVM141 141,0 (8.60) 230 (3300) 250 (3600) 280 (4000) 238 (63) 199 (53) 158 (42) 131 (35)
**Less than 10% of duty cycle.
**Momentary system pressure spikes only.

Speed, Input Power and Torque Ratings At 50°C (120°F), SAE 10W oil, 1 bar absolute (0 psig) inlet

Maximum
Maximum Torque at
Operating 210 bar Approximate
Model Speed Maximum Input Power at 210 bar (3000 psi) kw (hp) (3000 psi) Weight
Series r/min @1800 r/min @1500 r/min @1200 r/min @ 1000 r/min Nm (lb-ft) kg (lb)
PVM018 1800 16 (22) 13 (18) 11 (15) 9 (12) 84 (62) 15 (33)
PVM020 1800 14 (18) 11 (15) 9 (12) 8 (10) 73 (54) 15 (33)
PVM045 1800 41 (55) 34 (46) 27 (37) 23 (31) 221 (163) 24 (52)
PVM050 1800 35 (47) 30 (40) 28 (38) 23 (31) 190 (140) 24 (52)
PVM057 1800 52 (70) 44 (59) 36 (49) 29 (39) 272 (201) 36 (79)
PVM063 1800 42 (57) 36 (48) 29 (39) 24 (32) 228 (168) 36 (79)
PVM074 1800 63 (84) 52 (70) 42 (56) 35 (47) 334 (246) 45 (99)
PVM081 1800 56 (75) 46 (62) 35 (47) 28 (37) 286 (211) 45 (99)
PVM098 1800 88 (118) 72 (97) 58 (78) 48 (64) 464 (342) 55 (121)
PVM106 1800 72 (97) 60 (80) 48 (64) 40 (54) 383 (282) 55 (121)
PVM131 1800 113 (152) 94 (126) 75 (101) 63 (85) 596 (440) 66 (145)
PVM141 1800 94 (126) 79 (106) 63 (85) 53 (71) 497 (367) 66 (145)

Standard Response Times* Standard Response Times*

Model Series On Stroke (msec) Off Stroke (msec) Model Series On Stroke (msec) Off Stroke (msec)
PVM018 30 25 PVM074 85 30
PVM020 39 26 PVM081 85 30
PVM045 140 40 PVM098 65 25
PVM050 140 40 PVM106 72 29
PVM057 65 20 PVM131 135 30
PVM063 85 20 PVM141 100 30
*Values with pressure compensator control.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 9
Specifications
and
Performance

Mobile

Displacement, Pressure and Flow Ratings At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet

Geometric Maximum Pressure bar (psi) Maximum Flow at 280 bar (4000 psi)
Displacement Flange Ports Tube Ports
Model Series cm3/r (in3/r) Continuous Intermittent* Peak** l/min (USgpm) @ 1 bar inlet l/min (USgpm) @ 1 bar inlet
PVM018 18,0 (1.10) 280 (4000) 320 (4600) 350 (5000) 46 (12) @ 2800 r/min 46 (12) @ 2800 r/min
PVM020 20,1 (1.22) 230 (3300) 250 (3600) 280 (4000) 53 (14) @ 2800 r/min 53 (14) @ 2800 r/min
PVM045 45,1 (2.75) 280 (4000) 320 (4600) 350 (5000) 115 (30) @ 2600 r/min 106 (28) @ 2400 r/min
PVM050 50,0 (3.05) 230 (3300) 250 (3600) 280 (4000) 125 (33) @ 2600 r/min 116 (31) @ 2400 r/min
PVM057 57,4 (3.50) 280 (4000) 320 (4600) 350 (5000) 140 (37) @ 2500 r/min 128 (34) @ 2300 r/min
PVM063 63,1 (3.85) 230 (3300) 250 (3600) 280 (4000) 150 (40) @ 2500 r/min 140 (37) @ 2400 r/min
PVM074 73,7 (4.50) 280 (4000) 320 (4600) 350 (5000) 163 (43) @ 2400 r/min –
PVM081 81,0 (4.94) 230 (3300) 250 (3600) 280 (4000) 181 (48) @ 2400 r/min –
PVM098 98,3 (6.00) 280 (4000) 320 (4600) 350 (5000) 200 (53) @ 2200 r/min –
PVM106 106,5 (6.50) 230 (3300) 250 (3600) 280 (4000) 222 (59) @ 2200 r/min –
PVM131 131,1 (8.00) 280 (4000) 320 (4600) 350 (5000) 233 (62) @ 2000 r/min –
PVM141 141,0 (8.60) 230 (3300) 250 (3600) 280 (4000) 258 (68) @ 2000 r/min –
**Less than 10% of duty cycle.  
**Less than 0.5 second.

Standard Response Times* Standard Response Times*

Model Series On Stroke (msec) Off Stroke (msec) Model Series On Stroke (msec) Off Stroke (msec)
PVM018 50 20 PVM074 95 30
PVM020 57 22 PVM081 135 30
PVM045 140 40 PVM098 85 24
PVM050 140 23 PVM106 90 25
PVM057 65 20 PVM131 100 30
PVM063 94 20 PVM141 128 28
*Values with pressure compensator control.

10 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Specifications
and
Performance

Mobile

Speed, Input Power and Torque Ratings At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet

Minimum Operating Speed and Pressure r/min Max. Input Power at Max. Torque at Approximate
1 bar Inlet 0,85 bar Inlet Max. Speed and 280 bar 280 bar (4000 psi) Weight (dry)
Model Series Flange Ports Tube Ports Flange Ports (4000 psi) kW (hp) Nm (lb-ft) kg (lbs)
2800 r/min 24 (32)
PVM018 2800 r/min 24 (32) 82 (60) 15 (33)
2600 r/min 22 (30)
2800 r/min 21 (28)
PVM020 2800 r/min 21 (28) 72 (53) 15 (33)
2600 r/min 20 (27)
2600 r/min 56 (75)
PVM045 2400 r/min 53 (71) 198 (46) 24 (52)
2200 r/min 48 (64)
2600 r/min 51 (68)
PVM050 2400 r/min 48 (64) 204 (150) 24 (52)
2200 r/min 44 (59)
2500 r/min 68 (91)
PVM057 2300 r/min 62 (83) 262 (193) 36 (79)
2100 r/min 56 (75)
2500 r/min 59 (79)
PVM063 2400 r/min 57 (76) 225 (166) 36 (79)
2200 r/min 52 (69)
2400 r/min 84 (113)
PVM074 334 (246) 45 (99)
1900 r/min 69 (93)
2400 r/min 69 (93)
PVM081 276 (204) 45 (99)
1900 r/min 55 (74)
2200 r/min 105 (141)
PVM098 457 (337) 55 (121)
1800 r/min 86 (115)
2200 r/min 87 (117)
PVM106 377 (278) 55 (121)
1800 r/min 70 (94)
2000 r/min 122 (164)
PVM131 581 (429) 66 (145)
1600 r/min 98 (131)
2000 r/min 102 (137)
PVM141 483 (356) 66 (145)
1600 r/min 81 (109)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 11
Control Options

See model code on page


Pressure Compensator See model code on page xx for
spring (pressure) adjustm
Control – Code A spring (pressure) adjustment ranges.
“B” inlet
The pump will provide a continu-
ously modulated flow to meet “B” inlet
“F” case drain
changing load demands at a pre- • •
adjusted compensator pressure. “F” case drain
At pressures below the • •
“K” inlet •
compensator setting, the pump gage port
will operate at maximum “K” inlet •
gage port
displacement. See model code
on page 4 for compensator pres-
sure ranges.
Warning: The pressure compen-
sator may be adjusted beyond

the rated pressure of the pump.
When adjusting the pressure • •
“K” outlet •
limiter, install a 0-350 bar gage port
(0-5000 psi) gage in the outlet “K” outlet •
gage port and limit the pressure gage port
setting to the continuous rated “C” outlet
pressure for the pump displace- “C” outlet
ment shown on page 7. To load
To load
Pressure Cut-off Characteristics of
Pressure Cut-off Characteristics of Code A Pressure Compensator Control
Code A Pressure Compensator Control @ 50°C (120°F), 1800 r/min, static conditions
@ 50ϒC (120ϒF), 1800 r/min, static conditions
Industrial Pressure Cut-off Change in
Characteristics of Code
Change in A Pressure A
Pressure Compensator
Pressure A Q
Control at 50°C (120°F), static
Q conditions. Change
Outlet Flow

in Flow B
Change
Outlet Flow

in Flow B

Outlet Pressure P
P
Outlet Pressure Pressure Cut-off Characteristics of Pressure Compensator Control @ 50°C (120°F), static conditions

“P” Outlet
Max. Speed “Q” Outlet Flow Pressure A B
Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)
PVM018 1800 32 (8.5) 280 (4000) 2,8 (40) 4,5 (1.2)
PVM020 1800 35 (9.25) 230 (3300) 2,8 (40) 4,5 (1.2)
PVM045 1800 76 (20) 280 (4000) 10 (150) 4,5 (1.2)
PVM050 1800 87 (23) 230 (3300) 10 (150) 4,5 (1.2)
PVM057 1800 102 (27) 280 (4000) 3,5 (51) 14 (3.7)
PVM063 1800 113 (29) 230 (3300) 7,4 (107) 7,6 (2.00)
PVM074 1800 127 (33.5) 280 (4000) 1,5 (22) 37 (9.8)
PVM081 1800 141 (37) 230 (3300) 1,5 (22) 37 (9.8)
PVM098 1800 179 (47) 280 (4000) 1,5 (22) 25 (6.6)
PVM106 1800 195 (51.5) 230 (3300) 1,5 (22) 20 (5.3)
PVM131 1800 229 (60.5) 280 (4000) 3,5 (51) 19 (5.0)
PVM141 1800 238 (63) 230 (3300) 3,5 (51) 14 (3.70)

12 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009

Control Options “K” outlet •

+
gage port

“C” outlet

To load

Mobil Pressure Cut-off


Characteristics of Pressure Change in
Compensator Control at Pressure A
93°C (200°F), static conditions.
Q

Outlet Flow Change


in Flow B

Outlet Pressure P

Pressure Cut-off Characteristics of Pressure Compensator Control @ 93°C (200°F), static conditions

“P” Outlet
Rated Speed “Q” Outlet Flow Pressure A B
Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)
PVM018 2800 42 (11) 280 (4000) 2,8 (40) 4,5 (1.2)
PVM020 2800 52 (14) 230 (3300) 2,8 (41) 4,5 (1.2)
PVM045 2600 115 (30) 280 (4000) 10 (150) 4,5 (1.2)
PVM050 2600 125 (33) 230 (3300) 10 (150) 4,5 (1.2)
PVM057 2500 140 (37) 280 (4000) 3,5 (50) 14 (3.7)
PVM063 2500 159 (42) 230 (3300) 7,4 (107) 11,4 (3.00)
PVM074 2400 174 (46) 280 (4000) 1,5 (20) 37 (9.8)
PVM081 2400 185 (49) 230 (3300) 1,5 (22) 37 (9.8)
PVM098 2200 217 (57) 280 (4000) 1,5 (20) 32 (8.4)
PVM106 2200 234 (62) 230 (3300) 1,5 (22) 24 (6.33)
PVM131 2000 253 (67) 280 (4000) 1,0 (15) 23 (6.0)
PVM141 2000 258 (68) 230 (3300) 7,0 (100) 14 (3.70)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 13
Control Options

Load Sensing and Pressure


Compensator Control – Optional bleed-down orifice in Code B
Code B or C control. ∅ 0,4 mm (.016 in.) Orifice is plugged
The pump will provide power for no bleed down in control Code C.
matching of pump output to
system load demand, maximiz- “B” inlet
ing efficiency and improving load
metering characteristics of any
directional control valve installed “F” case drain
• • •
between the pump and the load.
Load sensing ensures that the
pump always provides only the “K” inlet • •
amount of flow needed by the “J” load
gage port sense
load. At the same time, the
pump operating pressure adjusts signal
to the actual load pressure plus
port
a pressure differential required
for the control action. When
the system is not demanding
power, the load sense control
will operate in an energy-saving • • •
stand-by mode. “K” outlet
gage port • •
Typically, the differential pres-
sure is that between the pres-
sure inlet and service port of a “C” outlet
proportionally controlled direc-
tional valve, or a load sensing To load
directional control valve. See
the model code on page 4 for
differential pressure settings for
load sensing.
If the load pressure exceeds
the system pressure setting,
the pressure compensator de-
strokes the pump. The load
sensing line must be as short as
possible and can also be used
for remote control or unload-
ing of the pump pressure. For
remote control purposes, it is
recommended that you contact
your Eaton representative for
the correct configuration of the
control.
Warning: The pressure com­
pensator may be adjusted
beyond the rated pressure of
the pump. When adjusting the
pressure limiter, install a
0-350 bar (0-5000 psi) gage
in the outlet gage port and
limit the pressure setting to the
continuous rated pressure for
the pump displacement shown
on page 7.

14 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Control Options

Industrial Control
Compensator – Code E & F
(Model 057-141 only)

This pump is intended for use With Pressure & Flow Compensator (E)
when multiple, remote, or elec-
tronically controlled compensat- Inlet
ing settings, with or without
load sensing, are desired.
Pressure compensation is Case drain
obtained when an internal plug
is removed, the load-sense Pressure
port
signal port is kept plugged, and
internal pilot pressure is applied Inlet Tank port
to the spring chamber of the
control spool. For pressure
compensation with load sensing, Case drain
the internal plug stays, the load-
sense signal port is unplugged, Pressure
and pilot pressure is externally port
applied.
Tank port
An external relief valve (not
supplied) controls spring cham-
ber pressure. The externally Outlet Load sense
adjustable spring determines signal port
the differential pressure setting To load
of the control. Outlet pressure
is limited to the valve of the
spring chamber (pressure port)
pressure, plus control differential Inlet
pressure. Outlet Load sense
Spring chamber (pilot) pres- signal port
sure is separated from outlet Case drain
To load
pressure by an internal orifice.
Pressure Compensating Without Load Sensing (F) Pressure
Outlet pressure shifts the spool
port
when pressure drop across the
orifice reaches the differential Inlet Tank port
pressure setting, and the pump
de-strokes.
Case drain
The relief valve can be mounted
to an NFPA-D03/ISO 4401-03
Pressure
pad on the pump control, or port
remotely located via tapping and
blanking plates installed on the Tank port
pad. See “Ordering Procedure”,
page 27, for more on valves and
plates. Outlet Load sense
The standard factory-set dif- signal port
ferential pressure setting of To load
the pump control is 20 bar (290
psi) and is not specified in the
pump model number. Any other
ordered differential pressure,
within the control’s adjustable Outlet Load sense
pressure range of 17-35 bar signal port
(247-508 psi), will be specified in To load
the model number.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 15
Performance

Industrial
PVM018

Typical Noise Levels at 1800 and 1200 r/min with


Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
66
Typical Noise Levels at 1800 and 1200 r/min with
1800 r/min
64 Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar Delivery and Efficiency at 1800 r/min
max. flow
absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
62
66 100 Delivery and Efficiency at 1800 r/min
50°C Volumetric
(120°F) andEfficiency
1.0 bar absolute (0 psi gauge) Inlet
60
64 1800 r/min 100
90
max. flow Overall Efficiency
Volumetric Efficiency
58
62 90
Level – dBA

80
Overall Efficiency
60
56 80
70
1200 r/min

–%–%
54
58 max. flow 70
60
– dBA

Efficiency
Noise

52
56 60
50 40 (11)

(USgpm)
Noise Level

1200 r/min
Efficiency
50
54 max. flow 50
40 40 (11)

(USgpm)
Delivery (effective flow) 30 (8)
1200 r/min
52 1800 r/min
48 min. flow 40
30

– l/min
min. flow Delivery (effective flow) 30 (8)
20 (5)
50
46 30
20

– l/min
0 50 100 150 200 250 300 350 20 (5)

Delivery
(700) 1200 r/min
(1500) (2200) (2900) (3600) (4400) (5000) 20 10 (3)
1800 r/min
48 pressure data min. flow 10
Sound min. flow

Delivery
equivalent to NFPA. Outlet Pressure – bar (psi) 10 (3)
46 10
0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 (700) (1500) (2200) (2900) (3600) (4400) (5000)
0
Sound pressure data 0 50 Outlet
100 Pressure
150 200 – bar250
(psi) 300 350
equivalent to NFPA. Outlet Pressure – bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

Input Torque and Power at 1800 r/min


Typical Noise Levels at 1500 and 1000 r/min with 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar 100 (885) Input Torque and Power at 1800 r/min
absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
62 100
90 (885)
(796) Input Torque,
Typical Noise Levels at 1500 and 1000 r/min with Full Stroke
60 Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar 90
80 (796)
(708) Input Torque,
Full Stroke
Nm (in-lb)

1500 r/minabsolute (0 psi gauge) Inlet


58
62 max. flow 80
70 (708)
(619)
– Nm– (in-lb)

56
60 70
60 (619)
(531)
1500
1000r/min
r/min 60
50 (531)
(442)
54
Torque

58 max.
Level – dBA

max.flow
flow Input Power,
kW (hp)

50
40 (442)
(354) Full Stroke 20 (27)
Torque

52
56
Input Power,
InputInput

– kW–(hp)

40
30 (354)
(265) Full Stroke 20
54 1000
50 r/min (27)
15 (20)
– dBA

max. flow
Noise

30
20 (265)
(177) 15
10 (20)
(13)
Power

52
48
1500 r/min
Noise Level

min. flow 20
10(177)
(88)
Input Torque, 10 (13)
5 (7)
Power

50
46
InputInput

10 (88) Cut-off
1000 r/min 0 5
0 (7)
44
48 50 100 150 200 250 Input 300
Torque,
350
1500 r/min min. flow 0 Cut-off
min. flow 0 (700) (1500)(2200)(2900)(3600) (4400)(5000)
0
42
46 0 50 Outlet
100 Pressure
150 200– bar250
(psi) 300 350
0 50 100 150 200 250 300 350 (700) (1500)(2200)(2900)(3600)(4400)(5000)
1000 r/min
(700) (1500) (2200) (2900) (3600) (4400) (5000)
44 min. flow Outlet Pressure – bar (psi)
42 Outlet Pressure – bar (psi)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
16 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM018

Delivery and Efficiency at 1500 r/min Delivery and Efficiency at 1200 r/min
50°C (120° F) and 1.0Efficiency
bar absolute (0 psir/min
gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery and at 1500 100 Delivery and Efficiency at 1200 r/min
100
50°C (120° F) and 1.0 bar
Volumetric Efficiency absolute (0 psi gauge) Inlet 50°C (120°F) and
Volumetric 1.0 bar absolute (0 psi gauge) Inlet
Efficiency
100
90 100
90
Volumetric EfficiencyOverall Efficiency Volumetric EfficiencyOverall Efficiency
90
80 Overall Efficiency 90
80 Overall Efficiency
80
70 80
70
– %– %

– %– %
70
60 70
60
Efficiency

Efficiency
60
50 60
50

(USgpm)
Efficiency

(USgpm)
Efficiency
50 50
40

(USgpm)
40

(USgpm)
40 40
30 30 (8)
30 Delivery (effective flow) 30 (8) – l/min

– l/min
Delivery (effective flow)
30 Delivery (effective flow) 30 (5)
(8) 30
20 30 (5)
20 (8)
– l/min

20 20

– l/min
Delivery (effective flow)
Delivery

20 20 (3)
(5) 20 20 (3)
(5)

Delivery
10 10 10 10
Delivery

Delivery
10 10 (3) 10
0 10 (3)
0
0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
0 0
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 0
(700) (1500) (2200) (2900) (3600) (4400) (5000)
0 50 100
Outlet 150 200– bar250
Pressure (psi) 300 350 0 50 100 Pressure
Outlet 150 200 – bar 250
(psi) 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0and
bar Power
absolute 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque at (0 psi r/min
1500 gauge) Inlet
100 (885) 100 (885) Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (885) 100 (885) Input Torque,
90 (796) 90 (796) Full Stroke
Input Torque, Input Torque,
90 (796)
80 (708) Full Stroke 90 (796)
80 (708) Full Stroke
(in.lb.)

Input Torque,
(in.lb.)

80 (619)
(708) Full Stroke
80 (619)
(708)
(in.lb.)

70 70
(in.lb.)
– Nm

70 (531)
(619) 70 (531)
(619)
– Nm

60 60
– Nm
Torque

– Nm

60 (442)
50 (531) 60 (442)
50 (531)
Torque
(hp)(hp)
Torque

50
40 (442)
kW (hp)
50 (354)
40 (442) 20 (27)
(354) Input Power, 20 (27)
Torque
Input

– kW

Full Stroke 20 (27) Input Power, 20 (27) – kW– (hp)


InputInput

40 (265)
30 (354) Input Power, 15 (20) 40 (265)
30 (354) 15 (20)
Input

Full Stroke
– kW

Full Stroke Input Power,


Power

30 (177)
(265) 15 (13)
(20) 30 (177)
20 (265) 15 (20)
Full Stroke 10 (13)
Power

20 10
Power

20
10(177) 510(7)
(13) 20
10(177) 10(7)
(13)
Power

(88) (88) 5
Input

InputInput

10 (88) 05 (7) 10 (88)


0 5 (7)
Input

0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
0 0
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 (700) (1500)(2200)(2900)(3600)(4400)(5000)
0
0 50 100 150 200
Outlet Pressure – bar250
(psi) 300 350 0 50 Outlet
100 Pressure
150 200– bar 250
(psi)300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500)(2200)(2900)(3600)(4400)(5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 17
Performance

Industrial
PVM018

Delivery and Efficiency at 1000 r/min Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
50°C (120°F) and
Delivery and1.0Efficiency
bar absolute (0 psir/min
at 1000 gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 1,4 Flow
(0.37) Versus Outlet Pressure at 1800 r/min, Full Flow
Volumetric Efficiency Case
100
90 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency Overall Efficiency 1,2(0.37)
(0.32)
1,4

Case Flow – l/min (USgpm)


90
80 Overall Efficiency
80 1,0(0.32)
1,2 (0.26)

Case Flow – l/min (USgpm)


70
– %– %

70
60 0,8(0.26)
1,0 (0.21)
Efficiency

60

(USgpm)
50
Efficiency

0,6(0.21)
0,8 (0.16)
50
40 (USgpm)
40
30 0,4
0,6 (0.11)
(0.16)
– l/min

30
– l/min

20 Delivery (effective flow) 20 (5) 0,2(0.11)


(0.05)
0,4
Delivery

20 Delivery (effective flow) 20


10 10 (5)
(3)
Delivery

0,2 (0.05) 0
10 10
0 0 (3) 0 50 100 150 200 250 300 350
0 50 100 150 200 250 300 350 (700) (1500) (2200) (2900) (3600) (4400) (5000)
0 0
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0
0 50 100 150 200
Outlet Pressure – bar250
(psi) 300 350 0 50 Outlet Pressure
100 150 200 – bar250
(psi) 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
Input Torque and Power at 1000 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
100 (885) Input Torque and Power at 1000 r/min Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
5 (1.32)
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90 (885)
(796) Input Torque,
Full Stroke 5 (1.32)
90 Input Torque,
80 (796) 4 (1.06)
Case Flow – l/min (USgpm)

(708)
(in.lb.)

Full Stroke
80
70 (708)
(in.lb.)

(619) 4 (1.06)
Case Flow – l/min (USgpm)
– Nm

70 3 (0.79)
60 (619)
(531)
– Nm
to0rque

60
50 (531)
(442) 3 (0.79)
2 (0.53)
(hp)(hp)
to0rque

50
40 (442)
(354) 20 (27)
Input

– kW

40 2 (0.53)
30 (354)
(265) 20 (27)
Input Power, 15 (20) 1 (0.26)
Input

– kW
Power

30 Full Stroke
20 (265)
(177) Input Power, 15
10 (20)
(13)
Power

Full Stroke 1 (0.26)


2010(177)
(88) 10 (13) 0
5 (7)
Input

0 50 100 150 200 250 300 350


10 (88)0 50 (7) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Input

0 50 100 150 200 250 300 350 0


0 0 0 50 Outlet 150
100 Pressure
200– bar (psi) 300 350
250
(700) (1500) (2200) (2900) (3600) (4400) (5000)
0 50 100Outlet 150Pressure
200 250 300 350
– bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

18 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM018

Typical Noise Levels Delivery


Deliveryand andCase
CaseFlow
FlowVersus
VersusSpeed
Speed
Petroleum Oil (10W) at 93°C (200°F), @@ 93°C (200°F), full flow and 1.0 bar absolute(0(0psi)
93°C (200°F), full flow and 1.0 bar absolute psi)gauge
gaugeInlet
Inlet
1.0 barTypical
absoluteNoise
(0 psiLevels
gauge) Inlet 50 (13.2)
50 (13.2)
Petroleum
(Sound Oil (10W)
pressure at 93°C (200°F),
data equivalent to NFPA)
1.0 bar absolute (0 psi gauge) Inlet 45
76
(Sound 45(11.9)
(11.9) 25
25bar
bar(365
(365psi),
psi),
2800 r/min pressure data equivalent to NFPA) Delivery
76 Max. Flow 40 Delivery
72 40(10.6)
(10.6)
2800 r/min

(USgpm)
Max. Flow

l/min(USgpm)
72
68 35
35(9.2)
(9.2)
250
250bar
bar(3600
(3600psi),
psi),
68 30
30(7.9)
(7.9) Delivery
– dBA

64 Delivery

(USgpm)
l/min(USgpm)
Delivery––l/min
25
25(5.3)
– dBA

64 2800 r/min (5.3)


60
LevelLevel

Min. Flow 20 (5.3)


2800 r/min 20 (5.3) 4,0
4,0(1.1)
(1.1)
60
Delivery
56 Min. Flow

Flow––l/min
15
15(4.0)
Noise

600 r/min (4.0) 3,0


3,0(.8)
(.8)
56 250
52 Max. Flow 250bar
bar(3600
(3600psi),
psi),Case
Caseflow
flow
Noise

600 r/min 10
10(2.6) 2,0 (.5)

CaseFlow
Max. Flow (2.6) 2,0 (.5)
52
48 55(1.3) 1,0
(1.3) 1,0(.3)
(.3)

Case
25
25bar
bar(365
(365psi),
psi),Case
Caseflow
flow
48 600 r/min
44 Min. Flow 00 00
600 r/min
00 500
500 1000
1000 1500
1500 2000
2000 2500
2500 3000
3000
44 Speed
40 Min. Flow Speed––r/min
r/min
50 0 100 150 200 250 300 350
(700) (1500)(2200) (2900) (3600) (4400) (5000)
40
50 Outlet
0 100 Pressure
150 200 250 300 350
– bar (psi)
(700) (1500)(2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
Overall Efficiency Versus Speed Input
InputTorque
TorqueVersus
VersusSpeed
Speed
95
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet @@ 93°C (200°F), full flow and 1.0bar
93°C (200°F), full flow and 1.0 barabsolute
absolute(0(0psi
psigauge)
gauge)inlet
inlet
95 110 (973)
110 (973)
100
100(885)
(885) 320
90 320bar
bar(4600
(4600psi)
psi)
90
90(796)
(796)
90 280
100 bar 280bar
bar(4000
(4000psi)
(in.lb.)

psi)
Nm(in.lb.)

(1500 psi) 80
80(708)
– %– %

(708) 250 bar (3600 psi)


85 150100 bar 250 bar (3600 psi)
bar
(1500 psi) 70
70(619)
Efficiency

(2200 psi) (619)


Torque––Nm

85 150 bar 200


200 psi)
bar 60 (531) 200bar
bar(2900
(2900psi)
psi)
60 (531)
Efficiency

(2200
80 (2900 psi)
InputTorque

200 bar 50
50(442) 150
(442) 150bar
bar(2200
(2200psi)
psi)
80 (2900 psi)
250 bar 40
40(354)
(354)
(3600 psi) 100
100bar
bar(1500
(1500psi)
Input

75 250 bar psi)


30 (265)
30 (265)
280 psi)
(3600 bar
75 (4000 psi) 20
280 bar320 bar 20(177)
(177)
(4000 psi)(4600 psi) 25
25bar
bar(365
(365psi)
psi)
70 320 bar 10
10(88)
(88)
0 500 (4600
1000
psi) 1500 2000 2500 3000
70 Speed – r/min 00
0 500 1000 1500 2000 2500 3000 00 500
500 1000
1000 1500
1500 2000 2500 3000
2000 2500 3000
Speed – r/min Speed
Speed––r/min
r/min

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 19
Performance

Mobile
PVM018

Input Power Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
28 (37.5)
Input Power Versus Speed 320 bar
26 inlet
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) (34.9) (4600 psi)
28 (37.5) 24 (32.2) 280 bar

Input Power @ Full Flow – kW (hp)


320 bar (4000 psi)
26 (34.9) 22 (29.5) (4600 psi)
Input Power @ Full Flow – kW (hp)

250 bar
24 (32.2) 20 (26.8) 280 bar (3600 psi)
(4000 psi)
22 (29.5) 18 (24.1) 200 bar
250 bar (2900 psi)
20 (26.8) 16 (21.4) (3600 psi)
14 (18.8)
18 (24.1) 200 bar 150 bar
12 (16.1) (2900 psi) (2200 psi)
16 (21.4)
10 (13.4) 100 bar
14 (18.8) 150 bar
8 (10.7) (1500 psi)
12 (16.1) (2200 psi)
6 (8.0)
10 (13.4) 100 bar
4 (5.4) 25 bar
8 (10.7) (1500 psi)
2 (2.7) (365 psi)
6 (8.0) 0
0 500 1000 1500 2000 2500 3000
4 (5.4) Speed – r/min
25 bar
2 (2.7) (365 psi)
0 Input Torque and Case Flow Versus Speed
0 500 1000 1500 2000 2500 3000
@ 93°C (200°F), load sense standby
Speed – r/min and 1.0 bar absolute (0 psi gauge) inlet
3 (27)
Input Torque - Nm (in.lb.)

Case Flow (l/min (USgpm)


Input Torque and Case Flow Versus Speed Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby @ 93°C (200°F), cut-off and 1.0 bar absolute
and 1.0 bar absolute (0 psi gauge) inlet (0 psi gauge) inlet
3 (27) 2 (18)
50 (442)
20 bar (300 psi) 280 bar (4000 psi)
Input Torque - Nm (in.lb.)

45 (398)
Case Flow (l/min (USgpm)

Input Torque – Nm (in.lb.)

differential, Input Torque 20 bar (300 psi)


Input Torque
40 (354) differential,
2 (18) 1 (9)
35 (310) Case Flow 5 (1.32)
11 bar (160 psi) 4 (1.06)
20 bar (300 psi) 30 (265)
differential, 3 (0.79)
differential, Input Torque 11 bar (160 psi) 2 (0.53)
Input Torque 20 bar (300 psi) 25 (221) differential, 1 (0.26)
differential, 150 bar (2200 psi) Case Flow
1 (9) Case Flow 5 (1.32) 020 (177) Input Torque 0
11 bar (160 psi) 4 (1.06) 0 500 1000 1500 2000 2500 3000
15 (135) Speed – r/min 9 (2.4)
differential, 3 (0.79) 280 bar (4000 psi), Case Flow
Input Torque 11 bar (160 psi) 2 (0.53) 10 (88) 6 (1.6)
differential, 1 (0.26)
0 Case Flow 5 (45) 150 bar (2200 psi) 3 (0.8)
0
0 500 1000 1500 2000 2500 3000 0 Case Flow 0
Speed – r/min 0 500 1000 1500 2000 2500
Speed – r/min

20 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM020

Delivery and Efficiency at 1800 r/min, 50°C (120°F),


Typical Noise Levels at 1800 and 1200 r/min and 1.0 bar absolute (0 psi gauge) Inlet
with Petroleum Oil (10W) at 50°C (120°F) Delivery and Efficiency at 1800 r/min, 50°C (120°F),
100
and 1.0 bar absolute (0 psi gauge) Inlet 1
and 1.0 barEfficiency
Volumetric absolute (0 psi gauge) Inlet
64 Typical Noise Levels at 1800 and 1200 r/min 100
90 1
1800 r/min Overall Efficiency
Volumetric Efficiency
62 with Petroleum
Max. Flow Oil (10W) at 50°C (120°F)
90
80
and 1.0 bar absolute (0 psi gauge) Inlet Overall Efficiency
60
64 80
70
1800 r/min
1200 r/min
58
62

–%–%

–%–%
Max. Flow
Max. Flow 70
60
Level – dBA

56
60

Efficiency

Efficiency
60
50

(USgpm)
54 1200 r/min 50 (13)
58

Efficiency

Efficiency
Max. Flow
50

(USgpm)
52 40 50
40 (13)
(11)
– dBA

56
1800 r/min
50
54 40 Delivery (effective flow) 40
30 (11)
Noise

30 (8)

– l/min
Min. Flow
Noise Level

48
52 30 Delivery (effective flow) 30
20 (8)

– l/min
20 (5)
46 1800 r/min

Delivery
50 Min. Flow 20
10 20
10 (5)
(3)
44

Delivery
48
1200 r/min 10
0 0 (3)
10
42
46 Min. Flow 0 50 100 150 200 250
40 0 (700) (1500) (2200) (2900) (3600) 0
44 0 50 100 150 200 250 0 50 100
Outlet Pressure –150
bar (psi)200 250
42 (700) (1500) (2200)1200(2900)r/min (3600) (700) (1500) (2200) (2900) (3600)
Outlet Pressure – barMin.
(psi)Flow Outlet Pressure – bar (psi)
40
0 Typical50
Noise Levels
100 at 1500
150 and 1000
200 r/min250
with(700)
Petroleum Oil (10W)
(1500) at 50°C(2900)
(2200) (120°F) (3600)
and 1.0Outlet Pressure(0–psi
bar absolute bargauge)
(psi) Inlet
64 Typical Noise Levels at 1500 and 1000 r/min
62 with Petroleum Oil (10W) at 50°C (120°F) Input Torque and Power at 1800 r/min, 50°C (120°F),
1500 r/min
and 1.0 bar absolute (0 psi gauge) Inlet and 1.0 bar absolute (0 psi gauge) Inlet
60
64 Max. Flow Input Torque and Power at 1800 r/min, 50°C (120°F),
120 (1062)
and 1.0 bar absolute (0 psi gauge) Inlet
58
62 110(1062)
(973)
1500 r/min 120
56
60 Max.1000
Flowr/min 100 (973)
(885)
110
Level – dBA

54 Max. Flow
Nm (in.lb.)

58 90 (885)
100 (796)
52 80 (796)
(708)
– Nm– (in.lb.)

56 1000 r/min 90
– dBA

50
54 Max. Flow 70 (708)
80 (619)
Noise

1500 r/min Input Torque,


48
52 60 (531)
70 (619) kW (hp)
torque
Noise Level

Min. Flow Full Stroke


50 (531)
(442) Input Torque, 25 (34)
– kW–(hp)
46
50 60
torque

Full Stroke 20
1500 r/min 1000 r/min 40 (442)
50 (354) 25 (27)
(34)
InputInput

44
48 Input Power,
Min. Flow
Power

Min. Flow 30 (354)


(265) 15 (20)
42 40 Full Stroke 20 (27)
46 Input Power,
Power

20 (265)
30 (177) Input Torque, 10
15 (13)
(20)
40 1000 r/min Full Stroke
InputInput

44 0 50 100 150 200 250 Cut off


Min. Flow 2010(177)
(88) 5 (7)
(700) (1500) (2200) (2900) (3600) Input Torque, 10 (13)
42 0 0
Outlet Pressure – bar (psi) 10 (88) Cut off 5 (7)
40 0 50 100 150 200 250
Sound
0 pressure
50 data
100 150 200 250 0 (700) (1500) (2200) (2900) (3600) 0
equivalent to NFPA
(700) (1500) (2200) (2900) (3600) 0 50 100 150 200 250
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi) (700) (1500) (2200) (2900) (3600)
Sound pressure data Outlet Pressure – bar (psi)
equivalent to NFPA

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 21
Performance

Industrial
PVM020

Delivery and Efficiency at 1500 r/min, 50°C (120°F),


and 1.0 bar absolute (0 psi gauge) Inlet Delivery Deliver
Delivery and Efficiency at 1500 r/min, 50°C (120°F), Deliveryand
andEfficiency
Efficiencyatat1200
1200r/min,
r/min,50°C
50°C(120°F),
(120°F), Delive
100 and 1.0Efficiency
bar absolute (0 psi gauge) Inlet and
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet a
Volumetric 100
100 100 100
100
90 Volumetric
VolumetricEfficiency
Efficiency V
Volumetric Efficiency
Overall Efficiency 9090 9090
80 90 Overall
Overall Efficiency OverallEfficiency
Efficiency
8080 8080
70 80
Efficiency – %

7070 7070
60 70

Efficiency – %
Efficiency – %

Efficiency – %
Efficiency – %
Efficiency – %

6060 6060

Delivery – l/min (USgpm)


50 60 50 (13)

Delivery – l/min (USgpm)


Delivery – l/min (USgpm)
5050 5050(13)
(13) 5050
Delivery – l/min (USgpm)

Delivery – l/min (USgpm)


40 50 40 50
(11)(13)
4040 4040(11)
(11) 4040
30 40 30 40
(8)(11)
Delivery (effective flow) 3030 3030(8) 3030
(8)
20 30 20 30
(5)(8)
Delivery (effective flow)
2020 Delivery 2020(5) 2020
10 20 10 20
(3)(5) Delivery(effective
(effectiveflow)
flow) (5)
1010 1010(3)
(3) 1010
0 10 0 10 (3)
0 50 100 150 200 250 00 00
0 (700) (1500) (2200) (2900) (3600)0 00 5050 100
100 150
150 200
200 250
250 00
0 50 100
Outlet Pressure – 150
bar (psi) 200 250 (700)
(700) (1500)
(1500) (2200)
(2200) (2900)
(2900) (3600)
(3600)
(700) (1500) (2200) (2900) (3600)
Outlet
OutletPressure
Pressure– –bar
bar(psi)
(psi)
Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min, 50°C (120°F), Input


InputTorque
Torqueand
andPower
Poweratat1200
1200r/min,
r/min,50°C
50°C(120°F),
(120°F), InI
and 1.0 bar absolute (0 psi gauge) Inlet and
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet
Input Torque and Power at 1500 r/min, 50°C (120°F),
120 (1062) and 1.0 bar absolute (0 psi gauge) Inlet 120
120(1062)
(1062) 120
12
110
120(973)
(1062) 110
110(973)
(973) 111
100110
(885)
(973) 100 (885)
100 (885) 101

Input torque – Nm (in.lb.)


Input torque – Nm (in.lb.)

Input torque – Nm (in.lb.)


Input torque – Nm (in.lb.)

9090(796) 9
Input torque – Nm (in.lb.)

90100
(796)
(885) (796)
8080(708)
(708) 8
Input torque – Nm (in.lb.)

80 90
(708)
(796)
70 80
(619) 7070(619)
(619) 7
(708)
Input Torque, 6060(531) Input
InputTorque,
Torque, 6
Input Power – kW (hp)

60 70
(531) (531)
Input Power – kW (hp)
(619)
Input Power – kW (hp)
Full Stroke Full
FullStroke
Stroke
Input Torque, 25 (34) 5050(442)
(442) 2525(34)
(34) 5
50 60
(442)
Input Power – kW (hp)
Input Power – kW (hp)

(531)
Full Stroke 4040(354)
(354) 2020(27)
(27) 4
40 50
(354)
(442) 20 25
(27)
(34) Input
InputPower,
Power, 1515(20)
3030(265)
(265) Full (20) 3
30 40
(265)
(354) Input Power, 15 20
(20)
(27) FullStroke
Stroke
Full Stroke 2020(177)
(177) 1010(13)
(13) 2
20 30
(177)
(265) Input Power, 10 15
(13)
(20)
Full Stroke 1010(88)
(88) 5 5(7)
(7)
1020(88)
(177) 5 (7)
10 (13)
00 00
0
10 (88) 0 5 (7) 00 5050 100 100 150
150 200
200 250
250
0 50 100 150 200 250 (700)
0
(700) (1500) (2200) (2900) (3600)0 (700)(1500)
(1500)(2200) (2900)(3600)
(2200)(2900) (3600)
0 50 100 150 200 250 Outlet
Outlet Pressure OutletPressure
Pressure– –bar
bar(psi)
(psi)
(700) (1500)–(2200)
bar (psi)
(2900) (3600)
Outlet Pressure – bar (psi)

22 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM020

Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,


, Delivery and and
Delivery Efficiency at 1000
Efficiency r/min,
at 1000 50°C50°C
r/min, (120°F),
(120°F), Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
and and
1.0 bar
1.0 absolute (0 psi
bar absolute (0gauge) InletInlet
psi gauge) 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
2.5 (0.66)
100 100 2.5 (0.66)
Volumetric Efficiency
Volumetric Efficiency 2.3 (0.59)
90 90 2.3 (0.59)
Overall Efficiency
Overall Efficiency 2.0 (0.53)

(USgpm)
2.0 (0.53)

l/min– –(USgpm)
80 80
1.8 (0.46)
70 70 1.8 (0.46)
Efficiency – %
Efficiency – %

1.5 (0.40)
60 60 1.5 (0.40)

Flowl/min
1.3 (0.33)
Delivery – l/min (USgpm)

Delivery – l/min (USgpm)


Delivery – l/min (USgpm)

Delivery – l/min (USgpm)


(13) 50 50 50 (13)
50 (13) 1.3 (0.33)

CaseFlow
(11) 40 40 40 (11)
40 (11) 1.0 (0.26)
1.0 (0.26)
0.8 (0.20)

Case
(8) 30 30 30 (8)
30 (8) 0.8 (0.20)
(5) 20 20 20 (5)
20 (5) 0.5 (0.13)
Delivery (effective flow)flow) 0.5 (0.13)
Delivery (effective
(3) 10 10 10 (3)
10 (3) 0.3 (0.07)
0.3 (0.07)
0 0 0 0
0 0 0 50 50 100 100 150 150 200 200 250 250 00 50 100 150 200 250
(700)(700)
(1500)
(1500)(2200)
(2200)(2900) (3600)
(2900) (3600) 0 50
(700) 100
(1500) 150
(2200) 200
(2900) 250
(3600)
(700) (1500) (2200) (2900) (3600)
Outlet Pressure
Outlet – bar–(psi)
Pressure bar (psi) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

°F), InputInput
Torque and and
Torque Power at 1000
Power r/min,
at 1000 50°C50°C
r/min, (120°F),
(120°F), Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
and and
1.0 bar
1.0 absolute (0 psi
bar absolute (0gauge) InletInlet
psi gauge) 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
120 (1062)
120 (1062)
10 (2.64)
110 (973)
110 (973) 10 (2.64)
9 (2.38)
100 (885)
100 (885) 9 (2.38)
Input torque – Nm (in.lb.)

(USgpm)
Input torque – Nm (in.lb.)

