Professional Documents
Culture Documents
The World's Most Extensive Selection of Ductless Fume Hoods.
The World's Most Extensive Selection of Ductless Fume Hoods.
— Purair 10
JUMP TO:
Features
and Callouts (p.3)
Purair ® Controller
Options (p.4) Advanced Ductless Fume Hood Group
Airflow and Multiplex™ High operator protection to fume
Filtration Technology (p.5) and particle hazards.
High capacity.
INTRODUCTION
The Purair ® Advanced Series ductless fume hoods are filter changes. Set-up,
operation and filter
a series of high efficiency products designed to protect maintenance are
the user and the environment from hazardous vapors straightforward.
• Energy Efficient.
generated on the work surface. At the heart of the Purair Because filtered air
APPLICATIONS fume hood product line is the innovative Air Science is returned to the room,
• Capsule Filling no demands are
Multiplex™ Filtration Technology that creates a safe work required of the facility
• Chemical Sampling
• Dental Labs
environment over the widest range of applications in HVAC capacity for
make-up air.
• Drug & Chemical the industry.
Analysis • Cost Effective. Facility
ductwork, HVAC and
• Forensics
construction costs
• Histology are eliminated.
• Ink Fumes DUCTLESS • Safer Filter available in more
TECHNOLOGY: Replacement. than 14 configurations • Safe to Use. Cabinet
• Light Grinding
The Eco-friendly The SafeSwitch is a for use with vapors airflow and face
• Pharmaceutical velocity protect
Choice unique filter shutter of organic solvents,
• Pipetting system that closes the acids, mercury, users from incidental
Advanced carbon
• Slide Staining filtration technology exposed filter media formaldehyde. HEPA/ exposures to fumes.
• Spray Adhesives offers a safe, high per- face and minimizes ULPA filters can be
• Self testing. (selected
• Weighing formance alternative to exposure to the added for biological
models) Electronic air
conventional ducted contaminated filters, safety.
flow monitoring assures
fume hoods for a broad protecting the operator
• Easy to Install. The continuous safety. An
range of applications. and the environment
ductless fume hood electronic gas sensor
from contaminants.
• Environmental is self-contained and monitors carbon filter
Benefits. Air Science • Versatile. Each does not require performance.
ductless fume hoods filtration system is venting to the outside.
isolate and trap selected for its Many units are port-
chemical vapors to specific application. able and may be
prevent ecological The Multiplex Filter moved from one
impact through broadens the range location to the next
release into the of applications. with minimal down-
environment. Carbon filters are time and without
PRODUCT FEATURES:
A. Filter I.D. Window: A strategically placed front
cover window shows the installed filter part number and
installation date for convenience and to encourage
timely filter replacement.
OTHER FEATURES:
360 Degree Visibility: Clear back and side panels
allow ambient illumination into the chamber and provide
users with an unobstructed view of its contents.
Air Science ®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
p:4 Product Features Ductless Fume Hoods 10 • 10XL • 15 • 20 • 25 • 30 • 40
PURAIR ADVANCED
FEATURES & BENEFITS
Purair Advanced
products are available
in 21 standard sizes, in
metal or polypropylene
construction, totaling
42 standard models.
• Purair Advanced
product line is
available in seven
standard sizes.
• A unique filter
clamping design
eliminates bypass
leakage outside
the cabinet.
• Accessories
include an optional The optional Monitair microprocessor controller monitors and displays cabinet operating parameters,
filter saturation airflow, containment, and filter condition; emits audio and visual alerts if conditions become unsafe,
all on a LCD display.
alarm and optional
back-up filter.
• SafeSwitch Filter
Shutter System
available for safer
filter exchange.
-- Specify Specify
Air Science ®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
p:7 Product Specifications Ductless Fume Hoods 10 • 10XL • 15 • 20 • 25 • 30 • 40
Tall Models
38" 30" x 27.375" x 53" 50" x 40" x 42"
P10-XT P10-XT-PP 111 / 50 164 / 74
965 mm 762 x 695 x 1346 mm 1270 x 1016 x 1067 mm
Air Science ®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
p:8 Product Specifications Ductless Fume Hoods 10 • 10XL • 15 • 20 • 25 • 30 • 40
[shallow
[standard] [tall]
depth]
PRODUCT SPECIFICATIONS
Face Velocity FPM 100 100 100 100 100 100 100
Noise, dBA, 1 meter < 50 < 50 < 53 < 53 < 53 < 56 < 67
Lighting LED
Construction <… White epoxy coated steel frame and head unit. Clear sides and back panel. Polypropylene spill tray. …>
Blower <… EBM centrifugal fan. …>
Electrical <… 110V, 60Hz or 220V, 50Hz voltages available. Specify when ordering. Other voltage options available. …>
Filter Specifications
Pre-Filter Electrostatic, 1 lb / .45 kg (nominal)
Main Filter, Carbon (1) 22 lbs / 9.6 kg (1) 22 lbs / 9.6 kg (1) 22 lbs / 9.6 kg (2) 44 lbs / 20 kg (2) 44 lbs / 20 kg (2) 44 lbs / 20 kg (3) 66 lbs / 30 kg
Safety Filter, Carbon (1) 11 lbs / 5 kg (1) 11 lbs / 5 kg (1) 11 lbs / 5 kg (2) 22 lbs / 9.6 kg (2) 22 lbs / 9.6 kg (2) 22 lbs / 9.6 kg (3) 33 lbs / 15 kg
Safety Filter, Biological (1) HEPA / ULPA (1) HEPA / ULPA (1) HEPA / ULPA (2) HEPA / ULPA (2) HEPA / ULPA (2) HEPA / ULPA (3) HEPA / ULPA
* The P30 Series is configured with two filter sections, standard. A three filter configuration (similar to the Purair 40) is available to increase
the airflow volume to 590 CFM; specify when ordering.
