GENERAL NOTES FOR ARCHITECTURAL WORKS
GENERAL NOTES LEGEND AND SYMBOL MATERIAL LEGEND ABBREVIATION

PLAN/SECTION A ARCHITECTURAL
1. GENERAL NOTES AND GENERAL CONDITIONS DEFINE THE RULES AND CONDITION GOVERNING THE WORK.
ACT ACOUSTICAL CEILING TILE
EARTH/COMPACT FILL PLYWOOD-LARGE SCALE AHU AIR HANDLING UNIT
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODES
AND SHALL CONFORM TO ALL APPLICABLE REGULATIONS RELATED TO OCCUPATIONAL SAFETY, HEALTH, ETC. ALUM ALUMINUM
CAST IN PLACE/ PLYWOOD-SMALL SCALE
CONCRETE CEM CEMENT
3. REFER TO APPLICABLE SECTIONS OF THE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
CHEM CHEMICAL
SAND/MORTAR/CEMENT GLASS
4. THE EXECUTION OF WORK UNDER THE TERMS AND CONDITIONS OF THESE CONTRACT DOCUMENTS REQUIRES PLASTER INDICATION COL COLUMN
COORDINATION WITH OTHER CONTRACTORS ON THE SITE. CONC CONCRETE
COMPACTED GRAVEL FILL GRANITE
5. ADDITIONAL NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. NOTES ON ANY CONT CONTINIOUS
ONE SHEET ARE TO BE APPLIED ON RELATED DRAWINGS AND DETAILS. CHB CONCRETE HOLLOW BLOCKS
EXISTING INSULATION
CMU CONCRETE MASONRY UNIT
6. DIMENSIONING
A. ALL DIMENSIONS GIVEN IN THESE DRAWINGS ARE IN MILLIMETERS (mm) AS INDICATED (1M=1,000mm, DEP DEPRESSION
NEW CONCRETE BLOCK RIGID
1CM=100mm, .05M=50mm) EXCEPT FOR THE METAL PLATES, SHAPES, SCREWS, BOLTS AND PIPES IN SMALL SCALE DET DETAIL
IMPERIAL MEASUREMENTS DS DOWSPOUT
B. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS AND NOTES SHALL ESTABLISH ALL LOCATIONS. ALUMINUM ACOUSTICAL TILE
DWG DRAWING
LARGER SCALE DRAWINGS SHALL HAVE PRIORITY OVER SMALLER SCALE DRAWINGS
C. UNLESS OTHERWISE INDICATED, ALL DIMENSIONS IN ARCHITECTURAL PLAN AND ELEVATIONS ARE FINISH EQ EQUAL
DIMENSIONS. REFER TO THE STRUCTURAL DRAWINGS FOR CONCRETE OPENING. REFER TO THE DETAIL STEEL/OTHER METALS CERAMIC TILE-SMALL SCALE
EXIST EXISTING
FOR MASONRY OPENING.
EWC ELECTRIC WATER COOLER
D. MASONRY DIMENSIONS ON PLANS ARE NOMINAL BLOCK SIZES. CARPET PAD
WOOD FINISH
E. CONTRACTORS SHALL CONFIRM EVERY DIMENSION INDICATED ON PLANS TO THE CONSTRUCTION EW EYE WASH
SUPERVISOR TO AVOID MISUNDERSTANDING. FFL FINISH FLOOR LINE
F. CONTRACTOR SHALL VERIFY (IN THE FIELD) ALL MASONRY DIMENSIONS BEFORE PREPARATION OF SHOP ROUGH FICEM BOARD
FGL FINISH GRADE LINE
DRAWINGS OF FABRICATION OF DOORS, WINDOWS, CABINETRY OR BUILT-IN EQUIPMENT.
FIN FINISH
BLOCKING FICEM BOARD (PLAN)
9. UNLESS OTHERWISE INDICATED, ALL INTERIOR MASONRY PARTITIONS SHALL STOP AT 200mm OR ONE COURSE FLR FLOOR
ABOVE SUSPENDED CEILING OR AT UNDERSIDE OF SLAB/BEAM WHERE THERE IS NO SUSPENDED CEILING.
FHC FIRE HOUSE CABINET
WHERE THE FIRE RATED OCCUPANCY IS SHOWN ON THE DRAWINGS MASONRY PARTITIONS SHALL EXTEND FROM INSULATION METAL LATH AND PLASTER
FLOOR TO UNDERSIDE OF BEAM, SLAB, OR ROOF CONSTRUCTION. LOW MASONRY PARTITIONS ARE INDICATED FS FLOOR SPRAY
ON FLOOR PLANS BY HEIGHT (FOR EXAMPLE HT. 1000). FIRE STOPPING INSULATION HD HAND DRYER
(INTUMESCENT STRIP)
HW HANDWASH
10. UNLESS OTHERWISE INDICATED ON FLOOR PLANS, ALL DOORS SHALL BE FURTHER ADJUSTED AS REQUIRED TO
CLEAR LARGE DOOR CLOSERS, SPECIAL HARDWARE PIPING PANEL BOARD, PLUMBING FIXTURES AND OTHER ELEVATION LAV LAVATORY
BUILT-IN OBJECTS. LN LINE
ALUMINUM/GLASS WALL GLASS LSD LIQUID SOAP DISPENSER
11. ARCHITECTURAL DRAWINGS DO NOT SHOW SIZE OF STRUCTURAL ELEMENTS. FOR SIZES AND PLACING OF
STRUCTURAL ELEMENTS SEE STRUCTURAL DRAWINGS. MACH MACHINE
METAL STUD SHEET METAL MAINT. MAINTENANCE
12. FOR EXACT LOCATION OF ROOF OPENINGS FOR DUCTS, PIPING AND FANS, SEE STRUCTURAL AND MECHANICAL
MH MOUNTING HEIGHT
DRAWINGS. FOR LOCATION AND SIZE OF DUCT WORK PENETRATING INTERIOR PARTITIONS, SEE MECHANICAL
CERAMIC TILE MIRROR
DRAWINGS. MO MOUNTING OPENING