90 (796)
90 (796) 8 (2.11)
l/min– –(USgpm)

8 (2.11)
80 (708)
80 (708) 7 (1.85)
7 (1.85)
70 (619)
70 (619) 6 (1.59)
60 (531) InputInput
Torque,
Torque, 6 (1.59)
60 (531)
Input Power – kW (hp)
Input Power – kW (hp)

Flowl/min
Input Power – kW (hp)
Input Power – kW (hp)

Full Stroke
Full Stroke 5 (1.32)
5) (34) 50 (442)
50 (442) 25 (34)
25 (34) 5 (1.32)
CaseFlow

0) (27) 40 (354)
40 (354) 20 (27)
20 (27) 4 (1.06)
4 (1.06)
5) (20) 30 (265)
30 (265) InputInput
Power,
Power, 15 (20)
15 (20) 3 (0.79)
Case

Full Stroke 3 (0.79)


0) (13) 20 (177)
20 (177) Full Stroke 10 (13)
10 (13) 2 (0.53)
10 (88) 5 (7)5 (7) 2 (0.53)
(7) 10 (88)
0 0 1 (0.26)
0 0 1 (0.26)
0 0 50 50100 100150 150200 200250 250 0
) (700)(700)
(1500) (2200)
(1500) (2900)
(2200) (3600)
(2900) (3600) 00 50 100 150 200 250
0 50
(700) 100
(1500) 150
(2200) 200
(2900) 250
(3600)
Outlet Pressure
Outlet – bar–(psi)
Pressure bar (psi) (700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 23
Performance

Mobile
PVM020

Typical
Typical
Noise
Noise
Levels
Levels
at at
2800
2800 &&600
600
r/min
r/min
with
withPetroleum
PetroleumOilOil
(10W)
(10W)
at at
93°C
93°C
(200°F)
(200°F)
and
and 1.01.0
bar
bar
absolute
absolute
(0 (0
psi
psi
gauge)
gauge)Inlet
Inlet
7777
2800
2800
r/minTypical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
r/min
7474 max.
max.
flow
flow at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
7171 77
2800 r/min
6868 74 max. flow
2800
2800r/min
r/min
min.
min.
flow
flow
Noise Level – dBA
Noise Level – dBA

6565 71
6262 68 2800 r/min
min. flow
5959

Noise Level – dBA


65
5656
62
5353
59
5050 600
600
r/min
r/min
4747 max.
max.flowflow56
600
600r/min
r/min
53 min.
min.flow
flow
4444
50 600 r/min
4141 max. flow
00 5050 100 47
100 150150 200
200600
250 r/min
250
min. flow
Sound
Soundpressure
pressure data(700)
data (700) (1500)
(1500) 44 (2200)
(2200) (2900)
(2900)
(3600)
(3600)
equivalent
equivalent
to to
NFPA.
NFPA. Outlet
OutletPressure
Pressure
– bar
– bar
(psi)
(psi)
41
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.

Overall
OverallEfficiency
Efficiency versus
versus Speed
Speed Delivery
Delivery andand
Case
Case Flow
Flowversus
versus Speed
Speed at at
93°C
93°C(200°F),
(200°F),
at at
93°C
93°C
(200°F)
(200°F)and
and1.01.0
bar
barabsolute
absolute (0 (0
psi
psi
gauge)
gauge) inlet
inlet Full
Full Flow
Flow1.01.0
bar
bar
absolute
absolute (0 (0
psipsi
gauge)
gauge) inlet
inlet
100
100 6060(15.9)
(15.9)

Case Flow – l/min (USgpm)


Case Flow – l/min (USgpm)
Overall Efficiency
55 55 (14.5)versus Speed
(14.5) Delivery and Case Flow v
9595 at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar abs
150150bar
bar
(2200
(2200psi)
psi) 100 5050(13.2)
(13.2) 60 (15.9)
9090 210
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)

210bar
bar
(3000
(3000psi)
psi) 4545
(11.9)
(11.9)
95 55 (14.5)
5050
bar bar
(725
(725
Overall Efficiency (%)
Overall Efficiency (%)

8585 100
100
barbar
(1500
(1500psi)
psi) 40150
40 bar
(10.6)
(10.6) psi)
psi)
Delivery
Delivery
(2200 psi) 50 (13.2)
90 35 35
(9.2)
(9.2)
Delivery – l/min (USgpm)

8080 210 bar (3000 psi) 45 (11.9)


5050barbar
(700
(700psi)
psi) 210
210bar
bar(3000
(3000 50 b
30 30
(7.9)
(7.9)
Overall Efficiency (%)

7575 85 100 bar (1500 psi) psi)


Delivery40 (10.6)
Delivery psi)
230
230barbar
(3300
(3300psi)
psi) 2525
(6.6)
(6.6) 35 (9.2)
7070 80
20
5020
(5.3)
(5.3)(700 psi)
bar 44
30 (7.9) (1.06)
(1.06)
6565 75
1515
(4.0)
(4.0) 33 (0.79)
(0.79)
230 bar (3300 psi) 25 (6.6)
6060 70 1010
(2.6)
(2.6) 210
210
bar bar
(3000
(3000 psi)
psi)
Case
Case Flow
Flow
20 22
(5.3) (0.53)
(0.53)
65 5 (1.3)
5 (1.3)
5555 5050
bar
bar(725
(725
psi)
psi)
Case
CaseFlow 15 (4.0)
Flow 11 (0.26)
(0.26)
60 10 (2.6) 0 0 210 b
5050
00 500
500 1000 1000 1500 1500 2000 2000 2500 2500 3000 3000 0 0 500 500 1000
10001500 1500200020002500 25003000 3000
55 5 (1.3) 50 bar
Speed
Speed – r/min
– r/min Speed
Speed (r/min)
(r/min)
50
0 500 1000 1500 2000 2500 3000 0 500 1000
Speed – r/min S

24 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM020

InputTorque
Input Torqueversus
versusSpeed
Speedat at93°C
93°C(200°F),
(200°F), InputPower
Input Powerversus
versusSpeed
Speedat at93°C
93°C(200°F),
(200°F),
FullFlow
Full
Input Flow
Torque and
and 1.0
1.0 bar
bar
versus absolute
absolute
Speed at (0
(0
93°C psi
psi gauge)
gauge)
(200°F),
Input Torque versus Speed at 93°C (200°F), Inlet
Inlet Full
Full
Input Flow
FlowPower
Input and
and 1.0
1.0
versus
Power bar
bar absolute
absolute
Speed
versus at
Speed (0
(0
93°Catpsi
psi gauge)
gauge)
(200°F),
93°C Inlet
Inlet
(200°F),
Full Flow
Full and
Flow1.0 bar
and absolute
1.0 (0 psi (0
bar absolute gauge) Inlet Inlet Full Flow
psi gauge) Full andFlow1.0 bar
and absolute
1.0 (0 psi (0
bar absolute gauge) Inlet Inlet
psi gauge)
110(973)
110 (973) 24(32)
24 (32)
110 (973)
110 (973) 230bar
230 bar(3300
(3300psi)
psi)
100(885)
100 (885) 24 (32)24 (32)
22(30)
22 (30) 230 bar 230(3300 psi) psi)
bar (3300
100 (885)
100 (885) 2220(30)22 (30)
90(796)
90 (796) 20(27)
(27)
(lb.in.)
Nm (lb.in.)

210bar
210 bar(3000
(3000psi)
psi)
90 (796)
90 (796) 230bar
230 bar(3300
(3300psi)psi) 20 (27) 20 (27)

(hp)
kW (hp)
Input Torque – Nm (lb.in.)

18(24)
18 (24)
Input Torque – Nm (lb.in.)

80(708)
80 (708) 210 bar (3000
210 bar psi) psi)
(3000
230 bar (3300
230 psi) psi)
bar (3300

Input Power – kW (hp)

Input Power – kW (hp)


80 (708)
80 (708) 1816(24)18
16(21)
(21) (24)
– Nm

– kW
70(619)
70 (619)
210bar
210 bar(3000
(3000psi)
psi) 1614(21)16 (21)
70 (619)
70 (619) 14(19)
(19)
Torque –

Power –
60(531)
60 (531) 210 bar (3000
210 psi) psi)
bar (3000 150bar
150 bar(2200
(2200psi)
psi)
Input Torque

Input Power
150bar
150 bar(2200
(2200psi)
psi) 1412(19)14
12(16)
(16) (19)
60 (531)
60 (531) 150 bar (2200
150 bar psi) psi)
(2200
50(442)
50 (442) 150 bar 150(2200 psi) psi) 12 (16)
bar (2200 12
(13)(16)
10(13)
10
50 (442)
50 (442) 100bar
100 bar(1500
(1500psi)
psi)
100bar
100 bar(1500
(1500psi)
psi)

Input
40(354)
40 (354)
Input

10 (13) 10
88(11)
(11) (13)
40 (354)
40 (354) 100 bar
100(1500
bar psi)
(1500 psi) 100 bar (1500
100 bar psi)
(1500 psi)
30(265)
30 (265) 8 (11) 8(8)(11)
50bar
50 bar(725
(725psi)
psi) 66 (8)
30 (265)
30 (265)
20(177)
20 (177) 50 bar50 (725 psi) 6 (8)
44(5) 6 (8)
(5) 50bar
50 bar(725
(725psi)
psi)
bar (725 psi)
20 (177)
20 (177) 4 (5) 4 (5) 50 bar (725
50 barpsi)
(725 psi)
10(88)
10 (88) 22(3) (3)
10 (88) 10 (88) 2 (3) 02 (3)
00 0
0 00 0 500
500 1000
1000 1500
1500 2000
2000 2500
2500 3000
3000 0 00 500500 1000
1000 15001500 2000
2000 2500 2500 3000
3000
0
0 500
0 1000 1000
500 1500 2000
1500
Speed(r/min)
Speed (r/min) 2500
2000 3000
2500 3000 0 500
0 1000
500 1500
1000 2000
1500
Speed(r/min)
Speed (r/min) 2500
2000 3000
2500 3000
SpeedSpeed
(r/min)(r/min) Speed (r/min)
Speed (r/min)

InputTorque
Input Torqueand andCaseCaseFlow FlowversusversusSpeed Speedat at InputTorque
Input Torqueand andCase
CaseFlow Flowversus
versusSpeed
Speed
93°C
93°C
Input (200°F),
(200°F),
Torque and Load
Load Case Sense
Sense
Flow Standby
Standby
versus
Input Torque and Case Flow versus Speed at and
and
Speed 1.0
1.0at bar
bar at93°C
at
Input 93°C (200°F), Pressure Limit
Input Torque and Case Flow versusand
Torque(200°F),
and Pressure
Case Flow Limit
versus Cut-off
Cut-off
Speed and
Speed
93°C (200°F), absolute
absolute
Load Load
93°C (200°F), (0
Sense(0psi
psi gauge)
gauge)
Standby
Sense Inlet1.0
Inlet
and
Standby and bar 1.0 bar at 93°C 1.0
1.0
at barabsolute
bar
(200°F),
93°C absolute
Pressure
(200°F), (0psi
(0 psi
PressureLimitgauge)
gauge)
Cut-off
Limit Inlet
Inlet
and and
Cut-off
(28)absolute
3.2(28)
3.2 absolute(0 psi (0gauge)
psi gauge)Inlet Inlet 3030(265)1.0 bar
(265) absolute
1.0 (0 psi (0
bar absolute gauge) Inlet Inlet
psi gauge)
3.23.0
(28)
3.0 (27)(28)
(27)
3.2 30 (265)
30 (265)
2727(239)
(239) 210bar
210 bar(3000
(3000psi)
psi)
2.8
3.02.8
(27) (25)(27)
(25)
(lb.in.)
Nm (lb.in.)

3.0
(lb.in.)
Nm (lb.in.)

20bar
20 bar (290
(290psi)psi)diff.
diff. 27 (239)
27 (239) 210 Input
Input
bar Torque
Torque
(3000 psi)
2.82.6
(25)
2.6(23)
(23)(25)
2.8 2424(212)
(212) 210 bar (3000 psi)
Input Torque – Nm (lb.in.)

Input Torque – Nm (lb.in.)

Input
20Input Torque
Torque
Input Torque – Nm (lb.in.)

Input Torque – Nm (lb.in.)

bar 20(290
bar psi)
(290 diff.
psi) diff. 24 (212) Input Torque
Input Torque
2.62.4
(23)
2.4 2.6
(21)(23) Input Torque
(21) 24 (212)
Input Torque 2121(186)
(186)
– Nm
– Nm

2.42.2
(21)
2.2 2.4
(19)(21)
(19) 21 (186)
21 (186)
Torque –

22(18)
2.2 (19) (18)(19)
2.2 11bar
11 bar (160
(160psi) psi)diff.
diff. 1818(159)
(159)
Torque –

Input Torque
Input Torque

1.8(16)
21.8
(18) (16)
2 (18) Input
11 Input
bar 11 Torque
Torque
(160
barpsi)(160 diff.
psi) diff. 18 (159)
18 (159)
1.81.6
(16)
1.6 (14)(16)
(14)
1.8 Input Torque CaseFlow
Case Flow 1515(133)
(133) Case
Case
Input Torque 150barbar
Case l/minl/min
Flow
Case Flow 15 (133)
15 (133)150 Flowl/min
Flow l/min
1.61.4
(14)
1.4 (12)(14)
(12)
1.6 Case Case
Input

(USgpm)
(USgpm)
l/min 1212(106)
(106)150 (2200
(2200 psi)
150psi)
bar bar
Input

1.2
1.41.2
(12) (11)(12)
(11) l/min Flow (USgpm)
(USgpm)
l/min
Flow l/min
1.4 (USgpm) 12 (106) Input
Input
(2200
12 (106) Torque
Torque
psi)
(2200 psi)
5.0
5.0 (USgpm)
(1.32)
(1.32) 99(80)
(80) (USgpm)
99 (USgpm)
(2.4)
(2.4)
1.2 (11)
111.2
(9)(11)
(9) Input Torque
Input Torque
1 (9)
.8.8(7)1 (9)11
(7) 5.04.0 (1.32)
4.0 (1.06)
(1.06)
5.0 (1.32) 9 (80) 9 (80) 9 (2.4)9 (2.4)
11bar
bar (160
(160psi)
psi)diff.
diff. 66(53)
(53) 66(1.6)
(1.6)
Case Flow 4.0 3.0(1.06)
3.0 (.79)
(.79)
4.0 (1.06) 210bar
210 bar(3000
(3000psi)psi)Case
CaseFlow
Flow
.6.6(5)
.8 (7) (5) 11 Case
.8 (7) bar 11 Flow
(160
bar psi)
(160diff.
psi) diff.(290 6 (53) 6 (53) 6 (1.6) 6 (1.6)
Case Flow 20
20 bar
bar (290 psi)
psi) diff.
diff.
3.0 (.79)
2.0
2.0 (.53)
(.53)
3.0 (.79) 210 bar 210 (3000 psi) Case
bar (3000 psi) Flow
Case Flow
.6 (5)
.4.4(4)
(4)
.6 (5) Case Flow Case 33(27)
(27) 150bar
150 bar(2200
(2200psi)psi)Case Flow 33(0.8)
CaseFlow (0.8)
20 Case
bar 20 Flow
Flow
(290
bar psi)
(290diff.
psi)
2.0 diff.
1.0(.53)
1.0 (.26)
(.26)
.2.2(2)
.4 (4) (2)
.4 (4) 2.0 (.53) 3 (27) 3 (27) 3 (0.8)3 (0.8)
Case FlowCase Flow 150 bar 150(2200 psi) Case
bar (2200 psi) Flow
Case Flow
.2 (2) .2 (2) 1.000(.26) 1.0 (.26)
00 500500 1000 1000 1500
1500 2000 2000 2500 2500 30003000
0 00 500 1000
500 1000 15001500 2000 2000 2500
2500 3000
3000
0
0 500
0 1000
500 1000 1500
Speed1500
Speed 2000
(r/min)
(r/min) 2500 2500
2000 3000 3000 0 0500 500 1000 Speed
1500
1000
Speed(r/min) 2000
1500
(r/min) 2500
2000 3000
2500 3000
SpeedSpeed(r/min)(r/min) SpeedSpeed
(r/min)(r/min)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 25
Performance

Industrial
PVM045

Typical Noise Levels at 1800 and 1200 r/min


with Petroleum Oil (10W) at 50°C (120°F) Delivery and Efficiency at 1800 r/min
Typical
andNoise Levels
1.0 bar at 1800
absolute and
(0 psi 1200 Inlet
gauge) r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
72 with Petroleum Oil (10W) at 50°C (120°F) 100
and 1.0 bar absolute (0 psi gauge) Inlet
7270 Volumetric Efficiency
1800 r/min 90 Delivery and Efficiency at 1800 r/min
Overall (0
50°C (120°F) and 1.0 bar absolute Efficiency
psi gauge) Inlet
7068 Max. Flow
1800 r/min 80 100
6866 Max. Flow
70 90 Volumetric Efficiency
Noise Level – dBA

6664 Overall Efficiency

Efficiency – %
1800 r/min 60 80
Noise Level – dBA

6462 Min. Flow


62601800 r/min
Min. Flow 50 70

Delivery – l/min (USgpm)


6058 1200 r/min

Efficiency – %
Max. Flow 40 60 102 (27)
Delivery (effective flow)
5856 1200 r/min
Max. Flow 30 50 76 (20)
1200 r/min
5654

Delivery – l/min (USgpm)


Min. Flow
1200 r/min 20 40 49 (13)
102 (27)
5452 Min. Flow Delivery (effective flow)
10 30 27 (7)76 (20)
5250
5048 0 20 0 49 (13)
50 0 100 150 200 250 300 0 50 100 150 200 250 300 350
48 (700) (1500) (2200) (2900) (3600) (4400) (700) (1500) (2200) (2900) (3600) (4400) (5000)
10 27 (7)
Sound pressure data Outlet
0 50 100 Pressure
150 –200
bar (psi)
250 300 Outlet Pressure – bar (psi)
(700)
equivalent to NFPA (1500) (2200) (2900) (3600) (4400)
0 0
Sound pressure data Outlet Pressure – bar (psi) 0Input 50
Torque100 150 at
and Power 2001800250r/min 300 350
equivalent to NFPA (700)
Typical Noise Levels at 1500 and 1000 r/min 50°C (120°F) and (1500)
1.0 bar(2200) (2900)
absolute (3600)
(0 psi Inlet(5000)
(4400)
gauge)
with Petroleum Oil (10W) at 50°C (120°F) 240 (2125) Outlet Pressure – bar (psi)
TypicalandNoise Levels
1.0 bar at 1500
absolute and
(0 psi 1000 Inlet
gauge) r/min
72 with Petroleum Oil (10W) at 50°C (120°F) 210 (1860) Input Torque and Power at 1800 r/min
and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 Torque,
Input bar absolute (0 psi gauge) Inlet
7270 1500 r/min 240 (2125) Full Stroke
Max. Flow 1500 r/min
Input torque – Nm (in.lb.)

180 (1595)
7068 1500 r/min Min. Flow
Max. Flow 1500
1000r/min
r/min 210 (1860) Input Power,
Min. Flow
Max. Flow150 (1325) Input Torque,
Full Stroke 50 (67)
6866 Full Stroke
1000 r/min
Input torque – Nm (in.lb.)

180 (1595)

Input Power – kW (hp)


Noise Level – dBA

Max. Flow 120 (1060) 40 (54)


6664
Input Power,
Noise Level – dBA

150 (1325) Full Stroke 50 (67)


6462 90 (795) 30 (40)
1000 r/min Input Power – kW (hp)
6260 Min. Flow 120 (1060) 40 (54)
1000 r/min 60 (530) Input Torque, 20 (27)
6058 Min. Flow 90 (795) Cut-off
30 (40)
30 (265) 10 (13)
5856
60 (530) Input Torque, 20 (27)
5654 0 0
0 50 Cut-off
100 150 200 250 300 350
30 (265) (700) (1500) (2200) (2900) (3600) (4400) (5000) 10 (13)
5452 Outlet Pressure – bar (psi)
0 50 100 150 200 250 300
52 (700) (1500) (2200) (2900) (3600) (4400) 0 0
0 50 100 Pressure
Outlet 150 –200
bar (psi)250 300 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

26 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM045

Delivery and Efficiency at 1500 r/min Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 100
Volumetric Efficiency Volumetric Efficiency
Delivery and Efficiency at 1200 r/min
90 Delivery and Efficiency at 1500 r/min 90 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Overall
50°C (120°F) and 1.0 bar Efficiency
absolute (0 psi gauge) Inlet Overall Efficiency
100
100
80 80Volumetric Efficiency
Volumetric Efficiency 90
70 90 Overall Efficiency
70 Overall Efficiency

Efficiency – %
80
Efficiency – %

60 80 60
70
50 70

Efficiency – %
50

– l/min (USgpm)

Delivery – l/min (USgpm)


Efficiency – %

60 76 (20)
40 60 102 (27) 40
Delivery (effective flow) 50 Delivery (effective flow) 57 (15)

Delivery – l/min (USgpm)


30 50 76 (20) l/min (USgpm) 30
40 76 (20)
20 40 102 (27)
49 (13) 20 38 (10)
Delivery (effective flow) Delivery (effective flow) 57 (15)
Delivery

30
10 30 76
27 (20)
(7) 10 19 (5)
20 38 (10)
020 49
0 (13) 0 0
Delivery –

50 100 150 200 250 300 350 0 0 50 100 150 200 250 300 350 19 (5)
(700) (1500) (2200) (2900) (3600) (4400) (5000) 10 (700) (1500) (2200) (2900) (3600) (4400) (5000)
10 27 (7)
Outlet Pressure – bar (psi) 0 Outlet Pressure – bar (psi) 0
0 0 0 50 100 150 200 250 300 350
0 50 100 150 200 250 300 350 (700) (1500) (2200) (2900) (3600) (4400) (5000)
(700)Torque
Input (1500)and
(2200) (2900)
Power at(3600) r/min (5000)
1500 (4400) Input Torque and Power at (psi)
1200 r/min
Outlet Pressure – bar
50°C (120°F) and 1.0 Pressure
Outlet bar absolute
– bar(0(psi)
psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125) 240 (2125)
Input Torque and Power at 1500 r/min Input Torque and Power at 1200 r/min
210 (1860) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 210 (1860)50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125) Input Torque, 240 (2125)
Full Stroke Input Torque,
Input torque – Nm (in.lb.)

180 (1595)
Input Torque – Nm (in.lb.)

180 (1595) Full Stroke


210 (1860) 210 (1860)
150 (1325) Input Torque, 150 (1325) Input Torque,
Input Torque – Nm (in.lb.)

Full Stroke
Input torque – Nm (in.lb.)

180 (1595) 180 (1595) Full Stroke


120 (1060) 40 (54)
Input Power, 120 (1060)
(hp)– kW (hp)

150 (1325) 150 (1325) Input Power,

Input Power – kW (hp)


Full Stroke
90 (795) 30 (40) Full Stroke
90 (795) 30 (40)
120 (1060) 40 (54) 120 (1060)
Input Power, 20 (27) Input Power, Input Power – kW (hp)
60 (530) 20 (27)
Power

Full Stroke 60 (530) Full Stroke


90 (795) 30 (40) 90 (795) 30 (40)
– kW

30 (265) 10 (13)
30 (265) 10 (13)
Input

60 (530) 20 (27) 60 (530) 20 (27)


Input Power

0 0 0
0 50 100 150 200 250 300 35010 (13) 0
30 (265) 30 (265)
0 50 100 150 200 250 300 350 10 (13)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
0 Outlet Pressure – bar (psi)
0 0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 27
Performance

Industrial
PVM045

Delivery and Efficiency at 1000 r/min Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 2,0 (0.53)
Delivery and Efficiency at 1000 r/min Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
9050°C (120°F) andOverall Efficiency
1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
1,8 (0.47)
Volumetric Efficiency 2,0 (0.53)

l/min (USgpm)
100
80 1,6 (0.42)
90 Overall Efficiency 1,8 (0.47)
70 1,4 (0.37)

(USgpm)
Volumetric Efficiency
1,6 (0.42)
–%

80
60 1,2 (0.32)
Efficiency

70 1,4 (0.37)

l/min –
Delivery – l/min (USgpm)
50 1,0 (0.26)

– Flow
–%

60 1,2 (0.32)
40 76 (20) 0,8 (0.21)
Efficiency

Case 1,0 (0.26)


Delivery – l/min (USgpm)
50 Case Flow
30 Delivery (effective flow) 57 (15) 0,6 (0.16)
40 76 (20) 0,8 (0.21)
20 38 (10) 0,4 (0.10)
0,6 (0.16)
30
10 Delivery (effective flow) 1957 (15)
(5) 0,2 (0.05)
20 38 (10) 0,4 (0.10)
0 0 0
50 0
100 150 200 250 300 350 0,2 (0.05) 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)19 (5)
10
(700) (1500) (2200) (2900) (3600) (4400) (5000)
0 Outlet Pressure – bar (psi) 0 Outlet Pressure – bar (psi)
0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Input Torque
Outletand Power– at
Pressure bar1000
(psi)r/min Case Flow Versus Outlet
Outlet Pressure
Pressure – bar at Cutoff, 1800 r/min
(psi)
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125) 6 (1.59)
Input Torque and Power at 1000 r/min Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
210 (1860)50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125) Input Torque, 65 (1.59)
Full Stroke (1.32)
– Nm (in.lb.)

180 (1595)
210 (1860)
l/min (USgpm)

Input Torque, 54 (1.32)


Full Stroke (1.06)
150 (1325)
Nm (in.lb.)

180 (1595)
(USgpm)

120 (1060) 43 (1.06)


Input–Torque

(0.79)
150 (1325)
Input Power – kW (hp)

90 (795) Input Power, 30 (40)


l/min –

Full Stroke
– Flow

120 (1060) 32 (0.79)


Input Torque

(0.53)
Input Power – kW (hp)

60 (530) 20 (27)
Case

90 (795) Input Power, 30 (40)


Case Flow

Full Stroke 21 (0.53)


30 (265) 10 (13) (0.26)
60 (530) 20 (27)
0 0 1 (0.26)0
30 (265)0 50 100 150 200 250 300 350 10 (13) 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
0 0 0 Outlet Pressure – bar (psi)
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

28 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM045

Typical Noise Levels Delivery and Case Flow Versus Speed


Petroleum Oil (10W) at 93°C (200°F), @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
Typical Noise Levels
1.0 bar absolute (0 psi gauge) Inlet 120 (32)
Petroleum Oil (10W) at 93°C (200°F),
(Sound pressure data equivalent to NFPA)
1.0 bar absolute (0 psi gauge) Inlet 110 (29) Delivery and50 Case Flowpsi),
Versus Speed

Delivery – l/min (USgpm)


82 bar (700
(Sound
2600 pressure data equivalent to NFPA)
r/min @ 93°C (200°F), full flow Delivery
and 1.0 bar absolute (0 psi) gauge Inlet
82 Max. Flow 100 (26)
2600 r/min 120 (32)
78 90 (24)
Max. Flow 110 (29)

Delivery – l/min (USgpm)


78 50 bar (700 psi),
280 bar (4000 psi),
74 80 (21) Delivery Delivery
100 (26)
70 (18)
– dBA

74

Case Flow – l/min (USgpm)


90 (24)
70 60 (16) 280 bar (4000 psi),
– dBA

600 r/min 80 (21) Delivery 2,5 (.7)


70 2600 r/min
Level

Min. Flow 50 (13)


66 Min. Flow 600 r/min 70 (18)

Case Flow – l/min (USgpm)


2600 r/min 280 bar (4000 psi), 2,0 (.5)
Level

Min. Flow 40 (11)


66
Noise

Min. Flow 60 (16) Case flow


62 1,52,5
(.4)(.7)
30 (8)
Noise

50 (13)
62 20 (5) 1,02,0
(.3)(.5)
58 600 r/min
Max. Flow
40 (11) 50280
bar bar
(700(4000
psi), psi),
10 30
(3) (8) Case
Case flowflow 0,51,5
(.1)(.4)
58 600 r/min
54 Max. Flow 0
0 1,0 (.3)
200(5) 500 1000 1500 2000 2500 3000
54 50 bar (700 psi),
50 Speed – r/min 0,5 (.1)
0 50 100 150 200 250 300 10 (3) Case flow
50 (700) (1500) (2200) (2900) (3600) (4400) 0 0
0 50 Outlet
100Pressure
150 – bar
200(psi) 250 300 0 500 1000 Versus
Input Torque 1500 Speed
2000 2500 3000
(700) (1500) (2200) (2900) (3600) (4400) Speed – r/min
Outlet Pressure – bar (psi) @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
225 (1991)
210 (1858) 280 bar (4000 psi)
Overall Efficiency Versus Speed Input Torque Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet 195 (1726)
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
Overall Efficiency Versus Speed 250 bar (3600 psi)
180225 (1991)
(1593)
Input Torque – Nm (in.lb.)

95
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet 280 bar (4000 psi)
95 165210 (1858)
(1460)
100 bar 200 bar (2900 psi)
(1500 psi) 150195 (1726)
(1327) 250 bar (3600 psi)
100 bar
90 135180 (1593)
Input Torque – Nm (in.lb.)

(1195) 150 bar (2200 psi)


(1500 psi)
90 150 bar 165 (1460)
120 (1062) 200 bar (2900 psi)
(2200 psi)
150 bar 150 (1327)
– %– %

105 (929) 100 bar (1500 psi)


85 (2200 psi) 50 bar 135 (1195) 150 bar (2200 psi)
200 bar (700 psi) 90 (796)
Efficiency

85 50 bar 120 (1062)


(2900 psi) 75 (664)
200 bar (700 psi)
Efficiency

105 (929)
60 (531) 50
100bar
bar(700 psi)psi)
(1500
80 (2900 psi)
45 90 (796)
(398) 25 bar (365 psi)
80 250 bar 75 (664)
30 (265)
(3600 psi) 1750
barbar
(250 psi)psi)
(700
250 bar 60 (531)
0
75 17 bar
(3600 psi) (250 psi) 0
45 (398) 500 1000 1500 2000 25 bar (365 3000
2500 psi)
75 280 bar 17 bar Speed – r/min
(4000 psi) (250 psi) 30 (265)
280 bar 17 bar (250 psi)
70 (4000 psi) 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
70 Speed – r/min Speed – r/min
0 500 1000 1500 2000 2500 3000
Speed – r/min

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 29
Performance

Mobile
PVM045

Input Power Versus Speed


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
56 (75)
280 (4000)
52 (70)
250 (3600)
48 (64)

Flow – kW (hp)
Input Power Versus Speed
44 (59)
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
200 (2900)

– bar (psi)
40
56 (54)
(75)
280 (4000)
36 (70)
52 (48)
250 (3600)
32
48 (43)
(64)

(hp)
150 (2200)

kWFull
28 (59)
(38)

Pressure – barPressure
44

Flow – @
24
40 (32) 200 (2900)

(psi)
(54)
100 (1500)

Full Power
20 (48)
36 (27)
16
32 (21)
(43)
150 (2200)
Flow – l/min (USgpm)Input Power @Input

12 (38)
28 (16) 50 (700)
8 (11)
24 (32) 25 (365)
100(250)
17 (1500)
204(27)
(5)
16 (21) 0
0 500 1000 1500 2000 2500 3000
12 (16) Speed – r/min 50 (700)
8 (11) 1.Case Flow at 2600 r/min, Full Flow25 (365)
17Inlet
4 (5)93°C (200°F), 1.0 bar absolute (0 psi gauge) (250)
6 (1.6)
0
5 (1.3) 0 500 1000 1500 2000 2500 3000
4 (1.1) Speed – r/min
3 (0.8) 1.Case Flow at 2600 r/min, Full Flow
Case(USgpm)

2 (0.5) 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet


1 (1.6)
6 (0.3)
5 (1.3)0
0 50 100 150 200 250 300 350
Case Flow – l/min

4 (1.1) (700) (1500) (2200) (2900) (3600) (4400) (5000)


3 (0.8) Outlet Pressure – bar (psi)
2 (0.5)
Case Flow at Cutoff at 2600 r/min
1 (0.3) 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Flow – l/min (USgpm)

42 (11.1)0
0 50 100 150 200 250 300 350
38 (10.0) (700) (1500) (2200) (2900) (3600) (4400) (5000)
34 (9.0) Outlet Pressure – bar (psi)
30 (7.9) Case Flow at Cutoff at 2600 r/min
26 (6.9) 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Case(USgpm)

42
22(11.1)
(5.8)
38
18(10.0)
(4.8)
34
14 (9.0)
(3.7)
Case Flow – l/min

30
10 (7.9)
(2.6)
26 (6.9) 0 (700)50 100 150 200 250 300 350
(1500) (2200) (2900) (3600) (4400) (5000)
22 (5.8) Outlet Pressure – bar (psi)
18 (4.8)
14 (3.7)
10 (2.6)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

30 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM050
Typical Noise Levels at 1800 and 1200 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
72
1800 r/min
Typical
max.Noise
flow Levels at 1800 and 1200 r/min with Delivery and Efficiency at 1800 r/min, 50°C (120°F),
68Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar and 1.0 bar absolute (0 psi gauge) Inlet
absolute (0 psi gauge) Inlet Delivery and Efficiency at 1800 r/min, 50°C (120°F),
72 1200 r/min 100 and 1.0 bar absolute (0 psi gauge) Inlet
64 max. flow
1800 r/min Volumetric Efficiency
– dBA Level – dBA

max. flow 90
100
68 Volumetric EfficiencyOverall Efficiency
60
80
90
Overall Efficiency
64 1200 r/min
70
56 max.
1800 flow 80

–% –%
r/min
Noise Level Noise

1200 r/min
min. flow min. flow 60
70

Efficiency
60

(USgpm)
52
50
60 125 (33)

Efficiency

(USgpm)
56 1800 r/min 1200 r/min 40
50 100 (33)
125 (26)
48 min. flow
min. flow

– l/min
30
40 Delivery (effective flow) 75 (20)
100 (26)
52
44

– l/min
0 50 100 150 200 250 20
30 Delivery (effective flow) 50 (20)
75 (13)

Delivery
(700) (1500) (2200) (2900) (3600)
48 10
20 25 (13)
50 (7)

Delivery
Outlet Pressure – bar (psi)
0
0
44
10 0 50 100 150 200 250 25 (7)
0 50 100 150 200 250 (700) (1500) (2200) (2900) (3600)
0
(700) (1500) (2200) (2900) (3600) 0
0 50 Outlet100 150
Pressure 200
– bar (psi) 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

Input Torque and Power at 1800 r/min, 50°C (120°F),


and 1.0 bar absolute (0 psi gauge) Inlet
Typical Noise Levels at 1500 and 1000 r/min with Input Torque and Power at 1800 r/min, 50°C (120°F),
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar 240 (2124)
and 1.0 bar absolute (0 psi gauge) Inlet
absolute (0 psi gauge) Inlet
72 220 (1947)
240 (2124)
Nm (in-lb)

200 (1770)
Typical Noise Levels at 1500 and
max.1000
flow r/min with 220 (1947)
68Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar 180 (1593)
– Nm–(in-lb)

200 (1770) Input Torque,


1500 absolute
r/min (0 psi gauge) Inlet 160 (1416)
max. flow 180 (1593) Full Stroke
72 1000 r/min 140 (1239) Input Torque,
64
Torque

160 (1416) Full Stroke


– dBA Level – dBA

max. flow 120 (1062)

kW (hp)
68 140 (1239)
Torque

60 1500 r/min 100 (885) 50 (67)


120 (1062)
InputInput

– kW–(hp)
max. flow 80 (708) Input Power,
1000 r/min 100 (885) 40 (54)
64 Full Stroke 50 (67)
56 60 (531) 30 (40)
Noise Level Noise

Power

1500 r/min 80 (708) Input Power, 40 (54)


min. flow 40 (354) Input
Full Stroke Torque, 20 (27)
60 60 (531) 30 (40)
Power

52 Cut-off
20 (177) 10 (13)
InputInput

1000 r/min 40 (354) Input Torque, 20 (27)


min. flow 0 Cut-off 0
56 20 (177) 0
48 1500 r/min 50 100 150 200 250 (13)
10
min. flow 0 (700) (1500) (2200) (2900) (3600) 0
52 0 50 100 150 200 250
44 Outlet Pressure – bar (psi)
(700) (1500) (2200) (2900) (3600)
1000 r/min
0 50 100 min.150flow 200 250
(700) (1500) (2200) (2900) (3600) Outlet Pressure – bar (psi)
48
Outlet Pressure – bar (psi)
Sound pressure data
44
0equivalent
50to NFPA.
100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 31
Sound pressure data
Performance

Industrial
PVM050

Delivery and Efficiency at 1500 r/min, 50°C (120°F), Delivery and Efficiency at 1200 r/min, 50°C (120°F), De
and
Delivery 1.0Efficiency
and bar absolute (0 psi
at 1500 gauge)
r/min, Inlet
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet 100 100
100
Volumetric Efficiency Volumetric Efficiency
100
90 Volumetric Efficiency 90 90
Overall Efficiency Overall Efficiency
90 80 80
80 Overall Efficiency
80 70 70
– %– %

70

%
Efficiency –– %

%
Efficiency –– %
70 60 60
Efficiency

60

Efficiency

Efficiency
(USgpm)

(USgpm)
Efficiency

l/min (USgpm)
60
50 125 (33) 50 125 (33) 50
50 125 (33)
100 (26) (USgpm) 40 100 (26) 40
40 – l/min
40 100 (26)

Delivery –– l/min
30 75 (20) 30 75 (20) 30
Delivery (effective flow)
– l/min

30 75 (20) 20 Delivery (effective flow) 50 (13) 20


20 Delivery (effective flow) 50 (13)
Delivery

Delivery
20 50
25 (13)
(7) 10 25 (7) 10
10
Delivery

10 25 (7)
0 0 0
0 0
0 50 100 150 200 250 0 50 100 150 200 250
0 (700) (1500) (2200) (2900) (3600) 0 (700) (1500) (2200) (2900) (3600)
0 50 100 150 200 250
(700) (1500)
Outlet (2200)
Pressure (2900) (3600)
– bar (psi) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min, 50°C (120°F),


and 1.0and
Input Torque barPower
absolute (0 psir/min,
at 1500 gauge) Inlet
50°C (120°F), Input Torque and Power at 1200 r/min, 50°C (120°F),
and
240 (2124) 1.0 bar absolute (0 psi gauge) Inlet and 1.0 bar absolute (0 psi gauge) Inlet
240
220 (2124)
(1947) 240 (2124)
220
200 (1947)
(1770) 220 (1947)
Input Torque,
Full Stroke 200 (1770)
(in-lb)

200
180 (1770)
(1593) Input Torque,
(in.lb.)
Nm (in.lb.)

Full Stroke

(in.lb.)
180 (1593)

Nm (in.lb.)
(in-lb)

180 (1593)
160 (1416)
160 (1416) Input Torque,
– Nm

160
140 (1416)
(1239) Full Stroke
Torque –– Nm
– Nm

Torque –– Nm
140 140 (1239)
120 (1239)
(1062)
(hp)(hp)
Torque

120 (1062)
Input Torque

120
100(1062)
(885)
(hp)
kW (hp)
50 (67)
Torque

Input Torque
– kW

Input Power, 100 (885) 50 (67)


100 (885)
80 (708) 50
40 (67)
(54)
Input

Full Stroke
Power –– kW
– kW

Input Power, 80 (708) 40 (54)


Input

80
60 (708)
(531) 40
30 (54)
(40) Input Power,
Power
Input

Full Stroke
60
40 (531)
(354)
60 (531) Full Stroke 30 (40) Input
Input Power

30
20 (40)
Power

(27)
40 (354) 20 (27)
40
20 (354)
(177) 20 (27)
Input

10 (13)
20 (177) 10 (13)
20 (177)0
Input
Input

100 (13)
0 50 100 150 200 250 0 0
0 (700) (1500) (2200) (2900) (3600)0 0 50 100 150 200 250
0 50 100 150 200 250
(700) (700) (1500) (2200) (2900) (3600)
Outlet(1500) (2200)
Pressure – bar(2900)
(psi) (3600)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

32 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM050

Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,


Delivery
Delivery andand Efficiency
Efficiency at at 1000
1000 r/min,
r/min, 50°C
50°C (120°F),
(120°F), Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
and 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
and 1.01.0
barbar absolute
absolute (0 (0
psipsi gauge)
gauge) Inlet
Inlet 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
1.0 (0.26)
100 1.0 (0.26)
100
Volumetric
Volumetric Efficiency
Efficiency 0.9 (0.24)
0.9 (0.24)
9090
Overall
Overall Efficiency
Efficiency 0.8 (0.21)
0.8 (0.21)

(USgpm)
8080

l/min– –(USgpm)
0.7 (0.18)
7070 0.7 (0.18)
Efficiency – %

0.6 (0.16)
Efficiency – %

6060 0.6 (0.16)

Delivery – l/min (USgpm)

Flowl/min
Delivery – l/min (USgpm)

0.5 (0.13)

Delivery – l/min (USgpm)


Delivery – l/min (USgpm)

3) 5050 125
125 (33)
(33) 0.5 (0.13)
0.4 (0.11)

CaseFlow
6) 4040 100
100 (26)
(26) 0.4 (0.11)
0.3 (0.08)
3030 7575 (20)

Case
(20) 0.3 (0.08)
Delivery
Delivery (effective
(effective flow)
flow) 0.2 (0.05)
2020 5050 (13)
(13) 0.2 (0.05)

1010 2525
(7)(7) 0.1 (0.03)
0.1 (0.03)
0 00 0 0 0
00
0 5050 100100 150 150 200 200 250 250
0
50
50
100
100
150
150
200
200
250
250
(700) (1500)
(700) (1500) (2200)
(2200) (2900)
(2900) (3600)
(3600) (700) (1500) (2200) (2900) (3600)
(700) (1500) (2200) (2900) (3600)
Outlet
Outlet Pressure
Pressure – bar
– bar (psi)
(psi) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

Input
Input Torque
Torque andand Power
Power at at 1000
1000 r/min,
r/min, 50°C
50°C (120°F),
(120°F), Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
andand
1.01.0
barbar absolute
absolute (0 (0
psipsi gauge)
gauge) Inlet
Inlet Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
240240 (2124)
(2124) 10 (2.64)
10 (2.64)
220
220 (1947)
(1947) 9 (2.38)
9 (2.38)
200
200 (1770)
(1770)
8 (2.11)
Input Torque – Nm (in.lb.)

8 (2.11)
Input Torque – Nm (in.lb.)

180 (1593)
(USgpm)

180 (1593) Input Torque,


l/min– –(USgpm)

Input Torque, 7 (1.85)


160
160 (1416)
(1416) Full Stroke
Full Stroke 7 (1.85)
140
140 (1239)
(1239) 6 (1.59)
6 (1.59)
120
120 (1062)
(1062) 5 (1.32)
Input Power – kW (hp)
Input Power – kW (hp)

Flowl/min
Input Power – kW (hp)
Input Power – kW (hp)

100 (885) 5 (1.32)


) 100 (885) 5050 (67)
(67)
4 (1.06)
) 8080 (708) 4040 (54) 4 (1.06)
CaseFlow

(708) (54)
) 6060 (531)
(531) Input Power, 3030 (40)
(40) 3 (0.79)
Input Power, 3 (0.79)
Case

) 40 (354) Full Stroke


Full Stroke
40 (354) 2020 (27)
(27) 2 (0.53)
) 2 (0.53)
2020 (177)
(177) 1010 (13)
(13)
1 (0.26)
0 0 0 0 1 (0.26)
0 0 5050 100 100 150150 200 200 250250
0
(700)(1500)
(700) (1500) (2200)
(2200) (2900)
(2900) (3600)
(3600) 00 50 100 150 200 250
0 50
(700) 100
(1500) 150
(2200) 200
(2900) 250
(3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi) (700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 33
Performance

Mobile
PVM050 Typical Noise Levels at 2600
Typical Noise Levels at 2600 & 600&r/min
600 r/min
with with Petroleum
Petroleum Oil (10W)
Oil (10W)
at 93°C
at 93°C (200°F)
(200°F) andbar
and 1.0 1.0absolute
bar absolute
(0 psi(0gauge)
psi gauge)
inlet inlet
88 88

86 86
84 84
Typical Noise Levels at 2600 & 600 r/min
82 82 with Petroleum Oil (10W) at 93°C (200°F) and
Noise Level – dBA

26002600
r/minr/min
Noise Level – dBA

max. max.
flow flow 1.0 bar absolute (0 psi gauge) inlet
80 80 88
78 78 26002600
r/minr/min
86 min. flow
min. flow
76 76
84
74 74
82 600 r/min
600 r/min

Noise Level – dBA


72 72 2600 r/min
max. flow max. max.
flow flow
70 70 80
68 68 78 2600 r/min
min. flow
66 66 600 r/min 76
600 r/min
min. flow
min. flow
64 64 74
0 0 50 50 100 100 150 150 200 200 250 250
(1500) 72 (2200) 600 r/min
SoundSound data data(700)(700)
pressure
pressure (1500) (2200) (2900)
(2900) (3600)
(3600)
max. flow
equivalent
equivalent to NFPA.
to NFPA. OutletOutlet Pressure
Pressure bar–(psi)
–70 bar (psi)
68
66 600 r/min
min. flow
64
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.

