The document calculates the required bolt size and number to hold down a structure based on the maximum shear and overturning moment. It specifies the material properties and stresses of bolt grade A325 Type 1, and provides the maximum forces of 15,000 N for shear and 25,000 Nmm for overturning moment. Based on these values, bolt size M20 with 6 bolts is determined to be sufficient.
The document calculates the required bolt size and number to hold down a structure based on the maximum shear and overturning moment. It specifies the material properties and stresses of bolt grade A325 Type 1, and provides the maximum forces of 15,000 N for shear and 25,000 Nmm for overturning moment. Based on these values, bolt size M20 with 6 bolts is determined to be sufficient.
The document calculates the required bolt size and number to hold down a structure based on the maximum shear and overturning moment. It specifies the material properties and stresses of bolt grade A325 Type 1, and provides the maximum forces of 15,000 N for shear and 25,000 Nmm for overturning moment. Based on these values, bolt size M20 with 6 bolts is determined to be sufficient.
Maximum shear force at bottom Fmax. = Max( Fw, Fs, Ft ) = 15000 N Maximum overturning moment at Mmax. = Max( Mw, Ms, Mt ) = 25000 Nmm Bolt material - A325 Type 1 Bolt yield stress Sy = 634 MPa Bolt ultimate tensile stress Su = 827 MPa Allowable tensile stress Ft = 372 MPa Allowable shear stress Fs = 207 MPa Bolt size = M20 Number of bolts N = 6 Nos. Tensile area AT = 245 Shear area As = 225 Bolt PCD PCD = 1750 mm