STATIK PERHITUNGAN

Project : Merakes Field Development


Client : Technip FMC
Date : 02/09/2020
Subject : Swivel Clamp BS

Data Teknis

Load Assumption :
Breaking Load = 17 kN
= 1700 kg

Material Properties :
Allowable Max. Compression = 850 kg (Safety Load 50% dari Breaking Load)

Section Area :
Berat Hoist = 350 kg
Jarak Tumpuan X = 120 cm
Jarak Tumpuan Y = 120 cm

STRUCTURE ANALYSIS
Total Beban = 350 kg < Allowable Load = 850 …………… OK !!!

Note :
1. Maximum load that GI Pipe allowed is 1600 kg
2. Maximum load that Swivel Clamp allowed is 850 kg.
3. Use the smallest maximum load