Overall
Overall Efficiency
Efficiency versus
versus Speed Speed Delivery
Delivery and Case
and Case FlowFlow versus
versus SpeedSpeed at 93°C
at 93°C (200°F),
(200°F),
at 93°C
at 93°C (200°F)
(200°F) andbar
and 1.0 1.0absolute
bar absolute
(0 psi(0gauge)
psi gauge)
inlet inlet Full Flow
Full Flow andbar
and 1.0 1.0absolute
bar absolute
(0 psi(0gauge)
psi gauge)
inlet inlet
100 100

Case Flow – l/min (USgpm)


Case Flow – l/min (USgpm)
140 (37)
140 (37)
95 95 130 130 (34)
(34)
100(1500
100 bar bar (1500
psi) psi) 120 (32)
120 (32)
90 90 110 110
(29) (29) Speed 50 bar 50(725
bar (725
Overall Efficiency (%)
Overall Efficiency (%)

Overall Efficiency versus psi) Delivery


psi) Delivery Delivery and Case Flow
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)

85 200 bar
200 bar
85 at 93°C (200°F) and 1.0100 100
bar(26) (26) (0 psi gauge) inlet
absolute Full Flow and 1.0 bar a
(2900(2900
psi) psi) 210(3000
210 bar bar (3000
90 (24)
90 (24) psi) Delivery
80 100 psi) Delivery
80 80 (21)
80 (21) 140 (37)
95 70 (18)
70 (18) 130 (34)
75 75
210(3000
210 bar bar (3000
psi) psi) 100 bar (1500 psi) 120 (32)
60 (16)
60 (16)
70 70 90 210(3000
210 bar bar (3000 50
110 (29) 5 (1.32)
230 bar (3300
230 bar (3300 psi) psi) 50 (13) Flow Flow 5 (1.32)
Overall Efficiency (%)

50 (13) psi) Case


psi) Case ps
Delivery – l/min (USgpm)

65 65 85 200 bar 40 (11)


40 (11) 100 (26)4 (1.06)
4 (1.06)
(2900 psi) 30 (8)30 (8) 90 (24)3 (0.79)
3 (0.79)
60 60 80
20 (5)20 (5) 50(725
50 bar 80
bar (725 (21)
psi) psi) 2 2 (0.53)
(0.53)
55 55 75 (3)10 psi)
(3) Case Case
Flow Flow70 (18) 1 (0.26)
1 (0.26)
210 bar10(3000
60 (16)0 0
50 50 70 2500 0 0500 500
10001000
1500 1500
2000 2000
2500 2500
3000 3000
0 0 500 500 1000 10001500 1500 2000 2000
2500 30003000
230 bar (3300 psi) 50 (13)
Speed Speed (r/min)
(r/min) 65 SpeedSpeed (r/min)
(r/min) 40 (11)
60 30 (8)
20 (5)
55 10 (3)
50 0 500 1000
1000 0 500
1500 2000 2500 3000
34 EATON Speed (r/min)
Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 S
Performance

Mobile
PVM050

Input Torque
InputInput
Torque versus
InputTorque
Torque
versus Speed
versus
versus
Speed at
at 93°C
Speed
Speed (200°F),
atat93°C
93°C 93°C(200°F),
(200°F),
(200°F), Input Power
InputInput
Power versus
InputPower
Power
versus Speed
versus
versus
Speed at
at 93°C
Speed
Speed 93°C (200°F),
atat93°C
93°C(200°F),
(200°F),
(200°F),
Full
Full Flow
Flow
Full and
FullFlow
Flow
and 1.0 bar
and
1.0
and absolute
1.0
bar
1.0 (0
(0 psi
barabsolutepsi(0gauge)
absolute
absolute
bar (0 Inlet
psigauge)
gauge)
psi gauge) Inlet
Inlet Inlet Full
Full Flow
Flow
Full and
FullFlow
and 1.0
Flow
1.0
andbar
and
bar
1.0absolute
1.0
absolute
bar (0
(0 psi
barabsolutepsi(0gauge)
absolute (0
gauge)
psi Inlet
psigauge)
gauge) Inlet
Inlet Inlet
300
300 (2655)
300(2655)
300
(2655) (2655) 60
60 (80)
60(80)
(80)
60 (80)
275
275 (2434)
275(2434)
275
(2434) (2434) 55
55 (74)
55(74)
(74)
55 (74) 230
230 bar (3300
230
bar
230 psi)
bar(3300
(3300
bar (3300psi)
psi) psi)
230 210
210 bar
bar
210(3000
210
(3000
bar psi)
bar(3000
(3000psi)
psi) psi)
250
250 (2212)
250(2212)
(2212)
250 (2212) 230 bar230bar
bar
230 bar 50
50 (67)
50(67)
(67)
50 (67)
200
200 bar (2900
200 psi)
bar(2900
(2900psi)
psi)
(in.lb.)

Input Torque – Nm (in.lb.)

bar
200(2900
bar psi)
Nm (in.lb.)

Input Torque – Nm (in.lb.)

(3300 psi)
(3300 psi)

(hp)

Input Power – kW (hp)


(3300 (3300
psi) psi)

kW (hp)

Input Power – kW (hp)


225
225 (1991) 210
210 bar
225(1991)
(1991)
225 (1991) 210bar
bar
210 bar 45
45 (60)
45(60)
(60)
45 (60)
(3000 psi)
(3000
(3000(3000 psi)
psi) psi)

Power –– kW
200
200 (1770)
200(1770)
(1770)
200 (1770) 40
40 (54)
40(54)
(54)
40 (54)
Torque –– Nm

175
175 (1549)
175(1549)
(1549)
175 (1549) 35
35 (47)
35(47)
(47)
35 (47)

Input Power
200
200 bar
bar
200(2900
200
(2900
bar psi)
bar(2900
(2900 psi)
psi) psi)
Input Torque

150
150 (1327)
150(1327)
(1327)
150 (1327) 30
30 (40)
30(40)
(40)
30 (40)
100
100 bar
bar
100(1500
100
(1500
bar psi)
bar(1500
(1500psi)
psi) psi)
125
125 (1106)
125(1106)
(1106) 25
25 (34)
25(34)
(34)
25 (34)

Input
(1106)
125
Input

100
100 (885)
100(885)
(885)
100 (885) 20
20 (27)
20(27)
(27)
20 (27)
100
100 bar
bar
100(1500
100
(1500
bar psi)
bar(1500
(1500 psi)
psi) psi) 15
75
75 (664)
75(664)
(664)
75 (664) 15 (20)
15(20)
(20)
15 (20)

50
50 (442)
50(442)
(442)
50 (442) 10
10 (13)
10(13)
(13)
10 (13)
17
17 bar
bar
17(250
17 barpsi)
(250
bar (250psi)
(250
psi) psi) 17
17 bar (250
17
bar17
(250
barpsi)
bar (250psi)
psi)
(250 psi)
25
25 (221)
25(221)
(221)
25 (221) 55 (7)
(7) 55(7)
(7)

00 0 00 00
00 0 0 0 500
500
500 1000
500 1500
1000
1000 1000 2000
1500
1500 1500 2500
2000
2000 2000 3000
2500
2500 2500 3000
3000 3000 00 500
0500 1000
0 500
1000 1500
500 1000
1000 2000
1500
1500 1500 2500
2000
2000 2000 3000
2500
2500 2500 3000
3000 3000
Speed
Speed (r/min)
Speed
Speed
(r/min) (r/min)
(r/min) Speed
Speed (r/min)
Speed
Speed
(r/min) (r/min)
(r/min)

Input Torque
InputInput
Torque and
and Case
InputTorque
Torque Flow
andCase
Case
and versus
CaseFlow
Flow Speed
Flowversus
versus versus
Speed at
Speed
at atat
Speed Input Torque
InputInput
Torque and
and Case
InputTorque
TorqueCase
and Flow
andCase
Flow versus
CaseFlow
versus Speed
Flowversus
versus
Speed Speed
Speed
93°C (200°F),
93°C 93°C Load
93°C(200°F),
(200°F),
(200°F), Sense
LoadSense
LoadLoad
Sense Standby
Sense and
and 1.0
Standby
Standby
Standby 1.0 bar
and
and bar 1.0bar
1.0 bar at
at 93°C
93°C (200°F),
atat93°C
(200°F), Pressure
93°C(200°F),
(200°F),
Pressure Limit
Pressure
Pressure Cut-off
LimitLimit
Cut-off and
LimitCut-off
Cut-off
and andand
absolute (0
(0 psi
psi(0gauge)
absolute
absolute
absolute (0 Inlet
psigauge)
gauge)
psi gauge) Inlet
Inlet Inlet 1.0
1.0 bar
bar absolute
1.0
1.0absolute
bar (0
(0 psi
psi(0gauge)
barabsolute
absolute (0
gauge)
psi Inlet
psigauge)
gauge) Inlet
Inlet Inlet
88 (71)
(71)88(71)
(71)
55
55(487)55(487)
(487)
55 (487)

77 (62)
(62)77(62)
(62) 50
50(442)50(442)
(442)
50 (442)
20
20 bar
bar20(300
20 barpsi)
(300
bar (300
(300
psi) diff.
psi)diff.
diff.
psi) diff. Case Flow
CaseFlow
Flow 210
210 bar
bar
210(3000
210
(3000
bar psi)
psi) Input
bar(3000
(3000 Input
psi) Torque
psi)Input
InputTorque
Torque Torque
Input Torque
InputTorque
Torque CaseCase
Flow 45
45(398)45(398)
(398)
45 (398)
Input Input
Torque l/min l/min
(in.lb.)

Input Torque – Nm (in.lb.)

l/min l/min
Nm (in.lb.)

Input Torque – Nm (in.lb.)

66 (53)
(53)66(53)
(53)
(in.lb.)

Input Torque – Nm (in.lb.)

(USgpm) (USgpm) 40
40(354)40(354)
(354)
Nm (in.lb.)

Input Torque – Nm (in.lb.)

(USgpm)(USgpm) (354)
40
210
210 bar210bar
bar
210 bar
55 (44)
(44)55(44)
(44) 5.0
5.0 (1.32)
5.0(1.32)
(1.32)
5.0 (1.32) 35
35(310)35(310)
(310)
35 (310)
(3000 psi)
(3000 psi)
Torque –– Nm

11
11 bar (160
bar1111 barpsi)
(160
bar (160
(160
psi) diff.
psi)diff.
diff.
psi) diff. (3000(3000
psi) psi)
Case Flow
Case Flow
Torque –– Nm

Input Torque
InputTorque
Input Input
Torque Torque 30
30(265) Case
30(265)
(265)
30 (265) Case
Flow Flow Case Case
CaseCase
44 (35)
(35)44(35)
(35) 4.0
4.0 (1.06)
4.0(1.06)
(1.06)
4.0 (1.06) Flow
Flow l/min
Flowl/min
Flow
l/min l/min
Input Torque

25
25(221)25(221)
(221)
25 (221) (USgpm)
(USgpm)(USgpm)
(USgpm)
Input Torque

33 (27)
(27)33(27)
(27) 3.0
3.0 (.79)
3.0(.79)
(.79)
3.0 (.79) 12
20
20 bar
bar
20(300
20
(300barpsi)
bar (300psi)
(300
psi) psi) 20
20(177)
(177)
2020(177)
(177) 12 (3.2)12(3.2)
(3.2)
12 (3.2)
Input

diff.
diff. Case
Case
diff. Flow
diff.Case
CaseFlow
Flow Flow 15 150
150 bar
bar
150 (2200
150 bar
(2200
bar psi)
(2200
(2200
psi) psi)
psi)
22 (18)
(18)22(18)
(18) 2.0
2.0 (.53)
2.0(.53)
(.53) 15(133)
(133)
1515(133)
(133) 99 (2.4)
99(2.4)
(2.4) (2.4)
Input

(.53)
2.0 Input Torque
InputTorque
Input Input
Torque Torque
11
11 bar (160
bar1111
(160barpsi)
bar (160psi)
(160
psi) psi)
diff.Case
diff.Case Flow
diff.Case
diff.Case Flow
Flow Flow 10
10(88)
(88)
1010(88)
(88) 66 (1.6)
66(1.6)
(1.6) (1.6)
11 (9)
(9) 11(9)
(9) 1.0
1.0 (.26)
1.0(.26)
(.26)
1.0 (.26) 150 bar (2200
150 psi)
bar(2200
(2200Case Flow
psi)Case
CaseFlow
Flow
55(44) 150 bar
150(2200
bar psi) Case
psi) Flow 33 (0.8)
(44)55(44)
(44) 33(0.8)
(0.8) (0.8)
00 00
00 0
0500 1000
500
500 500 1500
1000
1000 1000 2000
1500
1500 1500 2500
2000
2000 2000 3000
2500
2500 2500 3000
3000 3000 00 0500 500
0500 1000
500 1500
1000 2000
1500 2500
2000 3000
2500 3000
1000 1000
1500 1500
2000 2000
2500 2500
3000 3000
Speed
Speed (r/min)
Speed
Speed
(r/min)(r/min)
(r/min) Speed
Speed (r/min)
Speed
Speed
(r/min)(r/min)
(r/min)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 35
Performance

Industrial
PVM057

Typical Noise Levels at 1800 and 1200 r/min


Typical Noise Levels
with Petroleum at 1800
Oil (10W) and(120°F)
at 50°C 1200 r/min Delivery and Efficiency at 1800 r/min
with1.0
and Petroleum Oil (10W)
bar absolute (0 psiat 50°C (120°F)
gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
74 and 1.0 bar absolute (0 psi gauge) Inlet 100
74 Volumetric Efficiency
Delivery and Efficiency at 1800 r/min
90 50°C (120°F)Overall
and 1.0 bar absolute (0 psi gauge) Inlet
Efficiency
1800 r/min 100
70 80 Volumetric Efficiency
Max. Flow
1800 r/min
70 Max. Flow 1800 r/min 90 Overall Efficiency
Min. Flow
1800 r/min 70
Noise Level – dBA

Efficiency – %
Min. Flow 80
Noise Level – dBA

66 60
66 70

Delivery – l/min (USgpm)


50 130 (34)

Efficiency – %
1200 r/min
Max. Flow 60 Delivery (effective flow)
62 1200 r/min 40 104 (28)
Max. Flow
62

Delivery – l/min (USgpm)


50 130 (34)
30 78 (21)
Delivery (effective flow)
40 104 (28)
58 20 52 (14)
58 1200 r/min 30 78 (21)
Min. Flow
1200 r/min 10 26 (7)
Min. Flow 20 52 (14)
54 0 0
0
54 50 100 150 200 250 300 0 10 50 100 150 200 250 300 350 26 (7)
0 (700)50 (1500)
100 (2200)
150 (2900)
200 (3600)
250 (4400)
300 (700) (1500) (2200) (2900) (3600) (4400) (5000)
(700) (1500) (2200) (2900) (3600) (4400) 0 Outlet Pressure – bar (psi) 0
Outlet Pressure – bar (psi)
Outlet 0 50 100 150 200 250 300 350
(Sound pressure dataPressure – bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
(Sound pressure
equivalent to NFPA)data Outlet Pressure – bar (psi)
equivalent to NFPA)
Input Torque and Power at 1800 r/min
Typical Noise Levels at 1500 and 1000 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Typical Noise Levels
with Petroleum at 1500
Oil (10W) and(120°F)
at 50°C 1000 r/min 300 (2655)
with1.0
and Petroleum Oil (10W)
bar absolute (0 psiat 50°C (120°F)
gauge) Inlet Input Torque and Power at 1800 r/min
70 and 1.0 bar absolute (0 psi gauge) Inlet 270 (2390) Input
50°C (120°F) and 1.0 Torque,
bar absolute (0 psi gauge) Inlet
70 300 (2655) Full Stroke
240 (2124)
1500 r/min
Input Torque – Nm (in.lb.)

Max. Flow 270 (2390) Input Torque,


1500 r/min 210 (1859) Full Stroke
66 Max. Flow
240 (2124)
66 180 (1593) 60 (80)
Input Torque – Nm (in.lb.)
Noise Level – dBA

1000 r/min 210 (1859)


Noise Level – dBA

Max. Flow
1000 r/min 150 (1328) 50 (67)
1500 r/min Max. Flow
Input Power – kW (hp)

Min. Flow 180 (1593) Input Power, 40 (54) 60 (80)


62 1500 r/min 120 (1062)
Min. Flow Full Stroke
62 150 (1328) 50 (67)
90 (797) 30 (40)
Input Power – kW (hp)

120 (1062) Input Power, 40 (54)


60 (531) Full Stroke
20 (27)
58 1000 r/min 90 (797) 30 (40)
58 1000
Min. r/min
Flow 30 (266) Input Torque, 10 (13)
Min. Flow 60 (531) Cut-off 20 (27)
0 0
0 50 100 150 200 250 300 350
30 (266)
(700) (1500) (2200) (2900) (3600) (4400) Torque, 10 (13)
(5000)
Input
54 Cut-off
0
54 50 100 150 200 250 300 0 Outlet Pressure – bar (psi) 0
0 50 (1500)
(700) 100 (2200)
150 (2900)
200 (3600)
250 (4400)
300 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

36 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM057

Delivery and Efficiency at 1500 r/min Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F)Delivery
and 1.0and
bar Efficiency
absolute (0atpsi1200 r/min
gauge) Inlet
100 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 Delivery and Efficiency at 1500 r/min 100
Volumetric Efficiency Volumetric Efficiency
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 90 Volumetric Efficiency
90100 90
Overall Efficiency Volumetric Efficiency Overall Efficiency
80 Overall Efficiency
80 90 80
Overall Efficiency
70 80 70
70

Efficiency – %
Efficiency – %

60

Efficiency – %
60 70 60
100 (26)

Delivery – l/min (USgpm)


50
Efficiency – %

Delivery – l/min (USgpm)


50 60 100 (26) 100 (26)

Delivery – l/min (USgpm)


50
40 80 (21)
40 50 80100
(21)(26) 80 (21)
Delivery – l/min (USgpm)
40
Delivery (effective flow) 60 (16)
30 40 6080
(16) 30
(21) 30 Delivery (effective flow) 60 (16)
Delivery (effective flow) Delivery (effective flow)
20 40 (11)
20 30 4060
(11)
(16) 20 40 (11)
10 20 (5)
10 20 2040
(5)(11) 10 20 (5)
0 20 (5) 0 0
0 10 0 0 50 100 150 200 250 300 350 0
0 50 100 150 200 250 300 350 0
(700) 50
(1500) 100
(2200)150
(2900)200
(3600)250
(4400)300
(5000)350
(700) (1500) (2200) (2900) (3600) (4400) (5000)0 (700) (1500)
Outlet (2200)– (2900)
Pressure (3600) (4400) (5000)
bar (psi)
0
0 50Outlet
100Pressure
150 –200bar (psi)
250 300 350 Outlet Pressure – bar (psi)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1200 r/min
330 (2921) Input Torque and Power at 1500 r/min 50°C (120°F)Input
and Torque
1.0 bar and Power
absolute (0 at
psi1200 r/min
gauge) Inlet
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 330 (2921) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
300 (2655) 330 (2921)
330 (2921)
270300
(2390) 300 (2655)
(2655) 300 (2655)
Input Torque – Nm (in.lb.)

Input Torque, 270 (2390)


240 (2124) Full Stroke 270 (2390)
270 (2390) Input Torque,
– Nm (in.lb.)
Input Torque – Nm (in.lb.)

Input Torque, 240 (2124) Input Torque,


Full Stroke
Input Torque – Nm (in.lb.)

210 (1859) 240 (2124) Full Stroke


240 (2124) Full Stroke
210 (1859)
180210
(1593)
(1859) 60 (80) 210 (1859)
Input Power,
Full Stroke 180 (1593)
150180
(1328) 5060
(67)
kW (hp)

(1593) (80) 180 (1593)


Input Power –Torque

Input Power, 150 (1328) Input Power,


Input Power – kW (hp)
120 (1062) Full Stroke 4050
(54) 150 (1328) Input Power, 40 (54) Input Power – kW (hp)
150 (1328) (67)
kW (hp)

Full Stroke
120 (1062) Full Stroke 40 (54)
90120
(797) 30 (40) 120 (1062)
Input Power –Input

(1062) 40 (54) 30 (40)


60 (531) 90 (797) 30 (40)
90 (797) 2030
(27)
(40) 90 (797)
60 (531) 20 (27)
30 (266) 10 (13) 60 (531) 20 (27)
60 (531) 20 (27)
0 30 (266) 10 (13)
0 30 (266) 10 (13)
30 (266)
0 50 100 150 200 250 300 350 10 (13)
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 0
0 0 0 0 50 100 150 200 250 300 350 0
0 50Outlet
100Pressure
150 –200
bar (psi)
250 300 350 (700) (1500) (2200) (2900) (3600) (4400) (5000)350
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500)
Outlet (2200)
Pressure – (2900) (3600) (4400) (5000)
bar (psi)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 37
Performance

Industrial
PVM057

Delivery and Efficiency at 1000 r/min Case


CaseFlow
FlowVersus
VersusOutlet
OutletPressure
PressureatatFull
FullFlow,
Flow,1800
1800r/min
r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C
50°C(120°F)
(120°F)and
and1.0
1.0bar
barabsolute
absolute(0(0psipsigauge)
gauge)Inlet
Inlet
100 5 (1.32)
5 (1.32)
Delivery and Efficiency at 1000
Volumetric r/min
Efficiency
90 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
Overall Efficiency
Volumetric Efficiency
80 4 (1.06)
4 (1.06)
90
70 Overall Efficiency

Case Flow – l/min (USgpm)


Case Flow – l/min (USgpm)
80
Efficiency – %

60 3 (0.79)
3 (0.79)
70

Delivery – l/min (USgpm)


50
Efficiency – %

60
40 80 (21) 2 (0.53)
2 (0.53)
Delivery – l/min (USgpm)
50
30 60 (16)
40 80 (21)
20 Delivery (effective flow) 40 (11) 1 (0.26)
60 (16) 1 (0.26)
30
10 20 (5)
20 Delivery (effective flow) 40 (11)
0 0 00
0 10 50 100 150 200 250 300 350 20 (5) 00 5050 100 100 150 150 200 200 250250 300 300 350350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700)
(700)(1500)
(1500)(2200)
(2200)(2900) (3600)
(2900) (3600)(4400) (5000)
(4400) (5000)
0 Outlet Pressure – bar (psi) 0 Outlet
0 50 100 150 200 250 300 350 OutletPressure
Pressure– –bar
bar(psi)
(psi)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet
Input Torque andPressure
Power at– bar
1000(psi)
r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
330 (2921)
Input Torque and Power at 1000 r/min Case
CaseFlow
FlowVersus
VersusOutlet
OutletPressure
PressureatatCutoff,
Cutoff,1800
1800r/min
r/min
300 (2655) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C
50°C (120°F) and 1.0 bar absolute (0 psi gauge)Inlet
(120°F) and 1.0 bar absolute (0 psi gauge) Inlet
330 (2921) 1,1
1,1(0.29)
(0.29)
270 (2390)
300 (2655) Input Torque,
Input Torque – Nm (in.lb.)

240 (2124) Full Stroke


270 (2390) 1,0
1,0(0.26)
(0.26)
210 (1859) Input Torque,
Case Flow – l/min (USgpm)
Case Flow – l/min (USgpm)
Input Torque – Nm (in.lb.)

240 (2124) Full Stroke


180 (1593) 0,9
210 (1859) 0,9(0.24)
(0.24)
150 (1328)
Input Power – kW (hp)

180 (1593)
120 (1062) Input Power, 40 (54) 0,8
0,8(0.21)
(0.21)
150 (1328) Full Stroke
Input Power – kW (hp)

90 (797) 30 (40)
120 (1062) Input Power, 40 (54)
60 (531) Full Stroke 20 (27) 0,7
0,7(0.18)
(0.18)
90 (797) 30 (40)
30 (266) 10 (13)
60 (531) 20 (27) 0,6
0 0 0,6(0.16)
(0.16)
0
30 (266) 50 100 150 200 250 300 350 10 (13)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
0 Outlet Pressure – bar (psi) 0 0,5
0,5(0.13)
(0.13)
0 50 100 150 200 250 300 350 00 5050 100 100 150 150 200 200 250250 300 300 350350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700)
(700)(1500)
(1500)(2200)
(2200)(2900) (3600)
(2900) (3600)(4400) (5000)
(4400) (5000)
Outlet Pressure – bar (psi) Outlet
OutletPressure
Pressure– –bar
bar(psi)
(psi)

38 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM057

Typical Noise Levels Delivery and Case Flow Versus Speed


Petroleum Oil (10W) at 93°C (200°F), @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
1.0 bar absolute (0 psi gauge) Inlet 150 (40)
82 140 (37)
Delivery and Case 50Flow Versus
bar (700 psi),Speed
130 (34)
@ 93°C (200°F), full flow and Delivery
1.0 bar absolute (0 psi) gauge Inlet
78 2500 r/min
120150(32)(40)
Max. Flow 2500 r/min
Min. Flow 110 (29)(37)
140
74 50 bar (700 psi),
100130(26)(34) Delivery
Noise Level – dBA

90120(24)(32) 280 bar (4000 psi),


70

Case Flow – l/min (USgpm)


80110(21)(29) Delivery
66 70100(18)(26)
90 (24)
60 (16) 280 bar (4000 psi), 6,0 (1.6)
280 bar (4000 psi),
Case flow

Case Flow – l/min (USgpm)


62 80 (21)
50 (13) Delivery 5,0 (1.3)
600 r/min 40 (11)
70 (18) 4,0 (1.1)
Max. Flow 280 bar (4000 psi), 6,0 (1.6)
58 3060 (8)(16) 3,0 (0.8)
600 r/min Case flow
2050 (5)(13) 50 bar (700 psi), 2,0 (0.5)5,0 (1.3)
Min. Flow Case flow 4,0 (1.1)
54 1040 (3)(11) 1,0 (0.3)
300 (8) 0 3,0 (0.8)
50 0
20 (5) 500 1000 1500 2000
50 bar 2500
(700 psi), 2,0 (0.5)
0 50 100 150 200 250 300 Speed – r/min Case flow 1,0 (0.3)
(700)(1500) (2200) (2900) (3600) (4400) 10 (3)
Outlet Pressure – bar (psi) 0 0
0 Input
500 Torque Versus1500
1000 Speed 2000 2500
(Sound pressure @ 93°C (200°F), full flow and
data equivalent to NFPA) Speed – r/min
1.0 bar absolute (0 psi gauge) inlet
320 (2832)
Input Torque Versus Speed320 bar
Overall Efficiency Versus Speed 300 (2655)
@ 93°C (200°F), full flow and(4600 psi)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet 280 (2478) 1.0 bar absolute (0 psi gauge) inlet
95 280 bar
260320
(1858)(2832) (4000
50 bar 320psi)
bar
Input Torque – Nm (in.lb.)

(700 psi) 240300


(2124)(2655) 250(4600
bar psi)
220280
(1947)(2478) (3600 psi)
90 280 bar
100 bar 200260
(1770)(1858)
(1500 psi) 200(4000
bar psi)
180240
(1593)
Input Torque – Nm (in.lb.)

(2124) (2900
250psi)
bar
150 bar 160220
(1416)(1947)
85 (2200 psi) (3600 psi)
150 bar
Efficiency – %

140200
(1239)(1770) (2200
200psi)
bar
200 bar 120180
(1062)(1593)
(2900psi) 100 (2900
bar psi)
80 100160
(885)
(1416)
(1500 psi)
150 bar
80140
(708)
(1239)
(2200 psi)
50 bar
60120
(531)
(1062)
75 (700100
psi)bar
250 bar 40100
(354)(885)
17 bar
(1500 psi)
(3600 psi) 20 (177)
80 (708) (250 psi)
70 600(531) 50 bar
0 500 1000 1500 2000 2500 (700 3000psi)
280 bar 40 (354) Speed – r/min
(4000 psi) 17 bar
20 (177)
65 (250 psi)
0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500 3000
Speed – r/min Speed – r/min

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 39
Performance

Mobile
PVM057

Input Power Versus Speed


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
78 (105) 320 (4600)
72 (97)

Input Power @ Full Flow – kW (hp)


280 (4000)
66 (89)
60 (80) 250 (3600)

Pressure – bar (psi)


54 (72)
200 (2900)
48 (64)
42 (56)
150 (2200)
36 (48)
30 (40)
100 (1500)
24 (32)
18 (24)
50 (700)
12 (16)
6 (8) 17 (250)
0
0 500 1000 1500 2000 2500
Speed – r/min
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet

Case Flow – l/min (USgpm)


6 (53)
Input Torque – Nm (in.lb.)

20 bar (300 psi)


5 (44) differential,
11 bar (160 psi) Input Torque
4 (35) differential, 8.0 (2.11)
Input Torque
3 (27) 6.0 (1.58)
2 (18) 4.0 (1.06)
11 bar (160 psi) differential,
1 (9) Case Flow 2.0 (0.53)
20 bar (300 psi) differential, Case Flow
0 0
0 500 1000 1500 2000 2500
Speed – r/min
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
100 (885)
280 bar (4000 psi)
Case Flow – l/min (USgpm)
Input Torque – Nm (in.lb.)

90 (796)
Input Torque
80 (708)
70 (619)
280 bar
60 (531)
(4000 psi)
50 (442) Case Flow 10 (2.6)
40 (354) 8 (2.1)
30 (265) 150 bar (2200 psi), Case Flow 6 (1.6)
20 (177) 4 (1.1)
150 bar (2200 psi), Input Torque
10 (88) 2 (0.5)
0 500 1000 1500 2000 2500
Speed – r/min

40 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM063
Typical Noise Levels at 1800 and 1200 r/min. with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
75
1800
Typical r/minLevels at 1800 and 1200 r/min. with
Noise Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF), D
max. flow Delivery
and and Efficiency
1.0 bar absoluteat (0
1800psir/min,
gauge)50ϒ C (120ϒF),
Inlet
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
70 and 1.0 bar absolute (0 psi gauge) Inlet
absolute (0 psi gauge) Inlet 100
100 Volumetric Efficiency
75 1200 r/min Volumetric Efficiency
1800 r/min max. flow 90
dBA Level – dBA

1800
min. flowr/min 90 Overall Efficiency
65 max. flow Overall Efficiency
80
70 80
1200 r/min 70
70

Efficiency – %
1800 r/min max. flow

Efficiency – %
Noise Level –Noise

60 min. flow 60 120 (32)


60 120 (32)
65

Delivery – l/min (USgpm)


Delivery (effective flow)
1200 r/min 50 100 (26)

Delivery – l/min (USgpm)


Delivery (effective flow)
min. flow 50 100 (26)
55 40 80 (21)
40 80 (21)
60
30 60 (16)
30 60 (16)
50 1200 r/min
50 100 150 min.
200 flow 250 20 40 (11)
0 20 40 (11)
55 (700) (1500) (2200) (2900) (3600)
10 20 (5)
Outlet Pressure – bar (psi) 10 20 (5)
0 0
50 00 50 100 150 200 250 0
0 50 100 150 200 250 0 50 (1500)
(700) 100 (2200)150 (2900)200 (3600)250
(700) (1500) (2200) (2900) (3600) (700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),


Typical Noise Levels at 1500 and 1000 r/min. with Inputand
Torque
1.0 and Power at (0
bar absolute 1800
psi r/min,
gauge)50ϒC (120ϒF),
Inlet
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar and 1.0 bar absolute (0 psi gauge) Inlet
absolute (0 psi gauge) Inlet 270 (2390)
270 (2390)
240 (2124)
240 (2124)
75Typical Noise Levels at 1500 and 1000 r/min. with Input Torque,
Input Torque,
Input Torque – Nm (in.lb.)

Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar 210 (1859) Full Stroke
Input Torque – Nm (in.lb.)

1500 r/min
absolute (0 psi gauge) Inlet 210 (1859) Full Stroke
max. flow 180 (1593)
70 180 (1593)
1000 r/min 150 (1328) 50 (67)
dBA Level – dBA

75 max. flow 50 (67)


Input Power – kW (hp)
150 (1328)
65 1500 r/min 120 (1062) 40 (54) Input Power – kW (hp)
1500 r/min max. flow 120 (1062) 40 (54)
70 min. flow Input Power, 30 (40)
90 (1327)
1000 r/min 90 (1327) Input
Full Power, 30 (40)
Stroke
Noise Level –Noise

60 max. flow Full Stroke


60 (531) 20 (27)
65 1000 r/min 60 (531) 20 (27)
1500 r/min min. flow Input Torque,
min. flow 30 (226) Input Torque,
Cut-off 10 (13)
55 30 (226) Cut-off 10 (13)
60 0 0
0 50 100 150 200 250 0
50 1000 r/min 0 50 (1500)
(700) 100 (2200)
150 (2900)
200 (3600)
250
0 50 100 min. flow
150 200 250 (700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
55 (700) (1500) (2200) (2900) (3600) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)
Sound pressure data
50 equivalent to NFPA.
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 41
Sound pressure data
Performance

Industrial
PVM063

Deliveryand
andEfficiency
Efficiencyatat1200
1200r/min,
r/min,50ϒ
50ϒ Delive
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF), Delivery CC(120ϒ
(120ϒF),
F), Delive
Delivery
andand
1.0Efficiency at 1500
bar absolute (0 psir/min, 50ϒC
gauge) (120ϒF),
Inlet and1.0
and 1.0bar
barabsolute
absolute(0 (0psi
psigauge)
gauge)Inlet
Inlet
and 1.0 bar absolute (0 psi gauge) Inlet
100 100
100 100
100 Volumetric Efficiency VolumetricEfficiency
Efficiency 100
Volumetric Efficiency Volumetric
90 90
90 90
90 OverallEfficiency
Efficiency 90
Overall Efficiency Overall
80 Overall Efficiency 80
80 80
80 80
70 70
70 70
70 70

Efficiency––%%

Efficiency––%%
Efficiency– –%%

60 60
60 60
60
60

Efficiency

Efficiency
Efficiency
Delivery – l/min (USgpm)

50 50 100(26)
(26) 50
(USgpm)
100 (26)

(USgpm)
50 100 50

-l/min(USgpm)
50 100 (26) l/min(USgpm)
40 Delivery (effective flow) 80 (21) 40
40 80(21)
(21) 40
40
40 Delivery (effective flow) 80 (21) 80
Delivery(effective
Delivery (effectiveflow)
flow)
30 60 (16) 30
30 60(16)
(16) 30
30
30 60

Delivery-l/min
60 (16)
Delivery– –l/min

20 40 (11) 20
20 40(11)
(11) 20
20
40
20 40 (11)

Delivery
10 20(5)
(5) 10
Delivery

10 20 (5) 10 20 10
10 20 (5)
0 0 00 00 00
00 50 100 150 200 2500 00 50
50 100
100 150
150 200
200 250
250 0
0 50
(700) 100
(1500) 150
(2200) 200
(2900) 250
(3600) (700) (1500)
(700) (1500) (2200)
(2200) (2900)
(2900) (3600)
(3600)
(700) (1500) (2200) (2900) (3600) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),


Input Torque InputTorque
Torqueand
andPower
Powerat
at1200
1200r/min,
r/min,50ϒ
50ϒ
CC(120ϒ
(120ϒF), In
and 1.0and
barPower at 1500
absolute r/min,
(0 psi 50ϒInlet
gauge) C (120ϒF), Input F), In
and 1.0 bar absolute (0 psi gauge) Inlet and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet
270 (2390)
270 (2390) 270(2390)
270 (2390) 27
27
240 (2124)
240 (2124) 240(2124)
240 (2124) 24
24
Input Torque,
(in.lb.)

Input Torque, InputTorque,


Torque,

(in.lb.)
210 (1859)
(in.lb.)

Full Stroke Input

Nm(in.lb.)
Nm(in.lb.)
Nm(in.lb.)

210 (1859) Full Stroke 210(1859)


(1859) FullStroke
Stroke 21
21
210 Full
180 (1593)
180 (1593) 180(1593)
(1593) 18
18
180

Torque––Nm
Torque––Nm
Torque– –Nm

150 (1328) 50 (67)


150 (1328) 50 (67) 50(67)
(67) 15
(hp)

150(1328)
150 (1328) 50 15
kW(hp)

InputTorque
InputTorque

(hp)
InputTorque

120 (1062) 40 (54)


kW(hp)

120 (1062) 40 (54) 120(1062)


(1062) 40(54)
(54) 12
40 12
Power– –kW

120
Power––kW

90 (1327) 30 (40) Input


30 (40)
Input

90 (1327)
Input

90(1327)
90 (1327) 30(40)
30 (40) 99
InputPower

60 (531) Input Power, 20 (27)


InputPower

60 (531) Input Power, 20 (27)


Full Stroke
Full Stroke 60(531)
60 (531) 20(27)
20 (27)
InputPower,
Input Power,
30 (226) 10 (13)
Input

30 (226) 10 (13) FullStroke


Full Stroke
30(226)
(226) 10(13)
(13)
Input

30 10
0 0
00 50 100 150 200 2500
0 50 (1500)
(700) 100 (2200)
150 (2900) 250
200 (3600) 00 00
(700) (1500) (2200) (2900) (3600) 00 50
50 100 150
100 150 200 200 250 250
Outlet Pressure – bar (psi) (700) (1500)
(700) (1500) (2200)
(2200) (2900) (3600)
(2900) (3600)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

42 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM063

Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),


Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF), Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
100 5 (1.32)
100 Volumetric Efficiency
Volumetric Efficiency
90
90
Overall Efficiency 4 (1.06)
80 Overall Efficiency

Case Flow l/min - (USgpm)


80
70
70
Efficiency – %
Efficiency – %

60 3 (0.79)
60

Delivery – l/min (USgpm)


) 50 100 (26)

Delivery – l/min (USgpm)


Delivery -l/min (USgpm)

26) 50 100 (26)


Delivery -l/min (USgpm)

40 80 (21) 2 (0.53)
1) 40 80 (21)
30 60 (16)
6) 30 60 (16)
Delivery (effective flow) 1 (0.26)
20 Delivery (effective flow) 40 (11)
1) 20 40 (11)
10 20 (5)
) 10 20 (5)
0
0 0 0 50 100 150 200 250
0
0 50 100 150 200 250 0 (700) (1500) (2200) (2900) (3600)
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600) Outlet Pressure - bar (psi)
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

, Input Torque and Power at 1000 r/min, 50ϒC (120ϒF), Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
ϒF), Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet
12 (3.17)
270 (2390)
270 (2390) 11 (2.91)
240 (2124) 10 (2.64)
240 (2124)
Input Torque – Nm (in.lb.)

Input Torque,
Case Flow l/min - (USgpm)
Input Torque – Nm (in.lb.)

210 (1859) Input Torque, 9 (2.38)


210 (1859) Full Stroke
Full Stroke
180 (1593) 8 (2.11)
180 (1593)
7 (1.85)
) 150 (1328) 50 (67)
67) 150 (1328) 50 (67) 6 (1.59)
Input Power – kW (hp)

Input Power – kW (hp)


Input Power – kW (hp)

Input Power – kW (hp)

) 120 (1062) 40 (54)


54) 120 (1062) 40 (54) 5 (1.32)
) 90 (1327) 30 (40) 4 (1.06)
40) 90 (1327) 30 (40)
3 (0.79)
) 60 (531) 20 (27)
27) 60 (531) 20 (27)
Input Power, 2 (0.53)
) 30 (226) Input
Full Power,
Stroke 10 (13)
13) 30 (226) Full Stroke 10 (13) 1 (0.26)
0 0 0
0 0 0 50 100 150 200 250
0 50 100 150 200 250
0 (700)50(1500)
100(2200)
150(2900) 250
200(3600) (700) (1500) (2200) (2900) (3600)
(700) (1500) (2200) (2900) (3600) Outlet Pressure - bar (psi)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 43
Performance
TypicalTypical Noise at
Noise Levels Levels
2500at
& 2500 & 600with
600 r/min r/min with Petroleum
Petroleum Oil (10W)
Oil (10W)
Mobile at 93°Cat 93°C (200°F)
(200°F) and 1.0and
bar 1.0 bar absolute
absolute (0 psi gauge)
(0 psi gauge) Inlet Inlet
PVM063 85 85
2500 r/min
2500 r/min
min. flow
min. flow
80 80
2500 r/min
2500 r/min
max. flow
max. flow
Noise Level – dBA

75
Noise Level – dBA

75 Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
85
70 70
2500 r/min
min. flow
65 65 80
600 r/min r/min
600 2500 r/min
max. flow
max. flow max. flow
60 60

Noise Level – dBA


75
600 r/min
600 r/min
55 55 min. flow
min. flow
70
50 50
0 0 50 50100 100
150 150
200 200
25065 250
(700) (700)(1500) (1500)
(2200) (2200)
(2900) (2900)
(3600) (3600) 600 r/min
Outlet Pressure
Outlet Pressure – bar (psi)
– bar (psi) max. flow
Sound pressure
Sound pressure data data 60
equivalent
equivalent to NFPA.to NFPA. 600 r/min
55 min. flow

50
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.

OverallOverall Efficiency
Efficiency versus versus
Speed Speed DeliveryDelivery
and Case andFlow
Case Flow versus
versus Speed atSpeed
93°Cat 93°C (200°F),
(200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge)
t 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet inlet Full
Full Flow 1.0Flow
bar 1.0 bar absolute
absolute (0 psi gauge)
(0 psi gauge) Inlet Inlet

160 (42)160 (42)


00 100

95 95 140 (37)140 (37)


50 bar
50 bar (725 psi)(725 psi)
50 bar
50 bar (725 psi)(725 psi)
90 90 120 (32)120 (32) DeliveryDelivery
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)

100 bar100 bar Overall Efficiency versus Speed Delivery and Case Flow
85 85 psi)
(1450 (1450 psi) at 93°C (200°F) and100
1.0(26)
bar100
absolute
(26) (0 psi gauge) inlet Full Flow 1.0 bar ab
Overall Efficiency (%)

Case Flow – l/min (USgpm)


Case Flow – l/min (USgpm)

80 80 210 bar210 barpsi)


(3000 (3000 psi)
80 (21) 80 (21) 160 (42)
100 DeliveryDelivery
75 75
150 bar150 bar
(2200 (2200 psi) 95
psi) 60 (16)
60 (16) 8140 (37)8 (2.11)
(2.11)
70 70 psi) 50 bar (725
50 bar
65 65 90 40 (11) 40 (11)
6120 (32)6 (1.59)
(1.59) Deliver
Delivery – l/min (USgpm)

230 bar230 barpsi)


(3300 (3300 psi) 100 bar 210 bar210 barpsi)
(3000 (3000 psi)
Case Case Flow
Flow
60 21060bar210 bar 85 4 (1.06) 4 (1.06)
(1450 psi) 100 (26)
Overall Efficiency (%)

(3000 psi)
(3000 psi) 20 (5) 20 (5)
80 50 bar
50 bar (725 psi)(725 psi)
Case 2 (0.53) 2 (0.53)
Case Flow
Flow
55 55
80 (21)0
0
50 50 75
0 0
500 500
1000 1000
1500 1500
2000 2000
2500 30001503000
2500 bar 0 0
500 500 1500
1000 1000 2000
1500 2500
2000 3000
250060 (16)
3000
Speed – r/min r/min
Speed – 70 (2200 psi) Speed (r/min)
Speed (r/min)
65 40 (11)
230 bar (3300 psi) 210 b
60 210 bar
(3000 psi) 20 (5)
55 50 ba

50
0 500 1000 1500 2000 2500 3000 0 500 1000
44 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Speed – r/min Sp
Performance

Mobile
PVM063

Input
Input
Torque
Torque
versus
versusSpeed
Speed
at at
93°C93°C
(200°F),
(200°F), Input
Input
Power
Power
versus
versusSpeed
Speedat at
93°C
93°C(200°F),
(200°F),
Full
Full
Flow
Flow
and
and
1.01.0
barbar
absolute
absolute
(0 (0
psipsi
gauge)
gauge)
Inlet
Inlet Full
Full
Flow
Flow
and
and
1.01.0
barbar
absolute
absolute
(0 (0
psipsi
gauge)
gauge)Inlet
Inlet

300
300 Input
Input Torque
(2655)
(2655) Torque versus
versus Speed
Speed at
at 93°C
93°C (200°F),
(200°F), 100
100
(134)
(134)Input
Input Power
Power versus
versus Speed
Speed at
at 93°C
93°C (200°F),
(200°F),
Full
Full Flow
Flow and
and 1.0
1.0 bar
bar absolute
absolute (0
(0 psi
psi gauge)
gauge) Inlet
Inlet Full
Full Flow
Flow and
and 1.0
1.0 bar
bar absolute
absolute (0
(0 psi
psi gauge)
gauge) Inlet
Inlet
9090
(121)
(121)
300
300 (2655)
(2655) 100
100 (134)
(134)
250
250
(2212)
(2212) 8080
(107)
(107)
230
230 barbar (3300
(3300 psi)
psi)
90
90 (121)
(121)
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)

210
210 barbar (3000
(3000 psi)
psi) 230
230
barbar
(3300
(3300psi)
psi)

Input Power – kW (hp)


Input Power – kW (hp)
250 (2212) 7070(94)
(94) 210
210
barbar
(3000
(3000psi)
psi)
200 250
200 (2212)
(1770)
(1770) 80 (107)
80 (107)
230
230 bar
bar (3300
(3300 psi)
psi)
Input Torque – Nm (in.lb.)