mm MILLIMETER
13. ALL PLUMBING STUB OUT SHALL BE AT THE INTERSECTION OR AT THE MIDDLE OF THE CERAMIC WALL TILE. CONCRETE PLASTER
PVC POLYVINYL CHLORIDE

14. IF CONFLICT OCCURS BETWEEN DRAWINGS AND SPECIFICATIONS, THE ORDER OF PRECEDENCE SHALL BE AS PEJ PREMOULDED EXPANSION JOINT
FOLLOWS: RC REINFORCED CONCRETE
A. GENERAL CONDITIONS C. LARGE SCALE DRAWINGS RD ROOF DRAIN
B. THE DETAIL SPECIFICATIONS D. SMALL SCALE DRAWINGS
RM ROOM
15. COORDINATION SHALL BE REQUIRED FOR ALL EQUIPMENT BASES AND HOUSEKEEPING PADS WITH MECHANICAL, LAYER SYSTEM RS ROOF STRAINER
PLUMBING AND ELECTRICAL DRAWINGS AND MANUFACTURER'S SHOP DRAWINGS. EQUIPMENT BASES AND SS SLOP SINK
HOUSEKEEPING PADS ARE TO BE CONSTRUCTED AS PER APPROVED SHOP DRAWINGS.
LAYER LINETYPE LINEWEIGHT COLOR CONTENT STRUCT'L STRUCTURAL

16. THE CONTRACTOR TO COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR AND WALL SLEEVES, AND ALL AIR [ GENERAL ] TPH TOILET PAPER HOLDER
DUCTS, PIPE SHAFTS AND BUS DUCT THAT PENETRATE FLOOR SLABS, AND FIRE SEPARATION WALLS SHALL BE TPD TOILET PAPER DISPENSER
INSTALLED IN A MANNER THAT WILL PRESERVE THE FIRE RESISTIVE AND STRUCTURAL INTEGRITY OF THE
THK THICK
BUILDING.
UR URINAL
17. WORK INDICATED ON THE DRAWINGS AS 'NIC' IS NOT IN CONTRACT. COORDINATION WITH OTHER CONTRACTORS W WIDTH
INCLUDING CONTRACTORS FOR ELECTRICAL WORK, CONVEYING SYSTEM, COMMUNICATION SYSTEM, BAGGAGE TEXT 0.30 GREEN TEXT
WC WATER CLOSET
HANDLING SYSTEM(BHS), FURNITURE, FIXTURE AND SIGNAGE, ETC.
WH WATER HEATER
18. REFER TO CERTIFIED MECHANICAL & ELECTRICAL SHOP DRAWINGS AND MANUFACTURER'S INSTALLATION W/ WITH
DRAWINGS FOR ALL MECHANICAL AND ELECTRICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES,
ISOLATIONS, SPRING ISOLATIONS, ETC. , NOT SHOWN ON THE DRAWINGS.

19. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY SEPARATED TO AVOID GALVANIC ACTION.

20. COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH ALL TRADES INVOLVED INCLUDING MECHANICAL,
ELECTRICAL AND COMMUNICATIONS SYSTEM INSTALLERS. WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS
AND INSTALLATION, REVIEW WITH THE GENERAL CONTRACTOR PRIOR TO PROCEEDING.
FIRE PROTECTION
1. ALL MATERIAL OR ASSEMBLIES REQUIRED TO HAVE A FIRE RESISTANCE RATING SHALL COMPLY WITH ONE OF
THE FOLLOWING:
A. IT SHALL CONFORM WITH THE PHILIPPINES LOCAL FIRE CODE, OR
B. IT SHALL HAVE BEEN ACCEPTABLE PRIOR TO THE EFFECTIVE DATE OF THE CODE.

[ ELEVATION ]

DEPARTMENT OF TRANSPORTATION
AND COMMUNICATIONS

SCHEMA Konsult Inc. Joint Venture with


PERTCONSULT International
DCCD Engineering Corporation
Project Manager Project Manager, DOTC-PMO
Philipp's Technical Consultants Corp.
DEPARTMENT OF TRANSPORTATION
AND COMMUNICATIONS

SCHEMA Konsult Inc. Joint Venture with


PERTCONSULT International
DCCD Engineering Corporation
Project Manager Project Manager, DOTC-PMO Assistant Secretary Undersecretary For Project
Philipp's Technical Consultants Corp. Project Implementation, DOTC
DEPARTMENT OF TRANSPORTATION
AND COMMUNICATIONS

SCHEMA Konsult Inc. Joint Venture with


PERTCONSULT International
DCCD Engineering Corporation
Project Manager Project Manager, DOTC-PMO Assistant Secretary Undersecretary For Project
Philipp's Technical Consultants Corp. Project Implementation, DOTC

You might also like