Problem:
Solution:
New generation of exposure PCBs will be implemented from machine 1711 and over.
The main improvements are the field adjustment and better compensation of pixels.
Composition:
- LVDS Cable: SCSI link cable between Cicclone and Ravage PCB.
Cicclone pcb
Ravage pcb
LVDS Cable
THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
TECHNICAL INFO EXPRESS
MACHINE : DKS & SYSTEM 88
Date : 22/04/02 SAV IET N°46 V02 ed 01 Page : 2/2
Technical description:
RAVAGE TFT
Computer Computer
Machine input Machine input
Digital Digital
Cicclone on HR on
PCI slot PCI slot
Analog
Analog
Ravage pcb LCD Unit TFT pcb LCD Unit
Digital / Analog
The main difference between these two configurations is that the new system is
sending numeric information to the LCD PCB (Ravage) while it was Analog on the
former system.
On the Ravage PCB, we have replaced all potentiometers adjustments of the TFT by
an auto set up technology based on an INI file called Ravage.ini.
This ini file corresponds to tensions applied on the Ravage board.
We need one Ravage.ini file and one PRNU file to expose images correctly.
The Ravage.ini file set the goods values of tensions required to expose images
(instead of the potentiometers on the former system).
If one of two PCB is defective, we have to replace it and from a base of ravage.ini
file, we have to define new value with the maintenance software.
THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.