210
210 bar
bar (3000
(3000 psi)
psi) 6060 (80)(80) 230
230 bar
bar (3300
(3300 psi)
psi)

Input Power – kW (hp)


150
150 barbar (2200
(2200 psi)
psi) 70
70 (94)
(94) 210 bar (3000 psi)
200
200 (1770)
(1770) 210 bar (3000 psi)
150150 (1327)
(1327) 5050 (67)(67)
60
60 (80)
(80) 150 150barbar(2200
(2200psi)
psi)
150
150 bar bar (2200
(2200 psi)
psi) 4040 (54)(54)
150
150 (1327)
(1327) 100 100 barbar (1500
(1500 psi)
psi) 50
50 (67)
(67)
100 100 (885)
(885)
3030 (40)(40) 100 100barbar
150
150 (1500
bar
bar (1500psi)
(2200
(2200 psi)
psi)
psi)
40
40 (54)
(54)
5050 100
100
bar bar bar
bar
(725(725(1500
(1500 psi)
psi) psi)
psi)
100
100 (885)
(885) 2020 (27)(27)
5050 (442)
(442) 30
30 (40)
(40) 5050 100
100
barbar bar
bar
(725
(725(1500
psi) psi)
(1500
psi) psi)
1717 barbar (250(250 psi)
psi) 1010 (13)(13)
50
50 barbar (725
(725 psi)
psi) 20
20 (27)
(27) 1717 barbar(250
(250 psi)
psi)
50
50 (442)
(442)
0 0 50
50 bar
bar (725
(725 psi)
psi)
0 0
0 0 500 5001000 10001500 15002000200025002500300017
173000
bar
bar (250
(250 psi)
psi) 10
10 (13)
0 0 500
(13) 5001000 10001500 15002000 20002500 25003000 3000
17
17 bar
bar (250
(250 psi)
psi)
00 Speed
Speed (r/min)
(r/min) Speed
Speed (r/min)
(r/min)
00
00 500 500 10001000 1500 1500 2000
2000 25002500 30003000 00 500
500 10001000 1500 1500 2000 2000 25002500 3000 3000
Speed
Speed (r/min)
(r/min) Speed
Speed (r/min)(r/min)
InputInput Torque
Torque and andCase
Case FlowFlowversus
versus Speed
Speed Input
Input Torque
Torque andand Case
Case FlowFlow versus
versus Speed
Speed
at at
93°C93°C (200°F),
(200°F), Load
Load Sense
Sense Standby
Standby andand at at
93°C93°C (200°F),
(200°F), Pressure
Pressure Limit
Limit Cut-off
Cut-off andand 1.01.0
bar bar
1.01.0
barbar absolute
absolute (0 (0
psipsigauge)
gauge) Inlet
Inlet absolute
absolute (0 (0
psipsigauge)
gauge) Inlet
Inlet
Input
Input Torque
Torque and and Case
Case FlowFlow versus
versus Speed
Speed Input
Input Torque
Torque andand CaseCase FlowFlow versus
versus Speed
Speed
8 (71)
8 (71) at at 93°C
93°C (200°F),
(200°F), LoadLoad Sense
Sense Standby
Standby 20.0
20.0
and
and (5.28)
(5.28) 8080
(708)
(708)
at
at 93°C
93°C (200°F),
(200°F), Pressure
Pressure Limit Limit Cut-off
Cut-off and 20.0
and 20.0
1.0
1.0(5.28)
(5.28)
bar
bar
1.0
1.0 bar
bar absolute
absolute (0 (0 psi
psi gauge)
gauge) Inlet
Inlet absolute
absolute
210
210barbar (0
(0 psi
(3000
(3000psi
psi) gauge)
gauge)
psi)
InputInput Inlet
Inlet
Torque
Torque
18.0
18.0 (4.76)
(4.76) 7070
(619)
(619) 18.018.0(4.76)
(4.76)
7 (62)
7 88
(62)
(71)
(71) 20.0
20.0 (5.28)
(5.28) 80
80 (708)
(708) 20.0
20.0 (5.28)
(5.28)
16.0
16.0 (4.23)
(4.23) 16.016.0(4.23)
(4.23)
Case Flow – l/min (USgpm)
Case Flow – l/min (USgpm)

Case Flow – l/min (USgpm)


Case Flow – l/min (USgpm)
2020 barbar
(300(300psi)
psi) 210
210
210210 bar
bar
barbar(3000
(3000
(3000
(3000 psi)
psi)
psi)psi) Input
Input
CaseCase Torque
Torque
Flow
Flow
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)

6 (53)
6 77
(53) 18.0
18.0 (4.76)
(4.76) 6060
(531)
70(531) 18.0
18.0 (4.76)
(4.76)
(62)
(62) diff.
diff.
Input
Input Torque
Torque 70 (619)
(619)
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)

14.0
14.0 (3.70)
(3.70) 14.014.0(3.70)
(3.70)
16.0
16.0 (4.23)
(4.23) 16.0
16.0 (4.23)
(4.23)
Case Flow – l/min (USgpm)

Case Flow – l/min (USgpm)


20
20 bar
bar (300
(300 psi)
psi) 5050
(442)
(442) 210
210 bar
bar (3000
(3000 psi)psi) Case
Case Flow
Flow
Input Torque – Nm (in.lb.)

5 (44)
5 66
(44)
(53)
(53) 12.0
12.0 (3.17)
(3.17) 60
60 (531)
(531) 12.012.0(3.17)
(3.17)
diff.
diff. Input
Input Torque
Torque
Input Torque – Nm (in.lb.)

14.0
14.0 (3.70)
(3.70) 150 150
barbar(2200
(2200psi)psi) 14.0
14.0 (3.70)
(3.70)
4 (35)
4 (35) 10.0
10.0 (2.64)
(2.64) 4040
(354)
50(354)
(442) CaseCaseFlow Flow 10.010.0(2.64)
(2.64)
55 (44)
(44) 11 11
barbar(160
(160psi)
psi)
diff.
diff. 50 (442)
12.0
12.0 (3.17)
(3.17) 12.0
12.0 (3.17)
(3.17)
Input
InputTorque
Torque
8.08.0(2.11)
(2.11) 3030
(265)
(265) 150
150 bar
bar (2200
(2200 8.08.0
psi)
psi) (2.11)
(2.11)
3 (27)
3 4(27) 10.0 (2.64) 40
40 (354)
(354) 10.0
10.0 (2.64)
4 (35)
(35) 2020 barbar (300
(300 psi) 11
psi) 11 bar
bar (160
(160 psi) diff. 10.0 (2.64)
psi) diff. Case
Case FlowFlow (2.64)
6.06.0(1.59)
(1.59) 6.06.0(1.59)
(1.59)
diff.
diff.
Case
Case Flow Input
Flow Input Torque
Torque
8.0
8.0 (2.11) 2020
(177)
(177) 8.0
2 (18)
2 (18) (2.11) 30
30 (265)
(265) 8.0 (2.11)
(2.11)
33 (27)
(27) 4.04.0(1.06)
(1.06) 150150
barbar
(2200
(2200 psi)psi)
Input
Input Torque
Torque 4.04.0 (1.06)
(1.06)
20
20 bar
bar (300
(30011 psi)
psi)
11
barbar(160
(160psi)
psi)
diff.
diff. 6.0
diff. 6.0 (1.59)
(1.59) 1010
(88)(88) 6.0
6.0 (1.59)
(1.59)
1 (9)
12 (9) diff. Case
Case FlowFlow
Case
Case FlowFlow 2.02.0
(.53)
(.53) 20
20 (177)
(177)
2 (18)
(18) 2.02.0(.53)
(.53)
4.0
4.0 (1.06)
(1.06) 150
150 bar
bar (2200
(2200 psi) psi) Input
Input Torque
Torque 4.0 4.0 (1.06)
(1.06)
11
11 bar
bar (160
(160 psi)
psi) diff.
diff.
0 0
110(9)
(9) Case
Case Flow
Flow 10
10 (88)
(88)
0 0 500 500 100010001500 15002000 20002500 25003000 3000
0 500 5001000 10001500 1500 20002000 2500
25003000 3000 2.0 2.0 (.53)
(.53) 2.0
2.0 (.53)
(.53)
Speed
Speed (r/min)
(r/min) Speed
Speed (r/min)
(r/min)
00
00 500
500 1000 1000 1500 1500 20002000 2500
2500 3000 3000 00 500
500 10001000 1500 1500 2000 2000 2500 2500 3000 3000
Speed
Speed (r/min)
(r/min) Speed
Speed (r/min)
(r/min)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 45
Performance

Industrial
PVM074

Typical Noise Levels at 1800 and 1200 r/min


with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
76 Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F) Delivery and Efficiency at 1800 r/min
1800 r/min Delivery
74 and 1.0 bar absolute (0 psi gauge)
Max.Inlet
Flow 50°C (120°F) and 1.0and
barEfficiency
absolute (0 atpsi
1800 r/minInlet
gauge)
76 100 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
72 100
Volumetric Efficiency
74 1800 r/min 90 Volumetric Efficiency
1800 Flow
Max. r/min 90 Overall Efficiency
Level – dBA

70 Min. Flow Overall Efficiency


72 80
80
68 1800 r/min 70
– dBA

70 Min. Flow 70

Efficiency – %
66 60 150 (40)

Efficiency – %
Noise

68 60 Delivery (effective flow) 150 (40)


Noise Level

1200 r/min Delivery (effective flow)


64

Delivery – l/min (USgpm)


Max. Flow 50 125 (33)

Delivery – l/min (USgpm)


66 50 125 (33)
62 40 100 (26)
1200 r/min 40 100 (26)
64 Max. Flow
60 30 75 (20)
1200 r/min 30 75 (20)
62 Min. Flow 50 (13)
58 20
20 50 (13)
0 50 100 150 200 250 300
60 1200 r/min
(700) (1500) (2200) (2900) (3600) (4400) 10 25 (7)
Min. Flow 10 25 (7)
58 Outlet Pressure – bar (psi) 0 0
0Sound pressure
50 data 150
100 200 250 300 0 0 50 100 150 200 250 300 350 0
(700)to (1500)
equivalent NFPA. (2200) (2900) (3600) (4400) 0(700) 50
(1500)100
(2200)150 200
(2900) (3600)250
(4400) 300 350
(5000)
(700) (1500) (2200) (2900)
Outlet Pressure – bar (psi)(3600) (4400) (5000)
Outlet Pressure – bar (psi)
Sound pressure data Outlet Pressure – bar (psi)
equivalent to NFPA.

Input Torque and Power at 1800 r/min


Typical Noise Levels at 1500 and 1000 r/min 50°C (120°F)Input
andTorque
1.0 barand Power(0atpsi
absolute 1800 r/minInlet
gauge)
with Petroleum Oil (10W) at 50°C (120°F) 400 (3540) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet 400 (3540)
72 Typical Noise Levels at 1500 and 1000 r/min 360 (3186) Input Torque,
360 (3186) FullInput Torque,
Stroke
with Petroleum Oil (10W) at 50°C (120°F) Full Stroke
Input Torque – Nm (in.lb.)

70 1000
and 1.0 bar absolute (0 psi gauge) r/min
Inlet 320 (2832)
Input Torque – Nm (in.lb.)

Min. Flow 320 (2832)


72
280 (2478)
68 280 (2478)
70 1000 r/min
Level – dBA

Min. Flow 240 (2124)


66 1500 r/min 240 (2124)
68 Max. Flow 200 (1770)
200 (1770) Input Power,
Input Power – kW (hp)

1500 r/min
– dBA

64
FullInput Power, 80 (107)
Input Power – kW (hp)

66 1500 r/min Min. Flow 160 (1416) Stroke


160 (1416) Full Stroke 80 (107)
Noise

62 Max. Flow 120 (1062) 60 (80)


Noise Level

64 1500 r/min 120 (1062) 60 (80)


Min.
1000Flow
r/min Input Torque, 40 (54)
60 80 (708) Input Torque,
Max. Flow 80 (708) Cut-off 40 (54)
62 Cut-off
40 (354) 20 (27)
58 1000 r/min 40 (354) 20 (27)
60 Max. Flow 0 0
56 0 0 50 100 150 200 250 300 350 0
58 0 50 100 150 200 250 300 0(700) 50
(1500)100
(2200)150
(2900)200
(3600)250 300
(4400) 350
(5000)
(700) (1500) (2200) (2900) (3600) (4400) (700) (1500)
Outlet (2200)– (2900)
Pressure (3600) (4400) (5000)
bar (psi)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)
56
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Outlet Pressure – bar (psi)

46 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM074

Delivery and Efficiency at 1500 r/min Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery and Efficiency at 1200 r/min
100 Delivery and Efficiency at 1500 r/min 100
Volumetric Efficiency
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge)
Volumetric Inlet
Efficiency
90 100 90 100
Overall Efficiency Overall Efficiency Volumetric Efficiency
Volumetric Efficiency
80 90 80 90 Overall Efficiency
Overall Efficiency
70 80 70 80
Efficiency – %

Efficiency – %
60 70 60 70

Efficiency – %
Efficiency – %

60

Delivery – l/min (USgpm)


125 (33)

Delivery – l/min (USgpm)


50 60 50 125 (33)
Delivery (effective flow)

Delivery – l/min (USgpm)


40 50 100125
(26)(33) 40 50 125 (33)
100 (26)

Delivery – l/min (USgpm)


Delivery (effective flow)
Delivery (effective flow)
30 40 75 100
(20)(26) 30 40 75 (20)100 (26)
Delivery (effective flow)

20 30 50 75
(13)(20) 20 30 50 (13)75 (20)

10 20 25 50
(7)(13) 10 20 25 (7) 50 (13)
0 10 0 25 (7) 0 10 0 25 (7)
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400)(5000) 0 (1500) (2200) (2900) (3600) (4400) (5000)
(700) 0
0 0 0 Outlet
50 Pressure
100 150
0 50Outlet
100Pressure
150 – 200
bar (psi)
250 300 350 – bar 200
(psi) 250 300 350
(700) (1500) (2200) (2900) (3600) (4400)(5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min


50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet Input Torque and Power at 1200 r/min
400 (3540) Input Torque and Power at 1500 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet Input Torque and Power at 1200 r/min
400 (3540)
360 (3186)
400 (3540) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
400 (3540)
360 (3186) Input Torque,
320 (2832) Input Torque,
360 (3186) Full Stroke
Full Stroke 360 (3186) Input Torque,
320 (2832)
Input Torque – Nm (in.lb.)

280 (2478)
320 (2832) Input Torque, Full Stroke
Input Torque – Nm (in.lb.)

Full Stroke 320 (2832)


280 (2478)
Input Torque – Nm (in.lb.)

Input Torque – Nm (in.lb.)

240 (2124)
280 (2478)
280 (2478)
240 (2124)
200 (1770)
240 (2124)
240 (2124)
Input Power – kW (hp)

200 (1770)
160 (1416)
200 (1770) Input Power, 80 (107)
200 (1770) Input Power – kW (hp)
Full Stroke 160 (1416) 80 (107)
Input Power – kW (hp)

Input Power – kW (hp)


120 (1062)
160 (1416) 60 (80)
Input Power, 80 (107)
Full Stroke 160 (1416)
120 (1062) Input Power, 60 (80)80 (107)
80120
(708)
(1062) 40 (54)
60 (80) Full Stroke
120 (1062) Input Power, 60 (80)
80 (708) Full Stroke 40 (54)
40 (354)
80 (708) 20 40
(27)(54)
40 (354) 80 (708) 20 (27)40 (54)
400(354) 0 20 (27)
0 50 100 150 200 250 300 350 0 40 (354) 0 20 (27)
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 50 100 150 200 250 300 350
0 0
0 50Outlet
100Pressure
150 – bar
200 (psi)
250 300 350 0
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 Outlet
50 Pressure
100 150 200 250 300 350
– bar (psi)
Outlet Pressure – bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 47
Performance

Industrial
PVM074

Delivery and Efficiency at 1000 r/min Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F)Delivery
and 1.0 and
bar absolute (0at
psi1000
gauge) Inlet 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Efficiency r/min 5,0 (1.32)
100 50°C (120°F) and 1.0 bar absolute
Volumetric EfficiencyInlet
(0 psi gauge)
100 Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
90 Volumetric Efficiency 4,5 (1.19) 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Overall Efficiency 5,0 (1.32)
90 4,0 (1.06)
80 Overall Efficiency

Flow - l/min (USgpm)


80 3,54,5 (1.19)
(0.92)
70
70 3,04,0 (1.06)
Efficiency – %

60 (0.79)

Case Flow - l/min (USgpm)


Efficiency – %

50
60 2,53,5 (0.92)
(0.66)
50 Delivery – l/min (USgpm) 2,03,0 (0.79)
(USgpm)
40 100 (26) (0.53)
Delivery (effective flow)
40 100 (26) 1,52,5 (0.66)
Delivery – l/minCase
30 75 (20) (0.40)
Delivery (effective flow)
20
30 75 (20)
50 (13) 1,02,0 (0.53)
(0.26)

10
20 50 (13)
25 (7) 0,51,5 (0.40)
(0.13)
10 25 (7) 1,0 (0.26)
0
0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
0(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 0,5 (0.13) (700) (1500) (2200) (2900)(3600) (4400) (5000)
0 50
Outlet 100 150– bar
Pressure 200 250 300 350
(psi)(3600) Outlet Pressure – bar (psi)
(700) (1500) (2200) (2900) (4400) (5000) 0
Outlet Pressure – bar (psi) 0 50 100 150 200 250 300 350
Case Flow (700)
Versus(1500)
Outlet(2200) (2900)
Pressure Cutoff, (4400)
at (3600) (5000)
1800 r/min
Outlet
50°C (120° F) and 1.0 Pressure – bar
bar absolute (0 (psi)
psi gauge) Inlet
Input Torque and Power at 1000 r/min 12 (3.17)
50°C (120°F)Input
and Torque
1.0 bar and
absolute
Power(0 at
psi1000
gauge) Inlet
r/min Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
400 (3540) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
400 (3540) 1112 (3.17)
(2.91)
360 (3186)
Case Flow - l/min (USgpm)

360 (3186) Input Torque,


320 (2832) Full Stroke
Input Torque,
Input Torque – Nm (in.lb.)

320 (2832) Full Stroke 11 (2.91)


280 (2478) 10 (2.64)
Case Flow - l/min (USgpm)
Input Torque – Nm (in.lb.)

280 (2478)
240 (2124)
240 (2124)
200 (1770) 910 (2.64)
(2.38)
Input Power – kW (hp)

200 (1770)
160 (1416) 80 (107)
Input Power – kW (hp)

160 (1416) 80 (107)


120 (1062) 60 (80) 89 (2.38)
(2.11)
Input Power,
120 (1062) Full Stroke 60 (80)
80 (708) Input Power, 40 (54)
80 (708) Full Stroke 40 (54) 8 (2.11)
40 (354) 20 (27) 7 (1.85)
0 50 100 150 200 250 300 350
40 20 (27)
0 (354) 0 (700) (1500) (2200) (2900) (3600) (4400) (5000)
0 50 100 150 200 250 300 350
0 (700) (1500) (2200) (2900) (3600) (4400)(5000) 0 7 (1.85) Outlet Pressure - bar (psi)
0 50 100
Outlet(1500) 150– bar
Pressure 200(psi)250 300 350 0 50 100 150 200 250 300 350
(700) (2200) (2900) (3600) (4400)(5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Outlet Pressure - bar (psi)

48 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM074

Typical
Typical Noise
Noise Levels
Levels Delivery and Case Flow Versus Speed
Petroleum
Petroleum Oil (10W) at
Oil (10W) at 93°C
93°C (200°F),
(200°F), @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
1.0
1.0 bar
bar absolute
absolute (0
(0 psi
psi gauge)
gauge) Inlet
Inlet 180 (48)
(Sound
(Sound pressure
pressure data
data equivalent
equivalent to
to NFPA)
NFPA) 50 bar (700 psi),
160 (42)

Delivery – l/min (USgpm)


84

Case Flow – l/min (USgpm)


84 Delivery
140 (37)
80 120 (32)
80 2400
2400 r/min
r/min 280 bar (4000 psi),
Min. 100 (26)
Min. Flow
Flow Delivery
76
76 80 (21) 8 (2.1)
2400
2400 r/min
r/min
dBA

60 (16) 280 bar (4000 psi), Case flow 6 (1.6)


Level––dBA

Max. Flow
Max. Flow
72
72 40 (11) 4 (1.1)
20 (5) 50 bar (700 psi), Case flow
NoiseLevel

68 2 (0.5)
68
0 0
600
600 r/min
r/min 0 500 1000 1500 2000 2500
Noise

64 Min.
64 Min. Flow
Flow Speed – r/min
60 600
60 600 r/min
r/min
Max.
Max. Flow
Flow Input Torque Versus Speed
56
56 @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
400 (3540)
Input Torque – Nm (in.lb.)

52 320 bar (4600 psi)

Pressure – bar (psi)


52 350 (3097)
0
0 50
50 100
100 150
150 200
200 250
250 300
300 280 bar (4000 psi)
(700) (1500) (2200) (2900) (3600) (4400) 300 (2655)
(700) (1500) (2200) (2900) (3600) (4400) 250 bar (3600 psi)
Outlet
Outlet Pressure
Pressure –– bar
bar (psi)
(psi) 250 (2212)
200 bar (2900 psi)
200 (1770)
150 bar (2200 psi)
150 (1327)
100 bar (1500 psi)
Overall
Overall Efficiency
Efficiency Versus
Versus Speed
Speed 100 (885)
at 50 bar (700 psi)
at 93°C
93°C (200°F)
(200°F) and
and 1.0
1.0 bar
bar absolute
absolute (0
(0 psi
psi gauge)
gauge) Inlet
Inlet 50 (442)
95
95 17 bar (250 psi)
0
0 500 1000 1500 2000 2500
90 Speed – r/min
90 50
50 bar
bar
(700
(700 psi)
psi)
85 Input Power Versus Speed
Input Power @ Full Flow – kW (hp)

85 100
100 bar
bar 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
(1500
(1500 psi)
Efficiency––%%

psi) 100 (134)


150 320 (4600)
80
80 150 bar
bar 90 (121)
Pressure – bar (psi)
(2200
(2200 psi)
Efficiency

psi) 280 (4000)


80 (107)
200
200 bar
bar
75
75 (2900psi) 70 (94) 250 (3600)
(2900psi)
60 (80) 200 (2900)
250
250 bar
bar
70 (3600 50 (67)
70 (3600 psi)
psi) 150 (2200)
280 40 (54)
280 bar
bar
(4000
(4000 psi)
psi) 30 (40) 100 (1500)
65
65
320 20 (27) 50 (700)
320 bar
bar
(4600
(4600 psi)
psi) 10 (13)
60 17 (250)
600 500 1000 1500 2000 2500 0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed
Speed –
– r/min
r/min Speed – r/min

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 49
Performance

Mobile
PVM074

Input
Input Torque
Torque and
and Case
Case Flow
Flow Versus
Versus Speed
Speed
@
@ 93°C (200°F), load sense standby
93°C (200°F), load sense standby and
and
1.0
1.0 bar
bar absolute
absolute (0
(0 psi
psi gauge)
gauge) inlet
inlet
20
20 bar
bar (300
(300 psi)
psi) differential,
differential,
7
7 (62)
(62) Input
Input Torque
Torque

6
6 (53)
(53)

(in.lb.)
Nm(in.lb.)
5
5 (44)
(44)
Torque––Nm 11
11 bar
bar (160)
(160) differential
8.0
8.0 (2.11)

(USgpm)
differential (2.11)

l/min(USgpm)
4
4 (35) Input
(35) Input Torque
Torque
InputTorque

6.0
6.0 (1.58)
(1.58)
3
3 (27)
(27) 20
20 bar
bar (300
(300 psi)
psi) differential
differential

Flow––l/min
Case
Case Flow
Flow
Input

2 4.0
4.0 (1.06)
(1.06)
2 (18)
(18)

CaseFlow
1 2.0
2.0 (0.53)
1 (9)
(9) 11
(0.53)
11 bar
bar (160
(160 psi)
psi) differential

Case
differential
Case Flow
Case Flow
0
00 0
0
0 500
500 1000
1000 1500
1500 2000
2000 2500
2500
Speed – r/min
Speed – r/min

Input
Input Torque
Torque and
and Case
Case Flow
Flow Versus
Versus Speed
Speed
@
@ 93°C (200°F), cut-off and
93°C (200°F), cut-off and
1.0
1.0 bar
bar absolute
absolute (0
(0 psi
psi gauge)
gauge) inlet
inlet
160
160 (1416)
(1416)
280
280 bar
bar (4000
(4000 psi),
psi),
140 Input
Input Torque
140 (1239)
(1239) Torque

120
120 (1062)
(in.lb.)

(1062)
Nm(in.lb.)

100
100 (885)
(885)
Torque––Nm

(USgpm)
l/min(USgpm)

80
80 (708)
(708) 150
150 bar
bar (2200
(2200 psi),
InputTorque

psi),
Input Torque
Input Torque
60
60 (531) 30
(531) 30 (7.9)
Flow––l/min

(7.9)
Input

280
280 bar
bar (4000
(4000 psi),
psi), Case
Case Flow
Flow
40
40 (354) 20
(354) 20 (5.3)
(5.3)
CaseFlow

20
20 (177) 10
(177)
150 10 (2.6)
(2.6)
150 bar
bar (2200
(2200 psi),
psi), Case
Case Flow
Case

Flow
0
00 0
0
0 500 1000
1000 1500 2000
2000 2500
500 Speed 1500 2500
Speed –
– r/min
r/min

50 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM081

Typical Noise Levels at 1800 and 1200 r/min. with


Petroleum Oil (10W) at 50°C (120°F)
Typicaland 1.0 Levels
Noise bar absolute
at 1800(0and
psi 1200
gauge) Inletwith
r/min. Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
74 Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
1800 r/min
and 1.0 bar absolute (0 psi gauge) Inlet Delivery
100 and Efficiency at 1800 r/min, 50ϒC (120ϒF),
74 min. flow and 1.0 bar Efficiency
Volumetric absolute (0 psi gauge) Inlet
72
1800 r/min 100
90
1800 r/min min. flow Volumetric EfficiencyOverall Efficiency
72
70 max. flow 90
80
1800 r/min Overall Efficiency
– dBA– dBA

70
68 max. flow 80
70

– %– %
70
60 150 (40)
68 1200 r/min
LevelLevel

(USgpm)
66 max. flow Delivery (effective flow)

Efficiency
60
50 150 (33)
125 (40)
1200 r/min

(USgpm)
1200 r/min
NoiseNoise

Delivery (effective flow)

Efficiency
66
64 max. flow 50
40 125 (26)
100 (33)
min. flow

– l/min
1200 r/min 100(20)
(26)
64 40
30 75
62 min. flow

– l/min
30
20 75 (13)
50 (20)

Delivery
62
60
20
10 50 (7)
25 (13)

Delivery
60
58
50 100 150 200 250 10
0 025 (7)
0 0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600) (700) (1500) (2200) (2900) (3600)0
58 0
0 50 Outlet100
Pressure150
– bar (psi)
200 250 0 50 100
Outlet Pressure150 200
– bar (psi) 250
(700) (1500) (2200) (2900) (3600) (700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),


and 1.0 bar absolute (0 psi gauge) Inlet
Typical Noise Levels at 1500 and 1000 r/min. with Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
Petroleum Oil (10W) at 50°C (120°F) 350 (3097)
and 1.0 bar absolute (0 psi gauge) Inlet

kW (hp)
Typicaland 1.0 Levels
Noise bar absolute
at 1500(0and
psi 1000
gauge) Inletwith
r/min. 350 (3097)

– kW– (hp)
72 Petroleum Oil (10W) at 50°C (120°F) 300 (2655)
and 1.0 bar absolute (0 psi gauge) Inlet Input Torque,
Nm (in.lb.)

72
70 300 (2655) Full Stroke

Power
250 (2212) Input Torque,
– Nm– (in.lb.)

Full Stroke

Power
70 1500 r/min 250 (2212)
68 max. flow
InputInput
200 (1770)
– dBA– dBA

1500 r/min
Torque

68
66 max. flow 200 (1770)
1500 r/min 150 (1327) 75 (101)
Torque

Input Power,
LevelLevel

66 min. flow
64 150 (1327) Full Stroke 75 (101)
InputInput

1500 r/min 100 (885) 50 (67)


min. flow Input Power,
NoiseNoise

64
62 Full Stroke
100 (885) 50 (67)
1000 r/min 50 (442) Input Torque, 25 (34)
min. flow Cut-off
62
60 1000 r/min Input Torque, 25 (34)
1000 r/min 50 (442)
max. flow 0 Cut-off 0
min. flow
60 1000 r/min 0 50 100 150 200 250
58 0 (700) (1500) (2200) (2900) (3600)0
max. flow
0 50
Outlet 100
Pressure150
– bar 200
(psi) 250
58
56 (700) (1500) (2200) (2900) (3600)
0 50 100 150 200 250 Outlet Pressure – bar (psi)
56 (700) (1500) (2200) (2900) (3600)
0 50 Outlet100 Pressure150 200
– bar (psi) 250
Sound (700)
pressure(1500)
data (2200) (2900) (3600)
equivalent Outlet
to NFPA.Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 51
Performance

Industrial
PVM081

Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF), Deli


Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF), and
Delivery and1.0Efficiency
bar absolute (0 psi
at 1200 gauge)
r/min, 50ϒCInlet
(120ϒF), Deliv
and 1.0 bar absolute (0 psi gauge) Inlet

(USgpm)
100 and 1.0 bar absolute (0 psi gauge) Inlet
Delivery
100 and Efficiency at 1500 r/min, 50ϒC (120ϒF), 100

(USgpm)
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency 100 Volumetric Efficiency 100
100
90 90 Volumetric Efficiency 90
Overall Efficiency
Volumetric Efficiency Overall Efficiency 90 90

– l/min
90
80 80 Overall Efficiency 80

– l/min
Overall Efficiency
80 80
80
70 70 70

Delivery
– %– %

70 70

– %– %
70

Delivery
60 60 60
Efficiency

(USgpm)

Efficiency
60 60 60

– %– %
50 125 (33) 50 125 (33) 50

Efficiency
Efficiency

50
Delivery (effective flow) (USgpm) 50 125 (33)
125 (26)
(33) 50

Efficiency
40 100 40 100 (26)
Delivery (effective flow) 40

Efficiency
– l/min

40
30 100(20)
75 (26) 40 Delivery (effective flow) 100 (26) 40
30 75 (20) 30
Delivery (effective flow)
– l/min

30
20 75 (13)
50 (20) 30 75 (20) 30
20 50 (13)
Delivery

20
20
10 50 (7)
25 (13) 20 50 (13) 20
Delivery

10 25 (7) 10
10
0 25 (7)
0 10 25 (7) 10
0 50 100 150 200 250 0 0 0
0 (700) (1500) (2200) (2900) (3600)
0 0 50 100 150 200 250
0 50 100 150 200 250 0 0 0
Outlet Pressure – bar (psi) 0 (700)
50 (1500)
100 (2200)
150 (2900)
200 (3600)
250 0
(700) (1500) (2200) (2900) (3600)
Outlet
(700) Pressure
(1500) – bar (psi)
(2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),


and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF), Input Torque and Power at 1200 r/min, 50ϒC (120ϒF), In
and 1.0 bar absolute (0 psi gauge) Inlet
350 (3097) and 1.0
Input Torque barPower
and absolute (0 psi
at 1200 gauge)
r/min, 50ϒCInlet
(120ϒF), Inp
kW (hp)

350 (3097) and


350 (3097) 1.0 bar absolute (0 psi gauge) Inlet 35
– kW– (hp)

(hp)(hp)
300 (2655)
350 (3097) 350
(in.lb.)

300 (2655)

– kW
300 (2655) 30
Power

250 (2212)
(in.lb.)

(in.lb.)
(in.lb.)

– kW
Input Torque, 300 (2655) 300
Power
– Nm

Power

(in.lb.)
250 (2212)
(in.lb.)

Full Stroke 250 (2212) 25


Input Torque, Input Torque,
InputInput

200 (1770)
Power
– Nm

– Nm
250 (2212) 250
– Nm

Full Stroke Full Stroke


Input Torque,
Torque

200 (1770)
Input

200 (1770) 20

– Nm
– Nm

150 (1327) 75 (101) Full Stroke


Torque

Torque
Input
Torque

200 (1770) 200


150 (1327) 75 (101)
Torque
InputInput

150 (1327) 75 (101)


Torque

15
100 (885) 50 (67)
150 (1327) 75 (101) Input
150
Input

100 (885) 50 (67) 100 (885) 50 (67) 1


Input
Input

50 (442) 25 (34) Input Power,


Input Power, 100 (885) Full Stroke 50 (67) 10
50 (442) Full Stroke 25 (34) Input Power,
Input Power, 50 (442) Full Stroke 25 (34)
0 0
0 50 100 Full
150 Stroke
200 250 50 (442) 25 (34) 5
0 (700) (1500) (2200) (2900) (3600) 0 0 0
0 50 100 150 200 250
Outlet(1500)
(700) Pressure – bar
(2200) (psi) (3600)
(2900) 0 0 50
(700)
100 150 200 250 0
0 50 (1500)
100 (2200) 200 (3600)
150 (2900) 250
Outlet Pressure – bar (psi) Outlet Pressure – bar
(700) (1500) (2200) (2900)(psi) (3600)
Outlet Pressure – bar (psi)

52 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM081

ϒF), Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),


ϒF), andand
Delivery 1.0 bar absolute
Efficiency at (0 psir/min,
1000 gauge) Inlet
50ϒC (120ϒF), Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,

(USgpm)
(USgpm)

and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
100

(USgpm)
(USgpm)

Volumetric Efficiency
100 4.0 (1.06)
90 Volumetric EfficiencyOverall Efficiency

– l/min
– l/min

90 Overall Efficiency
80 3.5 (0.92)

Case Flow l/min - (USgpm)


– l/min
– l/min

80
70

Delivery
Delivery

3.0 (0.79)
70

Delivery
Delivery

60
2.5 (0.66)
60
– %– %

5 (33) 50 125 (33)


25 (33) 50 125 (33) 2.0 (0.53)
Efficiency

0 (26) 40 100 (26)


Efficiency

00 (26) 40 100 (26) 1.5 (0.4)


(20) 30 75 (20)
Delivery (effective flow)
5 (20) 30 75 (20)
(13) 20 Delivery (effective flow) 50 (13) 1.0 (0.26)
0 (13) 20 50 (13)
(7) 10 25 (7) 0.5 (0.13)
5 (7) 10 25 (7)
0 0 0
0 50 100 150 200 2500 0 50 100 150 200 250
0 (700) (1500)
0 50 100 (2200)150 (2900) 200 (3600)250 (700) (1500) (2200) (2900) (3600)
) Outlet(1500)
(700) Pressure(2200)
– bar (psi)
(2900) (3600) Outlet Pressure - bar (psi)
Outlet Pressure – bar (psi)

ϒF), Input Torque and Power at 1000 r/min, 50ϒC (120ϒF), Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
0ϒF), Input and 1.0 and
Torque bar absolute
Power at (0 psir/min,
1000 gauge) Inlet
50ϒ C (120ϒF), 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
and
350 (3097) 1.0 bar absolute (0 psi gauge) Inlet
21 (5.55)
(hp)(hp)
(hp)(hp)

350 (3097)
20 (5.28)
– kW
– kW

300 (2655)
(in.lb.)

– kW
– kW

300 (2655) 19 (5.02)


Case Flow l/min - (USgpm)
Power
Power

(in.lb.)

250 (2212) 18 (4.76)


Power
Power

Input Torque,
– Nm

250 (2212)
Full Stroke
Input Torque, 17 (4.49)
Input
Input

200 (1770)
– Nm

Full Stroke
Input
Torque
Input

200 (1770) 16 (4.23)


Torque

(101) 150 (1327) 75 (101) 15 (3.96)


(101) 150 (1327) 75 (101)
Input

(67) 100 (885) 50 (67) 14 (3.70)


Input

(67) 100 (885) Input Power, 50 (67) 13 (3.43)


(34) 50 (442) Full Stroke
Input Power, 25 (34)
Full Stroke 12 (3.17)
(34) 50 (442) 25 (34)
0 0 11 (2.91)
0 50 100 150 200 250 0
0 0
0 (700) 100 (2200)
50 (1500) 200 (3600)
150 (2900) 250 0 50 100 150 200 250
Outlet
(700) Pressure – bar(2900)
(1500) (2200) (psi) (3600) (700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi) Outlet Pressure - bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 53
Performance
Typical
TypicalNoise
NoiseLevels
Levelsat
at2400
2400&&600
600r/min
r/min
with
withPetroleum
PetroleumOil
Oil(10W)
(10W)atat93°C
93°C(200°F)
(200°F)
Mobile and
and1.0
1.0bar
barabsolute
absolute(0
(0psi
psigauge)
gauge)Inlet
Inlet
PVM081 82
82
2400
2400r/min
r/min
max.
max.flow
flow
78
78
2400
2400r/min
r/min
min.
min.flow
flow
– dBA
dBA
74
74 Typical Noise Levels at 2400 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
Level –

and 1.0 bar absolute (0 psi gauge) Inlet


Noise Level

70
70
82
2400 r/min
max. flow
Noise

66
66
600
600r/min
r/min 78
max.
max.flow
flow 2400 r/min
62
62 600
600r/min
r/min min. flow
74min.
min.flow
flow

Noise Level – dBA


58
58
70
54
54
00 50
50 100
100 150
150 200
200 250
250
(700)
(700) (1500)
(1500) (2200)
(2200) (2900)
(2900)66 (3600)
(3600)
Outlet
OutletPressure
Pressure––bar
bar(psi)
(psi) 600 r/min
Sound
Soundpressure
pressuredata
data max. flow
equivalent
equivalentto
toNFPA.
NFPA. 62 600 r/min
min. flow
58

54
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.

Overall
OverallEfficiency
Efficiencyversus
versusSpeed
Speed Delivery
Deliveryand
andCase
CaseFlow
Flowversus
versusSpeed
Speed
at
at93°C
93°C(200°F)
(200°F)and
and1.0
1.0bar
barabsolute
absolute at
at93°C
93°C(200°F),
(200°F),Full
FullFlow
Flow1.0
1.0bar
barabsolute
absolute
(0
(0psi
psigauge)
gauge)inlet
inlet (0
(0psi
psigauge)
gauge)Inlet
Inlet

100
100 100
100bar
bar 200
200(53)
(53)
150
150bar
bar (1450
(1450psi)
psi) 50
50bar
bar(725
(725psi)
psi)
95
95 (2200
(2200psi)
psi) 180
180(48)
(48)
160
160(42)
(42)
90
90
Overall Efficiency
140 (37) versus Speed
140(37) 50
50bar
bar(725
(725 Delivery and Cas
l/min (USgpm)
(USgpm)

85
85
Efficiency (%)
(%)

psi)
at 93°C (200°F) and 1.0 bar absolutepsi)Delivery
Delivery at 93°C (200°F), Ful
(0120
120(32)
(32) 210
210bar
bar(3000
(3000 Case
CaseFlow
Flow (0 psi g
Overall Efficiency

80
80 psi gauge) inlet
230
230bar
bar(3300
(3300psi)
psi) psi)
psi)Delivery
Delivery l/min
l/min
75
75 100100
100
bar(26)
(26) 200 (53) (USgpm)
(USgpm)
– l/min

100
200
200bar
bar 150 bar (1450 psi) 50 bar (725 psi)
70
70 95 (2200 psi) 80
80(21)
(21) 210
210bar
bar(3000
(3000psi)
psi)Case
Case180 (48)88 (2.11)
Flow
Flow (2.11)
Overall

Delivery –

(2900
(2900psi)
psi)
65
65
Delivery

60
60(16)
(16) 160 (42)66 (1.59)
(1.59)
90
60
60
40
40(11)
(11) 140 (37)44 (1.06)
(1.06) 50 bar
Delivery – l/min (USgpm)

85
Overall Efficiency (%)

55
55 psi) De
20
20 (5)
(5) 50
50bar
bar(725
(725psi)
psi)Case
Case120
Flow
Flow 22 (0.53)
(0.53)
80 (32)
50
50 230 bar (3300 psi) 00
00 75 100 (26)
500
500 1000
1000 1500
1500 2000
2000 2500 3000
2500 3000 00 500
500 1000
1000 1500
1500 2000 2000 2500
2500 3000
3000
70 200 bar 80 (21)
Speed
Speed––r/min
r/min Speed
Speed(r/min)
(r/min) 210
(2900 psi)
65 60 (16)
60
40 (11)
55 50 ba
20 (5)
54 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
50
0 500 1000 1500 2000 2500 3000
Performance

Mobile
PVM081

InputTorque
Input Torqueversus
versusSpeed
Speedatat93°C
93°C(200°F),
(200°F), InputPower
Input Powerversus
versusSpeed
Speedatat93°C
93°C(200°F),
(200°F),
FullFlow
Full Flowand
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet FullFlow
Full Flowand
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet

350(2655)
350 (2655)
Input
InputTorque
Torqueversus
versusSpeed
Speedatat93°C
93°C(200°F),
(200°F), 100(134) Input
(134)InputPower
Powerversus
versusSpeed
Speedatat93°C
93°C(200°F),
(200°F),
100
Full
FullFlow
Flowand
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet Full
FullFlow
Flowand
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet
300(2655)
300 (2655) 230 bar (3300psi)
psi) 9090(121)
(121)
350
350(2655)
(2655) 230 bar (3300
100
100(134)
(134)
8080(107)
(107)
– Nm (in.lb.)

210bar
bar(3000
(3000psi)
psi)
– Nm (in.lb.)

250 (2212)
250 210 230bar
230 bar(3300
(3300psi)
psi)
300(2212)

– kW (hp)
– kW (hp)
300 (2655)
(2655) 230
230bar
bar(3300
(3300psi)
psi) 9090(121)
(121)
7070(94)
(94)
200bar
bar(2900
(2900psi)
psi)
200
808060
(107)
(107)
Nm (in.lb.)
(in.lb.)