Electrical Safety TUV (except for units equipped with Monitair controllers)
OSHA, Occupational Safety OSHA Standard -29 CRF, Safety and Health Regulations
and Health Administration for General Industry, 1910.1450: Occupational exposure
to hazardous chemicals in laboratories. Part B, definition,
laboratory type hood. All Air Science products meet this
definition.
Air Science ®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
p:9 Product Options Ductless Fume Hoods 10 • 10XL • 15 • 20 • 25 • 30 • 40
HEPA Safety Filter* An additional carbon, HEPA or ULPA safety <… HEPA and ULPA safety filters for biological safety protection are available for all models. …>
filter exceeding ANSI/AIHA Z9.5 requirements Contact Air Science for ordering information.
ULPA Safety Filter*
can be installed after the main filter.
Filter Saturation An electronic gas sensor emits audio and FSA FSA FSA FSA FSA FSA FSA
Alarm* visual alerts when the main filter needs to be
changed.
SafeSwitch™ Minimizes exposure to filter contaminants ASTM-030-SS ASTM-030-SS ASTM-030-SS ASTM-030-SS ASTM-030-SS ASTM-030-SS ASTM-030-SS
Bag-Out Filter when removing used HEPA filters for insertion
Replacement* of new filters. When replacement is required
a draw cord manually activates an internal
louver set to close the filter face for easy
bag-out recovery.
Stainless Steel Stainless steel spillage tray, slides out for SS-TRAY-P10 SS-TRAY-P10XL SS-TRAY-P15 SS-TRAY-P20 SS-TRAY-P25 SS-TRAY-P30 SS-TRAY-P40
Spill Tray easy cleaning.
Monitair ® Microprocessor controller monitors cabinet MON-P MON-P MON-P MON-P MON-P MON-P MON-P
Controller* operating parameters, airflow, containment,
and filter condition; emits audio and visual
alerts if conditions become unsafe. Not TUV
compliant.
Base Stand, The mobile cart provides a lower storage P10-CART P10XL-CART P15-CART P20-CART P25-CART P30-CART P40-CART
Mobile, With shelf; accommodates wheelchair access.
Casters Locking casters fix the hood in place.
Base Cabinet, Provides storage space below and a cup P10-ENCB P10XL-ENCB P15-ENCB P20-ENCB P25-ENCB P30-ENCB P40-ENCB
Fixed sink, swan neck faucet, and service fixtures.
ADA Compliance* Provides wheelchair access and <… All Purair Advance models are available in ADA compliant configurations. …>
lowered remote controls. Contact Air Science for ordering information.
Polypropylene Cabinets are available in all polypropylene P10-PP P10XL-PP P15-PP P20-PP P25-PP P30-PP P40-PP
Construction* construction. Contact Air Science for P10-XT-PP P10XL-XT-PP P15-XT-PP P20-XT-PP P25-XT-PP P30-XT-PP P40-XT-PP
information. P10-BT-PP P10XL-BT-PP P15-BT-PP P20-BT-PP P25-BT-PP P30-BT-PP P40-BT-PP
Duplex Electrical Two NEMA-1420R receptacles with ground AS-GFI AS-GFI AS-GFI AS-GFI AS-GFI AS-GFI AS-GFI
Outlet * fault interrupter. 110V service standard;
international fixtures available.
Service Fitting Cabinets can be fitted with service fixtures <… SF-X. Specify service fitting type (faucet, valve, petcock) and location when ordering. …>
such as petcocks, faucets or valves.
Tempered Glass Windows are available in tempered glass GLASS-S GLASS-S GLASS-S GLASS-S GLASS-S GLASS-S GLASS-S
Side Windows construction for increased breakage
protection. Contact Air Science for
additional information.
Stainless Steel Hanging rod spans the width of HANGR-P10 HANGR-P10XL HANGR-P15 HANGR-P20 HANGR-P25 HANGR-P30 HANGR-P40
Hanging Rod* the cabinet.
Cup Sink, Mounts Cup sink is fitted into the base tray. SINK-P SINK-P SINK-P SINK-P SINK-P SINK-P SINK-P
into Tray*
Remote Control** The remote control consists of a hand held RC-P RC-P RC-P RC-P RC-P RC-P RC-P
box connected via cable to the head unit,
and can be used inside the work zone.
Includes an On/Off switch and blower
speed control.