Professional Documents
Culture Documents
The Troubleshooting Method For 198097060: "Board Communication Link Interrupted " in BPK
The Troubleshooting Method For 198097060: "Board Communication Link Interrupted " in BPK
BPK
There is one bug in UR13(We test it in SDR4.13.10.30P43). the software BUG will lead
to BPK board start failure in the frequent power-down,The board can not be started
during the Boot phase and the start process be stopped in the below step
KUBoot ..............login:. This faulty board can be recovered remotely by the command via
telnet.
The alarm code:Board communication link interrupted(198097060)
2. Operation Procedure
a. telnet to CC board
b. telnet to BPK board from CC(The BPK board in slot 8 in the example site)
slot IP
3 192.254.3.16
4 192.254.4.16
5 192.254.5.16
6 192.254.6.16
7 192.254.7.16
8 192.254.8.16
After telnet to the BPK board,If it display the message KUBoot ..............login:
,We can fix the issue by the below method.If the message does not
display,pls abort the operation due to the issue can not be fixed by the
the the system will in character mode. After entering character mode, the
Since here the input and output will be visable.The output shows as below.
f. Input reboot(enter). The BPK will reboot
Close the telnet window and wait for 5 minutes.Check the alarm