200(1770)
200
250
250 (1770)
(2212)
(2212) 210
210bar
bar
150bar (3000
(3000
bar(2200 psi)
psi)
(2200psi)
psi) (80)
60 (80) 230
230bar
bar(3300
(3300psi)
psi)
150

kW (hp)
(hp)
7070 (94)
(94) 150 bar (2200 psi)
5050(67)
(67) 150
200bar
bar(2200
(2900psi)

Input–Power
Input –Power
–Torque

200 bar (2900 psi)


psi)
Input Torque

kW
Nm

150 (1327)
150
200(1327)
200 (1770)
(1770) 6060(80)
(80)
150
150bar
bar(1500
100bar
100 (2200
(2200psi)
psi)
(1500psi) 4040(54)
(54)
100 bar(1500
(1500 psi)
Input –

100
150bar
150 bar (2200psi)
bar(2200 psi)
psi)
5050(67)
(67)

Input Power
Power
Input Torque
Torque

100
100
150
150 (885)
(885)
(1327)
(1327) 3030(40)
(40)
100 bar
100bar (1500
bar(725
(1500psi)
psi) 4040(54)
(54)
5050bar psi)
(725 psi) 2020(27)
(27) 100
50100
50bar bar
bar (1500
(1500
(725
(725 psi)
psi)
psi)
psi)

Input
50 (442)
Input

50
100(442)
100 (885)
(885) 3030(40)
(40)
1717bar
bar(250
(250psi)
psi) 1010(13)
(13)
1717bar
bar(250
(250psi)
psi)
00 5050bar
bar(725
(725psi)
psi) 2020(27)
(27) 5050bar
bar (725
(725 psi)
psi)
50
50(442)
(442) 0 500 1000
1000 1500
1500 2000
2000 2500 3000
2500 3000 00
0 500 10 0 500 1000 1500 2000
(13)0 500 1000 1500 2000 2500
10(13) 2500 3000
3000
1717bar
bar(250
(250psi)
psi) 1717bar
bar(250
(250psi)
psi)
00 Speed(r/min)
Speed (r/min) Speed(r/min)
Speed (r/min)
00
00 500
500 1000
1000 1500
1500 2000
2000 2500 3000
2500 3000 00 500
500 1000
1000 1500
1500 2000
20002500
2500 30003000
Speed
Speed(r/min)
(r/min) Speed
Speed(r/min)
(r/min)

InputTorque
Input Torqueand andCaseCaseFlowFlowversus
versusSpeedSpeedatat93°C93°C InputTorque
Input TorqueandandCaseCaseFlow
Flowversus
versusSpeed
Speedatat93°C
93°C
(200°F), Load Sense Standby and
(200°F), Load Sense Standby and 1.0 bar absolute 1.0 bar absolute (200°F),Pressure
(200°F), PressureLimit
LimitCut-off
Cut-offand
and1.01.0bar
barabsolute
absolute
(0(0psi
psigauge)
gauge)InletInlet (0(0psi
psigauge)
gauge)Inlet
Inlet
Input
InputTorque
Torqueand andCaseCaseFlowFlowversus
versusSpeed
Speedatat93°C 93°C Input
InputTorque
TorqueandandCaseCaseFlow
Flowversus
versusSpeed
Speedatat93°C
93°C

– l/min (USgpm)
– l/min (USgpm)
9 (80)
(200°F),
9 (80)(200°F),Load
Load Sense
Sense Standby
Standby and
and 1.0
1.0bar
bar absolute
absolute 8080 (708) Pressure
(708)
(200°F),
(200°F), PressureLimit
LimitCut-off
Cut-offandand1.01.0bar
barabsolute
absolute
2020barbar(0(0(300
(300psi
psipsi)
gauge)
gauge)Inlet
psi) Inlet (0(0psi
psigauge)
gauge)Inlet
Inlet
8 8(71)
(71) diff.Input
InputTorque
Torque 7070(619)
(619)

Flow (USgpm)
Flow (USgpm)
diff. 8080(708)
(708) 210bar
bar(3000
(3000psi)
psi)Input
InputTorque
Torque
– Nm (in.lb.)

99(80)
(80) 210
– Nm (in.lb.)

150bar
150 bar
– Nm (in.lb.)
– Nm (in.lb.)

7 7(62)
(62) 20
20barbar(300(300psi)
psi) 6060(531)
(531) (2200
(2200psi)
psi)
88(71)
(71) diff.
diff.Input
InputTorque
Torque 1111bar
bar(160
(160psi)
psi)diff.
diff. 7070(619)
(619) Input
Case Input 210
210barbar(3000
(3000psi)
psi)Input
InputTorque
Torque
Case
Nm (in.lb.)
(in.lb.)

6 6(53)
(53) InputTorque
Torque
Input
Flowl/min
l/min 5050(442) Torque
(442) Torque
150
150bar
bar – l/min
l/min
Nm (in.lb.)
(in.lb.)

77(62)
(62) Flow 6060(531)
(531) (2200
(USgpm) (2200psi)
psi)
5 5(44)
(44) (USgpm)
–Torque

Case
Input Torque

1111bar
bar(160
(160psi)
psi)diff.
diff.
Case

(354) Input
Input

4040(354)
Nm
–Torque

Case
Case
Input Torque

210bar
bar
Case Flow
Flow

66(53)
(53) Input
InputTorque
Torque 50 (442) 210
50(442) Torque
Torque
Nm

4 4(35)
(35) 10.0
Flow
10.0 (2.64)
Flow(2.64)
l/min
l/min (3000psi)
(3000 psi)
Input –

55(44)
(44) (USgpm)
(USgpm) 3030(265)
(265) Case 8.0(2.11)
8.0 (2.11)
Input –

Case
Input Torque
Torque

Case

2020barbar(300
(300psi)
psi) 8.0(2.11)
8.0 (2.11) 4040(354)
(354) Flow
3 3(27)
(27)
Input Torque
Torque

diff.Case
diff. CaseFlowFlow 210
210bar
Flow bar 6.0(1.59)
(1.59)
44(35)
(35) 10.0
10.0 (2.64)
(2.64) 2020(177)
(177) (3000
(3000psi)
psi) 6.0
2 2(18)
(18) 6.0(1.59)
6.0 (1.59) 3030(265)
(265) Case 8.0
8.0(2.11)
(2.11)
11 bar (160 psi)
11 bar (160 psi) diff.diff. Case 4.0(1.06)
(1.06)
Input

2020barbar(300
(300psi)
psi) 8.0
8.0(2.11)
(2.11) 150bar
bar 4.0
CaseFlow
Flow (88) 150
Input

33(27)
(27) Case 4.0(1.06)
(1.06) 1010(88) Flow
Flow
1 (9) diff.
diff.Case
Case Flow
Flow 4.0 (2200 psi) 6.0
6.0(1.59)
(1.59)
1 (9) 20 (177) (2200 psi)
20(177) 2.0(.53)
2.0 (.53)
22(18)
(18) 6.0
6.0(1.59)
(1.59) CaseFlow
Case Flow
1111bar
bar(160
(160psi)
psi)diff. 2.0(0.53)
diff.2.0 (0.53) 4.0
4.0(1.06)
(1.06)
Case
Case Flow
Flow 150
150bar
bar 1000
0 0 500 1000
500 1000 1500 1500 2000 2000 2500 2500 300030004.0
4.0 (1.06)
(1.06) 10
10(88)0 0(2200
(88) 500
500
(2200
1500 2000 2500 3000
psi)1000 1500 2000 2500
psi) 3000
11(9)(9) 2.0
2.0(.53)
(.53)
Speed(r/min)
Speed (r/min) Case Flow Speed
CaseFlow Speed(r/min)
(r/min)
2.0
2.0(0.53)
(0.53)
00 500
500 1000 1000 1500 1500 2000 2000 25002500 3000 3000 00 500
500 1000
1000 1500
1500 2000
2000 2500
2500 3000
3000
Speed
Speed(r/min)
(r/min) Speed
Speed(r/min)
(r/min)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 55
Performance

Industrial
PVM098

Typical Noise Levels at 1800 and 1200 r/min Delivery and Efficiency at 1800 r/min
with Petroleum Oil (10W) at 50°C (120°F) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet 100
78
1800 r/min 90 Volumetric Efficiency
Delivery and Efficiency at 1800 r/min
76 Max. Flow 50°C (120°F) andOverall
1.0 barEfficiency
absolute (0 psi gauge) Inlet
80 100
74 1800 r/min
Min. Flow
70 90 Volumetric Efficiency
72

Efficiency - %
Overall Efficiency
1200 r/min 60 80
Noise Level – dBA

70 Max. Flow
68 50 70

Delivery -l/min (USgpm)


Efficiency - %
66 40 60 Delivery (effective flow) 200 (53)

64 30 50 150 (40)

Delivery -l/min (USgpm)


62 20 40 Delivery (effective flow)100 (26)200 (53)
60 30 50 (13) 150 (40)
10
58 1200 r/min
Min. Flow 20 0 100 (26)
0
56 50 100 150 200 250 300 350 0
0 50 100 150 200 250 300 (700) (1500) (2200) (2900) (3600) (4400)(5000)
10 50 (13)
(700) (1500) (2200) (2900) (3600) (4400) Outlet Pressure - bar (psi)
Outlet Pressure – bar (psi) 0 0
Sound pressure data 0 50 100 150 200 250 300 350
equivalent to NFPA) Input Torque and Power at 1800 r/min
(700) (1500) (2200) (2900) (3600) (4400)(5000)
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Outlet Pressure - bar (psi)
550 (4867)

Typical Noise Levels at 1500 and 1000 r/min 500 (4425) Input Torque and Power at 1800 r/min
with Petroleum Oil (10W) at 50°C (120°F) 50°C (120°F) and 1.0 barTorque,
Input absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet 450 (3982)
550 (4867) Full Stroke
72
Input Torque - Nm (in.lb.)

400 (3540)
500 (4425)
1500 r/min Input Torque,
70 Max. Flow 350 (3097)
450 (3982) Full Stroke
68 300 (2655)
Input Torque - Nm (in.lb.)

400 (3540)
1500 r/min 250 (2212) Input Power,
66
Input Power - kW (hp)
Min. Flow 350 (3097) Full Stroke
Noise Level – dBA

64 1000 r/min 200 (1770)


300 (2655) 100 (134)
Max. Flow
62 150 (1327)
250 (2212) 75 (101)
Input Power,
Input Power - kW (hp)

Full Stroke
60 100 (885)
200 (1770) 50 (67) 100 (134)
50 (442)
150 (1327) 25 (34) 75 (101)
Input Torque,
58 Cut-off
0 0
100
0 (885)50 100 150 200 250 300 350 50 (67)
56
(700) (1500) (2200) (2900) (3600) (4400) (5000)
50 (442) Outlet Pressure - bar (psi) Input Torque, 25 (34)
54 1000 r/min Cut-off
Min. Flow 0 0
52 0 50 100 150 200 250 300 350
0 50 100 150 200 250 300 (700) (1500) (2200) (2900) (3600) (4400) (5000)
(700) (1500) (2200) (2900) (3600) (4400) Outlet Pressure - bar (psi)
Outlet Pressure – bar (psi)

56 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM098

Delivery and Efficiency at 1500 r/min Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 100
Volumetric Efficiency Volumetric Efficiency
90 Delivery and Efficiency at 1500 r/min 90 Delivery and Efficiency at 1200 r/min
50°C (120°F) andOverall
1.0 barEfficiency
absolute (0 psi gauge) Inlet 50°C (120°F)Overall
and 1.0Efficiency
bar absolute (0 psi gauge) Inlet
80 100 80 100
Volumetric Efficiency Volumetric Efficiency
70 90 70 90
Overall Efficiency Overall Efficiency
Efficiency – %

Efficiency – %
60 80 60 80
70

Delivery – l/min (USgpm)


50

Delivery – l/min (USgpm)


70 50

Efficiency – %
Efficiency – %

40 60 200 (53) 40 60 200 (53)


Delivery (effective flow)

Delivery – l/min (USgpm)


30 150 (40) 50
50 Delivery – l/min (USgpm) 30 Delivery (effective flow) 150 (40)

20 40 100 200
(26) (53) 20 40 100 200
(26)(53)
Delivery (effective flow)
10 30 50 (13)
150 (40) 10 30 150 (40)
Delivery (effective flow) 50 (13)
0 20 0 100 (26) 0 20 0 100 (26)
0 50 100 150 200 250 300 350 50 100 150 200 250 300 3500
10(700) (1500) (2200) (2900) (3600) (4400) (5000) 50 (13) 10(700) (1500) (2200) (2900) (3600) (4400) (5000) 50 (13)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)
0 0 0 0
0Input 50 0 50 100 150 200 250 300 350
Torque100 150 200
and Power at 1500250
r/min300 350 Input(700)
Torque and(2200)
(1500) Power(2900)
at 1200 r/min
(3600) (4400) (5000)
(700)
50°C (120°F) and(1500)
1.0 bar(2200) (2900)
absolute (3600)
(0 psi (4400)
gauge) (5000)
Inlet
Outlet Pressure – bar (psi) 50°C (120°F) and 1.0 barPressure
Outlet absolute–(0bar
psi(psi)
gauge) Inlet
550 (4867) 550 (4867)
500 (4425) Input Torque and Power at 1500 r/min 500 (4425) Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
450 (3982)
550 (4867) 450 (3982) Input Torque,
Input Torque, 550 (4867) Full Stroke
Input Torque – Nm (in.lb.)

Input Torque – Nm (in.lb.)

400 (3540)
500 (4425) Full Stroke 400 (3540)
500 (4425)
350 (3097)
450 (3982) 350 (3097) Input Torque,
450 (3982) Full Stroke
Input Torque,
Input Torque – Nm (in.lb.)

300 (2655)
Input Torque – Nm (in.lb.)

400 (3540) Full Stroke 300 (2655)


400 (3540)
250 (2212)
Input Power – kW (hp)

Input Power – kW (hp)


350 (3097) 250 (2212)
350 (3097)
200 (1770) Input Power, 100 (134) 200 (1770) 100 (134)
300 (2655) 300 (2655)
Full Stroke Input Power,
150 (1327) 75 (101) 150 (1327) Full Stroke 75 (101)
250 (2212)
Input Power – kW (hp)
Input Power – kW (hp)

250 (2212)
100 (885)
200 (1770) 50 (67)
100 (134) 100 (885) 50 (67)
100 (134)
Input Power, 200 (1770)
Full Stroke 25 (34) Input Power,
50 (442)
150 (1327) 75 (101) 50 (442)
150 (1327) Full Stroke 25 (34)
75 (101)
0
1000(885) 50 100 150 200 250 300 3500 50 (67) 0 (885)
100 0 50 (67)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000) 25 (34)
50 (442) Outlet Pressure – bar (psi) 25 (34) 50 (442) Outlet Pressure – bar (psi)
0 0 0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 57
Performance

Industrial
PVM098

Delivery and Efficiency at 1000 r/min Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
100 5,5 (1.45)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min
90 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 5,0Case
(1.32)Flow Versus Outlet Pressure at Full Flow, 1800 r/min
Overall Efficiency 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
100 4,5 (1.19)
80 5,5 (1.45)
Volumetric Efficiency
90 4,0 (1.06)

- l/min (USgpm)
70 Overall Efficiency 5,0 (1.32)
3,5 (0.92)
Efficiency – %

80
60 4,5 (1.19)
70 3,0 (0.79)
4,0 (1.06)

(USgpm)
Delivery – l/min (USgpm)
50
Efficiency – %

2,5 (0.66)
60 3,5 (0.92)
40 200 (53)

Flow
Delivery – l/min (USgpm) 2,0 (0.53)
50 3,0 (0.79)
- l/min
30 150 (40)
1,5 (0.40)
40 200 (53) Delivery (effective flow) Case FlowCase 2,5 (0.66)
20 100 (26) 1,0 (0.26)
150 (40) 2,0 (0.53)
30
10 Delivery (effective flow)50 (13) 0,5 (0.13)
1,5 (0.40)
0 20 0 100 (26) 0
0 50 100 150 200 250 300 350 1,0 (0.26)0 50 100 150 200 250 300 350
10 (700) (1500) (2200) (2900) (3600) (4400) (5000) 50 (13) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) 0,5 (0.13) Outlet Pressure - bar (psi)
0 0
0 50 100 150 200 250 300 350 0
(700) (1500) (2200) (2900) (3600) (4400) (5000) 0 Flow
Case 50 Versus
100 Outlet
150 Pressure
200 250 at Cutoff,
3001800
350r/min
Input Torque andPressure
Outlet Power at–1000 r/min
bar (psi) 50°C(700)
(120°(1500)
F) and (2200)
1.0 bar(2900) (3600)
absolute (4400)
(0 psi (5000)
gauge) Inlet
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet Outlet Pressure - bar (psi)
25 (6.60)
550 (4867)
Input Torque and Power at 1000 r/min Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
500 (4425) 24 (6.34)
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
550 (4867)
450 (3982) Input Torque, 25 (6.60)
- l/min (USgpm)
Input Torque – Nm (in.lb.)

Full Stroke 23 (6.08)


500 (4425)
400 (3540)
24 (6.34)
450 (3982)
350 (3097) Input Torque, 22 (5.81)
Input Torque – Nm (in.lb.)

Full Stroke
(USgpm)

400 (3540)
300 (2655) 23 (6.08)
21 (5.55)
350 (3097)
Input Power – kW (hp)

250 (2212)
Flow

22 (5.81)
20 (5.28)
- l/min

300 (2655)
200 (1770) 100 (134)
Case FlowCase

21 (5.55)
Input Power – kW (hp)

250 (2212)
150 (1327) 75 (101) 19 (5.02)
Input Power,
100200
(885)(1770) Full Stroke 100 (134)
50 (67) 20 (5.28)
18 (4.76)
50150
(442)(1327) 75 (101)
25 (34)
Input Power, 19 (5.02)
Full Stroke 0 50 (67) 17 (4.49)
1000(885) 0 50 100 150 200 250 300 350
0 50 100 150 200 250 300 350 (700) (1500) (2200) (2900) (3600) (4400)(5000)
50 (442) (700) (1500) (2200) (2900) (3600) (4400) (5000) 25 (34) 18 (4.76)
Outlet Pressure - bar (psi) Outlet Pressure - bar (psi)
0 0 17 (4.49)
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400)(5000)
Outlet Pressure - bar (psi)
Outlet Pressure - bar (psi)

58 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM098

Typical Noise Levels at 2000 and 600 r/min


Delivery and Case Flow Versus Speed
with petroleum oil (10 W) @ 93°C (200°F)
Typical Noise Levels at 2000 and 600 r/min @ 93°C
Delivery and Case(200°F),
Flow Versus full flow and
Speed
and 1.0 bar absolute (0 psi gauge) inlet
86 with petroleum oil (10 W) @ 93°C (200°F) @ 1.0 bar
93°C absolute
(200°F), full(0flow
psi)andgauge Inlet
and 1.0 bar absolute (0 psi gauge) inlet 220 (58) 1.0 bar absolute (0 psi) gauge Inlet
86
84 2000 r/min 220 (58)
Min. flow 200 (53) 50 bar (700 psi),
84
82 2000 r/min 200 (53) 50 barDelivery
(700 psi),
Min. flow 180 (48) Delivery
82
80 2000 r/min
Max. flow 180 (48)

Delivery – l/min (USgpm)


160 (42)
– dBA

2000 r/min

Delivery – l/min (USgpm)


80
78 Max. flow 160 (42)
140 (37) 280 bar (4000 psi),
– dBA

78 280 Delivery
bar (4000 psi),
76 140 (37)
Level

120 (32) Delivery

Case Flow – l/min (USgpm)


76
74 120 (32)
Level

100 (26)
Noise

600 r/min 280 bar (4000 psi),


74
72 Max. flow 100 (26)
80 (21) Case flowpsi), 8 (2.1)
Noise

600 r/min 280 bar (4000


70
72 600 r/min Max. flow 80 (21) Case flow 8 (2.1)
Min. flow 60 (16) 6 (1.6)
70
68 600 r/min 60 (16) 6 (1.6)
Min. flow 40 (11) 50 bar (700 psi), 4 (1.1)
66
68 40 (11) 50 barCase (700flow
psi), 4 (1.1)
20 (5) 2 (0.5)
Case flow
66
64 20 (5) 2 (0.5)
0 50 100 150 200 250 300 0 0
64 (700) (1500) (2200) (2900) (3600) (4400) 0 0 500 1000 1500 2000 0 2500
0 50 Outlet
100 Pressure
150 – bar
200(psi) 250 300 0 500 1000 Speed1500 – r/min2000 2500
(700) (1500) (2200) (2900) (3600) (4400) Speed – r/min
Sound pressure
OutlettoPressure
data equivalent NFP – bar (psi)
Sound pressure
data equivalent to NFP

Overall Efficiency Versus Speed Input Torque Versus Speed


@ 93°C (200°F) and 1.0 bar absolute Input@Torque
93°C (200°F),
Versus Speedfull flow and
Overall Efficiency Versus Speed 1.0 bar
@ 93°C absolute
(200°F), full(0flow
psi and
gauge) inlet
(0 psi gauge) inlet
@ 93°C (200°F) and 1.0 bar absolute 600 (5310) 1.0 bar absolute (0 psi gauge) inlet
95
(0 psi gauge) inlet 600 (5310)
95 540 (4779)
540 (4779) 320 bar (4600 psi)
480 (4248) 320 bar (4600 psi)
Input Torque – Nm (in.lb.)

90 280 bar (4000 psi)


480 (4248)
Input Torque – Nm (in.lb.)

420 (3717) 280 bar (4000 psi)


(%) (%)

90 250 bar (3600 psi)


420 (3717)
250 bar (3600 psi)
Efficiency

360 (3186)
85 100 bar (1500 psi)
150 bar (2200 psi) 360 (3186) 200 bar (2900 psi)
Efficiency

85 100 bar (1500 psi) 300 (2655) 200 bar (2900 psi)
150 bar (2200 psi) 50 bar (700 psi) 300 (2655)
200 bar (2900 psi) 240 (2124) 150 bar (2200 psi)
Overall

80 50 bar (700 psi) 240 (2124) 150 bar (2200 psi)


200 bar (2900 psi)
Overall

80 180 (1593) 100 bar (1500 psi)


180 (1593) 100 bar (1500 psi)
250 bar (3600 psi) 120 (1062)
75 50 bar (700 psi)
280bar
bar(3600
(4000psi)
psi) 120 (1062)
250 60 (531) 50 bar (700 psi)
75 17 bar (250 psi)
280
320bar
bar(4000
(4600psi)
psi) 60 (531)
0 17 bar (250 psi)
70
500 psi)
0320 bar (4600 1000 1500 2000 2500 0 500 1000 1500 2000 2500 3000
70 Speed – r/min 500 1000 1500 Speed
2000
– r/min2500 3000
0 500 1000 1500 2000 2500 Speed – r/min
Speed – r/min

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 59
Performance

Mobile
PVM098

Input Power Versus Speed


Input Power
@93°C (200°F),Versus
full flow Speed
and Input Torque and Case Flow Versus Speed
@93°C (200°F), full flow
1.0 bar absolute (0 psi gauge) and
inlet @ 93°C (200°F), cut-off and
130 (174) 1.0 bar absolute (0 psi gauge) inlet 1.0 bar absolute (0 psi gauge) inlet
130 (174) 240 (2124)
120 (161) 320 bar (4600 psi)
120 (161) 320 bar (4600 psi) 220 (1947) 280 bar (4000 psi)
110 (148) Input Torque
110 (148) 200 (1770)

Input Torque – Nm (lb.in.)


100 (134) 280 bar (4000 psi)
100 (134) 280 bar (4000 psi) 180 (1593)
250 bar (3600 psi)
(hp)

Case Flow – l/min (USgpm)


90 (121) 250 bar (3600 psi)
(hp)

90 (121) 160 (1416)


80 (107)
– KW

80 (107) 200 bar (2900 psi) 140 (1239)


– KW

70 (94) 200 bar (2900 psi) 120 (1062)


70 (94) 280 bar (4000 psi) 30 (7.9)
Power

60 (80) 100 (885) Case Flow


Power

60 (80) 150 bar (2200 psi) 25 (6.6)


50 (67) 150 bar (2200 psi) 80 (708) 20 (5.3)
50 (67)
Input

40 (54) 60 (531) 150 bar (2200 psi) 150 bar (2200 psi), Case Flow 15 (4.0)
Input

100 bar (1500 psi)


40 (54) 100 bar (1500 psi)
30 (40) 40 (354) Input Torque 10 (2.6)
30 (40) 50 bar (700 psi)
20 (27) 20 (177) 5 (1.3)
20 (27) 50 bar (700 psi) 0 500 1000 1500 2000 2500
10 (13) 17 bar (250 psi) Speed – r/min
10 (13) 17 bar (250 psi)
0
500
0 1000 1500 2000 2500 3000
500 1000 1500 2000 2500 3000 Case Flow at 2200 r/min, Full Flow
Speed – r/min
Speed – r/min 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
16 (4.2)
Case Flow – l/min (USgpm)

14 (3.7)
12 (3.2)
10 (2.6)
Input Torque and Case Flow Versus Speed
Input 8 (2.1)
@ Torque and Case
93°C (200°F), loadFlow
senseVersus
standbySpeed
@1.0
and 93°C
bar(200°F),
absoluteload sense
(0 psi standby
gauge) inlet 6 (1.6)
11 (77) and 1.0 bar absolute (0 psi gauge) inlet 4 (1.0)
11 (77) 2 (0.5)
10 (88) 20 bar (300) differential
10 (88) 20 bar
Input (300) differential
Torque 0
Input Torque 0 50 100 150 200 250 300 350
(in.lb.)

9 (80)
(700) (1500) (2200) (2900) (3600) (4400) (5000)
(in.lb.)

9 (80)
8 (71) Outlet Pressure – bar (psi)
– Nm

8 (71) 9.0 (2.38)


11 bar (160) differential
– Nm

7 (62) 11 bar
Input (160) differential
Torque 9.0 (2.38) Case Flow at 2200 r/min, Minimum Flow
Case Flow – l/min (USgpm)

7 (62) 8.5 (2.25)


Torque

Input Torque 935C (2005F), 1.0 bar absolute (0 psi gauge) Inlet
(USgpm)

6 (53) 8.5 (2.25)


Torque

(USgpm)

32 (8.4)
6 (53) 8.0 (2.11)
5 (44) 20 bar (300) differential 8.0 (2.11) 28 (7.4)
Input

5 (44) 20 bar
Case (300) differential
Flow 7.5 (1.98)
Input

24 (6.3)
(l/min

4 (35) Case Flow 7.5 (1.98)


(l/min

4 (35) 7.0 (1.85) 20 (5.3)


7.0 (1.85)
Flow

3 (27) 6.5 (1.72) 16 (4.2)


Flow

3 (27) 11 bar (160) differential 6.5 (1.72)


2 (18) Case
11 barFlow 12 (3.2)
Case

(160) differential 6.0 (1.59) 0


2 (18) Case Flow 50 100 150 200 250 300 350
Case

6.0 (1.59) (700) (1500) (2200) (2900) (3600) (4400) (5000)


1 (9) 5.5 (1.45)
1 (9)0 500 1000 1500 2000 25005.5 (1.45) Outlet Pressure – bar (psi)
0 500 1000 – r/min
Speed 1500 2000 2500
Speed – r/min

60 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM106

Typical Noise Levels at 1800 and 1200 r/min.


Typical Noise Levels at 1800 and 1200 r/min. Delivery
Deliveryand
andEfficiency
Efficiencyatat1800
1800r/min,
r/min,50ϒCC(120ϒ
50ϒ F),
(120ϒF),
with Petroleum Oil (10W) at 50°C (120°F)
with Petroleum Oil (10W) at 50°C (120°F) and
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet
and 1.0 bar absolute (0 psi gauge) Inlet

(USgpm)
l/min (USgpm)
and 1.0 bar absolute (0 psi gauge) Inlet
80
80 100
100
Volumetric
VolumetricEfficiency
Efficiency
78 1800 r/min
78 1800 flow
max. r/min 90
90
max. flow Overall
OverallEfficiency
Efficiency

Delivery –– l/min
76 80
80
76
70
dBA

70

Delivery
74
Level––dBA

74
1800 r/min 60
60
72 1800flow
r/min 1200 r/min

%
Efficiency -- %
72 min.
NoiseLevel

min. flow 1200flow


min. r/min 250
min. flow 50
50 250(66)
(66)
70

Efficiency
70
Noise

40
40 200
200(53)
(53)
68 Delivery
Delivery(effective
(effectiveflow)
flow)
68 150
30
30 150(40)
(40)
1200 r/min
66 1200 flow
r/min
66 max. 20
20 100
100(26)
(26)
max. flow
64
64 10
10 50
50(13)
(13)
62 00 00
62 0 50 100 150 200 250 00 50 100 150
0 50 100 150 200 250 50 100 150 200 200 250
250
(700) (1500) (2200) (2900) (3600) (700)
(700) (1500)
(1500) (2200)
(2200) (2900)
(2900) (3600)
(3600)
(700) (1500) (2200) (2900)
Outlet Pressure – bar (psi) (3600)
Outlet Pressure – bar (psi)
Outlet
OutletPressure
Pressure- -bar
bar(psi)
(psi)

Typical Noise Levels at 1500 and 1000 r/min. Input


Typical Noise Levels at 1500 and 1000 r/min. InputTorque
Torqueand
andPower
Poweratat1800
1800r/min,
r/min,50ϒCC(120ϒ
50ϒ F),
(120ϒF),
with Petroleum Oil (10W) at 50°C (120°F) and
and1.0
1.0bar
barabsolute
absolute(0(0psi
psigauge)
gauge)Inlet
Inlet
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet
500
500(4425)
(4425)

(hp)
kW (hp)
450
450(3982)
(3982)

Power –– kW
76
76
400
400(3540)
(3540)
(in.lb.)
Nm (in.lb.)

74 1500 r/min

Input Power
74 1500flow
r/min Input
InputTorque,
Torque,
min. 350
350(3097)
(3097) Full
min. flow FullStroke
Stroke
72
Torque –– Nm

72
dBA

300
300(2655)
(2655)
Level––dBA

70
1500 r/min
1500 flow
r/min Input
70 max. 250
250(2212)
(2212)
max. flow
Input Torque

1000 r/min
1000flow
r/min
NoiseLevel

68 min.
68 min. flow 200
200(1770)
(1770) 100
100(134)
(134)
66 Input
InputPower,
Power,
Input

66 Full
FullStroke
Noise

150
150(1327)
(1327) Stroke 75
75(101)
(101)
64
64 1000 r/min 100
100(885)
(885) Input Torque, 50
InputTorque, 50(67)
(67)
1000 flow
max. r/min
62 max. flow Cut-off
Cut-off
62 50
50(442)
(442) 25
25(34)
(34)
60 00
60 00
00 50
50 100 100 150150 200 200 250 250
58 (700)
(700)(1500)
(1500)(2200) (2900)(3600)
(2200)(2900) (3600)
58 0 50 100 150 200 250
0 50
(700) 100
(1500) 150
(2200) 200
(2900) 250
(3600) Outlet
OutletPressure
Pressure- -bar
bar(psi)
(psi)
(700) (1500) (2200) (2900)
Outlet Pressure – bar (psi) (3600)
Outletdata
Sound pressure Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
equivalent to NFPA.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 61
Performance

Industrial
PVM106

Delivery
Deliveryand
andEfficiency
Efficiencyat
at1500
1500r/min,
r/min,50ϒCC(120ϒ
50ϒ F),
(120ϒF), Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF), Delive
and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet andand
Delivery 1.0 bar absolute
Efficiency at (0 psir/min,
1200 gauge) Inlet
50ϒC (120ϒF), Deliv

(USgpm)
l/min(USgpm)
100 and 1.0 bar absolute (0 psi gauge) Inlet
100 100 100
Volumetric
VolumetricEfficiency
Efficiency
90 100 Volumetric Efficiency 100 V
90 90 Volumetric Efficiency 90
Overall
OverallEfficiency
Efficiency Overall Efficiency

Delivery––l/min
80 90 90
80 80 Overall Efficiency 80
80 80
70
70 70 70

Delivery
70 70

– %– %
60 60 60
60

(USgpm)
60

– %– %
60

Efficiency
50
Efficiency––%%

50 250 250 (66) 50


250(66)

(USgpm)
50 (66)

Efficiency
50 50

Efficiency
40 250 (66) 40
40 200 200 (53)
200(53)
Efficiency

40

Efficiency
(53) 40

– l/min
Delivery 40
Delivery(effective
(effectiveflow)
flow) 30 200(40)
150 (53) 30
30 150
150(40)

– l/min
30 (40) 30 150 (40) 30
20 Delivery (effective flow) 20
100 (26)

Delivery
20 100
20 100(26)
(26) 20 Delivery (effective flow)
100 (26) 20
10 10

Delivery
50 (13)
10 50
10 50(13)
(13) 10
0 50
0 (13)
10
0
00 00 00 50 100 150 200 250
0 00
00 50 100 150 200 250 0 (700)
50 (1500)
100 (2200)
150 (2900)
200 (3600)
250 0
50 100 150 200 250
(700)
(700) (1500)
(1500) (2200)
(2200) (2900)
(2900) (3600)
(3600) (700)
Outlet (1500) (2200)
Pressure – bar (2900)
(psi) (3600)
Outlet Outlet Pressure – bar (psi)
OutletPressure
Pressure––bar
bar(psi)
(psi)

Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),


Input Input and 1.0 and
Torque bar absolute
Power at (0 psir/min,
1200 gauge) Inlet
50ϒ C (120ϒF),
InputTorque
Torqueand
andPower
Powerat
at1500
1500r/min,
r/min,50ϒ
50ϒCC(120ϒF),
(120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet 500 (4425)and 1.0 bar absolute (0 psi gauge) Inlet 50
and 1.0 bar absolute (0 psi gauge) Inlet

(hp)(hp)
500 500 (4425) 5
500(4425)
(4425) 450 (3982) 45
(hp)
kW(hp)

– kW
450 450 (3982) 4
450(3982)
(3982) 400 (3540) 40

– kW

(in.lb.)
Power––kW

(in.lb.)

400 (3540) Input Torque,


(in.lb.)

4
Power
400
400(3540)
Nm(in.lb.)

(3540) 350 (3097) Full Stroke

(in.lb.)
35
(in.lb.)

Input Input Torque,


InputTorque,
Torque, 350 (3097) Full Stroke Power
InputPower

350 3
350(3097) Full
FullStroke

– Nm
(3097) 300 (2655)
– Nm

Stroke 30
Input
Torque––Nm

– Nm
300 (2655)
– Nm

300 3
300(2655) 250 (2212)
Input

(2655) 25

Torque
Input

Torque

250 250 (2212) 2


250(2212)
InputTorque

Torque
(2212) 200 (1770) 100 (134) 20
Torque

) 200 100
100(134) 200 (1770) 100 (134) 2
4) 200(1770)
(1770) (134) 150 (1327) 75 (101) Input
Input

15
Input Power,
Input

Input
Input 75
75(101)
InputPower, 150 (1327) 75 (101)
Input

150 1
) 150(1327)
(1327) Full
Power, (101) 100 (885) Full Stroke
Input Power, 50 (67) 1
FullStroke
Stroke Full Stroke
100 50
50(67) 100 (885) 50 (67)
100(885)
(885) (67) 50 (442) 25 (34)
25 50 (442)
50
50(442)
(442) 25(34)
(34) 0 0
25 (34)

00 00 00 50 100 150 200 250 0


00 50
50 100
100 150150 200200 250 250 0 (700)
50 (1500)
100 (2200)
150 (2900)
200 (3600)
250
(700)
(700) (1500)
(1500)(2200) (2900)(3600)
(2200)(2900) (3600) (700) Pressure
Outlet (1500) (2200)
– bar (2900)
(psi) (3600)
Outlet
Outlet Pressure – bar(psi)
Pressure – bar (psi) Outlet Pressure – bar (psi)

62 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM106

, Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF), Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
Deliveryand
and1.0 bar absolute
Efficiency (0 psi
at 1000 gauge)
r/min, 50ϒCInlet
(120ϒF), Case 50°C (120°F),
Flow versusand 1.0 bar
Outlet absolute
Pressure (0 psir/min,
at 1800 gauge)
FullInlet
Flow,
and 1.0 bar absolute (0 psi gauge) Inlet 4.0 (1.06)
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
100 4.0 (1.06)
100 Volumetric Efficiency
90Volumetric Efficiency 3.5 (0.92)
90 Overall Efficiency 3.5 (0.92)
80

– (USgpm)
Overall Efficiency 3.0 (0.79)
80

– (USgpm)
70 3.0 (0.79)
70 2.5 (0.66)
60
2.5 (0.66)
Delivery – l/min (USgpm)

Delivery – l/min (USgpm)

l/min
Efficiency – %

60
(66) 50 250 (66) 2.0 (0.53)
Delivery – l/min (USgpm)

Delivery – l/min (USgpm)


Efficiency – %

l/min
6) 50 250 (66) 2.0 (0.53)

Flow
(53) 40 200 (53)
1.5 (0.4)

Flow
3) 40 200 (53)
(40) 30 150 (40) 1.5 (0.4)

Case
0) 30 150 (40) 1.0 (0.26)
(26) 20
Delivery (effective flow)
100 (26) Case
20 100 (26) 1.0 (0.26)
6) 10 50 (13)
13) Delivery (effective flow) 0.5 (0.13)
) 10 50 (13) 0.5 (0.13)
0 0
0 0 50 100 150 200 250
0 0
0 50 100 150 200 250
0 (700) 100
50 (1500) 150(2200) 200(2900) 250
(3600)
0 (700) (1500) (2200) (2900) (3600)
(700) Outlet
(1500) (2200)
Pressure (2900)
– bar (psi) (3600) 0 50 100 150 200 250
(700)Outlet Pressure
(1500) – bar (psi)
(2200) (2900) (3600)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

20ϒF), Input Torque and Power at 1000 r/min, 50ϒC (120ϒF), Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
ϒF), and 1.0
Input Torque andbar absolute
Power at 1000(0 psi gauge)
r/min, 50ϒCInlet
(120ϒF), 50°CFlow
Case (120°F), andOutlet
versus 1.0 bar absoluteat(0Cutoff,
Pressure psi gauge) Inlet
1800 r/min,
and
500 (4425) 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
21 (5.55)
Input Power – kW (hp)

Input Power – kW (hp)

500 (4425)
450 (3982) 21
20 (5.55)
Input Power – kW (hp)

(5.28)
450 (3982)
400 (3540) 20
19 (5.28)
(5.02)
Input Torque – Nm (in.lb.)

– (USgpm)

400 (3540) Input Torque, 19 (5.02)


Input Torque – Nm (in.lb.)

350 (3097) Full Torque,


Stroke 18 (4.76)
– (USgpm)

Input
350 (3097) Full Stroke 18
300 (2655) 17 (4.76)
(4.49)
300 (2655) 17 (4.49)
250 (2212) 16 (4.23)
l/min

250 (2212) 16
15 (4.23)
l/min

0 (134) 200 (1770) 100 (134) (3.96)


Flow

(134) 200 (1770) 100 (134) 15 (3.96)


(101) 75 (101) 14 (3.70)
Flow

150 (1327)
Case

Input Power, 14
101)
(67)
150 (1327)
100 (885) Full Power,
Stroke
75 (101)
50 (67) 13 (3.70)
(3.43)
Input
Case

67) 100 (885) Full Stroke 50 (67) 13 (3.43)


12 (3.17)
(34) 50 (442) 25 (34)
34) 50 (442) 25 (34) 12
11 (3.17)
(2.91)
0 0
11 (2.91)
0 0 50 100 150 200 250
0 0
0 (700) (1500)
50 100 (2200) 200
150 (2900) 250(3600) 0 50 100 150 200 250
Outlet Pressure 0 (700) (1500) (2200) (2900) (3600)
(700) (1500) (2200)– (2900)
bar (psi)(3600) 0 50 100 150 200 250
Outlet Pressure – bar (psi) (700)Outlet Pressure
(1500) – bar (psi)
(2200) (2900) (3600)
Outlet Pressure – bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 63
Performance
Typical
Typical Noise Noise
Levels Levels
at 2200 at 2200
& 600 r/min& 600 r/min
with Petroleum
with Petroleum Oil93°C
Oil (10W) at (10W) at 93°C (200°F)
(200°F)
Mobile and 1.0 barand 1.0 bar(0absolute
absolute (0 psi
psi gauge) gauge) Inlet
Inlet
PVM106 86 86

82 82
2200 r/min 2200 r/min
max. flow max. flow 2200 r/min 2200 r/min
78 78 min. flow min. flow
Typical Noise Levels at 2200 & 600 r/min
Noise Level – dBA
Noise Level – dBA

74 74 with Petroleum Oil (10W) at 93°C (200°F)


and 1.0 bar absolute (0 psi gauge) Inlet
86
70 70
600 r/min 600 r/min
min. flow min. flow 82
66 66 2200 r/min
max. flow 2200 r/min
600 r/min 600 r/min min. flow
62 62 max. flow max. flow
78

Noise Level – dBA


58 58
74
54 54
0 0
50 50
100 100
150 150
200 200
250 250
(700) (2200)
(1500) (2900)
(2200) (3600)
(2900) 70
(3600)600 r/min
(700) (1500)
Outlet–Pressure
Outlet Pressure bar (psi) – bar (psi) min. flow
Sound pressure data 66
Sound pressure data
equivalent equivalent
to NFPA. to NFPA. 600 r/min
62 max. flow

58

54
0 50 100 150 200 250
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.

Overall Efficiency
Overall Efficiency versus Speedversus
at Speed at Delivery
Delivery and and Case
Case Flow Flow
versus versus
Speed Speed
at 93°C at 93°C (200°F),
(200°F),
93°C
93°C (200°F) (200°F)
and 1.0 barand 1.0 bar(0absolute
absolute (0 psi
psi gauge) gauge) inlet
inlet Full Flow 1.0 bar absolute (0 psi gauge)
Full Flow 1.0 bar absolute (0 psi gauge) Inlet Inlet
240 (63) 240 (63)
100 100 220 (58)
220 (58)
100 bar 100 bar 50 bar (72550 bar (725
95 150 bar95 150 barpsi) (1450 psi)
(1450 200 (53) 200 (53) psi) Delivery
psi) Delivery
(2200 psi) (2200 psi) 180 (48) 180 (48)
90 90
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)

160 (42) 160 (42)


Overall Efficiency (%)

85 200 bar85 200 bar 210 bar


Case (3000
Flow Case Flow
Overall Efficiency140versus 210 bar (3000 Delivery and C
(2900 psi) (2900 psi) 140 (37) (37) Speed at psi) psi)
Delivery Delivery
l/min l/min
80 80 50 bar 93°C
(725 (200°F) and 1.0 bar absolute (0 psi gauge) inlet
psi) Full Flow
(USgpm)
230psi) 50 barpsi)
bar (3300 (725 psi) (USgpm)
230 bar (3300 120 (32) 120 (32)
75 75 240 (63)
210 bar 100 100 (26) 10 (2.6) 10 (2.6)
210 bar
70 100 (26) 220 (58)
70 (3000 psi) (3000 psi) 100 bar
65 65 95 150 bar 80 (21)
(1450 psi)
80 (21) 8 (2.11)2008(53) (2.11)
(2200 psi) 60 (16) 210psi)
60 (16) 210 bar (3000 bar Case
(3000Flow
psi) Case Flow
6 (1.59) 1806(48)
(1.59)
60 60 90
Delivery – l/min (USgpm)

40 (11) 4 (1.06)1604(42) (1.06)


Overall Efficiency (%)

55 85 200 bar 40 (11)


55 50 bar (725 psi) Case Flow
20 (5) 50 bar (725 psi) Case Flow 2 (0.53)1402(37) (0.53)
50 (2900 psi) 20 (5)
50 80 50 bar (725 psi) 0 0
0 5000 1000 500 15001000 2000
1500 2500
2000 3000 2500 3000 230 bar (3300 psi) 120 (32)
75 0 5000 1000 500 15001000 20001500 2500 2000 2500
Speed – r/min
Speed – r/min 210 bar Speed (r/min)
Speed (r/min) 100 (26)
70 (3000 psi)
65 80 (21)

60 60 (16)
40 (11)
55
20 (5)
64
50
EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
0 500 1000 1500 2000 2500 3000
0
Performance

Mobile
PVM106

Input
Input Torque
Torque versus
versus Speed
Speed at 93°C
at 93°C (200°F),
(200°F), Input
Input Power
Power versus
versus Speed
Speed at 93°C
at 93°C (200°F),
(200°F),
Full
Full Flow
Flow and
and 1.01.0
barbar absolute
absolute (0 psi
(0 psi gauge)
gauge) Inlet
Inlet Full
Full Flow
Flow and
and 1.01.0
barbar absolute
absolute (0 psi
(0 psi gauge)
gauge) Inlet
Inlet
450450 InputTorque
(3982)
Input
(3982) Torqueversus
versusSpeed
Speedatat93°C
93°C(200°F),
(200°F), InputPower
Input Powerversus
versusSpeed
Speedatat93°C
93°C(200°F),
(200°F),
FullFlow
Flowand
and1.0
1.0bar
barabsolute
absolute(0(0psi
psi gauge) Inlet 100100
Full (134)
(134) Flowand
and1.0
1.0bar
barabsolute
absolute(0(0psi
psi gauge) Inlet
Full gauge)
230230
barbar Inlet
(3300
(3300 psi)psi) Full Flow gauge)
230230
barbar Inlet
(3300
(3300 psi)psi)
400400 (3540)
(3540)
450(3982)
450 (3982) 210210
barbar (3000
(3000 psi)psi) 90 90 (121)
(121) 210210
barbar (3000
(3000 psi)psi)
100(134)
100 (134) 150 bar (2200 psi)
150 bar (2200 psi)
Input Torque – Nm (in.lb.)
Nm (in.lb.)

