Professional Documents
Culture Documents
Saudi Aramco Inspection Checklist: SAIC-L-1003 29-Jun-17
Saudi Aramco Inspection Checklist: SAIC-L-1003 29-Jun-17
Saudi Aramco Inspection Checklist: SAIC-L-1003 29-Jun-17
00 28-Feb-17
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Pipe Lowering Inspection SAIC-L-1003 29-Jun-17 CIVIL -
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR
EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
The bottom of the trench shall be free of rocks and other materials that SAEL-L-450
A1
can damage the pipe or pipe coating. Sec. 14.8.2
Slings for lifting pipe shall be nylon or similar material to prevent damage SAES-L-450
A2
to the pipe surfaces. Wire rope slings shall not be used. Sec. 8.5
SAES-L-450
A3 Pipe shall not be rolled or dropped off of trucks.
Sec. 8.6
Internally coated pipe shall be handled from the outside diameter (O.D.) SAES-L-450
A4
only. Sec. 8.7
Pipe strings or portions thereof shall not be moved until all joints have SAES-L-450
A5
been fully welded and inspected. Sec. 11.3
Open ends of pipe strings shall be capped to prevent entry of debris or SAES-L-450
A6
animals and birds. Sec. 11.4
SAES-L-450
A7 Each string of the pipeline shall be cleaned to remove all debris.
Sec. 11.5
REMARKS:
REFERENCE DOCUMENTS:
1- SAES-L-450 -- Construction of On-Land and Near Shore Pipelines, 12 October 2015