Input Power – kW (hp)


– kW (hp)
350350 (3097)
(3097) 200200
230
230 bar
bar
bar bar (2900
(2900
(3300
(3300 psi)psi)
psi)
psi) 80 80 (107)
(107) 230
230 bar
bar (3300
(3300 psi)
psi)
400 (3540)
400 (3540)
210bar
210 bar(3000
(3000psi)
psi) 9090(121)
(121) 210bar
210 bar(3000
(3000psi)psi)
300300 (2655)
(2655) 70 70
(94)(94) 150 bar (2200 psi)
(in.lb.)

150 bar (2200 psi)


– Nm (in.lb.)

– kW (hp)
200 bar (2900 psi)

– kW (hp)
350(3097)
350 (3097) 200
150 bar
150
bar (2900
bar psi)
(2200
(2200 psi)psi) 8080(107)
(107) 100100
barbar (1500
(1500 psi)psi)
250 (2212) 60 60
(80)(80)
250 (2212)

Input Power
300(2655)
(2655) 7070(94)
(94)
– Nm –

300
50 50
(67)(67)
Input Torque

150bar
150 bar(2200
(2200psi)
psi) 100bar
100 bar(1500
(1500psi)psi)
200200
250 (1770)
(1770)
(2212) 6060(80)
(80)
250 (2212) 100100
barbar (1500
(1500 psi)psi) 40 40
(54)(54)

Input Power
Input Power
5050(67)
(67)
Input Torque
Input Torque

150150
200 (1327)
(1327)
(1770) 30 30
(40)(40)
200 (1770)
100bar
100 bar(1500
(1500psi)
psi) 4040(54)
(54) 50 50
barbar
(725(725
psi)psi)
100100 (885)
(885) 50 50
barbar
(725(725
psi)psi) 20 20
(27)(27)
150
150 (1327)
(1327) 3030(40)
(40)
10 10
(13)(13) 17
50 17
bar
50bar bar
bar(250(250
(725
(725 psi)psi)
psi)
psi)
100
100 50 (442)
50(885)
(442)
(885) 50bar
50 bar (725
(725 psi)
psi) 2020(27)
(27)
17 17
bar bar (250
(250 psi)psi)
0 0
0 0 1010(13)
(13)0 0 5005001000
1000 1500
1500 2000
2000 1717bar
2500
2500 bar
3000(250psi)
(250
3000 psi)
5050(442)
(442)
0 0 5005001000
1000 1500
1500 2000
2000 2500
2500 3000
3000
17bar
bar(250
(250psi)
psi)
17 Speed
Speed (r/min)
(r/min)
Speed
Speed (r/min)
(r/min) 00
00 00 500 1000
500 10001500
1500200020002500
25003000
3000
00 500500 1000
10001500
15002000
20002500
25003000
3000
Speed(r/min)
Speed (r/min)
Speed (r/min)
Speed (r/min)

Input
Input Torque
Torque and andCase CaseFlowFlow versus
versus Speed
Speed at 93°C
at 93°C InputInput Torque
Torque andand Case
Case FlowFlow versus
versus SpeedSpeed at 93°C
at 93°C
(200°F),
(200°F), Load
Load Sense
Sense Standby
Standby and and
1.01.0
barbar absolute
absolute (200°F),
(200°F), Pressure
Pressure Limit
Limit Cut-off
Cut-off and and
1.01.0barbar absolute
absolute
(0 psi
(0 psi gauge)
gauge) Inlet
Inlet (0 psi
(0 psi gauge)
gauge) Inlet
Inlet
InputTorque
Input Torqueand andCaseCaseFlow Flowversus
versusSpeedSpeedatat93°C 93°C InputTorque
Input Torqueand andCaseCaseFlow
Flowversus
versusSpeed Speedatat93°C 93°C
(200°F),
(200°F), LoadSense
SenseStandbyStandbyand and1.01.0bar
barabsolute
absolute 140 (200°F),
140 (1239)
(1239)
(200°F), PressureLimit
Pressure LimitCut-off
Cut-offand and1.01.0bar barabsolute
absolute
12 12 (106)Load
(106)
(0(0psipsigauge)
gauge)InletInlet 130130 (1150)
(1150) (0(0psi
psigauge)
gauge)Inlet Inlet
11 (97)
11 (97) 210210
barbar
(3000(3000 psi)psi)
InputInput Torque
Torque
140
140
120 120(1239)
(1239)(1062)
(1062)
1212(106)
(106) 20 20barbar(300(300psi)psi)
10 10(88)(88) diff.diff. Input
Input Torque
Torque 130
130 (1150)
110(1150)
110
(973)(973)
(Input Torque – Nm (in.lb.)
Nm (in.lb.)

11 (97)
11 (97) 210bar
210 bar(3000
(3000psi) psi)Input
InputTorque
Torque
Input Torque – Nm (in.lb.)
Nm (in.lb.)

9 (80)
9 (80) 20barbar(300
(300psi)
psi) 120
120 (1062)
(1062)
100 (885)
20 100 (885)
1010(88)
(88) diff.Input
diff. InputTorque
Torque CaseCase Case
Case
8 (71)
8 (71) 110
110
90(973)(973)
(in.lb.)

90
(796)(796)
Torque – Nm (in.lb.)

Flow Flow l/min


l/min
(in.lb.)

99(80)
(80) FlowFlow
l/minl/min
– Nm (in.lb.)

7 (62)
7 (62) 11 11barbar
(160(160
psi)psi)
diff.diff. (USgpm)
(USgpm) 100
10080(885)
80 (885)
(708)(708) 150150barbar (2200
(2200 psi)psi)
Input
Input Torque
Torque Case
Case (USgpm)
(USgpm)
– Nm –

88(71)
(71) 90(796)
(796) Input
Input Torque
Torque Case
Case
90
– Nm –

6 (53) 70 70
(619)(619)
(Input TorqueTorque

6 (53) Flow
Flow
9.0 9.0 l/min
l/min(2.38)
(2.38) Flowl/min
Flow l/min
Input Torque

77(62)
(62) 1111barbar(160
(160psi)
psi)diff.
diff. (USgpm)
(USgpm) 80
6080(708)
60 (708)
(531)(531)150150bar
bar(2200
(2200psi)
psi) 30 30
(7.9)
(USgpm) (7.9)
5 (44)
5 (44) Input Torque
Input Torque 8.58.5 (2.25)
(2.25) InputTorque
Torque (USgpm)
Input
66(53)
(53) 9.0 (2.38) 70 70
50(619)
50 (619)
(442)(442) 25 25
(6.6)(6.6)
4 (35) 9.0 (2.38)
(Input (Input

4 (35)
Input Torque
Input Torque

8.08.0 (2.11)
(2.11) 210210barbar (3000
(3000 psi)psi) Case
Case FlowFlow30 (7.9)
30 (7.9)
55(44)
(44) 60 60
40 40 (531)
(531)
(354)(354) 20
20 (5.3) (5.3)
3 (27) 20 20
3 (27) barbar(300 (300
psi)psi) 8.58.5(2.25)
(2.25)
7.57.5 (1.98)
(1.98) 50 (442) 2525 (6.6)
(6.6)
44(35)
(35) diff.diff.
CaseCase Flow 11 11
Flow barbar (160
(160 psi)psi)diff.diff.
8.0 (2.11)
50
30(442)
30
(265)(265) 210barbar(3000
(3000psi)
psi)Case Flow 15 15
CaseFlow (4.0)(4.0)
2 (18)
2 (18) CaseCaseFlowFlow 8.0
7.07.0(2.11)
(1.85)
(1.85) 210
40 40(354)
(354) 150150
barbar (2200
(2200 psi)psi) 202010
10 (5.3)
(5.3)
(2.6)(2.6)
(27) 20
33(27) 20barbar(300
(300psi) psi) 7.5 (1.98) 20 20
(177)(177) Case
Case FlowFlow
1
1 (9) (9) 7.5 (1.98)
diff.Case
diff. CaseFlow Flow 1111bar bar(160
(160psi) diff.6.56.5
psi)diff. (1.72)
(1.72) 3030 (265)
(265)
10 10(88)(88) 1515 (4.0)
(4.0)
5 (1.3)
5 (1.3)
22(18)
(18) CaseFlow
Case Flow 7.07.0(1.85)
(1.85) 150bar
150 bar(2200
(2200psi) psi)
6.06.0 (1.59)
(1.59) 2020(177)
(177) Case Flow 1010(2.6)
(2.6)
(9)0 0 500500 1000 Case Flow
11(9) 1000 1500 1500 2000 2000 2500 2500
6.56.5(1.72)
(1.72) 0 0 500500 1000
1000 1500 1500 20002000 2500
2500
1010(88)(88) 55(1.3)
(1.3)
Speed
Speed (r/min)
(r/min) 6.0(1.59)
6.0 (1.59) Speed
Speed (r/min)
(r/min)
00 500
500 1000 1500
1000 1500 20002000 2500
2500 00 500 1000
500 1000 1500 1500 2000 2000 2500 2500
Speed(r/min)
Speed (r/min) Speed(r/min)
Speed (r/min)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 65
Performance

Industrial
PVM131

Typical Noise Levels at 1800 and 1200 r/min


with Petroleum Oil (10W) at 50°C (120°F) Delivery and Efficiency at 1800 r/min
andNoise
Typical 1.0 barLevels
absolute (0 psiand
at 1800 gauge)
1200Inlet
r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
82 with Petroleum Oil (10W) at 50°C (120°F) 100
and 1.0 bar absolute (0 psi gauge) Inlet Delivery and Efficiency at 1800 r/min
80
82 1800 r/min Volumetric
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Max. Flow 90 Efficiency
1800 r/min 100 Overall Efficiency
78
80
Max. Flow 80
Volumetric
76
78 1800 r/min 90 Efficiency
Min. Flow 70 Overall Efficiency
– dBA

74
76 1800 r/min 80

Efficiency – %
Min. Flow 60 Delivery (effective flow) 240 (63)
– dBA

72
74 70
LevelLevel

1200 r/min 50

Delivery – l/min (USgpm)


200 (53)

Efficiency – %
70 Max. Flow
72 60 Delivery (effective flow) 240 (63)
1200 r/min
NoiseNoise

1200 r/min 40 160 (42)


68 Max. Flow
70 50

Delivery – l/min (USgpm)


Min. Flow 200 (53)
66 1200 r/min 30 120 (32)
68 Min. Flow 40 160 (42)
64
66 20 80 (21)
30 120 (32)
62
64 10 40 (11)
20 80 (21)
60
62 0 0
0 50 100 150 200 250 300 0 10 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) 40 (11)
60 (700) (1500) (2200) (2900) (3600) (4400) (5000)
0 50 Outlet100Pressure
150 – bar
200(psi) 250 300 Outlet Pressure – bar (psi)
(700)
Sound (1500)
pressure data(2200) (2900) (3600) (4400) 0 0
equivalent Outlet
to NFPA 0 50 100 150 200 250 300 350
Pressure – bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Sound pressure data Outlet Pressure – bar (psi)
equivalent to NFPA
Typical Noise Levels at 1500 and 1000 r/min Input Torque and Power at 1800 r/min
with Petroleum Oil (10W) at 50°C (120°F) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Typical
andNoise
1.0 barLevels at 1500
absolute (0 psiand 1000
gauge) r/min
Inlet 720 (6372)
76 with Petroleum Oil (10W) at 50°C (120°F) Input Torque and Power at 1800 r/min
and 1.0 bar absolute (0 psi gauge) Inlet 660 (5841) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
74
76 Max. Flow 720 (6372)
600 (5310)
1500 r/min 660 (5841) Input Torque
72
74 540 (4779)
Input Torque – Nm (in.lb.)

Max. Flow
600 (5310)
480 (4248)
72
70 Input Torque
– dBA

540 (4779)
Input Torque – Nm (in.lb.)

420 (3717) 140 (188)


68
70
– dBA

480
360 (3186)(4248) 120 (161)
LevelLevel

68
66 1000 r/min
Input Power – kW (hp)
Max. Flow 420 (3717) 140 (188)
1000 r/min 300 (2655) Input Power, 100 (134)
64 1000 r/min Full Stroke
NoiseNoise

66 Min. Flow 360 (3186)


240 (2124) 120 (161)
80 (107)
Max. Flow
Input Power – kW (hp)

1000 r/min
64
62 Min. Flow 300 (2655)
180 (1593) Input Power, 100 (134)
60 (81)
Input Full Stroke
Torque,
1500 r/min 240 (2124) 40 (54)80 (107)
60 Min. Flow
62 120 (1062) Cut-off
1500 r/min 180 (1593)
60 (531) 20 (27)60 (81)
58 Min. Flow
60 Input Torque,
1200 (1062) Cut-off 0 40 (54)
56
58 0 50 100 150 200 250 300 350
0 50 100 150 200 250 300 60 (531)(700) (1500) (2200) (2900) (3600) (4400)(5000) 20 (27)
56 (700) (1500) (2200) (2900) (3600) (4400) 0 Outlet Pressure – bar (psi) 0
0 50 Outlet
100 Pressure
150 – bar
200(psi) 250 300 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (700) (1500) (2200) (2900) (3600) (4400)(5000)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

66 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM131

Delivery and Efficiency at 1500 r/min Delivery and Efficiency


Delivery at 1200
and Efficiency r/min
at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C 50°C
(120°F) and 1.0
(120°F) andbar
1.0absolute (0 psi
bar absolute (0gauge) InletInlet
psi gauge)
100 Delivery and Efficiency at 1500 r/min 100 100
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Volumetric
Volumetric
90
100 Efficiency 90 Efficiency
90 Efficiency
Volumetric
8090 EfficiencyOverall Efficiency 80 80
Overall Efficiency
Overall Efficiency

7080 Overall Efficiency 70 70


Efficiency – %

Efficiency – %

Efficiency – %
6070 240 (63) 60 60 240 (63)
240 (63)
Efficiency – %

(USgpm)
5060 50 200 (53)

Delivery – l/min (USgpm)


Delivery (effective flow) 200
240(53) 50 200 (53)

Delivery – l/min (USgpm)


(63)
4050 40 Delivery (effective
Delivery flow)flow)
(effective 160 (42)
(USgpm)
Delivery (effective flow) 160
200(42)
(53) 40 160 (42)
30
– l/min
3040 120
160(32)
(42) 30 120 (32)
120 (32)
2030 20 20 80 (21)
– l/min

80
120(21)
(32) 80 (21)
Delivery

1020 40
80(11)
(21) 10 10 40 (11)
40 (11)
Delivery

010 0 0 0 0 0
0 50 100 150 200 250 300 35040 (11) 0 050 50100 100 150 150 200 200250 250300 300 350 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700)(700)
(1500) (2200) (2900) (3600) (4400)(5000)
(1500) (2200) (2900) (3600) (4400)(5000)
0 0 OutletOutlet
Pressure – bar– (psi)
Pressure bar (psi)
0 50 Outlet
100 Pressure
150 200– bar (psi)
250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

Input Torque and Power at 1500 r/min


50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
720 (6372) Input Torque and Power at 1500 r/min InputInput
Torque and Power
Torque at 1200
and Power r/min
at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C 50°C
(120°F) and 1.0
(120°F) andbar
1.0absolute (0 psi
bar absolute (0gauge) InletInlet
psi gauge)
660 (5841)
720 (6372) 660 (5841)
660 (5841)
600 (5310)
660 (5841) 600 (5310)
Input Torque 600 (5310)
InputInput
Torque
Torque
540 (4779)
Input Torque – Nm (in.lb.)

600 (5310) 540 (4779)


540 (4779)
480 (4248) Input Torque
Input Torque – Nm (in.lb.)

Input Torque – Nm (in.lb.)

540 (4779)
Input Torque – Nm (in.lb.)

480 (4248)
480 (4248)
420 (3717)
480 (4248)
420 (3717)
420 (3717)
360 (3186) 120 (161)
420 (3717)
kW (hp)

360 (3186)
360 (3186)
300 (2655) 100
120(134)
(161)
360 (3186)
300 (2655)
300 (2655) InputInput
Power, 100 (134)
Power, 100 (134)
Input Power – kW (hp)
– kW–(hp)

Input Power – kW (hp)


240 (2124) 80
100(107)
(134)
300 (2655) Full Full
Stroke
Stroke
Input Power, 240 (2124) 80 (107)
60 240 (2124) 80 (107)
180 (1593) Full Stroke 80(81)
Power

240 (2124) (107)


120 (1062) Input Power, 40 (54) 180 (1593)
180 (1593) 60 (81)
60 (81)
180 (1593) Full Stroke 60 (81)
Power

20
40(27)
Input Input

60 (531)
120 (1062) (54) 120 (1062)
120 (1062) 40 (54)
40 (54)
0 020 (27) 60 (531)
60 (531) 20 (27)
20 (27)
60 (531)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400)(5000)
0 0 0 0 0 0
0 50 Outlet
100 Pressure
150 200– bar (psi)
250 300 350 0 050 50100 100 150 150 200 200250 250300 300350 350
(700) (1500) (2200) (2900) (3600) (4400)(5000) (700)(700)
(1500) (2200)
(1500) (2900)
(2200) (3600)
(2900) (4400)
(3600) (5000)
(4400) (5000)
Outlet Pressure – bar (psi) OutletOutlet
Pressure – bar– (psi)
Pressure bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 67
Performance

Industrial
PVM131

Delivery and Efficiency at 1000 r/min Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
Delivery and Efficiency at 1000 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet Case
8 (2.1) Flow Versus Outlet Pressure at Full Flow, 1800 r/min
100 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
Volumetric 8 (2.1)
Volumetric
90 Efficiency
90 Efficiency 7 (1.8)
Overall Efficiency
80 Overall Efficiency 7 (1.8)

(USgpm)
80 6 (1.6)
70

(USgpm)
70 6 (1.6)
5 (1.3)
Efficiency – %

60
Efficiency – %

60

– l/min
5 (1.3)
4 (1.1)

(USgpm)
50 200 (53)

– l/min
l/min(USgpm)
50 200 (53)

FlowFlow
4 (1.1)
40 160 (42) 3 (0.8)
40 160 (42)
Delivery (effective flow)
Delivery (effective flow)

Case
30 120 (32) 3 (0.8)
30
Delivery––l/min

120 (32) 2 (0.5)


20 Case
80 (21) 2 (0.5)
20 80 (21)
1 (0.3)
Delivery

10 40 (11)
10 40 (11)
1 (0.3)
0 0 0
00 50 100 150 200 250 300 350 0 0 50 100 150 200 250 300 350
0 (700)50 (1500)
100(2200)
150(2900)
200(3600)
250 (4400)
300 (5000)
350 0 (700) (1500) (2200) (2900) (3600) (4400) (5000)
(700)Outlet
(1500) (2200) (2900)
Pressure – bar (3600)
(psi) (4400) (5000) 0 50 Outlet
100 Pressure
150 200 – bar 250
(psi) 300 350
Outlet Pressure – bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min


Input Torque and Power at 1000 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1000 r/min Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 24 (6.3)
660 (5841) 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
660 (5841) 24 (6.3)
600 (5310) 20 (5.3)
600 (5310) Input Torque
Input Torque
(USgpm)

540 (4779) 20 (5.3)


540 (4779)
Input Torque – Nm (in.lb.)

(USgpm)

480 (4248)
Input Torque – Nm (in.lb.)

480 (4248) 16 (4.2)


420 (3717) 16 (4.2)
– l/min

420 (3717)
360 (3186) 12 (3.2)
– l/min

360 (3186)
12 (3.2)
FlowFlow

300 (2655) 100 (134)


(hp)

300 (2655) 100 (134)


kW(hp)

Input Power, 8 (2.1)


240 (2124) Input Power, 80 (107)
Case

240 (2124) Full Stroke 80 (107)


Power––kW

Full Stroke 8 (2.1)


60 (81)
Case

180 (1593) 60 (81)


180 (1593) 4 (1.1)
InputPower

120 (1062) 40 (54)


120 (1062) 40 (54) 4 (1.1)
60 (531) 20 (27)
60 (531) 20 (27)
Input

0
0 0 0 50 100 150 200 250 300 350
00 50 100 150 200 250 300 3500 0 (700) (1500) (2200) (2900) (3600) (4400) (5000)
0 (700)50 (1500)
100(2200)
150(2900) 250 (4400)
200(3600) 300 (5000)
350 0 50 Outlet
100 Pressure
150 200
– bar 250
(psi) 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

68 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM131

Typical Noise Levels at 2000 and 600 r/min Delivery and Case Flow Versus Speed
with petroleum
Typical oil (10
Noise Levels atW) @ and
2000 93°C600
(200°F)
r/min @ 93°C (200°F), full flow and
and 1.0 bar absolute (0 psi gauge)
with petroleum oil (10 W) @ 93°C (200°F)inlet 1.0 bar absolute (0 psi) gauge Inlet
84 and 1.0 bar absolute (0 psi gauge) inlet 260 (69) Delivery and Case Flow Versus Speed
84 2000 r/min
82 Max. flow 240 (63) @ 93°C (200°F),
50 bar full flow and
(700 psi),
2000 r/min Delivery (0 psi) gauge Inlet
1.0 bar absolute
82
80 Max. flow 220 (58)
260 (69)
80
78 200 (53)

Delivery – l/min (USgpm)


240 (63) 50 bar (700 psi),
– dBA

78
76 2000 r/min 180 (48) Delivery 280 bar (4000 psi),
Min. flow 600 r/min 220 (58) Delivery
– dBA

76
74 2000 r/min Min. flow
Min. flow 600 r/min 160 (42)
Level

200 (53)

Delivery – l/min (USgpm)

Case Flow – l/min (USgpm)


74
72 Min. flow 140 (37) 280 bar (4000 psi),
Level

180 (48)
72
70 Delivery
Noise

120 (32)
70 160 (42)
68 20 (5.3)
Noise

100 (26)

Case Flow – l/min (USgpm)


140 (37) 280 bar (4000 psi),
68
66 16 (4.2)
80 (21) Case flow
66 600 r/min 120 (32)
64 Max. flow 60 (16) 1220(3.2)
600 r/min 100 (26) (5.3)
64
62 Max. flow 40 (11) 280 bar (4000 psi), 6 (2.1)
80 (21) 16 (4.2)
62
60 Case flow
20 (5) 50 bar (700 psi), Case flow 4 (1.1)
60 (16) 12 (3.2)
60
58 0 0
0 50 100 150 200 250 300 40 (11)
0 500 1000 1500 2000 2500 6 (2.1)
58 (700) (1500)
0 50 100 (2200)
150 (2900)
200 (3600)
250 (4400)
300 20 (5) 50 Speed – r/min
bar (700 psi), Case flow 4 (1.1)
(700) Outlet
(1500)Pressure
(2200) –(2900)
bar (psi)
(3600) (4400)
Sound pressure
Outletdata
Pressure – bar (psi) 0 0
Input Torque Versus Speed
equivalent
Sound to NFPA
pressure data 0 500 1000 1500 2000 2500
@ 93°C (200°F),
Speed –fullr/min
flow and
equivalent to NFPA 1.0 bar absolute (0 psi gauge) inlet
Overall Efficiency Versus Speed 800 (7080) Input Torque Versus Speed
@ 93°C (200°F)
Overall and Versus
Efficiency 1.0 bar Speed
absolute
@ 93°C (200°F), full flow and
(0 psi and
@ 93°C (200°F) gauge)
1.0 inlet
bar absolute 700 (6195) 1.0 bar absolute (0 psi gauge) inlet
95 (0 psi gauge) inlet 800 (7080) 320 bar (4600 psi)
95
Input Torque – Nm (in.lb.)

600 (5310)
700 (6195) 280 bar (4000 psi)
90
100 bar 500 (4425) 320
250 bar
bar (4600
(3600 psi)
psi)
90 (1500 psi)
Input Torque – Nm (in.lb.)

100 bar 600 (5310)


(%)(%)

85 (1500
150psi)
bar 50 bar (700 psi) 400 (3540) 280
200 barbar (4000
(2900 psi)
psi)
Efficiency

(2200 psi) 50 bar (700 psi) 500 (4425) 250 bar (3600 psi)
85 150 bar
Efficiency

(2200 psi) 300 (2655) 150 bar (2200 psi)


80 200 bar 400 (3540) 200 bar (2900 psi)
(2900 psi)
80 200 100 bar (1500 psi)
Overall

bar 200 (1770)


(2900
250 psi)
bar 300 (2655) 150 bar (2200 psi)
Overall

75
(3600 psi) 100 (885) 50 bar (700 psi)
75 250 bar
(3600 psi)
280 bar 200 (1770) 100 bar (1500 psi)
17 bar (250 psi)
(4000 psi)
70 280 0
bar
0
100 (885) 500 1000 1500 2000 50 bar
2500
(700 psi)
70 (4000 psi)
320 bar Speed – r/min
(4600 psi) 17 bar (250 psi)
65 320 bar
0(4600 psi)500 1000 1500 2000 2500 0
65 Speed –1500
r/min 0 500 1000 1500 2000 2500
0 500 1000 2000 2500 Speed – r/min
Speed – r/min

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 69
Performance

Mobile
PVM131

Input Power Versus Speed Input Torque and Case Flow Versus Speed
@93°C (200°F),
Input Power full flow
Versus and
Speed @ 93°C (200°F), cut-off and
1.0@93°C
bar absolute (0 psi
(200°F), full gauge)
flow andinlet 1.0 bar absolute (0 psi gauge) inlet
140 (188) 1.0 bar absolute (0 psi gauge) inlet 260 (2301)
320 bar (4600 psi) 280 bar (4000 psi)
140
130 (188)
(174) 240 (2124)
320 bar (4600 psi) Input Torque
130 (174)
120 (161) 280 bar (4000 psi)
220 (1947)
120 280 bar (4000 psi)
110 (161)

Input Torque – Nm (in.lb.)


(148) 250 bar (3600 psi) 200 (1770)
110 (148) 250 bar (3600 psi)
(hp)

100 (134) 180 (1593)

Case Flow – l/min (USgpm)


(hp)

100
90 (134)
(121) 200 bar (2900 psi) 160 (1416)
– kW

90
80 (121)
(107) 200 bar (2900 psi)
– kW

140 (1239) 56 (14.8)


80
70(107)
Power

(94) 150 bar (2200 psi) 120 (1062) 48 (12.7)


150 bar (2200 psi)
Power

70
60 (94)
(80) 150 bar (2200 psi)
100 (885) Input Torque 40 (10.6)
60
50 (80)
Input

(67)
100 bar (1500 psi) 80 (708) 280 bar (4000 psi), Case Flow 32 (8.5)
Input

50
40 (67)
(54)
100 bar (1500 psi) 60 (531) 24 (6.3)
40
30 (54)
(40)
50 bar (700 psi) 40 (354) 16 (4.2)
30
20 (40)
(27) 150 bar (2200 psi), Case Flow 8 (2.1)
50 bar (700 psi) 20 (177)
20 (27)
10 (13) 17 bar (250 psi) 0 500 1000 1500 2000 2500
10 (13) 17 bar (250 psi) Speed – r/min
0
0 500 1000 1500 2000 2500 Case Flow at 2000 r/min, Full Flow
0
0 500 Speed – r/min
1000 1500 2000 2500 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Speed – r/min 18 (4.7)
Case Flow – l/min (USgpm)

16 (4.2)
14 (3.7)
Input Torque and Case Flow Versus Speed
Input@Torque
93°C (200°F),
and CaseloadFlow
sense standby
Versus Speed 12 (3.2)
and 1.0 bar
@ 93°C absolute
(200°F), (0sense
load psi gauge) inlet
standby 10 (2.6)
and 1.0 bar absolute (0 psi gauge) inlet 8 (2.1)
18 (159)
18 (159) 20 bar (300 psi) 6 (1.6)
16 (142) differential, 4 (1.0)
20 bar (300 psi)
16 (142) Input Torque
differential, 2 (0.5)
(in.lb.)

14 (124) Input Torque 0 50 100 150 200 250 300 350


(in.lb.)

14 (124) (700) (1500) (2200) (2900) (3600) (4400) (5000)


12 (106) 11 bar (160 psi) Outlet Pressure – bar (psi)
– Nm

12 (106) differential,
11 bar (160 psi)
– Nm

Case Flow at 2000 r/min, Minimum Flow


(USgpm)

10 (88) Input Torque


differential,
Case Flow – l/min (USgpm)

93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet


(USgpm)
Torque

10 (88) Input Torque


8 (71) 7 (1.85) 28 (7.4)
Torque

8 (71) 7 (1.85) 24 (6.3)


(l/min

20 bar (300 psi) differential 6 (1.58)


Input

6 (53)
Case 20 (5.3)
barFlow
(l/min

20 (300 psi) differential 6 (1.58)


Input

6 (53)
4 (35) Case Flow 5 (1.32) 16 (4.2)
Flow

4 (35) 5 (1.32) 12 (3.2)


Flow

2 (18) 11 bar (160 psi) differential 4 (1.06)


Case

Case 8 (2.1)
2 (18) 11 barFlow
(160 psi) differential 4 (1.06)
Case

0 Case Flow 3 (0.79) 4 (1.0)


0 50 100 150 200 250 300 350
00 500 1000 1500 2000 25003 (0.79) (700) (1500) (2200) (2900) (3600) (4400) (5000)
0 500 Speed – r/min
1000 1500 2000 2500 Outlet Pressure – bar (psi)
Speed – r/min

70 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM141

Typical Noise Levels at 1800 and 1200 r/min Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
Typical Noise Levels
with Petroleum at 1800
Oil (10W) atand
50°C1200 r/min
(120°F) and 1.0 bar absolute (0 psi gauge) Inlet
with
and Petroleum Oil (10W)
1.0 bar absolute at gauge)
(0 psi 50°C (120°F)
Inlet Delivery
100 and Efficiency at 1800 r/min, 50ϒC (120ϒF),
84 and 1.0 bar absolute (0 psi gauge) Inlet and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
84 100
90
82 1800 r/min
1800 r/min
max. flow Overall Efficiency
Volumetric Efficiency
82 90
80
80 max. flow
80 Overall Efficiency
78 80
70

– %– %
78
– dBA

76 70
60 300 (79)

(USgpm)
– dBA

76

Efficiency
1200 r/min Delivery (effective flow)
74 60
50 300
250 (79)
(66)
1200 r/min
max. flow

(USgpm)
74
Level

Efficiency
72 max. flow Delivery (effective flow)
Level

50
40 250
200 (66)
(53)
72 1800 r/min

– l/min
70
Noise

1800 r/min
min. flow 40
30 200
150 (53)
(40)
70
Noise

min. flow

– l/min
68
68 30
20 150
100 (40)
(26)

Delivery
66
66 20
10 100 (26)
50 (13)

Delivery
64 1200 r/min
64 1200 r/min
min. flow
min. flow 100 50
0 (13)
62 0 50 100 150 200 250
62 (700) (1500) (2200) (2900) (3600)0
60 0
60 0 50 100 150 200 250 0 50 100
Outlet
150
Pressure – bar
200
(psi)
250
0 (700)
50 (1500)
100 (2200)
150 (2900)
200 (3600)
250 (700) (1500) (2200) (2900) (3600)
(700)Outlet(1500)
Pressure(2200) (2900) (3600)
– bar (psi)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),


Typical Noise Levels 1500 and 1000 r/min and 1.0 bar absolute (0 psi gauge) Inlet
Typical Noise Levels
with Petroleum 1500at
Oil (10W) and 1000
50°C r/min
(120°F) Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),

kW (hp)
with 600 (5310)
and 1.0 bar absolute (0 psi gauge) Inlet
and Petroleum Oil (10W)
1.0 bar absolute at gauge)
(0 psi 50°C (120°F)
Inlet
and 1.0 bar absolute (0 psi gauge) Inlet

– kW– (hp)
78 550 (4867)
600 (5310)
78
76 500 (4867)
550 (4425)

Power
76 1500 r/min
Nm (in.lb.)

74 1500 450 (4425)


500 (3982)
r/min
max. flow Input Torque,

Power
74 max. flow
– Nm– (in.lb.)

72 400 (3982)
450 (3540) Full Stroke

InputInput
1000 r/min Input Torque,
72 1000 r/min
max. flow 350 (3540)
400 (3097)
70 Full Stroke
– dBA

70 max. flow
300 (3097)
350 (2655) 150 (201)
Torque
– dBA

68
68 1500 r/min 250 (2655)
(2212) Input Power, 125 (201)
(168)
300 150
Torque

66 1500 r/min
min. flow
Level

Full Stroke
66 min. flow 200 (2212)
(1770) 100 (168)
(134)
Level

250 125
InputInput

Input Power,
64 Full Stroke
150 (1770)
(1327) 75 (101)
Noise

64 1000 r/min 200 100 (134)


62
Noise

1000 r/min
min. flow 100 (885) 50 (101)
(67)
62 min. flow 150 (1327) Input Torque, 75
60 50 (442) Cut-off
60 100 (885) Input Torque, 25 (67)
50 (34)
58 Cut-off
58 50 (442)0 0
25 (34)
56 0 50 100 150 200 250
56 0 0
(700) (1500) (2200) (2900) (3600)
54 0 50 100 150 200 250
Outlet Pressure – bar (psi)
54 0 50 100 150 200 250 (700) (1500) (2200) (2900) (3600)
0 (700)
50 (1500)
100 (2200)
150 (2900)
200 (3600)
250
(700)Outlet(1500)
Pressure(2200) (2900)
– bar (psi) (3600) Outlet Pressure – bar (psi)
Outletdata
Sound pressure Pressure – bar (psi)
Sound pressure
equivalent data
to NFPA.
equivalent to NFPA.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 71
Performance

Industrial
PVM141

Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF), Delivery and Efficiency at 1200 r/min, 50°C (120°F), Deliv
and 1.0 bar absolute (0 psi gauge) Inlet and
Delivery 1.0Efficiency
and bar absolute (0 psi
at 1200 gauge)
r/min, 50°CInlet
(120°F), Deliv
Delivery
100 and Efficiency at 1500 r/min, 50ϒC (120ϒF), and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet 100 10
10090 Volumetric Efficiency 100 Volumetric Efficiency 10
90 Volumetric Efficiency 9
Volumetric Efficiency
Overall Efficiency 90 Overall Efficiency 9
9080 80 Overall Efficiency 8
Overall Efficiency 80 8
8070 70 7
70

–%
7
Efficiency – %

7060

–%
300 (79) 60 300 (79) 6

–%
Delivery – l/min (USgpm)

–%
Delivery – l/min (USgpm)

(USgpm)
60 300 (79)

Efficiency
6
Efficiency – %

Efficiency
6050 300
250(79)
(66) 50 250 (66) 5

(USgpm)
Efficiency

Efficiency
Delivery (effective flow) Delivery – l/min (USgpm) 50 250 (66) 5
5040 250
200(66)
(53) 40 200 (53) 4
Delivery (effective flow) 40 200 (53) 4

– l/min
4030 200
150(53)
(40) 30 150 (40) 3

– l/min
30 Delivery (effective flow) 150 (40)
3020 3
150
100(40)
(26) 20 Delivery (effective flow) 100 (26) 2

Delivery
20 100 (26) 2

Delivery
2010 100
50 (26)
(13) 10 50 (13) 1
10 50 (13) 1
10 0 500 (13) 0 0
0 50 100 150 200 250 0 0 50 100 150 200 250
0
0 (700) (1500) (2200) (2900) (3600)0 0 (700)
50 (1500)
100 (2200)
150 (2900)
200 (3600)
250
0 50Outlet100 150
Pressure – bar 200
(psi) 250 (700)
Outlet(1500) (2200)
Pressure – bar(2900)
(psi) (3600)
(700) (1500) (2200) (2900) (3600)
Outlet Pressure – bar (psi)
Outlet Pressure – bar (psi)

, Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),


and 1.0 bar absolute (0 psi gauge) Inlet Input Torque and Power at 1200 r/min, 50°C (120°F), Inp
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF), and 1.0
Input Torque barPower
and absolute (0 psi
at 1200 gauge)
r/min, Inlet
50°C (120°F), Inp
Input Power – kW (hp)

and 1.0 bar absolute (0 psi gauge) Inlet


600 (5310) and 1.0 bar absolute (0 psi gauge) Inlet

(hp)
600 (5310) 60

(hp)
Input Power – kW (hp)

550(5310)
600 (4867) 600 60
550(5310)

– kW
(4867) 55
500(4867)
550 (4425)

– kW
550 55
500(4867)
(4425) 50
Input Torque – Nm (in.lb.)

Power
450(4425)
500 (3982) 50

(in.lb.)
500 (4425)
(in.lb.)

Input Torque, 450 (3982) 45


Power

(in.lb.)
400(3982)
(3540)
(in.lb.)
Input Torque – Nm (in.lb.)

450 450 45
Full Stroke
Input Torque, 400(3982)
(3540) Input Torque,
Full Stroke Input 40
350(3540)
(3097) Input Torque,

– Nm
400 40
– Nm

Full Stroke 400 (3540)


350 (3097) Full Stroke 35
Input

– Nm
1)
– Nm

300(3097)
350 (2655) 150 (201) 350 35
300(3097)
(2655) 150 (201) 30

Torque
)8)
Torque

250(2655)
300 (2212) 125(201)
150 (168) 300 (2655) 150 (201) 30

Torque
25
Torque

250 (2212) 125 (168)


)4) 200(2212)
250 (1770) Input Power, 100(168)
125 (134) 250 25
Full Stroke 200(2212)
(1770) 125 (168)
100 (134) Input 20
)
Input

150(1770)
200 (1327) Input Power, 75 (134)
100 (101) 200 (1770) 20
100 (134)
Input
150 (1327) Input Power, 15
Input

Full Stroke 75 (101)


150100 (885)
(1327) 7550(101)
(67) 150 (1327) Full Stroke
Input Power, 75 (101) 151
100 (885) Full Stroke 50 (67)
10050(885)
(442) 5025(67)
(34) 100 (885)
50 (442) 50 (67) 1
25 (34)
50 (442) 0 0
25 (34) 50 (442)0 25
0 50 100 150 200 250 0 (34)
0 (700) (1500) (2200) (2900) (3600)0 0 0 50 100 150 200 250
0
0 50 100 150 200 250 0 (700)
50 (1500) 150 (2900)
100 (2200) 200 (3600)
250
Outlet
(700) Pressure
(1500) – bar
(2200) (psi) (3600)
(2900) (700)
Outlet(1500) (2200)
Pressure (2900)
– bar (psi) (3600)
Outlet Pressure – bar (psi) Outlet Pressure – bar (psi)

72 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Industrial
PVM141

Delivery and Efficiency at 1000 r/min, 50°C (120°F), Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
Delivery and
and Efficiency
1.0 at 1000
bar absolute r/min,
(0 psi 50°CInlet
gauge) (120°F), 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
and 1.0 bar absolute (0 psi gauge) Inlet
100 7,6 (2.0)
100 Volumetric Efficiency
90 Volumetric Efficiency
90 Overall Efficiency 6,6 (1.75)
80 Overall Efficiency

Case Flow - l/min (USgpm)


80 5,7 (1.5)
70
70
–%

79) 60 300 (79) 4,7 (1.25)


–%

(USgpm)
9) 60
(USgpm)

300 (79)
Efficiency

(USgpm)
(USgpm)

66) 50 250 (66)


Efficiency

6) 50 250 (66) 3,8 (1.0)


53) 40 200 (53)
3) 40 200 (53)
– l/min 2,8 (0.75)
– l/min

40) Delivery (effective flow) – l/min


30 150 (40)
– l/min

0) Delivery (effective flow)


30 150 (40)
26) 20 100 (26) 1,9 (0.5)
Delivery
Delivery

6) 20 100 (26)
Delivery
Delivery

3) 10 50 (13)
) 0,9 (0.25)
10 50 (13)
0 0
0 0 50 100 150 200 0
250 0
0 50
(700) 100
(1500) 150
(2200) 200
(2900) 250
(3600) 0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (700) (1500)(2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi) Outlet Pressure - bar (psi)
Outlet Pressure – bar (psi)

0°F), Input Torque and Power at 1000 r/min, 50°C (120°F),


°F), Input Torque and
and 1.0 Power
bar at 1000
absolute r/min,
(0 psi 50°CInlet
gauge) (120°F), Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
and 1.0 bar absolute (0 psi gauge) Inlet 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
(hp)

(hp)

600 (5310) 22,7 (6)


(hp)

(hp)

600 (5310)
– kW

550 (4867)
– kW
– kW

550 (4867)
– kW

500 (4425) 18,9 (5)


Power

500 (4425)
Power
(in.lb.)

450 (3982)
Power

Case Flow - l/min (USgpm)

Input Torque,
Power
(in.lb.)

450 (3982) Input Torque,


Full Stroke
400 (3540) Full Stroke
Input

400 (3540) 15,1 (4)


Input
– Nm
Input

350 (3097)
Input
– Nm

350 (3097)
0 (201) 300 (2655) 150 (201)
Torque

(201) 300 (2655) 150 (201) 11,4 (3)


Torque

5 (168) 250 (2212) 125 (168)


(168) 250 (2212) 125 (168)
0 (134) 200 (1770) 100 (134)
Input

(134) 200 (1770) 100 (134)


Input

150 (1327) Input Power, 75 (101) 7,6 (2)


(101) Input Power,
101) 150 (1327) Full Stroke 75 (101)
(67) 100 (885) Full Stroke 50 (67)
67) 100 (885) 50 (67)
(34) 50 (442) 25 (34) 3.8 (1)
34) 50 (442) 25 (34)
0 0
0 0 50 100 150 200 0
250
0 50
(700) 100 (2200)
(1500) 150 (2900) 250
200 (3600) 0
(700) (1500) (2200) (2900) (3600) 0 50 100 150 200 250 300 350
Outlet Pressure – bar (psi) (700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Outlet Pressure - bar (psi)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 73
Performance

Mobile
PVM141

TypicalNoise
Typical NoiseLevels
Levelsatat2000
2000andand1000
1000r/min
r/min
withPetroleum
with PetroleumOil Oil(10W)
(10W)atat93°C Typicaland
93°C(200°F),
(200°F), Noise
and Levels at 2000 and 1000 r/min
1.0bar
1.0 barabsolute
absolute(0(0psipsigauge) with
gauge)Inlet Petroleum
Inlet Oil (10W) at 93°C (200°F), and
8888 1.0 bar absolute (0 psi gauge) Inlet
88
8686
2000r/min
2000 86
r/min
8484 min.flow
min. flow 2000 r/min
84 min. flow
8282
Noise Level – dBA
Noise Level – dBA

82

Noise Level – dBA


8080
2000r/min
2000 r/min 80
7878 max.flow
max. flow 2000 r/min
78 max. flow
7676
76
7474 1000r/min
1000 r/min
min.flow
min. flow 74 1000 r/min
7272 min. flow
72
7070
70
1000r/min
1000 r/min
6868 max.flow
max. flow 1000 r/min
68 max. flow
6666
66
6464
00 5050 100
100 150 64 200
150 200 250
250
(700) (1500)
(700) (2200) 0(2900)
(1500) (2200) (2900) 50 (3600) 100
(3600) 150 200 250
OutletPressure
Outlet Pressure– –bar bar(psi)
(psi) (700) (1500) (2200) (2900) (3600)
Soundpressure
Sound pressuredata
data Outlet Pressure – bar (psi)
equivalenttotoNFPA.
equivalent NFPA. Sound pressure data
equivalent to NFPA.

OverallEfficiency
Overall Efficiencyversus
versusSpeed
Speedatat93°C93°C(200°F),
(200°F), Deliveryand
Delivery andCase
CaseFlow
Flowversus
versusSpeed
Speedatat
andand1.01.0bar
barabsolute
absolute(0(0psi Overall
psigauge)
gauge) Efficiency versus Speed
Inlet
Inlet 93°Cat 93°C
93°C (200°F),
(200°F),
(200°F), FullFlow
Full Flowandand1.01.0bar Delivery
absoluteand Case Flow ver
barabsolute
and 1.0 bar absolute (0 psi gauge) Inlet(0(0psi psigauge) Inlet 93°C (200°F), Full Flow and 1
gauge)Inlet
100
100 280(74)
280 (74) (0 psi gauge) Inl
100 280 (74)
260(69)
260 (69)
9595 260 (69)
95 240(63)
240 (63) 100bar
100 bar
100
9090100 barbar (1500
(1500 psi)
psi)
psi) (63)
240
Delivery – l/min (USgpm)

(1500psi) 100 bar


Delivery – l/min (USgpm)

220(58)
220 (58) (1500
150
150 barbar (2200
(2200 psi)
psi) 90 100 bar (1500 psi)
Delivery – l/min (USgpm)

Delivery
Delivery 220 (58) (1500 psi)
Overall Efficiency (%)
Overall Efficiency (%)

8585 150 bar (2200 psi) 200(53)


200 (53)
5050 bar Delivery
Overall Efficiency (%)

85 bar 210bar
210
200 bar(3000
(53) (3000
210 bar (3000 psi)
8080210 bar (3000 psi) 210 bar
(700psi)
(700
(3000 psi)
psi) 180(48)
180 (48) 50 bar psi)Delivery
psi) Delivery 2
230
230 barbar (3300
(3300 psi)
psi) 80 160(42)
(42) (700 psi) 180 (48) p
7575 160 Case
Case
230 bar (3300 psi) 160 (42) Flow
Flow
75 140(37)
140 (37) l/min
l/min
7070 120 (32)
140 (37) (USgpm)
(USgpm)
70 120 (32)
6565 210bar
210 120
bar(3000 (32)
(3000 1010(2.6)(2.6)
100(26)
100 (26) 210 bar (
65 psi)Case
psi) Case Flow
Flow
100 (26)
6060 8080(21)
(21) 8 8(2.1)
(2.1) psi) Case
60 6060(16)
(16) 80 (21) 6 6(1.6)
(1.6)
5555 60 (16) 4 (1.1)
55 4040(11)
(11) 4 (1.1)
5050 40 (11) 2
2 (0.5)(0.5)
2020(5)(5) 100bar
100 bar(1500
(1500psi)
psi)Case
CaseFlow
Flow
50 20 (5) 01000 bar (1500 psi)
00 500
500 1000
1000 1500
1500 2000
2000 2500
2500 00 500 1000
500 1000 1500 1500 2000 2000 2500 2500
0 500 1000 1500 2000 2500 0 500 1000 1500
Speed(r/min)
Speed (r/min) Speed(r/min)
Speed (r/min)
Speed (r/min) Speed (r/min)

74 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance

Mobile
PVM141

Input Torque versus


Input Speed at 93°C (200°F),
InputTorque
Input Torqueversus
Torque versusSpeed
versus Speedat
Speed at93°C
at 93°C(200°F),
93°C (200°F),
(200°F), Input
InputPower versus
InputPower
Input Power
Speed, 93°C
Powerversus
versusSpeed,
versus Speed,93°C
Speed,
(200°F),
93°C(200°F),
93°C (200°F),
(200°F),
FullFull
Flow andand
Flow 1.01.0
barbar
absolute (0 psi
absolute (0 gauge)
psi Inlet
Full
FullFlow
Flowand
and1.0
1.0bar
barabsolute
absolute(0 psigauge)
(0psi gauge)Inlet
gauge) Inlet
Inlet andand1.01.0
and
barbar
and1.0
absolute
1.0bar
(0 psi
absolute
barabsolute (0
absolute(0
gauge)
psi
(0psi
Inlet
gauge)
gauge)Inlet
psigauge) Inlet
Inlet
600600
(5310)
(5310) 120120
(161)
(161)
600
600(5310)
(5310) 120
120(161)
(161) 230230 barbar
550550
(4867) 230
230 bar
bar
550(4867)
550 (4867)
(4867) 230230
bar (3300 psi) 110110
(148)
110 (148)
110(148)
(148)
(3300
(3300psi)
(3300psi)
(3300 psi)
psi)
500500
(4425)
(4425) 230bar
230 bar(3300
bar (3300psi)
(3300 psi)
psi) 210210 barbar
500
500(4425)
(4425) 210210
barbar
(3000 psi)
(3000 psi) 100100
(134)
(134) (3000210
210 bar
bar
psi)
Input Torque – Nm (in.lb.)

100
100(134)
(134) (3000
(3000psi)
(in.lb.)

210
210bar
bar(3000
(3000psi)
psi) (3000 psi)
psi)
(in.lb.)
Nm(in.lb.)

450450
(3982)
450(3982) 90 90
(121)

Input Power – kW (hp)


(121)

(hp)
450 (3982)
(3982) 90
90(121)
(121)

(hp)
kW(hp)
400400
(3540)
400(3540)
400 (3540)
(3540) 80 80
(107)
80(107)
80 (107)
(107) 150150 barbar
Nm
––Nm

150
150 bar
bar

kW
––kW
(2200
(2200psi)
350350
(2655)
350(2655)
350 (2655)
(2655)
150150
bar (2200
150bar
150 bar
psi)
bar(2200
(2200psi)
(2200 psi)
psi) 70 70
(94)(94) (2200psi)
(2200 psi)
psi)
70
70(94)
(94)
Torque–

Power–
300300
(2655)
(2655)
Torque
Input Torque

Power
Input Power
300
300(2655)
(2655) 60 60
(80)(80)
60
60(80)
(80) 100100barbar
250250
(2212)
250(2212)
250 (2212)
(2212) 100100
bar (1500
100bar
psi)
bar(1500
(1500psi) 50 50
(67)(67) (1500100
100
(1500
bar
bar
psi)
100 bar (1500 psi)
psi) 50
50(67)
(67) (1500psi)
(1500 psi)

Input
psi)
Input

Input
200200
(1770)
Input

200 (1770)
200(1770)
(1770) 40 40
(54)(54)
40
40(54)
(54)
150150
(1327)
150(1327)
150 (1327)
(1327) 30 30
(40)(40) 50 50
barbar
50
50 bar
bar
30
30(40)
(40) (700(700psi)
100100
(885) (700psi)
(700 psi)
psi)
100(885)
100 (885)
(885) 50 50
barbar
50
(725 psi)
bar(725
50bar (725psi)
(725 psi)
psi) 20 20
(27)(27)
17 17
barbar
(250 psi)psi) 20
20(27)
(27) 17 17
barbar
50 (442)
50 (442) 17
17bar (250
bar(250
(250psi)
psi) 17
17 bar
bar
50
50(442)
(442) 10 10
(13)(13) (250(250psi)
0 0
10
10(13)
(13) (250psi)
(250 psi)
psi)
00
0 0 5005001000 1500 2000 2500 3000
00 500 1000
500 1000 1500
1000 1500 2000
1500 2000 2500
2000 2500 3000
2500 3000
3000 0 0
00
500500 1000
500
500 1000
1000
1500
1000 1500 1500
2000
1500 2000
2000
2500
2000 2500
2500
2500
Speed (r/min)
Speed (r/min) Speed (r/min)
Speed (r/min)
Speed
Speed(r/min)
(r/min) Speed
Speed(r/min)
(r/min)

Input Torque andandCase Flow versus Speed at 93°C Input


InputTorque andandCase Flow versus Speed
Input
InputTorque
Input Torque andCase
Torqueand CaseFlow
Case Flowversus
Flow versusSpeed
versus Speedat
Speed at93°C
at 93°C
93°C InputTorque
Input Torque andCase
Torqueand CaseFlow
Case Flowversus
Flow versusSpeed
versus Speed
Speed
(200°F), Load Sense Standby andand
1.01.0
barbar
absolute at 93°C
at (200°F),
93°C Pressure
(200°F), Limit
Pressure Cut-Off
Limit and
(200°F),
(200°F), Load
(200°F),Load Sense
LoadSense Standby
SenseStandby
Standbyand and1.0
1.0bar absolute
barabsolute
absolute atat93°C
93°C(200°F),
(200°F),Pressure LimitCut-Off
PressureLimit Cut-Offand
Cut-Off and
and
(0 psi gauge) Inlet 1.01.0
barbar
absolute (0 psipsi
gauge) Inlet
(0(0psi
(0 psigauge)
psi gauge)Inlet
gauge) Inlet
Inlet 1.0 barabsolute
1.0bar absolute(0
absolute (0 psigauge)
(0psi gauge)Inlet
gauge) Inlet
Inlet
110110
(973)
14 (124)
1414(124)
14 (124)
(124) 110(973)
110 (973)
(973)
13 (115)
13 (115) 100100
(885)
13 (115)
13 (115) 20 20barbar(290 psi)
(290 100(885)
100 (885)
(885)
12 (106)
1212(106)
12 (106)
(106) 20
20
diff.diff.bar
Input (290psi)
(290
barTorque psi)
psi) 90 (796)
Input
InputTorque 9090(796)
Input Torque – Nm (in.lb.)

diff.
diff.Input Torque
Torque 90 (796)
(796)
(in.lb.)

11 (97) 210210barbar
(3000 psi)
1111(97) bar(3000
(3000psi)
Input Torque – Nm (in.lb.)

(in.lb.)
Nm(in.lb.)
(in.lb.)

11 (97)
(97) 210
210 bar (3000 psi)
psi)
(in.lb.)
Nm(in.lb.)

11 bar11 (160
bar psi)
(160 80 (708)
10 (89)
10
10(89)
10 (89)
(89) 11
11
diff.diff. bar (160psi)
(160
barTorque
Input psi)
psi) 80
80 (708)
80(708)
(708) Input Torque
Input
Input Torque
InputTorque
Torque
diff. Input
InputTorque
diff.Input Torque Case
Torque Case 150150barbar
(2200 psi)psi)
(2200
9 (80)
999(80) Case
Case 70 (619)
70 150
150 bar
bar(2200
(2200psi)
psi)
(80)
(80) Flow l/min
Flow l/min 70(619)
70 (619)Input
(619) Torque
Input
InputTorque
Nm
––Nm

Flow
Flow l/min
l/min Input Torque
Torque
Nm
––Nm

8 (71)
888(71) (USgpm)
(USgpm) 60 (531) Case Case FlowFlow
(71)
(71) (USgpm)
(USgpm) 6060(531)
60 (531)
(531) Case
Case Flow
Flow
l/min
Torque–

7 (62)
777(62) 6.56.5
(1.72) l/min
6.5 (1.72) l/min
l/min
Torque–

(62)
(62) 6.5 (1.72)
Torque

(1.72)
Input Torque

20 20barbar(290
(290psi)psi) 50 (442)
50 (USgpm)
(USgpm)
50(442)
Torque
Input Torque

6 (53)
666(53) 20
20 bar
bar (290
(290 psi)
psi) 6.0 (1.58)
6.0 (1.58) 50 (442)
(442) (USgpm)
(USgpm)
(53)
(53) diff.diff.
Case Flow
Case Flow 6.0
6.0 (1.58)
(1.58)
diff.
diff.Case
CaseFlow Flow 20 (5.3)
20
5 (44)
555(44)
(44)
(44) 5.55.5
(1.45)
5.5 (1.45)
5.5 (1.45)
(1.45)
40 (354)
4040(354)
40 (354)
(354) 20(5.3)
20 (5.3)
(5.3)
210210barbar
(3000 psi)psi)
Input

4 (35)
444(35) 5.05.0
(1.32) (3000
Input

5.0 (1.32)
Input

(35)
(35) 30 (265)
30 210
210 bar
bar (3000
(3000 psi)
psi) 15 (2.6)
15 (2.6)
5.0 (1.32)
(1.32) 30(265)
Input

CaseCaseFlow
3 (27)
333(27) 4.54.5
(1.19)
(1.19) 30 (265)
(265) CaseFlow
Case Flow
Flow 15
15(2.6)
(2.6)
(27)
(27) 11 bar
11 (160
bar psi) 4.5
4.5 (1.19)
(1.19) 150150
barbar
(2200 psi) 10 (4.0)
10 (4.0)
2 (18)
222(18)
(18)
(18) 11
11
diff.diff.
Case bar(160
bar (160psi)
(160
Flow psi)
psi) 4.04.0
(1.06)
4.0 (1.06)
4.0 (1.06)
(1.06)
20 (177)
2020(177)
20 (177)
(177) 150
150 bar(2200
bar (2200psi)
(2200 psi)
psi) 10
10(4.0)
(4.0)
diff. Case
diff.Case
CaseFlowFlow
Flow Case Flow
Case Flow 5 (1.3)
5 (1.3)
1 (9)1 (9) 3.53.5
(0.92) Case
Case Flow
Flow
11(9)
(9) 3.5 (0.92)
3.5 (0.92)
(0.92) 10 (88)
10
10(88)
10 (88)
(88) 55(1.3)
(1.3)
3.03.0
(0.79) 0 0
3.0 (0.79)
3.0 (0.79)
(0.79) 00
0 0 500500 1000 1500 2000 2500 0 0
00 500 1000
500 1000 1500
1000 1500 2000
1500 2000 2500
2000 2500
2500 00 500500 500
500
1000
1000
1000
1500 2000
1000 15001500 2000
1500 2000
2500
2000 25002500
2500
SpeedSpeed (r/min)
Speed(r/min)
Speed (r/min)
(r/min) Speed
Speed(r/min)
Speed(r/min)
Speed (r/min)
(r/min)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 75
End-ported
Models

PVM018/020

Dimensions in millimeters (inches)


Alt. drain port “F.” (See options on page 107.)
Drain port “F” (See options on page 107.)
E Load sense port “J.” (See options on page 107.)
See shaft options starting on page 102.

72,0 58,0
(2.83) (2.28)

72,0 58,0 76,0


(2.28) 73,0
(2.83) (2.87) (2.99)

F
Control position for right hand
(cloc kwise) s haft rotation, as
viewed from shaft end. Position Adjustable maximum displacement
for left hand rotation is shown on G (with adj. max. stop) stop (1 turn = 1.1 cm3/rev). CCW
following page. reduces displacement.
H (without adj. max. stop) 37,4
(1.47)

165,7
(6.52)

85,1
(3.35)
B Inlet gauge
port “K.”
See options
55,2 on page 107.
(2.17)
23,0 Inlet port “B.”
(.91) See options
on page 106.
D ∅A J 34,5 34,0
C (1.36) (1.34)
Drain port
M M K “F.” See
Outlet port “C.”
options on
L See options on page 106.
page 107.

76 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models

PVM018/020

Dimensions in millimeters (inches)


Dimensions in millimeters (inches)

37,4
(1.47)
37,4
(1.47)

Control position for right hand


Adjustable maximum displacement rotation position
Control for rightcontrol
(Load sensing hand
stop (1 turnmaximum
Adjustable /rev). CCW
= 1.1 cm3displacement rotation
shown) (Load sensing control
reduces
stop displacement.
(1 turn = 1.1 cm3/rev). CCW shown)
reduces displacement.
165,7
(6.52)
165,7
Inlet position for right hand rotation (Position (6.52)
Inlet position
for left for rightshown
hand rotation hand rotation
below). (Position
for left hand rotation shown below). Outlet
Outlet

34,5 34,0
(1.36)
34,5 (1.34)
34,0
(1.36) (1.34)
Inlet/Outlet Ports and Control
Inlet/Outlet
Positioned Ri gh t and
for Ports HandControl
Rotation
Positioned for Ri gh t Hand Rotation

Control position for left hand


rotation position
Control (Pressure left hand
forcompensated 37,5
(1.48)
37,5
rotation
control shown)
(Pressure compensated (1.48)
control shown)

140,5
(5.53)
140,5
(5.53)126,3
(4.97)
126,3
(4.97)

Inlet position for left hand


rotation
Inlet for left
(Position
position forhand
right
rotation
hand rotation shown
(Position above)
for right
hand rotation shown above)
Outlet
Outlet

Inlet/Outlet Ports and Control


Inlet/Outlet
Positioned Left Hand
forPorts and Rotation
Control
Positioned for Left Hand Rotation

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 77
Side-ported
Models

PVM018/020

Dimensions in millimeters (inches)


Load sense port “J”
(See options on page 107) M
Outlet port “C.”
Alt. drain port “F” E CL outlet See options on page 106.
(See options on page 107) port “C.”
Drain port “F”
(See options on page 107)

See shaft options starting


on page 102.
72,0 M
(2.83) To pilot
mtg. flg.
N

72,0 58,0
(2.83) (2.28)
Adjustable maximum displacement
stop (1 turn = 1.1 cm3/rev). CCW
reduces displacement.
F Outlet port “C” (above).
See options on page 106.
Control position for right hand
(clockwise) shaft rotation , as viewed Inlet port “B.”
from shaft end. Position for left hand G (with adj. max. stop) See options on page 106.
rotation is shown on following page.
H (without adj. max. stop) 114,7
(4.52)

108,8
(4.28)
85,1
(3.35)
B
Outlet
gauge
55,2 port “K.”
(2.17) See
∅A 23,0
Inlet gauge options
(.91) on page 107.
port “K.”
D Alt. drain J See options 21,9 21,6
C port “F.” See on page 107. (.86) (.85)
K
options on 62,9 62,9
M M page 107. L (2.48) (2.48)

78 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models

PVM018/020

Dimensions
Dimensionsininmillimeters
millimeters(inches)
(inches)
114,7
114,7
Adjustable
Adjustablemaximum
maximumdisplacement
displacement (4.52)
(4.52)
stop
stop(1(1turn
turn= =1.1
1.1cm3/rev).
cm CCW
3/rev). CCW Control positionforforright
Controlposition righthand
hand
reduces
reducesdisplacement.
displacement. rotation
rotation(Load
(Loadsensing
sensingcontrol
control
shown)
shown)

Inlet positionforforright
Inletposition righthand
handr otation
r otation(Position
(Position
forforleft
lefthand
handrotation
rotationshownshownbelow)
below) Outlet
Outletgauge
gaugeport
port“K.”
“K.”
See
Seeoptions
optionsononpage
page107 . .
107

Outlet
Outlet
Inlet
Inletgauge
gaugeport
port“K.”
“K.”See
See
options
optionsononpage
page107 . .
107

21,9
21,9 21,6
21,6
(.86)
(.86) (.85)
(.85)
62,9
62,9 62,9
62,9
(2.48)
(2.48) (2.48)
(2.48)

Inlet/Outlet
Inlet/OutletPorts
Portsand andControl
Control
Positioned forRiRighgh
Positionedfor t Hand
t HandRotation
Rotation

86,5
86,5
(3.41)
(3.41)
72,3
72,3
(2.85)
(2.85)
Control positionforforleft
Controlposition lefthand
handr otation
r otation
(Pressure
(Pressurecompensated
compensatedcontrol controlshown)
shown)

Outlet
Outletgauge
gaugeport
port“K.”
“K.”See
See Inlet
Inletgauge
gaugeport
port“K.”
“K.”
options
optionsononpage
page107
107. . Seep
Seepoptions
optionsononpage
page107
107. .

Inlet positionforforleft
Inletposition lefthand
hand
rotation
rotation(Position
(Positionforforright
right
hand
handrotation
rotationshown
shownabove)
above)
Outlet
Outlet

Inlet/Outlet
Inlet/OutletPorts
Portsand
andControl
Control
Positioned
PositionedforforLeft
LeftHand
HandRotation
Rotation

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 79
Thru-drive
Models

PVM018/020

Dimensions in millimeters (inches)


Load sense port “J” Centerline of
(See options on page 107) outlet port
164,2
Alt. drain port “F” (6.46)
124,0 Outlet port “C.”
(See options on page 107) (4.88) See options on page 106
Drain port “F”
(See options on page 107)

See shaft options starting


on page 107.
72,0
(2.83)
to pilot 164,2
mtg. flg. (6.46)

72,0 58,0
(2.83)(2.28)

Adjustable maximum displacement


stop (1 turn = 1.1 cm3/rev). CCW
26,1 reduces displacement.
(1.03)
Control position for right hand Inlet port “B.”
(cloc kwise) s haft rotation, as viewed 221,4 (8.72) See options
from shaft end. Position for left hand with adj. max. stop on page 106.
rotation is shown on following page. 212,3 (8.36) 114,7
without adj. max. stop (4.52)

108,1
(4.14)
∅A 85,1
(3.35) 23,0
B (.91)

60,0
(2.36)

99,0
D (3.90)
C 167,7 62,9 64,2
(6.60) (2.48) (2.53)
M M 223,2 Alt. drain port “F.”
(8.79) See options on page 107.

80 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive Model Code Position 25
Description

Models A For SAE “A” pad with a 9T, 16/32 DP, 30° pressure angle,
involute spline
B For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle,
involute spline
G For ISO 80 A2HW pad with a 9T SAE spline
PVM018/020 H For ISO 80 A2HW pad with a 11T SAE spline

Dimensions in millimeters (inches) 114,7


(4.52)
Adjustable maximum displacement stop
(1 turn = 1.1 cm3/rev). CCW reduces Control position for right hand
displacement. rotation (Load sensing control
shown)
Inlet position for right hand
rotation (Position for left hand
rotation shown below)
Outlet

Inlet/Outlet Ports and Control


Positioned for Right Hand Rotation
62,9 64,2
(2.48) (2.53)

Control position for left hand rotation


(Pressure compensator control shown)
86,5
Output shaft 21T, 32/64 DP, (3.41)
30° PA involute spline. 72,3
57,49 (2.85)
(2.26)
40,46 12,25
(1.59) (0.48)
∅27,00
(1.06)
79,4
(3.13) K (2 places)

Inlet position for left hand


∅G rotation (Position for right
53,5 hand rotation shown above)
(2.11)
Outlet
89,70 (3.531) Inlet/Outlet Ports and Control
∅ 89,60 (3.527) Positioned for Left Hand Rotation
H H
159,2 2,00 (0.079)
(6.27) 1,90 (0.075)
8,50
(0.33) N (2 places)

20,0 20,0
(0.79) (0.79)

Model Code Position 25 ØG H K N


A,B 82,625 (3.253) 375-16 UNC-2B thd. 375-16 UNC-2B thd.
53,2 (2.09)
82,575 (3.251) 0.75 deep min 0.62 deep min.
G,H 80,046 (3.151) M10 x 1,50 thd. M10 x 1,50 thd.
54,5 (2.15)
80,002 (3.150) 19,05 deep min 15,88 deep min.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 81
Flange
Designations

PVM018/020

“A” Pilot Flange


Designation ØA B C D E F G H J K L M
SAE J744-82-2 82,55 11,35/10,97 106,4 53,2
Model Code A (3.25) (.447/.432) (4.19) (2.09) 131,5 33,6 228,9 219,8 106,5 166,7 200,7 65,2
ISO 3019/2-80A2HW 80,00 11,27/11,00 109,0 54,5 (5.18) (1.32) (9.00) (8.65) (4.19) (6.56) (7.90) (2.57)
Model Code B (3.15) (.444/.433) (4.29) (2.15)
“B” Pilot Flange
Designation
SAE J744-101-2 101,60 14,55/14,17 146,0 73,0
Model Code C (4.00) (.572/.557) (5.750) (2.875) 124,0 26,1 221,4 212,3 99,0 159,2 193,9 87,0
ISO 3019/2-100A2HW 100,00 14,27/14,00 140,0 70,0 (4.88) (1.03) (8.72) (8.36) (3.90) (6.27) (7.63) (3.43)
Model Code D (3.937) (.562/.551) (5.512) (2.756)

Pilot Flange Designation ØA B C D


SAE J744-127-2 Model Code C 101,60 (4.00) 14,55/14,17 (.572/.558) 146,0 (5.75) 73,0 (2.87)
ISO 3019/2-100 A2HW Model Code D 100,00 (3.94) 14,27/14,00 (.562/.551) 140,0 (5.51) 70,0 (2.76)

82 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models

PVM045/050

Dimensions in millimeters (inches)

Drain port “F.” See Alternate drain port “F”


See shaft options starting options on page 107.
on page 102. Inlet gauge port “K”

80,0 28,0 (1.10) 80,0


(3.15) (3.20)

80,0 Adjustable maximum


(3.15) 80,0 displacement stop
(3.20) (1 turn = 2 cm3/rev).

134,3 (5.29) max.


36,9 (1.45)

Control position for left hand (countercloc kwise) Load sensing control
shaft rotation , as viewed from shaft end. (See pressure compensated
Position for right hand rotation is shown on control on following page.)
following page.
Load sense port “J.” See
Alternate load 257,0 (10.12) max. options on page 107.
sense port “J”
247,0 (9.72) Inlet port “B.” See
44,6 (1.75) 19,1 options on page 106.
178,6 (7.03)
(0.75)
B

E 130,6
(5.14)

42,0
(1.65)

∅A
D 135,4 (5.33) 53,0
47,8 (1.88) (2.09)
C 175,0 (6.89) 75,1 87,1
87,0 Alternate (3.43)
212,0 (8.350) (2.96)
(3.425) drain
port “F” Outlet port “C.” See
Outlet gauge port “K.” See options on page 106.
174,0 (6.85) options on page 107.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 83
End-ported
Models

PVM045/050

Dimensions in millimeters (inches)

Dimensions in millimeters (inches)


34,4 (1.35) 121,8 (4.80) max.
98,9 (1.35)
34,4 (3.89) 121,8 (4.80) max.
4,0 (0.16) Control position for right hand
98,9 (3.89) rotation (Pressure compensated
Control position for
4,0 (0.16) control position for right hand
Controlshown)
left hand rotation rotation (Pressure compensated
Control position for control shown)
left hand adjustment
Non-maximum rotation 138,5
stop control cap. See (5.45)
preceding
Non-maximum pageadjustment
for adjustable 138,5
maximum
stop control displacement
cap. See stop (5.45)
preceding page for adjustable
Inlet position
maximum right hand
fordisplacement stop Outlet
rotation (Position for left
hand rotation for
Inlet position rightbelow)
shown hand Outlet
rotation (Position for left
hand rotation shown below) 53,0 47,8 (1.88)
(2.09)
87,1 75,1
53,0 (3.43) (2.96) 47,8 (1.88)
(2.09)
87,1 75,1
(3.43)and Control
Inlet/Outlet Ports (2.96) Positioned
for Ri gh t Hand Rotation
Inlet/Outlet Ports and Control Positioned
for Ri gh t Hand Rotation

Control position for left Control position for


hand rotation (Load right hand rotation
sensing for left
control shown)
Control position Control position for
hand rotation (Load right hand rotation
sensing control shown)

Inlet position for left hand


Outlet
rotation (Position for right
hand rotation for
Inlet position left hand
shown above)
Outlet
rotation (Position for right
Inlet/Outlet Ports and Control Positionedhand rotation shown above)
for Left Hand Rotation
Dimensions
Inlet/Outlet shown
Ports onControl
and preceding page.
Positioned
for Left Hand Rotation
Dimensions shown on preceding page.

84 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models

PVM045/050

Dimensions in millimeters (inches)

Adjustable max. Drain port “F.” See Inlet gauge


displacement options on page 107. port “K”
stop (1 turn = 2 See shaft Outlet gauge
81,3 cm3/rev) 36,9 options starting port “K.”
(3.20) (1.45) on page 102. See option
on page 107.

134.3 57,50 (2.26) 50,0 (1.97)


(5.29)
max. 72,5 (2.85) 69,0 (2.72)
81,3
(3.20) View Z-Z

Load sensing control (See pressure compensated


control on following page.) Load sense port
“J.” See options Control position for right hand
Alternate load sense port “J” on page 107. (cloc kwise) s haft rotation, as viewed
257,0 from shaft end. Position for left hand
(10.12)
max. rotation is shown on following page.
247,0 (9.72) 44,6 (1.75)
178,6
(7.03) 19,1 (0.75)
117,6 Z
72,1 B
168,2 (2.84) (4.63)
(6.62) 130,6 E
109,1 (5.14)
(4.30)
75,5 (2.97)

42.0
(1.65) ∅A Z
78,0 D
183,0 135,4 42.0
(7.20) (3.07) C (5.33) (1.65)
208,0 (8.19) 87,0
230,0 (3.425) 191,6 (7.54)
(9.06)
Alternate drain 174,0 (6.850) Alternate drain port “F”
Outlet port “C.”
See options port “F”
Inlet port “B.” See
on page 106. options on page 106.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 85
Side-ported
Models

PVM045/050

Dimensions in millimeters (inches)


Dimensions in millimeters (inches)

121,8 (4.80) max. 34,4 (1.35)


121,8 (4.80) max. 34,4 (1.35)
Control position for left hand 98,9 (3.89)
Control position for left hand 98,9 (3.89) Control position for right hand rotation
rotation (Pressure compensated 4,0 (0.16) Control position for right hand rotation
rotation (Pressure compensated 4,0 (0.16) (Inlet/outlet port positions for right hand
control shown). Inlet/outlet port (Inlet/outlet port positions for right hand
control shown). Inlet/outlet port rotation are shown on preceding page.)
positions for left hand rotation rotation are shown on preceding page.)
positions for left hand rotation
are the opposite of those shown Non-maximum adjustment stop control
are the opposite of those shown Non-maximum adjustment stop control
for right hand rotation on 138,5 cap. See preceding page for adjustable
for right hand rotation on 138,5 cap. See preceding page for adjustable
preceding page. (5.45) maximum displacement stop.
preceding page. (5.45) maximum displacement stop.
Outlet gauge port
Outlet gauge port
“K.” See options Inlet gauge
“K.” See options Inlet gauge
on page 107. port “K”
on page 107. port “K”
57,50 (2.26) 50,0 (1.97)
57,50 (2.26) 50,0 (1.97)
72,5 (2.85) 69,0 (2.72)
72,5 (2.85) 69,0 (2.72)
Inlet/Outlet Ports and Control Positioned
Inlet/Outlet
forPorts and Control
Lef t Hand RotationPositioned
for Lef t Hand Rotation

Control position for left hand rotation


Control position for left hand rotation
(Inlet/outlet port positions for left hand
(Inlet/outlet port positions for left hand
rotation are the opposite of those
rotation are the opposite of those Control position for right hand rotation
shown for right hand rotation on
shown for right hand rotation on Control position for right hand rotation
preceding page.) (Load sensing control shown). Inlet/outlet
preceding page.) (Load sensing control shown). Inlet/outlet
port positions for right hand rotation are
port positions for right hand rotation are
shown on preceding page.
shown on preceding page.

Inlet gauge Outlet gauge port “K.” See


Inlet gauge Outlet gauge port “K.” See
port “K” options on page 107.
port “K” options on page 107.

Inlet/Outlet Ports and Control Positioned


Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
for Right Hand Rotation
Dimensions shown on preceding page.
Dimensions shown on preceding page.

86 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models

PVM045/050

Dimensions in millimeters (inches) Alt. drain port


“F.” See options
121,8 34,4
on page 107. (4.80) (1.35)
See shaft options starting
on page 102. 197,7 98,9 Control position
(7.78) (3.89) for R.H. rotation

135,8
(5.35)
Outlet 138,5
port “C.” (5.45)
See 81,3
options 68,8
(3.20) (2.71)
on
page 106.
183,0 81,3 72,3
(7.20) (3.20) (2.85)
208,0
(8.19)
Drain port “F.” See options Control position
View “A-A” on page 107. for L.H. rotation
36,9
(1.45) Left Hand Rotation
Flange
dependent
133,3 34,1 Adjustable maximum displacement stop
(5.25) (1.34) (1 turn = 2.1 cm3/rev)
110,8 Load sense port “J.”
(4.36) See options on 249,0 Load sense Load sense
44,6 (9.80)
(1.76) page 107. control position control position
178,6 for L.H. rotation
(7.03) for R.H. rotation
11,0
(0.43)
168,2
(6.62)
130,6 117,6
(5.14) (4.63)
A
D
∅A
78,6 42,0 (1.65)
(3.09)
A
Inlet port “B.”
B Drain port “F.” Ri ght Han d Rotation
See options on
See options on 191,6 page 106. 5,4
(7.54) Outlet gauge
C page 107. (0.21) port “K”
42,0
87,0 87,0 251,0 (1.65)
(3.43) (3.43) (9.88)

Ri gh t Hand Rotation with Load Sensing Control and Tube Ports Inlet gauge port “K.”
See options on page 107.
35,0 36,0
(1.38) (1.42)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 87
Thru-drive
Models

PVM045/050

Dimensions in millimeters (inches) Model Code Position 25


Description
“A” Pad 61,74
(2.43) A For SAE “A” pad with a 9T,
40,4 16/32 DP, 30° pressure
(1.59) angle, involute spline
12,24 B For SAE “A” pad with a 11T,
(0.482) 16/32 DP, 30° pressure
angle, involute spline
C For SAE “B” pad with a 13T,
89,70 (3.531) 16/32 DP, 30° pressure
∅G ∅ 89,60 (3.527) angle, involute spline
D For SAE “B” pad with a 15T,
16/32 DP, 30° pressure
angle, involute spline
∅ 31,75 N (2 places) G For ISO 80-A2HW pad
(1.25) with a 9T SAE spline
H For ISO 80-A2HW pad
Output shaft 26T, 32/64 DP, with a 11T SAE spline
30° PA involute spline. H H J For ISO 100-A2/B4HW pad
with a 13T SAE spline
“B” Pad 263,5
(10.37)
Output shaft 26T, 32/64 DP,
30° PA involute spline.
53,0 53,0
276,0 (2.09) (2.09)
(10.87) L (4 places)
K (2 places)
86,49
(3.41) 10,28 J (2 places)
(0.40)

J (2 places)
86,0
(3.39)
2 plcs
∅G
107,90 (4.248) K (2 places)
∅ 107,82 (4.244)
86,0 N (2 places)
(3.39)
2 plcs
∅ 35,30
2,00 (0.079) (1.39) M (4 places)
1,90 (0.075) H H
11,75
77,47 (0.46)
(3.05)

Model Code Position 25 ØG H J K L M N


A,B 82,58 (3.251) 53.2 – .375-16 UNC-2B
– – –
82,52 (3.249) (2.09) thd. 0.60 deep min.
G,H 80,046 (3.15) 54,5 – M10 thd. x 1,50
– – –
80,002 (3.149) (2.15) 15,0 deep min.
89,8 .500-13 UNC-2B thd. .500-13 UNC-2B .500-13 UNC-2B
101,65 (4.002) 73,0 44,9
C,D 24.9 deep min. M12 x thd. thru M10 x thd. thru
101,60 (4.00) (2.87) (1.77) (3.54)
1,50 thd. 24,9 deep min. 1,50 thd. thru M12 x 1,50 thd. thru
J,K 100,0 (3.937) 70,0 44,2 88,38 M12 thd. x 1,50 thd. M10 x 1,50 thd. M12 x 1,50 thd.
99,946 (3.935) (2.76) (1.74) (3.48) 24,9 deep min. thru thru

88 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Flange
Designations

PVM045/050

Pilot Flange Designation ØA B C D E


101,60/101,55 9,70/9,19 14,55/14,17
SAE
J744-101-2 (4.000/3.998) 146,0 (5.750)
(.382/.362) 73,0 (2.875) (.572/.557)
100,00/99,95 9,50/9,00 14,27/14,00
ISO
3019/2-100A2HW (3.937/3.935) 140,0 (5.512)
(.374/.354) 70,0 (2.756) (.562/.551)

Pilot Flange Designation ØA B C D


SAE 2-bolt mount 101,60/101,55 (4.000/3.998) 73,0 (2.87) 146,0 (5.750) 14,55/14,17 (.572/.557)
ISO 100 2-bolt mount 100,00/99,95 (3.937/3.935) 70,0 (2.76) 140,0 (5.512) 14,27/14,00 (.562/.551)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 89
End-ported
Models

PVM057/063

Dimensions in millimeters (inches)


See mounting flange options on page 101.
269,7
See shaft options starting on page 102. (10.62)
w/o adj. max. stop

206,2
(8.12)
116,0 82,3
(4.57) (3.24)

82,3
(3.24)

Outlet port “C.” See 32,9 157,0


options on page 106. Inlet port “B.” (1.30) (6.18)
See options on
page 106.
168,2
Left Hand Rotation, Tube Port (6.62)
with Pressure Compensator
274,8
SAE .500-13 Inlet port “B.” See options (10.82)
UNC-2B thd. 1.06 on page 106. 292,2 w/adj. max. stop
deep min. 254,3 (11.50)
ISO M12 x 1,75 thd. (10,0) Load sense port “J.”
29.0 deep min. 165,6 See options on
(6.52)
page 107.
Outlet port
“C.” See
121,8 38,89 options on
(4.80) (1.53) page 106. 39,0
87,0 (1.54)
(3.43)
199,3
(7.85) 52,38
(2.06)
Outlet gauge port “K.”
77,5 26,19
(3.05) Inlet gauge port “K” on
(1.03) opposite side. See
options on page 107.
SAE .375-16
77,78 UNC-2B thd. .88
(3.06) 21,44 13,1 102,8
(.84) deep min. ISO M10 x 1,5 thd.
(.51) 23.0 deep min. (4.05)
42,88 201,4
(1.69) (7.93)
26,18
88,7 75,7 (1.03) 245,4
(3.49) (2.98) Drain port “F.” (9.66)
Ri gh t Hand Rotation , Alternate drain port “F” on
Flange Port with Load Sensing Control opposite side. See options on page 107.

90 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models

PVM057/063

Dimensions in millimeters (inches)


See mounting flange options on page 101.
See shaft options starting on page 102.

269,7
(10.62)
198,1 w/o adj. max. stop
(7.80)
116,0
(4.57) 82,3
(3.24)

82,3
Outlet gauge port Inlet gauge port “K.” (3.24)
“K.” See options See options 157,0
on page 107. on page 107. (6.18)

32,9
(1.30)
Left Hand Rotation with 168,2
Pressure Compensator (6.62)
274,8
(10.82)

Load sense port “J.” See 292,2


options on page 107. (11.50)
266,5 w/adj. max. stop
247,9 (10.49)
Adjustable maximum (9.76) 241,5
Outlet port (9.51)
displacement stop Inlet port “B.”
165,6 “C.” See 213,4
1 turn = 2.98 l/min See options on
(6.52) options on (8.40)
(0.79 USgpm) page 106. page 106.

38,89 121,8
(1.53) (4.80) 87,0 39,0
199,3 (3.43) (1.54)
(7.85)
77,78
(3.06)
77,5
(3.05) 26,2
(1.03)
21,44 52,37
SAE .500-13 (2.06) 13,1
(.84) UNC-2B thd. (.51)
61,5 57,0 SAE .375-16
42,88 1.06 deep min. (2.42) (2.24) 102,8
224,4 (1.69) UNC-2B thd. .88 26,19 (4.05)
(8.83) ISO M12 1,75 75,0 75,0 (1.03)
deep min.
To mounting face thd. 29.0 deep (2.95) (2.95) ISO M10 x 1,5 thd.
min. 23.0 deep min.
Ri gh t Hand Rotation with Drain port “F.” Alternate drain port “F” on
Load Sensing Control opposite side. See options on page 107.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 91
Thru-drive
Models

PVM057/063

Dimensions in millimeters (inches)


See pilot flange options on page 101.
See shaft options starting on page 102. 80,1
(3.15)
44,8
(1.76)
Alternate drain port “F”
205,0
(8.07) S (See table
116,0 next page)
(4.57) 82,3
(3.24)

82,3
(3.24)
T1 (2 places) 157,0
(6.18)
32,9
(1.30)
M12 thd. 21,0 deep
(4 places)
∅R 168,2
(6.62)
Left Hand Rotation with Pressure Compensator
and SAE 2-bolt “A” Flange (no adapter)
Load sense port “J.” See
SAE .500-13 options on page 107.
UNC-2B thd. 254,6 292,2
1.06 deep min. (10,0) Outlet (11.5)
284,4
ISO M12 x 1,75 thd. port “C.” (11.2)
29.0 deep min. Inlet port “B.” See options 213,4
165,6
See options (6.52) on page 106. (8.40)
on page 106.

121,8 39,0
(4.80) 87,0 (1.54)
199,3 (3.43)
(7.85)
77,78
(3.06)
77,5
(3.05) 52,37
38,89 (2.06)
21,44 (1.53) 26,18 13,1
(.84) (1.03) (.52)
12,0 14,0 102,8
42,88 Inlet gauge port (.47) (.55) Outlet gauge port 26,2 (4.05)
224,4 (1.69) “K.” See options “K.” See options (1.03)
89,0 92,0 Drain port “F.” Alternate drain
(8.83) on page 107. (3.50) (3.62) on page 107. SAE .375-16 port “F” on opposite side.
To mounting face UNC-2B thd. .88 See options on page 107.
deep min.
Ri gh t Hand Rotation with Load Sensing Control
ISO M10 x 1,5 thd.
and SAE 2-bolt “A” Flange (no adapter)
23.0 deep min.

92 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models

PVM057/063

Coupling Length Code


Dimensions in millimeters (inches)
68,7 SAE “A,” 9T 62,5 (2.46) A,G
(2.70) “S” SAE “B,” 13T 93,0 (3.66) C,J
SAE “B-B,” 15T 93,0 (3.66) D,K
SAE “C,” 14T 93,0 (3.66) E,L

Coupling (see table) Model Code Position 25


Description
A SAE “A,” 9T, 16/32 DP,
30° pressure angle,
involute spline
Coupling length C SAE “B,” 13T, 16/32 DP,
30° pressure angle,
(see table) involute spline
D SAE “B-B,” 15T, 16/32 DP,
“B” Adapter Flange 30° pressure angle,
To mounting face involute spline
309,9 E SAE “C,” 14T, 12/24 DP,
(12.20) 30° pressure angle,
involute spline
G For ISO 80-A2HW pad
“T1” with a 9T SAE spline
J For ISO 100-A2/B4HW pad
with a 13T SAE spline
K For ISO 100-A2/B4HW pad
with a 15T SAE spline
35,0 L For ISO 125-A2/B4HW pad
(1.38) with a 14T SAE spline
“T2”
(4 plcs)

“V” Support
mounting point
297,4 (4 plcs) 92,0
∅“R”
(11.70) (3.62)
To mounting face Right hand rotation with Load Sensing Control and
SAE 2-/4-bolt “B” adapter flange

Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Points
Flange Bolt “R” “S” “T1” “T2” “V”
A,B SAE “A” 2-bolt SAE Ø82,65 (3.25±.001) 8,6/8,1 (.32/.34) .375-16 UNC-2B thd. N/A N/A
G,H ISO 80 ISO Ø80,05 (3.15) 9,0/8,0 (.35/.31) M10 thd. N/A N/A
C,D SAE “B” 2-/4-bolt SAE Ø101,65 (4.002±.001) 12,5/11,5 (.49/.45) .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B thd. .98” deep
J,K ISO 100 ISO Ø100,05 (3.94) 12,5/11,5 (.49/.45) M12 thd. M12 thd. M12 thd. x 25,0 deep

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 93
Thru-drive
Models

PVM057/063

Dimensions in millimeters (inches)


“C” Adapter Flange

To mtg, face
297,4 92,0
(11.70) ∅ “R”
(3.62)

“W” (4 plcs) 107,0


(4.21)

35,0
(1.38)
(4 plcs)

“T2”

“T1”
309,9
(12.20)
To mtg. face Left hand rotation with Pressure Compensator and
SAE 2-/4-bolt “C” Adapter Flange


Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Points
Flange Bolt “R” “S” “T1” “T2” “V”
E,F SAE “C” 2-/4-bolt SAE Ø127,05 (5.002±.001) 15,5/14,5 (.61/.57) .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B thd. .98” deep
L,M ISO 125 ISO Ø125,05 (4.92) 15,5/14,5 (.61/.57) M16 thd. M12 thd. M12 thd. x 25,0 deep

94 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models

PVM074/081

*Right Hand Only

Dimensions in millimeters (inches)

See pilot flange options on page 101. Lifting point .375-16 UNC thd.
See shaft options starting on page 102. 10,0 (.39) deep with SAE drain
M10 thd. 10,0 (.39) deep with ISO drain

Alt. drain port "F". See


102,0 options on page 107.
Alt. drain port "F". See
(4.02)
options on page 107.

Inlet port "B". 87,0


Outlet port 2X
See options (3.42)
"C". See
options on page 106.
on page 106.

Outlet gauge port Inlet gauge port


"K". See options "K". See options
on page 107. on page 107. 33,9
Left hand rotation (1.33)
113,6
with Pressure Compensator (4.47)
319,1 w/o max adj stop
(12.56)
334,8
Max. Adj. stop. One rotation will change (13.18)
Inlet port "B". See displacement 6,1-6,8 l/min
options on page 106. (1.6-1.8 USgpm) at 1800 rpm 194,8
( 7.67)
143,3 Load sense port "J". 146,1
TO MOUNTING FACE
(5.64) See options on page 107. ( 5.75)
249,6 4,3
(9.83) Inlet gauge (.17) C/G location
port "K".
See options
on page 107.
Outlet 110,0
86,0 gauge (4.33) 33,0
(3.39) port "K". (1.30)
See options
on page 107.
16,8
86,0 (.66)
(3.39)
Outlet port
"C". See
options on
65,0 65,0 page 106.
Alt. drain port "F". 181,6
(2.56) (2.56)
(7.15)
See options on page 107. Drain port
92,0 91,0 "F". See 246,6
(3.62) (3.58) options on (9.71)
page 107. 279,6
114,0 114,0
(4.49) (4.49) (11.01)

288,0
R ight hand rotation
(11.34)
with Load Sensing Control

PVM074/108 is not available with left hand rotation in any port configuration.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 95
Thru-drive
Models

PVM074/081
*Right-hand only

Dimensions in millimeters (inches)


Lifting point .375-16 UNC thd.
See pilot flange options on page 101. 10,0 (.39) deep with SAE drain
See shaft options starting on page 102. M10 thd. 10,0 (.39) deep with ISO drain

Alt. drain port "F". See


102,0 Alt. drain port "F". See options on page 107.
(4.02) options on page 107.

Outlet port "C". 87,0 2X


See options on Inlet port "B". (3.42)
page 106. See options
on page 106.

Outlet gauge port Inlet gauge port


"K". See options "K". See options
on page 107. on page 107.
Left hand rotation 33,9
113,6 (1.33)
with Pressure Compensator (4.47)
319,1 w/o max adj stop
(12.56)
Max. Adj. stop. One rotation will change 334,8
Inlet port "B". See
displacement 6,1-7,4 l/min (13.18)
options on page 106.
(1.7-1.9 USgpm) at 1800 rpm 194,8
Load sense port "J". (7.67)
TO MOUNTING FACE 143,3 See options on page 107. 146,1
249,6 4,08 (5.64) (5.75)
(9.83) (.16) C/G location

110,0
86,0 2X T1 Outlet gauge (4.33) 33,0
(3.39) port "K". (1.30)
See options
on page 107.
14.5
86,0 (0.57)
(3.39)
Outlet port "C".
See options on
"A2" 45,0 page 106.
Alt. drain port 181,6
(1.77)
"F". See options Inlet gauge (7.15)
on page 107. port "K". 92,0 91,0 246,6
See options (3.62) (3.58) Drain port "F". (9.71)
See options 277,6
on page 107. 114,0 114,0
on page 107. (10.93)
(4.49) (4.49) 322.6
R ight hand rotation (12.70)
with Load Sensing Control
and 2-bolt“A” flange

PVM074/108 is not available with left hand rotation in any port configuration.

96 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models

PVM074/081
*Right-hand only

Coupling Length
Dimensions in millimeters (inches)
68,3 Code
(2.69) SAE “A,” 9T 64,5 (2.54) A,G
“S” 43,3 SAE “A,” 11T 65,3 (2.57) B,H
(1.70) “S” SAE “B,” 13T 95,3 (3.75) C,J
SAE “B-B,” 15T 95,3 (3.75) D,K
SAE “C,” 14T 95,3 (3.75) E,L
“R3” SAE “C-C,” 17T 91,8 (3.61) F,M
“R3”
“R1” “R2" “R1” “R2”

Coupling (see table) Model code Position 25


Coupling (see table) Description
Coupling length
Coupling length 25,0 (.98) A SAE “A,” 9T, 16/32 DP,
(see table) 30° pressure angle,
(See table)
involute spline
With adapter plate Without adapter plate B SAE “A,” 11T, 16/32 DP,
30° pressure angle,
involute spline
C SAE “B,” 13T, 16/32 DP,
“B” Adapter Flange 30° pressure angle,
involute spline
To mtg, face 372,6 D SAE “B-B,” 15T, 16/32 DP,
(14.68) 30° pressure angle,
involute spline
E SAE “C,” 14T, 12/24 DP,
30° pressure angle,
involute spline
4X F SAE “C-C,” 17T, 12/24 DP,
35,0 30° pressure angle,
(1.38) involute spline
“A1”
G For ISO 80-A2HW pad
with a 9T SAE spline
H For ISO 80-A2HW pad
with a 11 T SAE spline
92,0 “T1”
(3.62) J For ISO 100-A2/B4HW pad
with a 13T SAE spline
K For ISO 100-A2/B4HW pad
4X “W” “T2” with a 15T SAE spline
“A1” L For ISO 125-A2/B4HW pad
To mtg, face 335,1 with a 14T SAE spline
(13.19) “A2” M For ISO 125-A2/B4HW pad
View rotated 90° with a 17T SAE spline
Right hand rotation with Load Sensing Control
and ISO or SAE 2-/4-bolt “B” adapter flange

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
A,B SAE “A” SAE Ø82,6 Ø89,65 2,00 (.08) 9,0/8,0 375-16 UNC-2B thd. N/A N/A N/A 53,2
G,H 2-bolt (3.25) (3.53) 1,90 (.07) (.35/.31)
ISO 80 ISO Ø80,05 Ø89,75 2,70 (.11) 9,0/8,0 M10 thd. N/A N/A N/A 54,5
(3.15) (3.53) 2,60 (.10) (.35/.31) (2.15)
C,D SAE “B” SAE Ø101,65 Ø108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0
J,K 2-/4-bolt (4.00) (4.25) 1,90 (.07) (.49/.45) thd. .98” deep (1.77) (2.87)
ISO 100 ISO Ø100,05 Ø108,75 2,70 (.11) 12,5/11,5 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0
(3.94) (4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 97
Thru-drive
Models

PVM074/081
*Right-hand only

Dimensions in millimeters (inches)


“C” Adapter Flange

To mtg, face 347,6


(13.69)

4X 35,0
(1.38)

“A1”
“T1” 92,0
(3.62)
4X “W”

“T2”
To mtg, face 335,1 “A1”
(13.19)
“A2”
View rotated 90ϒ
Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” Adapter Flange

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
E,F SAE “C” SAE Ø127,05 Ø133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5
L,M 2-/4-bolt thd. .98” deep (2.25) (3.56)
ISO 125 ISO Ø125,05 Ø133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 25,0 deep 56,57 90,0
(4.92) (3.26) 2,60 (.10) (.61/.57) (2.23) (3.54)

98 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models

PVM098/106

Dimensions in millimeters (inches) Alt. drain port “F”. See options on page 107.

See pilot flange options on page 101. Lifting point .375-16 UNC thd.10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 102.
Alt. drain port “F”. See
options on page 107.
121,0
(4.76)

2X 95,0
(3.74)

Inlet port “B”.


Outlet port See options
“C”. See options on page 106.
on page 106.
162,0
(6.38)
Outlet gauge port Inlet gauge
“K”. See options port “K”. See 33,9
on page 107. options on (1.33)
115,5
page 107.
Left hand rotation (4.55)
with Pressure Compensator w/o max adj stop
342,4
(13.48)
357,8
(14.09)

Max. Adj. stop. One rotation will


Inlet port “B”. See
change displacement 7,9-8,7 l/min
options on page 106. 214,6
(2.1-2.3 USgpm) at 1800 rpm Load sense port “J”.
To mounting face (8.45)
170,6 See options on page 107. 155,7
276,9 Inlet gauge
(10.90) 16,4 (6.72) (6.13)
port “K”. (.65) C/G location
See options
on page 107.

107,5 37,0
92,5 Outlet gauge (1.46)
port “K”. See (4.23)
(3.64)
options on
page 107.
35,5
90,0 (1.40)
(3.54) Outlet port “C”. See
options on page 106.

Alt. drain port 70,0 70,0 2X 194,5


“F”. See options (2.76) (2.76) (7.66)
266,9
on page 107. 98,0 91,0 Drain port “F”. See (10.51)
(3.86) (3.58) options on page 107. 305,6
119,0 119,0 (12.03)
(4.69) (4.69) 322,6
(12.70)
Left hand rotation with Load Sensing Control

PVM098/106 is not available in left hand rotation with rear ports.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 99
Thru-drive
Models

PVM098/106

Dimensions in millimeters (inches) Alt. drain port "F". See options on page 107.
Lifting point .375-16 UNC thd. 10,0 (.39) deep with
See pilot flange options on page 101. SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 102. Alt. drain port "F". See
options on page 107.
347,9
(13.70)
121,0
(4.76)
2X 95,0
(3.74)

Outlet port Inlet port "B".


"C". See See options
options on on page 106. 162,0
page 106.
(6.38)

33,9
(1.33)
Outlet gauge port Inlet gauge port 115,5
"K". See options "K". See options (4.55)
on page 107. on page 104. w/o max adj stop
Left hand rotation 342,4
with Pressure Compensator (13.48)
357,8
(14.09)

Max. Adj. stop. One rotation will change


Inlet port "B". See Outlet gauge port "K".
displacement 7,9-8,7 l/min
options on page 106. See options on page 107. 214,6
(2.1-2.3 USgpm) at 1800 rpm
To mounting face (8.45)
276,9 170,6 Load sense port "J". 164,4
(10.90) 17,3 (6.72) See options on page 107. (6.47)
(0.68) C/G location
36,6
2X T1
(1.44)
2X
150,0
37,0
(5.91) 107,5
92,5 (1.46)
(4.23)
(3.64)

90,0
(3.54) 42,0
(1.65)
Outlet port "C".
Alt. drain port "F". See A2* 45,0 See options 2X 194,5
options on page 107. (1.77) on page 106. (7.66)
266,9
98,0 91,0 Drain port "F". (10.51)
Inlet gauge port "K". See (3.86) (3.58) See options
options on page 107. 119,0 119,0 on page 107.
(4.69) (4.69)
R ight hand rotation with 2-bolt “A” flange
and Load Sensing Control

PVM098/106 is not available in left hand rotation with rear ports.

100 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models

PVM098/106

Coupling Length
Dimensions in millimeters (inches) Code
68,3
SAE “A,” 9T 64,5 (2.54) A,G
(2.69)
“S” SAE “A,” 11T 65,3 (2.57) B,H
43,3
SAE “B,” 13T 95,3 (3.75) C,J
(1.70) “S”
SAE “B-B,” 15T 95,3 (3.75) D,K
SAE “C,” 14T 95,3 (3.75) E,L
“R3” SAE “C-C,” 17T 91,8 (3.61) F,M
“R3”

COMBINE WITH
“R1” “R2” “R1” “R2”

EXISTING GRAPHIC Coupling (see table)


Model code Position 25
Coupling (see table) Description
Coupling length
25,0 FOR THIS PAGE
Coupling length
(see table)
A SAE “A,” 9T, 16/32 DP,
(.98) 30° pressure angle,
(see table) involute spline
With adapter plate Without adapter plate B SAE “A,” 11T, 16/32 DP,
30° pressure angle,
involute spline
C SAE “B,” 13T, 16/32 DP,
“B”
“B” Adaptor
Adapter Flange
Flange 30° pressure angle,
involute spline
To mtg, face 372,6 D SAE “B-B,” 15T, 16/32 DP,
372,9
(14.68) 30° pressure angle,
To mtg, face (14.68) involute spline
E SAE “C,” 14T, 12/24 DP,
30° pressure angle,
involute spline
35,0 F SAE “C-C,” 17T, 12/24 DP,
(1.38) 30° pressure angle,
involute spline
(4 plcs)
4X 35,0
“A1” G For ISO 80-A2HW pad
(1.38) with a 9T SAE spline
“A1” H For ISO 80-A2HW pad
92,0 “T1” “T1” with a 11 T SAE spline
92,0 (3.62) J For ISO 100-A2/B4HW pad
(3.62)
4X “W” Support with a 13T SAE spline
mounting points “T2” “T2” K For ISO 100-A2/B4HW pad
360,4 “A1” with a 15T SAE spline
ToTomtg,
mtg,face
face 360,4
(14.19) “V” Support L For ISO 125-A2/B4HW pad
“A1” “A2”
(14.19) mounting with a 14T SAE spline
View Rotated 90° points (4 plcs) M For ISO 125-A2/B4HW pad
“A2”
Right hand rotation with Load Sensing Control
View Rotated 90° with a 17T SAE spline
Right hand rotation with “CV” compensation
and ISO or SAE 2-/4-bolt “B” adapter flange
Model Code Position 25 Pilot O-ring O-ring Pilot Support
Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
A,B SAE “A” SAE Ø82,6 Ø89,65 2,00 (.08) 9,0/8,0 375-16 UNC-2B N/A N/A N/A 53,2
G,H 2-bolt (3.25) (3.53) 1,90 (.07) (.35/.31) thd. 0.59 deep
ISO 80 ISO Ø80,05 Ø89,75 2,70 (.11) 9,0/8,0 M10 thd. N/A N/A N/A 54,5
(3.15) (3.53) 2,60 (.10) (.35/.31) x 18,0 deep (2.15)
C,D SAE “B” SAE Ø101,65 Ø108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0
J,K 2-/4-bolt (4.00) (4.25) 1,90 (.07) (.49/.45) thd. .98” deep (1.77) (2.87)
ISO 100 ISO Ø100,05 Ø108,75 2,70 (.11) 12,5/11,5 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0
(3.94) (4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 101
Thru-drive
Models

PVM098/106

Dimensions in millimeters (inches)


“C” Adapter Flange

To mtg, face 372,9


(14.68)

4X 35,0
(1.38)

“T1” “A1”
92,0
(3.62)
4X “W” Support
mounting points “T2”

To mtg, face 360,4 “A1”


(14.19) “A2”
View Rotated 90° Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” adapter flange

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
E,F SAE “C” SAE Ø127,05 Ø133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5
L,M 2-/4-bolt thd. .98” deep (2.25) (3.56)
ISO 125 ISO Ø125,05 Ø133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 25,0 deep 56,57 90,0
(4.92) (3.26) 2,60 (.10) (.61/.57) (2.23) (3.54)

102 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models

PVM131/141

Dimensions in millimeters (inches)


See pilot flange options on page 101.
See shaft options starting on page 102.

369,4 (14.54)
230,4 (9.07)
131,0
34,0 132,7 (5.16)
(1.34) (5.22) “B” inlet port

172,0
(6.77)
“C”
outlet
port
115,0
(4.53) “K” “K”
Outlet Inlet
gage gage
Optional drain port “F” Adjustable maximum stop option. port port
Torque locknut to 37-45 Nm (27-33 lb ft). Lef t hand rotation
One turn of screw wil change pump with Pressure Compensator
displacement 5,7 cm3/rev (0.35 in3/rev).
Turn CCW to destroke.

65,0 (2.56) 2 plcs. 55,0 (2.17) 2 plcs. “K” Inlet 132,7 (5.22)
gage port
110,5 (4.35) R.H.
143,5 (5.65) 346,1 (13.63) max. length 94,5 (3.72) L.H.
w/o max. adj. stop
111,5 “J” Load sense signal port
(4.39) 122,6 (4.83) 2 plcs.
2 plcs. 180,6 (7.11)
“F2”

“B” inlet
port

“B2” 4 plcs.

55,0
(2.17) 106,0 “K” Inlet “K” Outlet
(4.17) gage port gage port
25,0 “C” outlet
(0.98) 49,7 (1.95) port
“F3” 192,6 (7.58)
“F” drain port “C2” 4 plcs.
2 plcs.
Optional drain 64,0
port “F” 330,6 (13.02) (2.52)
Lifting point 104,2 91,5
.500-13 UNC-2B thd. (4.10) (3.60)
18,0 (.709) dp. 2 plcs.
Right hand rotation with
Load Sensing Control

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 103
Side-ported
Models

PVM131/141

Dimensions in millimeters (inches)


See pilot flange options on page 101.
See shaft options starting on page 102.
369,4 (14.54) 131,0
280,4 (11.04) CL outlet (5.16)
172,0 Inlet gage
(6.77) 230,4 (9.07) port
port “K”
34,0
(1.34)
132,7
(5.22) Inlet
341,1 (13.43) port “B”
gage port spotface
318,1 (12.52)
gage port spotface
“C” 280,4 115,0
outlet (11.04) (4.53)
port ref. Outlet gage port “K”

100,0 (3.94) Outlet port “C.”


Optional drain port “F”
Left hand rotation with
“C2”
4 plcs. Pressure Compensator
Adjustable maximum stop option.
Torque locknut to 37-45 Nm (27-33 lb ft).
View A - A Outlet port One turn of screw will change pump
displacement 5,7 cm3/rev (0.35 in3/rev) 132,7 (5.22)
110,5 (4.35) R.H.
55,0 (2.16) 2 plcs.
94,5 (3.72) L.H.
65,0 (2.56) 2 plcs. 346,1 (13.63) max. length
w/o max. adj. stop “J” Load sense signal port
111,5
(4.39) 122,6 Inlet gage
2 plcs. (4.82) port “K”
2 plcs. 180,6 (7.11)

143,5
(5.70) “F2”

55,0
(2.17) 106,0
(4.17) A
“F” drain port
70,0 Outlet gage
“F3” 192,6 (7.58) (2.76)
Lifting point 2 plcs. “B2” port “K”
Optional drain .500-13 UNC-2B thd. 4 plcs. 70,0
port “F” 298.6 (11.76) (2.76)
18.0 (.709) dp. 2 plcs.
95.0
Inlet port “B” (3.74)
R ight hand rotation with
Load Sensing Control

104 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models

PVM131/141

Dimensions in millimeters (inches)


See pilot flange options on page 101.
See shaft options starting on page 102.

131,0
347,1 (5.16)
(13.67) CL outlet
280,4
(11.04) port
230,4
(9.07)
34,0
(1.33) 132,7
172,0 (5.22)
(6.77)
Outlet port “C.” Inlet port “B.”
See coupling See options on See options on
code below page 106. page 106.
See output “Q2” See
shaft below table below
8,5 (.33) ∅ “Q” See table below
14,0 (.55) A9 Left Hand Rotation with Pressure Compensator
44,7 19,0 (.75) A11 and SAE 2-bolt “A” Flange (no adapter)
(1.76) 80,0
(3.15)
Drain port “F.” See options
Inlet port “B.” See Load sense port “J.” SAE .500-13 UNC-2B
on page 107.
369,4 options on page 106. See options on thd. 1.00 deep min. or
(14.54) page 107. ISO M12 x 27.0 deep min.
346,1 SAE port 116,1 (4.57)
(13.63)w/o max. ISO port 150,0 (5.91) Outlet port “C.”
143,5
(5.65) 122,6 adj. stop 180,6 See options on
(4.83) 111,5
(4.39) (7.11) page 106.

65,0 280,4
(2.56) 132,7 (11.04)
(5.22)
15,0
(.59) 55,0
(2.16)

55,0 106,0
(2.17) (4.17) 45,0
54,5
(2.15) (1.77)
11,5 313,6
173,0 (.45) 40,0 (12.35)
(6.81) Inlet gage (1.57)
port “K.” See Alt. drain port “F.” See
192,6 4,0 options on page 107.
(7.58) options on page 107. 100,0 95,0
(3.94) (3.74) (.16)
298,6 Outlet gage port “K.” See
305,6 (11.76) SAE .500-13 UNC-2B options on page 107.
(12.03) thd. 1.19 deep min. or
ISO M12 x 31.0 deep min. SAE port 116,1 (4.57)
Inlet gage port “K”
ISO port 150,0 (5.91)
Model Code Position 25 “Q1” Thru-drive Flange “Q2” 2-bolt Thread Right Hand Rotation with Load Sensing Control
A,B SAE J744-82-2 .375-16 UNC-2B and SAE 2-bolt “A” Flange (no adapter)
Ø82.625/82.575 bore thd. 0.80 deep
G,H ISO 3019/2-80A2
Ø80.075/80.25 bore M10 thd. x 18,0 deep

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 105
Thru-drive
Models

PVM131/141

Model Code Position 25


Dimensions in millimeters (inches)
Description
A For SAE “A” pad with a 9T, 16/32 DP, 30° pressure
69,7 (2.74) angle,
involute spline
B For SAE “A” pad with a 11T, 16/32 DP, 30° pressure
angle,
involute spline
O-ring (furnished) Output shaft 14T 12/24 DP external involute spline
C  SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute
spline
D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, invo-
lute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute
spline
F SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, invo-
lute spline
Coupling (See table) G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
14,0 (.55) M For ISO 125-A2/B4HW pad with a 17T SAE spline

“B” Adapter Flange

372,1 (14.65)

“R2” - 2 places

35,0 (1.38)
4 places “R3”
4 places

“R4” (4 plcs)

359,6 (14.16) ∅ “R1” 92,0 (3.62) 4 places

Right Hand Rotation with SAE 2-/4-Bolt “B”


Flange and ISO 100 Adapter Flange
Model Code
Position 25 “R1” Thru-drive Flange “R2” 2-bolt Thread “R3” 4-bolt Thread “R4” Support Mounting Points

C,D SAE J744-101-2 & -4 .500-13 UNC-2B .500-13 UNC-2B .500-13 UNC-2B
Ø101,675/101.625 bore 12,50/11,50 deep 0.98 deep 0.98 deep 0.98 deep
J,K ISO 3019/2-100A2 & B2 M12 M12 M12
Ø100,075/100.025 bore 12,50/11,50 deep 25,0 deep 25,0 deep 25,0 deep

106 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models

PVM131/141

Dimensions in millimeters (inches)


“C” Adapter Flange

359,6 (14.16)
∅ “S1” 92,0 (3.62) 4 places

“S4” 4 places

35,0 (1.38)
4 places

“S3”
4 places
“S2”
372,1 (14.65) 2 places

Left Hand Rotation with SAE 2-/4-bolt “C”


and ISO 125 Adapter Flange

Model Code
Position 25 “S1” Thru-drive Flange “S2” 2-bolt Thread “S3” 4-bolt Thread “R4” Support Mounting Points
E,F SAE J744-127-2 & -4 .625-11 UNC-2B .500-13 UNC-2B .500-13 UNC-2B
Ø127,075/127.025 bore 15,50/14,50 deep 0.98 deep 0.98 deep 0.98 deep
L,M ISO 3019/2-125A2 & B4 M16 M12 M12
Ø125,075/125.025 bore 15,50/14,50 deep 25,0 deep 25,0 deep 25,0 deep

Port “B”* “B2” “C”* “C2” “F2” “F3”


2.50 inch dia. SAE J518 .500-13 UNC-2B thd. 1.25 inch dia. SAE J518 .500-13 UNC-2B thd. 146,8 114,9
SAE
Code 61, low pressure 1.19 deep minimum Code 62, high pressure 1.00 deep minimum (5.78) (4.52)
64mm diameter. ISO M12 thread 32mm diameter. M12 thread 148,5 116,6
ISO
6162 Type II, 315 bar 31,0 deep minimum ISO 6162, 400 bar 27,0 deep minimum (5.85) (4.59)
*4-bolt flange port. See page 101 for load sensing, drain, and gage port threads.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 107
Mounting Flange
Options

Dimensions in millimeters (inches)


H

2-bolt “B” Flange G


2-bolt “A, B & C” Flange
ISO & SAE 4-bolt “C” or “D” Flange L
ISO & SAE
F
L
E K

K
G

A H

A
45°
∅ J pilot ∅ J pilot

2-bolt or 4-bolt
Series Flange Code Flange Description A E F G H J K L
2-bolt A SAE J744-82-2 Ø11,14 53,2 106,4 Ø82,53 +.02
PVM018 – –
-.03 – –
PVM020 “A” (4.38) (2.09) (4.19) – – (Ø3.249) +.000
-.001
PVM018 2-bolt B ISO 3019/2-80A2HW Ø11,14 54,5 109,0 – – Ø79,98 +.02
-.03 – –
“A” (4.38) (2.15) (4.29) – (Ø3.15) +.000
PVM020 –
-.001
PVM018
PVM020
PVM045 2-bolt C SAE J744-101-2 14,36 73,0 146,0 – – Ø101,58 +.02
PVM050 “B” -.03 – –
PVM057 (.565) (2.87) (5.75) _ – (Ø3.999) ±.001
PVM063

PVM018
PVM020
PVM045 2-bolt D ISO 3019/2-100A2HW 14,14 70,0 140,0 – – Ø100,00/99,95 – –
PVM050 “B” (special) (.557) (2.76) (5.51) (Ø3.937/3.935)
PVM057
PVM063
E SAE J744-127-2 (“C”) 17,4 90,5 181,0 – – Ø127,00/126,95
(Ø5.000/4.998) –
PVM057 –
(.685) (3.562) (7.125)
PVM063 2-bolt
PVM074 “C” F ISO 3019/2-125A2HW 18,0 90,0 180,0 – – Ø125,00/124,95
(Ø4.921/4.919) – –
PVM081 (.709) (3.543) (7.09)
PVM098 G SAE J744-127-4 (“C”) 14,2 – 57,25 114,50 Ø127,00/126,95 –
PVM106 4-bolt – –
(.559) (2.254) (4.508) (Ø5.000/4.998)
PVM131 “C”
PVM141 H ISO 3019/2-125B4HW 14,0 – – – – Ø125,00/124,95 80,0 160,0
(.551) (Ø4.921/4.919) (3.150) (6.299)
J SAE J744-152-4 (“D”) 20,6 – 80,82 161,64 Ø152,40/152,35 –
– –
PVM131 4-bolt (.812) (3.182) (6.364) (Ø6.000/5.998)
PVM141 “D” K ISO 3019/2-160B4HW 18,0 – Ø160,00/159,95 100,0 200,0
– – –
(.709) (Ø6.299/6.297) (3.937) (7.874)
*Flanges for PVM020 and PVM050 are shown on pages 73 and 80, respectively.

108 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Shaft Options

Dimensions in millimeters (inches)


C
B spline

SAE Splined Shaft

∅A

SAE Spline Shaft Max. Input Torque


Model Series Designation Shaft Code A max. B C D Nm (lb. in.)
SAE J744-16-4 03 15,88 (.625) 9T 16/32 DP 37,0 (1.46) 32,0 (1.26) 58 (517)
SAE “A” (9T)
SAE J744-19-4 04 19,05 (.750) 11T 16/32 DP 30,0 (1.18) 38,0 (1.50) 123 (1100)
SAE “A” (11T)
PVM018/020
SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
SAE J744-25-4 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
PVM045/050
SAE J744-25-4 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
SAE J744-25-4
PVM057/063 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
SAE “C” (14T)
SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
PVM074/081 SAE “C” (14T)
PVM098/106 SAE J744-38-4 12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750)
SAE “C-C” (17T)
SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
SAE “C” (14T)
SAE J744-38-4
PVM131/141 12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750)
SAE “C-C” (17T)
SAE J744-44-4 14 43,71 (1.721) 13T 8/16 DP 67,0 (2.63) 75,0 (2.95) 1215 (10,750)
SAE “D” (13T)

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 109
Shaft Options

Dimensions in millimeters (inches)


E key C

SAE Keyed Shaft

B ∅A

Max. Input
SAE Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
SAE J744-16-1 4,0 (.157) 58
01 15,88 (.625) 17,73 (.698) 24,0 (.94) 32,0 (1.26)
SAE “A” (517)
SAE J744-19-1 4,81 (.189) 104
02 19,05 (.750) 21,23 (.836) 24,0 (.94) 32,0 (1.26)
SAE “19-1” (918)
PVM018/020
SAE J744-22-1 6,35 (.250) 135
05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61)
SAE “B” (1200)
SAE J744-25-1 6,35 (.250) 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81)
SAE “B-B” (1900)
SAE J744-22-1 135
05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250)
SAE “B” (1200)
PVM045/050
SAE J744-25-1 6,35 (.250) 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81)
SAE “B-B” (1900)
SAE J744-25-1 6,35 (.250) 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81)
SAE “B-B” (1900)
PVM057/063
SAE J744-32-1 7,93 (.312) 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20)
SAE “C” (3980)
SAE J744-32-1 7,93 (.312) 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20)
PVM074/081 SAE “C” (3980)
PVM098/106 SAE J744-38-1 9,52 (.375) 765
10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44)
SAE “C-C” (6770)
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
SAE “C” (3980)
SAE J744-38-1 765
PVM131/141 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375)
SAE “C-C” (6770)
SAE J744-44-1 1200
13 44,45 (1.75) 49,46 (1.95) 67,0 (2.63) 75,0 (2.95) 11,11 (.438)
SAE “D” (10,620)

110 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Shaft Options

Dimensions in millimeters (inches)

D key

ISO Keyed Shaft

E ∅A

Max. Input
ISO Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
ISO 3019/2 E20N 15 19,9 (.786) 8,5 (.335) 36 (1.42) 6 (.236) 22,5 (.886) 113 (1000)
PVM018/020 ISO 3019/2 E25N
Short Spigot 16 25 (.984) 8,5 (.335) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM045/050 ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM057/063 ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
ISO 3019/2 E32N 18 32 (1.26) 10 (.393) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM074/081 ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM098/106 ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 870 (7700)
PVM131/141 ISO 3019/2 E32N 18 32 (1.26) 10 (.393) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
ISO 3019/2 E40N 19 40 (1.57) 10 (.393) 82 (3.23) 12 (.472) 43,0 (1.693) 870 (7700)
ISO 80mm pilot only – B
(1)

ISO 80mm pilot only – D


(2)

*Torque of non-thru-drive PVM pump, or combined torque of PVM thru-drive pump and thru-driven pump.
NOTE: In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified,
consult Eaton Engineering for specific limits.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 111
Input Shaft
Selection Data

SAE Splined Shafts

Max. Input Torque† Max. Thru-drive Output Torque‡


Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
SAE J744-16-4 (SAE “A,” 9T) 03 58 (513) Exceeds maximum input torque
SAE J744-19-4 (SAE “A,” 11T) 04 123 (1100) Exceeds maximum input torque
PVM018/020
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 123 (1100)
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 123 (1100)
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
PVM045/050
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987)
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
PVM057/063 SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987)
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 337 (2987)
PVM074/081 SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 515 (4560)
PVM098/106 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 515 (4560)
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 640 (5660)
PVM131/141 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 640 (5660)
SAE J744-44-4 (SAE “D,” 13T) 14 1215 (10,750) 640 (5660)

SAE Keyed Shafts

Max. Input Torque† Max. Thru-drive Output Torque‡


Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
SAE J744-16-1 (SAE “A”) 01 58 (513) Exceeds maximum input torque
SAE J744-19-1 (SAE “19-1”) 02 104 (920) Exceeds maximum input torque
PVM018/020
SAE J744-22-1 (SAE “B”) 05 135 (1200) 123 (1100)
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 123 (1100)
SAE J744-22-1 (SAE “B”) 05 135 (1200) 135 (1200)*
PVM045/050
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
PVM057/063
SAE J744-32-1 (SAE “C”) 09 450 (3980) 337 (2987)
PVM074/081 SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*
PVM098/106 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 515 (4560)
SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*
PVM131/141 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 640 (5660)
SAE J744-44-1 (SAE “D”) 13 1200 (10,620) 640 (5660)

ISO Keyed Shafts

Max. Input Torque† Max. Thru-drive Output Torque‡


Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
ISO 3019/2 E20N (B mount only) 15 113 (1000) Exceeds maximum input torque
PVM018/020 ISO 3019/2 E25N (B mount only) 16 215 (1900) Exceeds maximum input torque
ISO 3019/2 E25N (D mount only) 17 215 (1900) 123 (1100)
PVM045/050 ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
PVM057/063
ISO 3019/2 E32N 18 450 (3980) 337 (2987)
PVM074/081 ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
PVM098/106 ISO 3019/2 E40N 19 870 (7700) 515 (4560)
ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
PVM131/141
ISO 3019/2 E40N 19 870 (7700) 640 (5660)
†Maximum total torque of the thru-drive pump and the thru-driven pump(s).
‡Maximum torque that can be applied to the thru-driven pump(s).
*This value is limited by the maximum input torque.

112 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Port Options

Inlet and Outlet Ports

Inlet/Outlet Port Option Port


Model Series (per model code, page 5) Code Inlet Port “B” Outlet Port “C”
02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange
1.25 inch diameter, .4375-14 x 1.12 bolt holes 0.75 inches diameter, .375-16 x .88 bolt holes
04 ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar.
Metric Flange
PVM018/020 31,75mm diameter, M10 x 28 bolt holes 19,05mm diameter, M10 x 22 bolt holes
Inch Tube 01 SAE J514 O-ring –20, for 1-1/4 inch O.D. tube SAE J514 O-ring -12, for 3/4 inch O.D. tube
Metric Tube 03 ISO 6149-1, M42 thread ISO 6149-1, M27 thread
British Parallel Pipe 05 ISO 228-1:1994 (E), G 1-1/4 thread ISO 228-1:1994 (E), G 3/4 thread
02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange
2.00 inch diameter, .500-13 x 1.06 bolt holes 1.00 inch diameter, .375-16 x .87 bolt holes
04 ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar.
Metric Flange
PVM045/050 51mm diameter, M12 x 27 bolt holes 25mm diameter, M10 x 22 bolt holes
Inch Tube 01 SAE J514 O-ring -24, for 1-1/2 inch O.D. tube SAE J514 O-ring -16, for 1 inch O.D. tube
Metric Tube 03 ISO 6149-1, M48 thread ISO 6149-1, M33 thread
British Parallel Pipe 05 ISO 228-1:1994 (E), G 1-1/2 thread ISO 228-1:1994 (E), G1 thread
02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange
2.00 inch diameter, .500-13 x 1.06 bolt holes 1.00 inch diameter, .375-16 x .88 bolt holes
04 ISO 6162 Type II, 350 bar. ISO 6162 Type, 350 bar.
Metric Flange
51mm diameter, M12 x 29 bolt holes 25mm diameter, M10 x 23 bolt holes
PVM057/063
Inch Tube 01 SAE J514 O-ring -24, SAE J514 O-ring
(End ported models only) for 1-1/2 inch O.D. tube -16 for 1 inch O.D. tube
Metric Tube
(End ported models only) 03 ISO 6149-1, M48 thread ISO 6149–1, M33 thread

02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange
2.00 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375 -16 x .88 bolt holes
PVM074/081
04 ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar.
Metric Flange
51mm diameter, M12 x 20 bolt holes 25mm diameter, M10 x 17 bolt holes
02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange
2.50 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375 -16 x .88 bolt holes
PVM098/106
04 ISO 6162 Type I, 350 bar. ISO 6162 Type I, 350 bar.
Metric Flange
64mm diameter, M12 x 31 bolt holes 25mm diameter, M10 x 23 bolt holes
02 SAE J518 Code 61, standard pressure. SAE J518 Code 62, high pressure.
Inch Flange
2.50 inch diameter, .500-13 x 1.19 bolt holes 1.25 inch diameter, .500 -13 x 1.00 bolt holes
PVM131/141
04 ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar.
Metric Flange
64mm diameter, M12 x 31 bolt holes 32mm diameter, M12 x 27 bolt holes

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 113
Port Options

Drain, Load Sensing, and Gauge Ports

Inlet/Outlet Port Option Port


Model Series (per model code, page 5) Code Drain Port “F” Load Sensing Port “J” Gauge Port “K”
Inch Flange or Tube 01, 03 SAE J514 O-ring, .50’’ O.D. SAE J514 O-ring, .25’’ O.D. SAE J514 O-ring, .25’’ tube.
tube. .750-16 UNF 2B thread tube. .4375-20 UNF 2B thread .4375-20 UNF 2B thread
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
PVM018/020
M18 x 1,5 thread M12 x 1,5 thread M12 x 1,5 thread
British Parallel Pipe 05 ISO 228-1:1994 (E) ISO 228-1:1994 (E) ISO 228-1:1994 (E)
G 1/2 thread G 1/4 thread G 1/4 thread
Inch Flange or Tube 01, 03 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .250’’ O.D. SAE J514 O-ring, .375’’ O.D. tube.
tube. .875-14 UNF 2B thread tube. .4375-20 UNF 2B thread .5625-18 UNF 2B thread
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
PVM045/050
M22 x 1,5 thread M12 x 1,5 thread M14 x 1,5 thread
British Parallel Pipe 05 ISO 228-1:1994 (E) ISO 228-1:1994 (E) ISO 228-1:1994 (E)
G 1/2 thread G 1/4 thread G 1/4 thread
Inch Flange or Tube 01, 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’’ O.D. tube.
tube. .875-14 UNF 2B thread tube. .5625-18 UNF 2B thread .5625-18 UNF 2B thread
PVM057/063
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
Inch Flange 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’’ O.D. tube.
PVM074/83 tube. .875-14 UNF 2B thread tube. .562-18 UNF 2B thread .5625-18 UNF 2B thread
PVM098/106 Metric Flange 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
Inch Flange 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’’ O.D. tube.
tube. .875-14 UNF 2B thread tube. .562-18 UNF 2B thread .5625-18 UNF 2B thread
PVM131/141
Metric Flange 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
Operating
Requirements

Inlet Pressure, case pressure, and operating temperature requirements

Inlet Pressure Case Pressure Operating Temperature


Rated Minimum Maximum Maximum Maximum Maximum
Absolute bar, absolute Gauge Continuous Intermittent Peak Rated Intermittent
bar (psi) (in. Hg) bar (psi) bar (psi) bar (psi) bar (psi) °C (°F) °C (°F)
1,0 (14.5) 0,85 (5) 3,5 (50) 0,5 (7) 2 (30) 3,5 (50) 82 (180) 104 (220)

Hydraulic Fluids

Minimum Viscosity @ Max.


Recommended Operating Maximum Viscosity Intermittent Temperature of
Viscosity Range at Startup 104°C (220°F)
Fluid cSt (SUS) cSt (SUS) cSt (SUS)
Use antiwear hydraulic oil, or automotive
type crankcase oil (designations SC, SD, SE, 16 to 40 (83 to 187) 1000 (4550) 10 (90)
or SF) per SAE J183 FEB80
For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative.

Fluid Cleanliness Proper fluid condition is Moment of Inertia (single pump rotating group)
The M Series pumps are rated essential for long and satisfac­
in anti-wear petroleum fluids tory life of hydraulic components Model Moment of Inertia
with a contamination level of and systems. Hydraulic fluid
must have the correct balance N-m (sec2) lbf-in (sec2)
20/18/13 (Eaton) or ISO 18/13.
Operation in fluids with levels of cleanliness, materials, and PVM018 0.0012 0.0104
more contaminated than this is additives for protection against PVM020 0.0012 0.0104
not recommended. Fluids other wear of components, elevated
viscosity and inclusion of air. PVM045 0.0036 0.0320
than petroleum, severe service
cycles, or temperature extremes Essential information on the PVM050 0.0034 0.0300
are cause for adjustment of correct methods for treating PVM057 0.0052 0.0457
these codes. Please contact hydraulic fluid is included in PVM063 0.0051 0.0447
your Eaton Representative Eaton publication 561 –
for specific duty cycle recom­ “Eaton Guide to Systemic PVM074 0.0078 0.0691
mendation. Contamination Control” – PVM081 0.0073 0.0643
Eaton M Series pumps, as Available from your local Eaton
PVM098 0.0132 0.1165
with any variable displacement distributor. In this publication,
filtration and cleanliness levels PVM106 0.0123 0.1086
piston pumps, will operate with
apparent satisfaction in fluids for extending the life of axial PVM131 0.0213 0.1889
up to the rating specified here. piston pumps and other system
components are listed. Included PVM141 0.0210 0.1856
Experience has shown, how-
ever, that pump and hydraulic is an excellent discussion of the
system life is not optimized with selection of products needed to
high fluid contamination levels control fluid condition.
(high ISO cleanliness codes).
Installation and
Start-up

Warning: Care should be taken In those cases where geomet- Start-up Procedure Once the pump is started,
that mechanical and hydraulic ric tolerances of mounting are Make sure the reservoir and it should prime within a few
resonances are avoided in the critical, or where specific toler- circuit are clean and free of seconds. If the pump does not
application of the pump. Such ance ranges are required and dirt/debris prior to filling with prime, check to make sure
resonances can seriously not specified, consult Eaton hydraulic fluid. that there are no restrictions
compromise the life and/or safe Engineering for specific limits. between the reservoir and the
operation of the pump. Fill the reservoir with filtered inlet to the pump, that the pump
Direction of shaft rotation, oil and fill to a level sufficient
viewed from the prime mover is being rotated in the proper
Drive Data enough to prevent vortexing at direction, and that there are no
end, must be as indicated in the suction connection to pump
the model designation on the air leaks in the inlet line and con-
Mounting attitude can be either inlet. It is good practice to nections. Also check to make
horizontal or vertical, using the pump – either right hand clean the system by flushing
(clockwise) or left hand (counter- sure that trapped air can escape
appropriate case drain ports to and filtering, using an external at the pump outlet.
ensure that the case remains clockwise). slave pump.
full of fluid at all times. Consult Direct coaxial drive through After the pump is primed,
your local Eaton Representative Caution: Before the pump is tighten the loose outlet con­
a flexible coupling is recom- started, fill the case through
if a different arrangement is mended. If drives imposing nections, then operate for five
required. the uppermost drain port with to ten minutes (unloaded) to
radial shaft loads are considered, hydraulic fluid of the type to be
please consult your Eaton remove all trapped air from
used. The case drain line must the circuit.
Representative. be connected directly to the res-
ervoir and must terminate below If the reservoir has a sight gage,
the oil level. make sure the fluid is clear –
not milky.

116 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
This page intentionally blank.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 117
This page intentionally blank.

118 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
This page intentionally blank.

EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009 119
Eaton Eaton Eaton
Hydraulics Business USA Hydraulics Business Europe Hydraulics Business Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 11th Floor Hong Kong New World Tower
Eden Prairie, MN 55344 1110 Morges 300 Huaihai Zhong Road
USA Switzerland Shanghai 200021
Tel: 952-937-9800 Tel: +41 (0) 21 811 4600 China
Fax: 952-294-7722 Fax: +41 (0) 21 811 4601 Tel: 86-21-6387-9988
www.eaton.com/hydraulics Fax: 86-21-6335-3912

© 2009 Eaton Corporation


All Rights Reserved
Printed in USA
Document No. V-PUPI-TM007-E
Supercedes V-PP-MC-0003-E, V-PP-MC-0004-E
February 2009

You might also like